首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 203 毫秒
1.
Secondary ion images were obtained from sections of rat brain over a 21 day postnatal period, using the intensity of m/z 184, phosphocholine. When compared with corresponding optical images of similar, but stained sections from the same animal, the secondary ion images appear to reflect less developed brains. During development, myelination occurs after axon extension. Apparently, myelination obscures the source of secondary m/z 184, phosphatidylcholine, from the analyzing ion probe; absenting myelination, secondary ion images show no physiological features.  相似文献   

2.
Secondary ion mass spectra and images were obtained from spikes of choline chloride, acetylcholine chloride, and methylphenylpyridinium iodide deposited onto specimens of porcine brain tissue. Samples were subsequently subjected to a dose of 10-keV Cs+ sufficient to suppress secondary ion emission characteristic of the targeted analytes. Following ablation of the samples by massive glycerol clusters generated by electrohydrodynamic emission, secondary ion mass spectra and images could be obtained that reflected the identity and location of the spiked analytes. The absolute intensity of secondary ion emission that followed ablation was found to be between 30 and 100% of the intensity obtained prior to exposure to the high dose of Cs’. Not all chemical noise is removed by ablation, however, so that the signal-to-noise ratios after ablation correspond to between 10 and 85% of their values observed under conditions of low primary ion dose.  相似文献   

3.
The development of a complete, standard analytical procedure for a quantitative use of secondary ion mass spectrometry to map the distribution in animal tissues of exogenous isotopes presents difficulties inherently related to sample preparation and preservation, as well as to the specific application being considered. We have tested in two very different cases a procedure based on the cryo-preparation of samples and calibration standards. The applications under investigation were the mapping of 10B in mouse brain tissue, with relevance to the boron neutron capture therapy, and of the perfusion tracer 99Tc in mouse heart tissue, with relevance to the study of microcirculation and cardiovascular pathologies. Scanning electron microscopy and inductively coupled mass spectrometry analysis were used as reference techniques for secondary ion mass spectrometry images and analyte measurements, respectively. Cryo-preparation of tissue sections for ion microscopy proved to be simple and efficient (in terms of structural and chemical integrity) for both brain and heart samples derived from fresh organs. This technique, however, turned out to be reliable only on the brain tissue when applied to the preparation of standards, which required chemical fixation of portions of organs. Brain and heart tissues showed a totally different response to chemical fixation, from both a structural and an analytical point of view. On the one hand, we were able to estimate a relative sensitivity factor for 10B in the cryo-sectioned brain matrix; on the other hand, even without the possibility of an absolute quantification of the 99Tc signal and notwithstanding the presence of an isobaric interference, secondary ion mass spectrometry mapping however proved to be capable to resolve the specific response of the cardiac tissue to the perfusion mechanism.  相似文献   

4.
Matrix-assisted laser desorption ionization/ionization imaging mass spectrometry (MALDI IMS) with a time-of-flight analyzer was used to characterize the distribution of lipid molecular species in the brain of rats in two injury models. Ischemia/reperfusion injury of the rat brain after bilateral occlusion of the carotid artery altered appearance of the phospholipids present in the hippocampal region, specifically the CA1 region. These brain regions also had a large increase in the ion abundance at m/z 548.5 and collisional activation supported identification of this ion as arising from ceramide (d18:1/18:0), a lipid known to be associated with cellular apoptosis. Traumatic brain injury model in the rat was examined by MALDI IMS and the area of damage also showed an increase in ceramide (d18:1/18:0) and a remarkable loss of signal for the potassium adduct of the most abundant phosphocholine molecular species 16:0/18:1 (PC) with a corresponding increase in the sodium adduct ion. This change in PC alkali attachment ion was suggested to be a result of edema and influx of extracellular fluid likely through a loss of Na/K-ATPase caused by the injury. These studies reveal the value of MALDI IMS to examine tissues for changes in lipid biochemistry and will provide data needed to eventually understand the biochemical mechanisms relevant to tissue injury.  相似文献   

5.
Tandem mass spectrometry measurements have been achieved using time-of-flight secondary ion mass spectrometry (TOF-SIMS) and a post source decay (PSD)-like method. The performance of the method has been demonstrated on model molecules with well-known fragmentation pathways. Several lipids have been fragmented including the phosphocholine ion, phosphatidylcholines, cholesterol and vitamin E. Pure samples were analyzed, and the results compared with those obtained with the same compounds on a quadrupole-TOF hybrid mass spectrometer. Then, the structures of some lipids which are currently observed in the TOF-SIMS imaging of mammalian tissue sections were verified.  相似文献   

