首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 281 毫秒
1.
An electrothermal vaporization (ETV) system useful for the analysis of solutions and slurries has been coupled with a sector-field inductively coupled plasma mass spectrometer (ICP–MS) equipped with an array detector. The ability of this instrument to record the transient signals produced for a number of analytes in ETV–ICP–MS is demonstrated. Detection limits for Mn, Fe, Co, Ni, Cu, Zn and Ga are in the range of 4–60 pg μL 1 for aqueous solutions and in the low μg g 1 range for the analysis of 10 mg mL 1 slurries of Al2O3 powders. The dynamic ranges measured for Fe, Cu and Ga spanned 3–5 orders of magnitude when the detector was operated in the low-gain mode and appear to be limited by the ETV system. Trace amounts of Fe, Cu and Ga could be directly determined in Al2O3 powders at the 2–270 μg g 1 level without the use of thermochemical reagents. The results well agree with literature values for Fe and Cu, whereas deviations of 50% at the 90 μg g 1 level for Ga were found.  相似文献   

2.
A method for the determination of Cu, As, Se, Cd, In, Hg, Tl, Pb and Bi in waters and in biological materials by inductively coupled plasma mass spectrometry, after an on-line separation, is described. The matrix separation and analyte preconcentration is accomplished by retention of the analytes complexed with the ammonium salt of O,O-diethyl dithiophosphoric acid in a HNO3 solution on C18 immobilized on silica in a minicolumn. Methanol, as eluent, is introduced in the conventional pneumatic nebulizer of the instrument. In order to use the best compromise conditions, concerning the ligand and acid concentrations, the analytes were determined in two separate groups. The enrichment factors were in the range from 5 to 61, depending on the analyte. The limits of detection varied from 0.43 ng L−1 for Bi to 33 ng L−1 for Cu. The sample consumption is only 2.3 mL for each group and the sampling frequency is 21 h−1. The accuracy was tested by analysing five certified reference materials: water, riverine water, urine, bovine muscle and bovine liver. The agreement between obtained and certified concentrations was very good, except for As. The relatively small volume of methanol, used as eluent, minimizes the problems produced by the introduction of organic solvent into the plasma.  相似文献   

3.
《Microchemical Journal》2009,91(2):107-112
A simple and powerful microextraction technique was used for determination of cadmium in water samples using liquid phase microextraction (LPME) followed by graphite furnace atomic absorption spectrometry (GF-AAS). In a preconcentration step, cadmium was extracted from a 2 mL of its aqueous sample in the pH = 6 as cadmium-2-(5-bromo-2-pyridylazo)-5-diethylaminophenol (5-Br-PADAP) cationic complex into a 4 µL drop of nitrobenzene and ammonium tetraphenylborate as counter ion. In the drop, the cadmium-2-(5-bromo-2-pyridylazo)-5-diethylaminophenol (5-Br-PADAP) ammonium tetraphenylborate ion associated complex was formed. After extraction, the microdrop was retracted and directly transferred into a graphite tube modified by [Pd(c) + Pd(i)]. Some effective parameters on extraction and complex formation, such as type and volume of organic solvent, pH, concentration of chelating agent and counter ion, extraction time and stirring rate were optimized. Under the optimum conditions, the enrichment factor and recovery were 390 and 78%, respectively. The calibration graph was linear in the range of 0.01–1 µg L 1 with correlation coefficient of 0.9952 under the optimum conditions of the recommended procedure. The detection limit based on the 3Sb criterion was 0.0065 µg L 1 and relative standard deviation (RSD) for eight replicate measurements of 0.1 µg L 1 and 0.4 µg L 1 cadmium was 6.4 and 5.8% respectively. The characteristic concentration was 0.0014 µg L 1 equivalent to a characteristic mass of 5.6 fg. In order to evaluate the accuracy and recovery of the presented method the procedure was applied to the analysis of reference materials and seawater.  相似文献   

