首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 551 毫秒
1.
2.
A neutral, nonpolar monolithic capillary column was evaluated as a hydrophobic stationary phase in pressurized CEC system for neutral, acidic and basic solutes. The monolith was prepared by in situ copolymerization of octadecyl methacrylate and ethylene dimethacrylate in a binary porogenic solvent consisting of cyclohexanol/1,4‐butanediol. EOF in this hydrophobic monolithic column was poor; even the pH value of the mobile phase was high. Because of the absence of fixed charges, the monolithic capillary column was free of electrostatic interactions with charged solutes. Separations of neutral solutes were based on the hydrophobic mechanism with the pressure as the driving force. The acidic and basic solutes were separated under pressurized CEC mode with the pressure and electrophoretic mobility as the driving force. The separation selectivity of charged solutes were based on their differences in electrophoretic mobility and hydrophobic interaction with the stationary phase, and no obvious peak tailing for basic analytes was observed. Effects of the mobile phase compositions on the retention of acidic compounds were also investigated. Under optimized conditions, high plate counts reaching 82 000 plates/m for neutral compounds, 134 000 plates/m for acid compounds and 150 000 plates/m for basic compounds were readily obtained.  相似文献   

3.
A 1,3-alternate 25,27-bis-(pentafluorobenzyloxy)-26,28-bis-(3-propyloxy)-calix[4]arene-bonded silica gel stationary phase (CalixBzF10) was synthesized, structurally characterized, and used as a selector in liquid chromatography. The selectivity study of this phase was done by using fluorine-containing compounds (fluorobenzenes, fluoro-pyrimidine bases), as well as non-fluorinated analytes (non-steroidal anti-inflammatory drugs, sulfonamides, xanthines and polynuclear aromatic hydrocarbons). The effects of organic modifiers on the retention of various compounds possessing basic, acidic and neutral characteristics were studied. It was shown that only basic analytes exhibit a “U-shaped” retention profile and that retention depends on the mobile phase pH. Selectivity comparisons of the novel phase vs. the 1,3-alternate 25,27-bis-(benzyloxy)-26,28-bis-(3-propyloxy)-calix[4]arene phase (CalixBz) were performed. The retention mechanism is also discussed. The results indicate that the fluorinated calixarene stationary phase behaves like reversed-phase packing material; however, fluorine–fluorine interactions seem to be involved in the separation process of fluorine-containing analytes.  相似文献   

4.
Compared to moderately and weakly hydrophilic bases, highly polar basic compounds are even more difficult to separate due to their poor retention in reversed phase (RP) mode. This study described the successful applications of a strong cation exchange (SCX) stationary phase to achieve symmetric peak shape, adequate retention and selectivity in the separation of very polar basic compounds. Salt and acetonitrile concentrations were adjusted to optimize the separation. Good correlations (R2 = 0.998–1.000) between the logarithm of the retention factor and the logarithm of salt or acetonitrile concentration were obtained. Gradients generated by changing salt or acetonitrile concentration were compared for the analysis of different highly polar bases. Although all of the analytes were eluted more quickly with an acetonitrile gradient, the effect of the gradients tested on peak width and peak shape varied with respect to analyte. In addition, the effects of different types of cation and anion additives were also investigated. After separation parameters were acquired, the SCX-based method was utilized to analyze highly hydrophilic alkaloids from Scopolia tangutica Maxim with high separation efficiency (plate numbers > 32,000 m−1). Concurrently, one very polar alkaloid fraction was purified with symmetric peak shape using the current method. Our results suggest that SCX stationary phase can be used as an alternative to RP stationary phase in the analysis and purification of highly hydrophilic basic compounds.  相似文献   

