首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 22 毫秒
1.
A sensitive, high performance liquid chromatography/tandem mass spectrometric (i.e. mass spectrometry/mass spectrometry; LC/MS/MS) method with on-line extraction and sample clean-up for the screening and confirmation of residues of sulfonamides in kidney is described. The sulfonamides are extracted from homogenized kidney with methanol. After centrifugation of the extract, an aliquot of the extract is directly injected on the LC/MS/MS system with further extraction and clean-up of the sample on-line. Detection of the analytes was achieved by positive electrospray ionization (ESI) followed by multiple reaction monitoring. For each sulfonamide the collisional decomposition of the protonated molecule to a common, abundant fragment ion was monitored. The method has been validated for sulfadimethoxine, sulfaquinoxaline, sulfamethazine, sulfamerazine, sulfathiazole, sulfamethoxazole, sulfadiazine and sulfapyridine. Calibration curves resulting from spiked blank kidney samples at the 10-200 microg/kg level showed good linear correlation. At the level of 50, 100 and 200 microg/kg both within- and between-day precision, as measured by relative standard deviation (RSD), were less than 16%. The limits of detection (LODs) ranged from 5 to 13.5 microg/kg. The recoveries ranged from 78 to 82%. The procedure provides a rapid, reliable and sensitive method for the determination of residues of sulfonamides in bovine kidney. The advantage of this method over existing methods is its decreased sample preparation and analysis time, which makes the method more suitable for routine analysis.  相似文献   

2.
A rapid, specific and highly sensitive multi-residue method for the determination of anabolic steroid residues in bovine, pork and poultry muscle tissues was developed. The sample preparation involves enzymatic digestion followed by extraction with methanol. The crude extract was cleaned up by solid-phase extraction (SPE) combining C18 and NH2 columns. The detection was carried out by a highly sensitive liquid chromatography/electrospray ionization tandem mass spectrometry (LC/ESI-MS/MS) method using both positive and negative ionization modes. Natural and synthetic steroids covering different polarities could be extracted, concentrated and purified using one single method. Mobile phase composition and additives were optimized to achieve the highest sensitivity. The linearity was not good enough for quantitative analysis but the method was well-suited for qualitative confirmation. The method was validated according to the European Commission Decision 2002/657/EC. Decision limits (CCalpha) and detection capabilities (CCbeta) were below 0.5 ng g(-1) for all the compounds in the three types of meat studied. The developed method is suitable for routine analysis in our laboratories.  相似文献   

3.
A novel, sensitive, high performance liquid chromatography/tandem mass spectrometric (i.e. mass spectrometry/mass spectrometry) method with on-line extraction and clean-up for the screening and confirmation of residues of tetracyclines in kidney has been developed. After liquid extraction of homogenised kidney with McIlvain buffer, an aliquot of the extract is directly injected on the LC/MS/MS system with further extraction and clean-up of the sample on-line. Detection of the analytes was achieved by positive electrospray ionization followed by multiple reaction monitoring. For each tetracycline the collisional decomposition of the protonated molecule to a unique, abundant fragment ion was monitored. The method has been validated for tetracycline, oxytetracycline, chlortetracycline and doxycycline. Calibration curves resulting from spiked blank kidney samples at the 100-1200 microgram/kg level showed good linear correlation. At the level of 600 microgram/kg both within- and between-day precision, as measured by relative standard deviation (RSD), were less than 7%. The limits of detection (LODs) for tetracycline, oxytetracycline, chlortetracycline and doxycyline were 18, 23, 24 and 21 microgram/kg, respectively. The limits of quantification (LOQs) for tetracycline, oxytetracycline, chlortetracycline and doxycyline were 36, 46, 47 and 42 microgram/kg, respectively. The recoveries ranged from 71 to 91%. The procedure provides a rapid, reliable and sensitive method for the determination of residues of tetracyclines in bovine kidney. The advantage of this method over existing methods is its decreased sample preparation and analysis time, which makes the method more suitable for routine analysis.  相似文献   