4.
The standard enthalpy of formation of several Pd–M alloys (M = In, Sn and Zn) has been measured using a high temperature direct drop calorimeter. The reliability of the calorimetric results has been determined and supported by using different analytical techniques: light optical microscopy, scanning electron microscopy equipped with electron probe microanalysis (EPMA with EDS detector) and X-ray powder diffraction analysis. The values of ΔfH (kJ/mol atoms) for the following phases were obtained for the formation in the solid state at 300 K: PdIn (49 at.%In): ?69.0 ± 1.0; Pd2In3 ?57.0 ± 1.0; Pd3In7: ?43.0 ± 1.0; PdSn2: ?50.0 ± 1.0; Pd2Zn9 (77 at.%Zn): ?33.7 ± 1.0; Pd2Zn9 (78 at.%Zn): ?34.0 ± 1.0; Pd2Zn9 (80 at.%Zn): ?35.0 ± 1.0. The results show exothermic values which increase from the Pd–Zn to the Pd–Sn and Pd–In systems; the data obtained have been discussed in comparison with those available in literature.  相似文献   

5.
A series of heterodinuclear acylpalladium–cobalt complexes having a bidentate nitrogen ligand, L2(RCO)Pd–Co(CO)4 (L2 = bpy, R = Me (5), Ph (6); L2 = tmeda, R = Me (7), Ph (8); L2 = phen, R = Me (9), Ph (10)) are prepared by metathetical reactions of PdRIL2 with Na+[Co(CO)4] followed by treatment with CO. These complexes are characterized by NMR and IR spectroscopies and elemental analyses, and the molecular structures of 6, 8, and 9 are determined by X-ray structure analysis. Geometry at Pd is essentially square planar and the Co atom is considered to have d10 tetrahedral structure, where cobalt(-I) anion coordinates to palladium(II) cation. Heterodinuclear organopalladium–cobalt complexes are shown to catalyze copolymerization of aziridines and CO under mild conditions. Reaction of (dppe)MePd–Co(CO)4 (1) with aziridine gives a cationic (aziridine)palladium(II) complex with [Co(CO)4] anion, [PdMe(aziridine)(dppe)]+[Co(CO)4] (13).  相似文献   

6.
Using a solid phase extraction mini-column home-made from a neutral extractant Cyanex 923, inorganic Hg could be on-line preconcentrated and simultaneously separated from methyl mercury. The preconcentrated Hg (II) was then eluted with 10% HNO3 and subsequently reduced by NaBH4 to form Hg vapor before determination by cold vapor atomic absorption spectrometry (CVAAS). Optimal conditions for and interferences on the Hg preconcentration and measurement were at 1% HCl, for a 25 mL sample uptake volume and a 10 mL min 1 sample loading rate. The detection limit was 0.2 ng L 1 and much lower than that of conventional method (around 15.8 ng L 1). The relative standard deviation (RSD) is 1.8% for measurements of 40 ng L 1 of Hg and the linear working curve is from 20 to 2000 ng L 1 (with a correlation coefficient of 0.9996). The method was applied in determination of inorganic Hg in city lake and deep well water (from Changchun, Jilin, China), and recovery test results for both samples were satisfactory.  相似文献   

7.
Arsenic and germanium have been evaluated as internal standards to minimize matrix effects on the direct determination of selenium in milk by graphite furnace atomic absorption spectrometry (GFAAS) using tubes with integrated platform, pre-treated with W together with Pd as chemical modifier. The efficiency of As and Ge as internal standards for 25 μg L 1 Se plus 500 μg L 1 As or Ge in diluted (1 + 9 v/v) milk plus 1.0% (v/v) HNO3 was evaluated by means of correlation graphs plotted from the normalized absorbance signals (n = 20) of internal standard (axis y) versus analyte (axis x). The equations that describe the linear regression were: AAs =  0.004 ± 0.019 + 1.02 ± 0.019 ASe (r = 0.9967 ± 0.005); AGe =  0.017 ± 0.015 + 1.01 ± 0.015 ASe (r = 0.9978 ± 0.004). Samples and reference solutions were automatically spiked with 500 μg L 1 Ge or As and 1.0% (v/v) HNO3 by the autosampler. For 20 μL of aqueous standard solutions, analytical curves in the 5.00–40.0 μg L 1 Se range were established using the ratio of Se absorbance to internal standard absorbance (ASe / AIS) versus analyte concentration, and good linear correlations were obtained. The characteristic mass was 40 pg Se. Limits of detection were 0.55 and 0.40 μg L 1 with As and Ge as the internal standard, respectively. Relative standard deviations (RSD) for a sample containing 25 μg L 1 Se were 1.2% and 1.0% (n = 12) using As and Ge, respectively. The RSD without internal standardization was about 6%. The accuracy of the proposed method was evaluated by an addition-recovery experiment and all recovered values were in the 99–105% range with IS and in the 70–80% range without IS. Using Ge as the internal standard, results of analysis of standard reference materials were in agreement with certified values at a 95% confidence level. The selenium concentration for 10 analyzed milk samples varied from 5.0 to 20 μg L 1.  相似文献   