5.
6.
The development of a method for the separation of 2′-2′-difluorodeoxycytidine (gemcitabine, dFdC), 2′-2′-difluorodeoxyuridine (dFdU) and their mono-, di- and triphosphates using a porous graphitic carbon column (Hypercarb), without ion-pairing agent, is described. The retention of dFdC and dFdU could be controlled with an organic modifier (acetonitrile, CH3CN) and the retention of the anionic nucleotides with an eluting ion (bicarbonate). Separation of all analytes was achieved using a 0–25 mM ammonium bicarbonate gradient in CH3CN–H2O (15:85, v/v). Under these conditions, however, very long re-equilibration times were required. Injection of an acidic solution (100 μL 10% formic acid in H2O, v/v; 2.65 M) after running a gradient directly restored the separation capabilities of the column. Still, separation between the analytes slowly deteriorated over a period of months. These problems were solved by preconditioning the column with a pH buffered hydrogen peroxide (H2O2) solution (0.05% H2O2 in CH3CN–H2O (15:85, v/v), pH 4) before starting an analytical run. The oxidation of the stationary phase with H2O2 prevented its slow reduction, which most likely caused the decreasing retention times. The analytes were detected using tandem mass spectrometry.  相似文献   

7.
A multi-residue analytical method based on high-performance liquid chromatographic separation, electrospray ionization with tandem mass spectrometric detection (HPLC/MS–MS) was developed for the simultaneous analysis of 46 basic, neutral and acidic compounds covering a wide range of polarity (log KOW < 0–5.9). The compound list included selected iodinated contrast media, analgesics, anti-inflammatories, stimulants, beta-blockers, antibiotics, lipid regulators, anti-histamines, psychiatric drugs, herbicides, corrosion inhibitors and the gastric acid regulator pantoprazole. The main feature of the presented method was a simultaneous solid phase extraction (SPE) of all analytes followed by simultaneous separation and detection by HPLC/MS–MS with electrospray ionization in both positive and negative polarization within the same chromatogram. Optimization of electrospray drying gas temperature resulted in using a temperature gradient on the ion source. Six different polymeric sorbents for SPE were compared with respect to recoveries, taking into account the specific surface of each sorbent. Method quantitation limits (MQL) in surface and seawater ranged from 1.2 to 28 ng/L, in wastewater from 5.0 to 160 ng/L, respectively. In order to demonstrate the applicability of the method, river water, treated wastewater and seawater were analyzed.  相似文献   

8.
9.
A novel enantioselective polymethacrylate-based monolithic column for capillary electrochromatography was prepared by ring-opening reaction of epoxy groups from poly(glycidyl methacrylate-co-ethylene dimethacrylate) monolith with a novel β-cyclodextrin derivative bearing 4-dimethylamino-1,8-naphthalimide functionalities. Conditions for the ring-opening reaction with respect to different reaction parameters were thoroughly optimized to obtain high electroosmotic flow, separation efficiency and enantioselectivity for the analytes. The nonaqueous mobile phase composition regarding acetonitrile–methanol ratio and the concentration of electrolyte were examined to manipulate the hydrophobic inclusion and anion-exchange interaction between the analytes and chiral stationary phase. It was observed that in addition to β-cyclodextrin cavity, the electrostatic interaction exhibited pronounced influence on the enantioseparation of acidic analytes. Acidic enantiomers (ibuprofen and naproxen) could be separated with separation factor (α) values up to 1.08 and a maximum separation efficiency of 86 000 plates/m could be achieved.  相似文献   

10.
A two-dimensional ion chromatography (2D-IC) approach has been developed which provides greater resolution of complex samples than is possible currently using a single column. Two columns containing different stationary phases are connected via a tee-piece, which enables an additional eluent flow and independent control of eluent concentration on each column. The resultant mixed eluent flow at the tee-piece can be varied to produce a different eluent concentration on the second column. This allows analytes strongly retained on the first column to be separated rapidly on the second column, whilst maintaining a highly efficient, well resolved separation of analytes retained weakly on the first column. A group of 18 inorganic anions has been separated to demonstrate the utility of this approach and the proposed 2D-IC method provided separation of this mixture with resolution of all analytes greater than 1.3. Careful optimisation of the eluent profiles on both columns resulted in run times of less than 28 min, including re-equilibration. Separations were performed using isocratic or gradient elution on the first column, with an isocratic separation being used on the second column. Switching of the analytes onto the second column was performed using a gradient pulse of concentrated eluent to quickly elute strongly retained analytes from the first column onto the second column. The separations were highly repeatable (RSD of 0.01–0.12% for retention times and 0.08–2.9% for peak areas) and efficient (typically 8000–260,000 plates). Detection limits were 3–80 ppb.  相似文献   