4.
In the work, a rapid, simple and high-throughput sample preparation method was developed for the determination of sulfonamide (SA) antibiotic residues in chicken breast muscle. The extraction and clean-up were online combined and up to 20 samples can be treated simultaneously in 6 min. The SAs were first extracted with acetonitrile under the action of microwave energy, and then the extract was directly introduced into the SPE column for on-line clean-up and concentration. Subsequently, the SAs eluted from the SPE column were determined by liquid chromatography-tandem mass spectrometry. The precisions of extraction results of 20 samples were in the range of 4.9-7.4%. The limits of detection and quantification obtained were in the range of 2.4-3.6 ng/g and 8.6-11.3 ng/g for SAs, respectively. The recoveries of SAs obtained by analyzing chicken muscles at three fortified levels (10, 50 and 500 ng/g) were in the range of 82.6-93.2%. The results of the validation process prove that the proposed method is suitable for treating numbers of complex samples simultaneously in a short time.  相似文献   

5.
Recent studies have shown that selective serotonin reuptake inhibitors (SSRIs) such as fluoxetine are accumulated in the tissues of fish as a result of discharges of pharmaceuticals into surface waters from municipal wastewater treatment plants. In this study, an analytical method based on liquid chromatography with atmospheric pressure chemical ionization and tandem mass spectrometry (LC-APCI-MS/MS) was developed and validated for the determination of residues of paroxetine, fluoxetine and its active metabolite, norfluoxetine, in fish tissue. The procedure for sample preparation includes extraction of tissue by pressurized liquid extraction (PLE), followed by cleanup on a mixed-mode solid phase extraction (SPE) cartridge, Oasis MCX. With the optimized method, matrix interferences were reduced and recoveries >85% were obtained. The limits of quantitation (LOQ) determined by analysis of spiked fish tissue were 0.24, 0.07, and 0.14 ng/g wet weight for paroxetine, fluoxetine and norfluoxetine, respectively. This method was successfully applied to the analysis of samples of fish collected from Hamilton Harbour in Ontario, Canada, which is an urbanized and industrialized embayment of Lake Ontario. These analyses showed that the three analytes were present in fish tissues at concentrations up to approximately 1 microg/kg wet weight.  相似文献   

6.
Ion suppression, a matrix effect that affects quantitative mass spectrometry, is one of the main problems encountered in liquid chromatography/tandem mass spectrometry. Two different clean-up steps for the multi-residue analysis of beta-agonists in urine were evaluated with respect to minimisation of ion suppression, namely, a mixed-phase solid phase extraction (SPE) column, i.e., clean screen Dau (CSD), and a molecular imprinted polymer (MIP) SPE column. Ion suppression experiments revealed that CSD sample clean-up can lead to false negative results for some beta-agonists, and that clean-up using MIP columns is more selective for beta-agonists than the use of CSD columns.  相似文献   

7.
Comparison of methods for the determination of ochratoxin A in wine   总被引:2,自引:0,他引:2  
Different analytical methods for the determination of ochratoxin A (OTA) in wine have been compared. Sample clean-up was based on solid-phase extraction (SPE) with (i) immunoaffinity or (ii) RP-18 sorbent materials applying different experimental protocols. The detection of OTA was accomplished with high-performance liquid chromatography (HPLC) combined either with electrospray ionisation (ESI) tandem mass spectrometry (MS-MS) or fluorescence detection (FL). Comparative method evaluation was based on the investigation of 18 naturally contaminated red wine samples originating from different European countries. The analytical results are discussed in view of the respective method validation data and the corresponding experimental protocols. In general, analytical data obtained with RP-18 SPE combined with LC-MS-MS detection and immunoaffinity extraction combined with FL offered comparable good results in the sub-ppb concentration level indicating that high selectivity of either the sample clean-up or, alternatively the detection system are equally well-suited to guarantee an accurate OTA analysis in wine.  相似文献   