8.
A new sorbent based on cysteine modified silica gel (SiG-cys) was prepared and studied for preconcentration and separation of noble metals Au(III), Pd(II), Pt(II), Pt(IV). Its extraction efficiency was examined by batch and column solid phase extraction procedures. Laboratory experiments performed showed that sorbent is characterized with high selectivity, permiting quantitative sorption (93–97%) of noble metals Au, Pd and Pt from acidic media 0.1–2 mol L? 1 HCl and unsignificant sorption (less than 2%) for common base metals like Cu, Fe, Mn and Zn. The analytes retained on the sorbent are effectively eluted with 0.1 mol L? 1 thiourea in 0.1 mol L? 1 HCl and measured by ETAAS or ICP OES under optimal instrumental parameters. The sorbent showed high mechanical and chemical stability and extraction efficiency was not changed after 500 cycles of sorption/desorption. The sorbent was successfully applied in analyticals procedures for preconcentration and determination of Au, Pd and Pt in geological and soil samples. Detection limits (3σ criteria) achieved, depending on the instrumental methods used are: ETAAS (0.005 μg L? 1 for Au in river and sea water, 0.002 μg g? 1 for Au in copper ore and copper concentrate); ICP OES (0.03 μg L? 1 for Pd and 0.06 μg L? 1 for Pt in river and sea water, 0.006 μg g? 1 for Pd in copper ore and copper concentrate and 0.002 μg g? 1 for soluble Pt in soil). The accuracy of the procedures developed was confirmed by added/found method for sea and river water; by the analysis of national certified materials (copper ore and copper concentrate for Au and Pd) and by determination of the sum of soluble Pt(II) + Pt(IV) in spiked soil samples.  相似文献   

9.
This work reports on a novel chitosan–hematite nanotubes composite film on a gold foil by a simple one-step electrodeposition method. The hybrid chitosan–hematite nanotubes (Chi–HeNTs) film exhibits strong electrocatalytic reduction activity for H2O2. Interestingly, two electrocatalytic reduction peaks are observed at −0.24 and −0.56 V (vs SCE), respectively, one controlled by surface wave and the other controlled by diffusion process. The Chi–HeNTs/Au electrode shows a linear response to H2O2 concentration ranging from 1 × 10−6 to 1.6 × 10−5 mol L−1 with a detection limit of 5 × 10−8 mol L−1 and a sensitivity as high as 1859 μA μM−1 cm−2.  相似文献   

10.
A slurry sampling electrothermal atomic absorption spectrometry method for the determination of Al, Ca, Cd, Co, Cr, Cu, Fe, K, Li, Mg, Mn, Na, Ni, Pb, Sr, Tl and Zn in powdered titanium dioxide is described. The behaviour of the titanium matrix in the atomizer and its interferences with the determination of Al, Fe, Co, Ni and Mn were studied. A tungsten carbide modified graphite tube was used to improve the signal shape and the repeatability for the determination of Fe. For all elements, except for Cd and Pb, quantification by a calibration curve established with aqueous standards was possible. No chemical modifier was used throughout in order to minimize contamination. For the contamination risk elements such as Ca, Fe, K, Mg, Na and Zn, the slurry sampling technique allows to achieve limits of detection (3σ of the blank) 5–20 times lower than the solution technique, resulting for these elements in values of 1, 3, 0.5, 0.5, 0.9 and 2 ng g−1, respectively, and, generally being in the range of 0.2 ng g−1 (Cd) to 10 ng g−1 (Al and Tl). The results obtained by the slurry sampling technique are compared with those of other independent methods including four solution methods and neutron activation analysis.  相似文献   