11.
通过γ-巯丙基三甲氧基硅烷(KH-590)的作用, 将具有抗菌功能的中草药厚朴的主要药用成分厚朴酚键合在硅胶表面上, 制备了厚朴酚键合硅胶液相色谱固定相. 采用红外光谱、元素分析和热重分析对该固定相进行了表征. 以苯同系物、5种吡啶、6种苯胺和8种芳香羧酸类化合物为溶质探针, 初步考察了该新型固定相的基本色谱性能, 研究了其对这些化合物的保留机理. 结果表明, 该固定相的反相色谱性能类似于十八烷基键合硅胶固定相(ODS), 分离原理与疏水性作用有关; 另外, 该固定相包含有别于疏水性作用的氢键作用、π-π电荷转移作用和偶极-偶极等作用, 多种作用力使其在分离某些可电离的碱性和酸性化合物时表现出更好的选择性和分离效果. 厚朴酚配体的多种作用位点对快速分离极性芳香化合物有重要贡献.  相似文献   

12.
In this study, we present a capillary electrochromatographic method for separation of basic compounds of interest in forensic science (amphetamine, methamphetamine, 3,4-methylenedioxyamphetamine, 3,4-methylenedioxymethamphetamine, 3,4-methylenedioxyethylamphetamine, cocaine, codeine, heroin, morphine, and 6-monoacethylmorphine). Several analytical conditions were taken into account to completely separate in the same run the 10 drugs of abuse analyzed. Chromatographic retention, selectivity and efficiency were evaluated in dependence of the type of stationary phase (CN and RP-C18 derivatized silica particles), mobile phase composition, buffer type and pH, sample injection. The optimum separation parameters were set up using a mixture of aqueous sodium phosphate buffer (pH 2.5)/acetonitrile (80/20, v/v) as the mobile phase, 10 kV and 20 °C as applied voltage and capillary temperature, respectively. Under these conditions all the studied analytes were baseline resolved within 20 min. The method performance was investigated in terms of precision, linearity, sensitivity and accuracy to demonstrate the applicability of the developed capillary electrochromatographic system to forensic analysis. Calibration curves provided a good linearity over a working range of 100–1200 ng/mL for all analytes. Limits of detection and quantification were in the range 5–12 ng/mL and 10–30 ng/mL, respectively. Then the method was applied to the analysis of a human urine sample spiked with a basic compounds’ mixture. Urine samples’ pre-treatment was carried out through a solid phase extraction (SPE) procedure on strong cation exchange (SCX) cartridges.  相似文献   

13.
A polar and neutral polymethacrylate-based monolithic column was evaluated as a hydrophilic interaction capillary electrochromatography (HI-CEC) stationary phase with small polar–neutral or charged solutes. The polar sites on the surface of the monolithic solid phase responsible for hydrophilic interactions were provided from the hydroxy and ester groups on the surface of the monolithic stationary phase. These polar functionalities also attract ions from the mobile phase and impart the monolithic solid phase with a given zeta potential to generate electro-osmotic flow (EOF). The monolith was prepared by in situ copolymerization of a neutral monomer 2-hydroxyethyl methacrylate (HEMA) and a polar cross-linker with hydroxy group, pentaerythritol triacrylate (PETA), in the presence of a binary porogenic solvent consisting cyclohexanol and dodecanol. A typical HI-CEC mechanism was observed on the neutral polar stationary phase for both neutral and charged analytes. The composition of the polymerization mixture was systematically altered and optimized by altering the amount of HEMA in the polymerization solution as well as the composition of the porogenic solvent. The monoliths were tested in the pCEC mode. The resulting monoliths had different characteristics of hydrophilicity, column permeability, and efficiency. The effects of pH, salt concentration, and organic solvent content on the EOF velocity and the separation of nucleic acids and nucleosides on the optimized monolithic column were investigated. The optimized monolithic column resulted in good separation and with greater than 140,000 theoretical plates/m for pCEC.  相似文献   