8.
The performance of alkyl-silica sorbent packed solid-phase extraction (SPE) cartridges and a mixed-mode, polymeric sorbent packed SPE cartridge (resin SPE cartridge) were evaluated for the sample preparation of paraquat and diquat in environmental water and vegetation matrices. Also the recoveries of the native and 2H-labeled paraquat and diquat were correlated to validate that the 2H-labeled species can be used for the isotopic dilution mass spectrometry (IDMS) analysis of paraquat and diquat. The results show that the extraction efficiency of alkyl-silica SPE is dependent on the carbon loading of the sorbent and deteriorates with an increasing sample pH. The resin SPE cartridge required no pH adjustment and showed excellent correlation between the native and 2H-labeled species, therefore, allowing us to develop the first liquid chromatography-electrospray ionization IDMS analytical method for the analysis of paraquat and diquat in environmental water and vegetation matrices. Method detection limits derived using standard EPA protocol were 0.2 and 0.1 microg/l for paraquat and diquat in water matrices, and 0.02 and 0.01 microg/g in vegetation matrices, respectively.  相似文献   

9.
Jiangyong Hu  Jing Yu 《Chromatographia》2010,72(5-6):411-416
Recently, there has been increasing concern about perfluorinated surfactants, especially perfluorooctane sulfonate (PFOS) and perfluorooctanoate (PFOA) due to their persistence and chronic toxicity in the aquatic environment. Solid phase extraction (SPE) followed by liquid chromatography coupled with tandem mass spectrometry (LC-MS-MS) are widely applied to quantitatively identify PFOS and PFOA. However, the application of this powerful analytical technique is limited by matrix susceptibility. The co-eluting matrix components in the SPE extracts affect the ionization efficiency and lead to erroneous results. An efficient sample clean-up method was developed in this study to significantly remove co-eluting matrix components by applying the SPE extracts onto a silica cartridge. It was shown that matrix effect (ME%) increased to >70% for both PFOS and PFOA in the analysis of raw sewage. Internal standardization was used to further compensate for the matrix effect, which also proved to improve the signal reproducibility. The clean-up method described in this study was applied to different water samples (surface water and wastewater) to evaluate the efficiency of silica clean-up and the influence of sample origin on the matrix effect. ME% and recovery efficiency (RE%) were in the range of 91.9–98.3% and 89.2–98.0%, respectively. Results showed that the developed method is robust and can be applied to analyze PFOS and PFOA in different environmental matrices.  相似文献   

10.
A simplified protein precipitation/mixed-mode cation-exchange solid-phase extraction (PPT/SPE) procedure has been investigated. A mixture of acetonitrile and methanol along with formic acid was used to precipitate plasma proteins prior to selectively extracting the basic drug. After vortexing and centrifugation, the supernatants were directly loaded onto an unconditioned Oasis MCX microElution 96-well extraction plate, where the protonated drug was retained on the negatively charged sorbent while interfering neutral lipids, steroids or other endogenous materials were washed away. Normal wash steps were deemed unnecessary and not used before sample elution. The sample extracts were analyzed under both conventional and high-speed liquid chromatography/tandem mass spectrometry (LC/MS/MS) conditions to examine the feasibility of the PPT/SPE procedure for human plasma sample clean-up. For the conventional LC/MS/MS method, chromatographic separation was achieved on a C18, 2.1 x 50 mm column with gradient elution (k' = 5.5). The mobile phase contained 0.1% formic acid in water and 0.1% formic acid in acetonitrile. For the high-speed LC/MS/MS method, chromatographic separation was achieved on a C18, 2.1 x 10 mm guard column with gradient elution (k' = 2.2, Rt = 0.26 min). The mobile phase contained 0.1% formic acid in water and 0.001% trifluoroacetic acid in acetonitrile. Detection for both conventional and high-speed LC/MS/MS methods was by positive ion electrospray tandem mass spectrometry on a ThermoElectron Finnigan TSQ Quantum Ultra, where enhanced resolution (RP 2000; 0.2 amu) was used for high-speed LC/MS/MS. The standard curve, ranging from 0.5 to 100 ng/mL, was fitted to a 1/x weighted quadratic regression model.This combined PPT/SPE procedure effectively eliminated time-consuming sorbent conditioning and wash steps, which are essential for a conventional mixed-mode SPE procedure, but retained the advantages of both PPT (removal of plasma proteins) and mixed-mode SPE (analyte selectivity). The validation results demonstrated that this PPT/SPE procedure was well suited for both conventional and high-speed LC/MS/MS analyses. In comparison with a conventional mixed-mode SPE procedure, the simplified PPT/SPE process provided comparable sample extract purity. This simple sample clean-up procedure can be applied to other basic compounds with minor modifications of PPT solvents.  相似文献   