11.
A novel poly(p-xylenolsulfonephthalein) modified glassy carbon electrode was prepared for the simultaneous determination of ascorbic acid (AA), epinephrine (EP) and uric acid (UA). Cyclic voltammetric, chronoamperometric, and differential pulse voltammetric methods were used to investigate the modified electrode for the electrocatalytic oxidation of EP, AA, and UA in aqueous solutions. The separation of the oxidation peak potentials for AA–EP and EP–UA was about 200 and 130 mV, respectively. The calibration curves obtained for AA, EP, and UA were in the ranges of 10–1343, 2–390, and 0.1–560 μmol L−1, respectively. The detection limits (S/N = 3) were 4, 0.1, and 0.08 μmol L−1 for AA, EP and UA, respectively. The diffusion coefficient and the catalytic rate constant for the oxidation of EP at the modified electrode were calculated as 1.40(±0.10) × 10−4 cm2 s−1 and 1.06 × 103 mol−1 L s−1, respectively. The present method was applied to the determination of EP in pharmaceutical and urine samples, AA in commercially available vitamin C tablet, and EP plus UA in urine samples.  相似文献   

12.
This paper reports an electroanalytical method developed for determining the antioxidant tert-butylhydroquinone (TBHQ) in biodiesel, based on the enhancement effect of cetyltrimethylammonium bromide (CTAB). In pH 6.5 Britton–Robinson buffer, a poorly defined oxidation peak was observed for TBHQ at a carbon paste electrode (CPE). In the presence of low concentrations of CTAB, however, the oxidation peak current was markedly increased. Several parameters were studied and optimized for the development of this methodology, and under optimal conditions the oxidation peak current was proportional to TBHQ concentration in the range of (1.05–10.15) × 10−6 mol L−1, with limits of detection and quantification of 7.11 × 10−8 mol L−1 and 2.37 × 10−7 mol L−1, respectively, by linear sweep voltammetry (LSV). The method was applied to TBHQ determination in soybean biodiesel samples. The results were satisfactory in comparison with those obtained using high-performance liquid chromatography (HPLC).  相似文献   

13.
The present paper proposes an on-line pre-concentration system for cadmium determination in drinking water using flame atomic absorption spectrometry (FAAS). Cadmium(II) ions are retained as 1-(2-pyridylazo)-2-naphthol (PAN) complex at the walls of a knotted reactor, followed of elution using hydrochloric acid solution. The optimization was performed in two steps using factorial design for preliminary evaluation and a Box–Behnken design for determination of the critical experimental conditions. The variables involved were: sampling flow-rate, reagent concentration, pH and buffer concentration, and as response the analytical signal (absorbance). The validation process was performed considering the parameters: linearity and other characteristics of the calibration curve, analytical features of on-line pre-concentration system, precision, effect of other ions in the pre-concentration system and accuracy. Using the optimized experimental conditions, the procedure allows cadmium determination with a detection limit (3 σ / S) of 0.10 μg L 1, a quantification limit (10 σ / S) of 0.33 μg L−1, and a precision, calculated as relative standard deviation (RSD) of 2.7% (n = 7) and 2.4% (n = 7) for cadmium concentrations of 5 and 25 μg L 1, respectively. A pre-concentration factor of 18 and a sampling frequency of 48 h−1 were obtained. The recovery for cadmium in the presence of several ions demonstrated that this procedure could be applied for the analysis of water samples. The method was applied for cadmium determination in drinking water samples collected in Salvador City, Brazil. The cadmium concentrations found in five samples were lower than the maximum permissible levels established by the World Health Organization.  相似文献   