14.
The study aimed to find the best trade-off between separation of the most critical peak pair and analysis time, in enantioselective GC–FID and GC–MS analysis of lavender essential oil, using the GC method-translation approach. Analysis conditions were first optimized for conventional 25 m × 0.25 mm inner diameter (dc) column coated with 6I–VII-O-tert-butyldimethylsilyl-2I–VII-3I–VII-O-ethyl-β-cyclodextrin (CD) as chiral stationary phase (CSP) diluted at 30% in PS086 (polymethylphenylpolysiloxane, 15% phenyl), starting from routine analysis. The optimal multi-rate temperature program for a pre-set column pressure was determined and then used to find the pressures producing the efficiency-optimized flow (EOF) and speed-optimized flow (SOF). This method was transferred to a shorter narrow-bore (NB) column (11 m × 0.10 mm) using method-translation software, keeping peak elution order and separation. Optimization of the enantioselective GC method with the translation approach markedly reduced the analysis time of the lavender essential oil, from about 87 min with the routine method to 40 min with an optimal multi-rate temperature program and initial flow with a conventional inner diameter column, and to 15 min with FID as detector or 13.5 min with MS with a corresponding narrow-bore column, while keeping enantiomer separation and efficiency.  相似文献   

15.
Two fluoroalcohols--1,1,1,3,3,3-hexafluoro-2-propanol (HFIP) and 1,1,1,3,3,3-hexafluoro-2-methyl-2-propanol (HFTB)--were evaluated as volatile buffer acids in basic mobile phases for LC-ESI-MS determination of acidic and basic compounds. HFIP and HFTB as acidic buffer components offer interesting possibilities to adjust retention behavior of different analytes and expand the currently rather limited range of ESI-compatible buffer systems for basic mobile phases. Comparing with commonly used basic buffer components the fluoroalcohols did not suppress the ionization of the analytes, for several analytes ionization enhancement was observed. RP chromatographic retention mechanisms were evaluated and compared to traditional buffer system. All trends in retention of the acidic and basic analytes can be interpreted by the following model: the neutral fluoroalcohols are quite strongly retained by the stationary phase whereas their anions are less retained, thus their amount on the stationary phase is dependent on mobile phase pH; the anions of the fluoroalcohols form ion pairs in the mobile phase with the basic analytes; the fluoroalcohols on the stationary phase surface compete with acidic analytes thereby hindering their retention; the fluoroalcohols on the stationary phase bind basic analytes thereby favoring their retention.  相似文献   

16.
A new method for the fixation of polymethacrylate monoliths within titanium tubing of up to 0.8 mm I.D. for use as a chromatographic column under elevated temperatures and pressures is described. The preparation of butyl methacrylate–ethylene dimethacrylate-based monolithic stationary phases with desired porous structures was achieved within titanium tubing with pre-oxidised internal walls. The oxidised titanium surface was subsequently silanised with 3-trimethoxysilylpropyl methacrylate resulting in tight bonding of butyl methacrylate porous monolith to the internal walls, providing stationary phase stability at column temperatures up to 110 °C and at operating column pressure drops of >28 MPa. The titanium housed monoliths exhibited a uniform and dense porous structure, which provided peak efficiencies of up to 59,000 theoretical plates per meter when evaluated for the separation of small molecules in reversed-phase mode, under optimal conditions (achieved at 15 μL/min and temperature of 110 °C for naphthalene with a retention factor, k = 0.58). The developed column was applied to the reversed-phase isocratic separation of a text mixture of pesticides.  相似文献   

17.
The nature and extent of mixed-mode retention mechanisms evident for three structurally related, agglomerated, particle-based stationary phases were evaluated. These three agglomerated phases were Thermo Fisher ScientificIon PacAS11-HC – strong anion exchange, Thermo Fisher Scientific IonPac CS10 – strong cation-exchange PS-DVB, and the Thermo Fisher Scientific Acclaim Trinity P1silica-based substrate, which is commercially marketed as a mixed-mode stationary phase. All studied phases can exhibit zwitterionic and hydrophobic properties, which contribute to the retention of charged organic analytes. A systematic approach was devised to investigate the relative ion-exchange capacities and hydrophobicities for each of the three phases, together with the effect of eluent pH upon selectivity, using a specifically selected range of anionic, cationic and neutral aromatic compounds. Investigation of the strong anion-exchange column and the Trinity P1 mixed-mode substrate, in relation to ion-exchange capacity and pH effects, demonstrated similar retention behaviour for both the anionic and ampholytic solutes, as expected from the structurally related phases. Further evaluation revealed that the ion-exchange selectivity of the mixed-mode phase exhibited properties similar to that of the strong anion-exchange column, with secondary cation-exchange selectivity, albeit with medium to high anion-exchange and cation-exchange capacities, allowing selective retention for each of the anionic, cationic and ampholytic solutes. Observed mixed-mode retention upon the examined phases was found to be a sum of anion- and cation-exchange interactions, secondary ion-exchange and hydrophobic interactions, with possible additional hydrogen bonding. Hydrophobic evaluation of the three phases revealed log P values of 0.38–0.48, suggesting low to medium hydrophobicity. These stationary phases were also benchmarked against traditional reversed-phase substrates namely, octadecylsilica YMC-Pac Pro C18 and neutral μPS-DVB resin IonPac NS1-5u, yielding log P values of 0.57 and 0.52, respectively.  相似文献   