11.
The employment of chemical weapons by rogue states and/or terrorist organizations is an ongoing concern in the United States. The quantitative analysis of nerve agents must be rapid and reliable for use in the private and public sectors. Current methods describe a tedious and time‐consuming derivatization for gas chromatography–mass spectrometry and liquid chromatography in tandem with mass spectrometry. Two solid‐phase extraction (SPE) techniques for the analysis of glyphosate and methylphosphonic acid are described with the utilization of isotopically enriched analytes for quantitation via atmospheric pressure chemical ionization–quadrupole time‐of‐flight mass spectrometry (APCI‐Q‐TOF‐MS) that does not require derivatization. Solid‐phase extraction‐isotope dilution mass spectrometry (SPE‐IDMS) involves pre‐equilibration of a naturally occurring sample with an isotopically enriched standard. The second extraction method, i‐Spike, involves loading an isotopically enriched standard onto the SPE column before the naturally occurring sample. The sample and the spike are then co‐eluted from the column enabling precise and accurate quantitation via IDMS. The SPE methods in conjunction with IDMS eliminate concerns of incomplete elution, matrix and sorbent effects, and MS drift. For accurate quantitation with IDMS, the isotopic contribution of all atoms in the target molecule must be statistically taken into account. This paper describes two newly developed sample preparation techniques for the analysis of nerve agent surrogates in drinking water as well as statistical probability analysis for proper molecular IDMS. The methods described in this paper demonstrate accurate molecular IDMS using APCI‐Q‐TOF‐MS with limits of quantitation as low as 0.400 mg/kg for glyphosate and 0.031 mg/kg for methylphosphonic acid. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

12.
A high-throughput bioanalytical method based on automated sample transfer, automated solid phase extraction, and fast liquid chromatography/tandem mass spectrometry (LC/MS/MS) analysis, has been developed for the determination of the analgesic fentanyl in human plasma. Samples were transferred into 96-well plates using an automated sample handling system. Automated solid phase extraction (SPE) was carried out using a 96-channel programmable liquid-handling workstation using a mixed-mode sorbent. The extracted samples were then dried down, reconstituted and injected onto a silica column using an aqueous/organic mobile phase with tandem mass spectrometric detection. The method has been validated over the concentration range 0.05-100 ng/mL fentanyl in human plasma, based on a 0.25-mL sample size. The assay is sensitive, specific and robust. More than 2000 samples have been analyzed using this method. The automation of the sample preparation steps not only increased the analysis throughput, but also facilitated the transfer of the method between different bioanalytical laboratories of the same organization.  相似文献   

13.
For the detection of anabolic steroid residues in bovine urine, a highly sensitive liquid chromatographic/electrospray ionization tandem mass spectrometric (LC/ESI-MS/MS) method was developed using both positive and negative ionization. For four compounds the ESI mode was not sensitive enough and gas chromatographic/mass spectrometric GC/MS detection was therefore still necessary as a complementary method. The sample clean-up consisted of solid-phase extraction (SPE) on a C(18) column followed by enzymatic hydrolysis and a second solid-phase extraction on a combination of a C(18) and a NH(2) column. After this last SPE clean-up, the eluate was split into two equal aliquots. One aliquot was further purified and after derivatization used for GC/MS analysis. The other aliquot was analyzed with LC/MS/MS in both ESI+ and ESI- modes. The method was validated according to the European Commission Decision 2002/657/EC. Decision limits (CCalpha) were between 0.16 and 1 ng ml(-1) for the compounds detected with the LC/MS/MS method. The developed method is used in routine analysis in our laboratory.  相似文献   