14.
In this work, polyvinyl alcohol (PVA) protected silver grass-like nanostructure (PVA–Ag–GNS) with near infrared surface-enhanced Raman scattering (NIR-SERS) activity was prepared and employed to detect DNA and DNA bases. The PVA–Ag–GNS demonstrated high NIR-SERS activity and good optical reproducibility in the detection of adsorbates such as the case of crystal violet, DNA and DNA bases. By using of the tested molecule of thymine, the PVA–Ag–GNS shows a high enhancement factor (EF) of ∼108. For NIR-SERS detection of DNA molecules, Raman signals from the DNA bases of guanine (630 cm−1) and adenine (720 cm−1) are greatly enhanced. For DNA molecules NIR-SERS detection, Raman signals from the DNA bases of guanine (630 cm−1), adenine (720 cm−1) and cytosine (1010 cm−1) are greatly enhanced. The experimental results show that the NIR-SERS spectrum of DNA is dominated by guanine mode, which is followed by adenine and cytosine modes, respectively. Meanwhile, the NIR-SERS signal intensities of the DNA bases increase in the order of thymine (T) < cytosine (C) < adenine (A) < guanine (G). One can conclude that the adsorption strength of the DNA bases in DNA molecule with the silver surface is in the order T < C < A < G, which is different from that of the four DNA bases in individual molecule adsorbed on silver surface (T < A < G < C). On the other hand, the geometry optimization and calculated wavenumber of the complexes of adenine–Ag, guanine–Ag, cytosine–Ag and thymine–Ag for the ground states are performed with DFT, B3LYP functional and the LanL2DZ basis set. The calculated wavenumbers match well with the experimental results. According to our experiment and calculations, DNA base molecules adsorbed on silver surface via the intra-annular nitrogen atom which is adsorbed on the silver nanoparticle and formed metal–molecule complexes by the available lone pair.  相似文献   

15.
The coin-like hollow carbon (CHC) has been synthesized by only using ethanol as the carbon source with a novel Mg/NiCl2 catalytic system via a facile solvothermal method for the first time. The CHC synthesized at optimized conditions shows an average thickness of less than 154 nm and the coin diameter of 1–3 μm. The CHC is characterized by SEM, TEM, XRD and electrochemical techniques. Pd on CHC (denotes as Pd/CHC) electrocatalysts are prepared for methanol oxidation in alkaline media. The Pd/CHC electrocatalyst gives a mass activity of 2930 A g−1 Pd for methanol oxidation against 870 A g−1 Pd on Pd/C electrocatalyst. One main reason for the higher mass activity of the Pd/CHC is the higher electrochemical active surface area (EASA) of the Pd/CHC.  相似文献   

16.
A tungsten–rhodium coating on the integrated platform of a transversely heated graphite atomizer is proposed as a permanent chemical modifier for the determination of Cd, Pb, and Se by electrothermal atomic absorption spectrometry. It was demonstrated that coating with 250 μg W+200 μg Rh is as efficient as the conventional Mg(NO3)2+NH4H2PO4 or Pd+Mg(NO3)2 modifiers for avoiding most serious interferences. The permanent W–Rh modifier remains stable for 300–350 firings of the furnace, and increases tube lifetime by 50%–100% when compared to pyrolytic carbon integrated platforms. Also, there is less degradation of sensitivity during the atomizer lifetime when compared with the conventional modifiers, resulting in a decreased need of re-calibration during routine analysis. The characteristic masses and detection limits achieved using the permanent modifier were respectively: Cd 1.1±0.4 pg and 0.020 μgL−1; Pb 30±3 pg and 0.58 μgL−1 and Se 42±5 pg and 0.64μgL−1. Results from the determination of these elements in water reference materials were in agreement with the certified values, since no statistical differences were found by the paired t-test at the 95% level.  相似文献   