18.
A polysaccharide-based chiral stationary phase (Sepapak-4), with cellulose tris(4-chloro-3-methylphenylcarbamate) as chiral selector, has been investigated in liquid chromatography (LC). Its enantioresolution power was evaluated towards 13 basic amino-drugs with widely different structures and polarities, using polar organic mobile phases. After preliminary experiments, acetonitrile was selected as the main mobile phase component, to which a low concentration of diethylamine (0.1%) was systematically added in order to obtain efficient and symmetrical peaks. Different organic solvents were first added in small proportions (5–10%) to acetonitrile to modulate analyte retention. Polar organic modifiers were found to decrease retention and enantioresolution while hexane had the opposite effect, indicating normal-phase behaviour under these conditions. The addition of an organic acid (formic, acetic or trifluoroacetic acid) was found to strongly influence the retention of the basic amino drugs in these nonaqueous systems. The nature and proportion of the acidic additive in the mobile phase had also deep impact on enantioresolution. Therefore, the studied compounds could be subdivided in three groups in respect to the acidic additive used. All analytes could be enantioseparated in relatively short analysis times (10–20 min) using these LC conditions.  相似文献   

19.
Enantioseparation of limonene‐based bicyclic 1,3‐aminoalcohols and 1,3,5‐ and 1,3,6‐aminodiols was performed by normal‐phase high‐performance liquid chromatographic and supercritical fluid chromatographic (SFC) methods on polysaccharide‐based chiral stationary phases. The effects of the composition of the mobile phase, the column temperature and the structures of the analytes and chiral selectors on retention and selectivity were investigated by normal‐phase LC and SFC technique. Thermodynamic parameters derived from selectivity–temperature‐dependence studies were found to be dependent on the chromatographic method applied, the nature of the chiral selector and the structural details of the analytes. Enantiorecognition in most cases was enthalpically driven but an unusual temperature behavior was also observed: decreased retention times were accompanied by improved separation factors with increasing temperature, i.e. some entropically driven separations were also observed. The elution sequence was determined in all cases. The separation of the stereoisomers was optimized in both chromatographic modalities.  相似文献   

20.
Dong X  Wu R  Dong J  Wu M  Zhu Y  Zou H 《Electrophoresis》2008,29(4):919-927
A hydrophilic chiral capillary monolithic column for enantiomer separation in CEC was prepared by coating cellulose tris(3,5-dimethylphenyl-carbamate) (CDMPC) on porous hydrophilic poly(acrylamide-co-N,N'-methylene-bisacrylamide) (poly(AA-co-MBA)) monolithic matrix with confine of a fused-silica capillary. The coating conditions were optimized to obtain a stable and reproducible chiral stationary phase for CEC. The effect of organic modifier of ACN in aqueous mobile phase for the enantiomer separation by CEC was investigated, and the significant influence of ACN on the enantioresolution and electrochromatographic retention was observed. Twelve pairs of enantiomers including acidic, neutral, and basic analytes were tested and nine pairs of them were baseline-enantioresolved with acidic and basic aqueous mobile phases. A good within-column repeatability in retention time (RSD = 2.4%) and resolution (RSD = 3.2%) was obtained by consecutive injections of a neutral compound, benzoin, on a prepared chiral monolithic column, while the between-column repeatability in retention time (RSD = 6.4%) and resolution (RSD = 9.6%) was observed by column-to-column examination. The prepared monolithic stationary phase showed good stability in either acidic or basic mobile phase.  相似文献   