14.
A new, fast and low-cost sample preparation for the determination of sulfonamide (SA) residues in chicken muscle by LC technique has been developed. The procedure involves single extraction of sample with acetonitrile, followed by a rapid clean-up and was called "dispersive solid-phase extraction" (dispersive SPE). Using dispersive SPE 25 mg of octadecyl sorbent was added to 1 ml of acetonitrile extract, mixed and centrifuged. The acetonitrile layer was evaporated and residue was dissolved in acetate buffer (pH 3.5). Analysed compounds were detected by fluorescence detector after pre-column derivatization with fluorescamine. The separation of analytes was performed with gradient elution with mobile phase methanol: 2% acetic acid and RP-LC analytical column. The whole procedure was evaluated for six sulfonamides (sulfadiazine, sulfamerazine, sulfamethazine, sulfametoxypirydazine, sulfametoxazole and sulfadimetoxine) according to the European Commission Decision 2002/657/EC. Specificity, decision limit (CCalpha), detection capacity (CCbeta), trueness and precision were determined during validation process. The dispersive SPE with octadecyl sorbent was found suitable for sample preparation before sulfonamide determination in chicken muscle. As it was found the most of endogenous matrix components were removed and the analytes were isolated from spiked samples with recoveries above 90%. The used analytical conditions allow to successively separate all the tested sulfonamides with the limit of detection at the level of 1-5 microg/kg. The method is simple, rapid and more effective than conventional methods.  相似文献   

15.
A fast, simple and inexpensive sample preparation method based on the matrix solid-phase extraction (SPE) technique is proposed for the isolation of cypermethrin and its metabolite residues from soils. Both the extraction and clean-up procedures were carried out in two steps and target compounds were determined by gas chromatography coupled with electron-impact mass spectrometry (GC-EI/MS). The characteristic ions and fragmentation mechanism of cypermethrin were evaluated by electron impact ionization mass spectrometry (EI/MS). After the optimization of different parameters, such as the extraction solvent, the pesticide was extracted from the matrix with methanol/acetone in a Soxhlet extractor, cleaned up on a Florisil column by elution with a mixture of 30% ethyl acetate in n-hexane and analyzed by gas chromatography-electron impact ionization mass spectrometry (GC-EI/MS) in the selected ion-monitoring mode (SIM) with permethrin as internal standard. Recovery was in the range 77–118% with relative standard deviations (RSD) between 2.5% and 10.2%. The limit of detection (LOD) was 6.5?µg/kg for cypermethrin. The developed method was linear in the injection range 6–30?ng, with correlation coefficients greater than 0.9957.  相似文献   

16.
汤新星  顾源  蔡尚  徐美玲  王畅 《色谱》2012,30(7):696-704
建立了基于高效液相色谱-电喷雾串联质谱(HPLC-ESI MS/MS)与固相萃取(SPE)相结合的大鼠血浆中氨基酸的分析方法。以硅胶基质的强阳离子交换固相萃取柱(SCX-SPE)提取血浆中的氨基酸和降低基质效应,HPLC-ESI MS/MS进行测定。对SPE处理的样品pH值进行了优化,发现pH 2.8时SCX-SPE提取氨基酸的回收率和重现性比较令人满意。除赖氨酸和鸟氨酸外,氨基酸的总体回收率在33.6%~107.7%之间;除精氨酸外,氨基酸标准曲线的线性相关系数r2>0.99; 25种氨基酸测定的日内精密度和日间精密度较好,相对标准偏差(RSD)分别低于9.0%和19.1%。此外,将该分析方法用于电离辐射对大鼠血浆氨基酸代谢的影响研究。结果表明,辐射可导致血浆中氨基酸代谢紊乱,并且其紊乱程度与电离辐射损伤程度正相关。研究结果为筛选新的急性辐射损伤标记物研究提供了实验依据。  相似文献   