17.
The conventionally mixed LSM–YSZ, LSM impregnated YSZ (LSM + YSZ) and Pd impregnated LSM–YSZ (Pd + LSM–YSZ) cathodes, were prepared and evaluated by electrochemical impedance spectroscopy and single cell testing. The electrochemical performance of the impregnated cathodes have been significantly boosted due to the formation of nano-sized LSM and Pd particles on the YSZ and LSM–YSZ substrates, respectively, and in turn, the increased area of the triple phase boundary (TPB) where the O2 reduction reaction occurs, the power densities as high as 1.42 and 0.83 W cm?2 at 750 °C were achieved from single cells with the Pd + LSM–YSZ and LSM + YSZ cathodes, respectively, in contrast to 0.20 W cm?2 from the single cell with the conventional LSM–YSZ cathode. Suggesting the Pd + LSM–YSZ and LSM + YSZ cathodes can be well used for the intermediate temperature solid oxide fuel cells (IT-SOFCs).  相似文献   

18.
A novel electrochemical platform was designed and prepared for simultaneous determination of p-acetaminophen (AMP) and p-aminophenol (AP) by combining the excellent conductivity and electrocatalytic activities of tetraaminophenyl porphyrin functionalized multi-walled carbon nanotubes (CNTs-CONH-TAPP) and gold nanoparticles (AuNPs). The as-synthesized CNTs-CONH-TAPP composites were characterized by Fourier transform infrared spectroscopy, X-ray photoelectron spectroscopy and scanning electron microscope. The incisive oxidation current responses of AMP and AP at the modified electrode promised a sensitive and selective simultaneous determination of AMP and AP. Under optimized conditions, the peak currents were directly proportional to the concentrations of AMP and AP over the ranges of 4.5–500 μmol L−1 and 0.08–60 μmol L−1, respectively, and the limits of detection were 0.44 μmol L−1 for AMP and 0.025 μmol L−1 for AP(S/N = 3) respectively. The proposed modified electrode showed excellent selectivity, reproducibility and long-term stability and could be applied in simultaneous determination of p-acetaminophen and p-aminophenol in real samples.  相似文献   

19.
A biomonitoring method for the determination of Pb, Cd, and Hg at background levels in whole blood by inductively coupled plasma-mass spectrometry is described. While this method was optimized for assessing Pb, Cd and Hg at environmental levels, it also proved suitable for assessing concentrations associated with occupational exposure. The method requires as little as 200 μl of blood that is diluted 1 + 49 for direct analysis in the inductively coupled plasma-mass spectrometer. Method performance is compared to well-established AAS methods. Initial method validation was accomplished using National Institute of Standards and Technology (NIST) Standard Reference Material 966, Toxic Metals in Bovine Blood. Method detection limits (3s) are 0.05 μg dl 1 for Pb, 0.09 μg l 1 for Cd; and 0.17 μg l 1 for Hg. Repeatability ranged from 1.4% to 2.8% for Pb; 3% to 10% for Cd; and 2.6% to 8.8% for Hg. In contrast, AAS method detection limits were 1 μg dl 1, 0.54 μg l 1, and 0.6 μg l 1, for Pb, Cd, and Hg, respectively. Further performance assessments were conducted over a 2-year period via participation in four international External Quality Assessment Schemes (EQAS) operated specifically for toxic metals in blood. This includes schemes operated by (a) the New York State Department of Health's Wadsworth Center, Albany, NY, USA (b) L′Institut National de Santé Publique du Québec, Centre de Toxicologie du Québec, Canada, (c) Friedrich-Alexander University, Erlangen, Germany, and (d) the University of Surrey, Guildford, UK Trace Elements scheme. The EQAS data reflect analytical performance for blind samples analyzed independently by both inductively coupled plasma-mass spectrometry and AAS methods.  相似文献   

20.
Novel nano-structured Pd+yttrium doped ZrO2 (YSZ) electrodes have been developed as cathodes of intermediate temperature solid oxide fuel cells (IT-SOFCs). Nano-sized Pd particles were introduced into the rigid and porous YSZ structure by PdCl2 solution impregnation. The results show that Pd nanoparticles (20–80 nm) were uniformly distributed in the porous YSZ structure; and such nano-structured composite cathodes were highly active for the O2 reduction reaction, with polarization resistances (RE) of 0.11 and 0.22 Ω cm2 at 750 and 700 °C and activation energy of 105 kJ mol−1 that is significantly lower than those for the conventional perovskite-based cathodes (130–201 kJ mol−1).  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号