17.
Recently, a mixed-mode solid-phase extraction (SPE) procedure was developed for rapid extraction and cleanup for determination of the fungicides thiabendazole and carbendazim in various fruit juices. This paper reports the application of that sample preparation procedure to the liquid chromatographic/mass spectrometric determination of these fungicides in apple juice with detection by positive electrospray ionization mass spectrometry (ESI/MS). Response was linear for sample concentrations from 2 to 500 microg/L (ppb). Recoveries averaged 74% (9% RSD) for carbendazim and 93% (9% RSD) for thiabendazole. After SPE cleanup, no matrix supression was observed for the ESI+ response for either compound studied. The method was applied to the analysis of incurred residues in 4 store-bought apple juices; carbendazim levels ranged from 10 to 70 microg/L and thiabendazole levels ranged from less than 2 to 130 microg/L.  相似文献   

18.
建立了固相萃取-高效液相色谱-串联质谱法测定禽畜和水产品中沃尼妙林、泰妙菌素残留量的分析方法。匀浆样品用乙腈水提取,经盐析和乙腈饱和正己烷除脂后过Oasis MCX SPE小柱净化,采用LC-MS/MS电喷雾电离(ESI)和多反应监测模式(MRM)检测,外标法定量。沃尼妙林和泰妙菌素的检出限均为1.0μg/kg,在1.0~100μg/kg范围内线性关系良好,相关系数r均大于0.99。在1.0~50.0μg/kg的加标水平内的回收率为80.9%~104.3%,RSD为4.7%~7.8%。  相似文献   

19.
An effective analytical method for the screening of mycotoxins, in indoor/outdoor airborne particulate matter, was developed and method performance data are presented. Mycotoxins are natural compounds produced, in particular conditions, as secondary metabolites by filamentous fungi and moulds, and, after their production, they can be transported far from their source. To simulate real samples, an urban dust (reference material 1649a) free from mycotoxins was used as matrix and spiked by the most common mycotoxins, chosen on the basis of studies carried out previously in other real matrices: deoxynivalenol, aflatoxin B1, ochratoxin A, T-2 toxin, zearalenone and sterigmatocystin. The analytical method was optimised and structured in four successive steps: (1) accelerated solvent extraction of the (spiked) analytes from matrix, (2) solid-phase purification (SPE) of the previous extract, (3) pre-concentration of the eluates from SPE and (4) analysis of the concentrated eluates by high performance liquid chromatography tandem mass spectrometry in multiple reaction monitoring mode. After a proper sampling campaign, the method was applied to real indoor and outdoor particulate matter samples, where the clean-up step showed to be very effective and fundamental to avoid misleading analytical results.  相似文献   

20.
A simple and rapid method has been developed and validated for the quantitation of vincristine in human plasma by liquid chromatography/tandem mass spectrometry (LC/MS/MS) with atmospheric pressure chemical ionization using on-line solid-phase extraction. The method uses vinblastine as internal standard and the sample preparation is limited just to a plasma protein precipitation step. Further sample clean-up is carried out on-line through a perfusion column preceding an analytical phenyl LC column, the latter directly connected to the mass spectrometer. Quantitation is performed in multiple reaction monitoring mode using the transitions of m/z 825.3 --> 765.3 and 811.3 --> 751.3 for vincristine and vinblastine respectively. The assay was linear (r2 > or =0.99) in a concentration range from 0.1 to 500 ng/mL. Carry-over, measured on the experimental set-up, was less than 0.04%. Recovery for vincristine and the internal standard was within 90-95%. The intra-day and inter-day assay precision ranged from 1.2% to 6.8% RSD while mean percentage deviation from nominal value ranged from 0.01% to 6.1%. The proposed assay was found suitable for pharmacokinetics investigations and clinical therapeutic drug monitoring especially in pediatric cancer patients.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号