6.
A new liquid metal ion gun (LMIG) filled with bismuth has been fitted to a time-of-flight-secondary ion mass spectrometer (TOF-SIMS). This source provides beams of Bi(n)q+ clusters with n = 1-7 and q = 1 and 2. The appropriate clusters have much better intensities and efficiencies than the Au3+ gold clusters recently used in TOF-SIMS imaging, and allow better lateral and mass resolution. The different beams delivered by this ion source have been tested for biological imaging of rat brain sections. The results show a great improvement of the imaging capabilities in terms of accessible mass range and useful lateral resolution. Secondary ion yields Y, disappearance cross sections sigma, efficiencies E = Y/sigma , and useful lateral resolutions deltaL have been compared using the different bismuth clusters, directly onto the surface of rat brain sections and for several positive and negative secondary ions with m/z ranging from 23 up to more than 750. The efficiency and the imaging capabilities of the different primary ions are compared by taking into account the primary ion current for reasonable acquisition times. The two best primary ions are Bi3+ and Bi5(2+). The Bi3+ ion beam has a current at least five times larger than Au3+ and therefore is an excellent beam for large-area imaging. Bi5(2+) ions exhibit large secondary ions yields and a reasonable intensity making them suitable for small-area images with an excellent sensitivity and a possible useful lateral resolution <400 nm.  相似文献   

7.
To expand the role of high spatial resolution secondary ion mass spectrometry (SIMS) in biological studies, numerous developments have been reported in recent years for enhancing the molecular ion yield of high mass molecules. These include both surface modification, including matrix-enhanced SIMS and metal-assisted SIMS, and polyatomic primary ions. Using rat brain tissue sections and a bismuth primary ion gun able to produce atomic and polyatomic primary ions, we report here how the sensitivity enhancements provided by these developments are additive. Combined surface modification and polyatomic primary ions provided approximately 15.8 times more signal than using atomic primary ions on the raw sample, whereas surface modification and polyatomic primary ions yield approximately 3.8 and approximately 8.4 times more signal. This higher sensitivity is used to generate chemically specific images of higher mass biomolecules using a single molecular ion peak.  相似文献   

8.
Understanding the influence of molecular environment on phospholipids is important in time-of-flight secondary ion mass spectrometry (TOF-SIMS) studies of complex systems such as cellular membranes. Varying the molecular environment of model membrane Langmuir-Blodgett (LB) films is shown to affect the TOF-SIMS signal of the phospholipids in the films. The molecular environment of a LB film of dipalmitoylphosphatidylcholine (DPPC) is changed by varying the film density, varying the sample substrate, and the addition of cholesterol. An increase in film density results in a decrease in the headgroup fragment ion signal at a mass-to-charge ratio of 184 (phosphocholine). Varying the sample substrate increases the secondary ion yield of phosphocholine as does the addition of proton-donating molecules such as cholesterol to the DPPC LB film. Switching from a model system of DPPC and cholesterol to one of dipalmitoylphosphatidylethanolamine (DPPE) and cholesterol demonstrates the ability of cholesterol to also mask the phospholipid headgroup ion signal. TOF-SIMS studies of simplistic phospholipid LB model membrane systems demonstrate the potential use of these systems in TOF-SIMS analysis of cells.  相似文献   

9.
Mass spectrometry imaging is becoming a more and more widely used method for chemical mapping of organic and inorganic compounds from various surfaces, especially tissue sections. Two main different techniques are now available: matrix-assisted laser desorption/ionizaton, where the sample, preliminary coated by an organic matrix, is analyzed by a UV laser beam; and secondary ion mass spectrometry, for which the target is directly submitted to a focused ion beam. Both techniques revealed excellent performances for lipid mapping of tissue surfaces. This article will discuss similarities, differences, and specificities of ion images generated by these two techniques in terms of sample preparation, sensitivity, ultimate spatial resolution, and structural analysis.  相似文献   

10.
Electrospray ionization for analysis of platelet-activating factor.   总被引:1,自引:0,他引:1  
Platelet-activating factor (PAF) was analyzed by electrospray-ionization mass spectrometry (ESI-MS) using a single quadrupole mass spectrometer. The positive-ion spectrum was dominated by an ion corresponding to a sodiated molecule when a low potential difference between the capillary exit (nozzle) and the skimmer was employed, but when the capillary exit voltage was increased, fragmentation of PAF was observed. Initial fragmentation involved the loss of the elements of trimethylamine from the sodiated molecule to yield [M+Na-59]+. An intense ion at m/z 147, generated by the loss of trimethylamine from the sodiated phosphocholine portion of the molecule was also detected, along with a lower intensity ion at m/z 184 which is representative of a protonated phosphocholine moiety. With negative-ion detection the major molecular species was [M+Cl]-. Interpretation of the mass spectral fragments was verified by ESI tandem mass spectrometry on a triple-quadrupole tandem mass spectrometer.  相似文献   

11.
Fourier transform infrared (FTIR) imaging has been used as a molecular histopathology tool on brain tissue sections after intracranial implantation and development of glioma tumors. Healthy brain tissue (contralateral lobe) as well as solid and diffuse tumor tissues were compared for their collagen contents. IR spectra were extracted from IR images for determining the secondary structure of protein contents and compared to pure product spectra of collagens (types I, III, IV, V, and VI). Multivariate statistical analyses of variance and correspondence factorial analysis were performed to differentiate healthy and tumor brain tissues as well as their classification according to their secondary structure profiles. Secondary structure profiles revealed that no collagen was present in healthy tissues; they are also significantly different from solid and diffuse tumors (p < 0.05). Solid and diffuse tumors could be discriminated with respect to the secondary structure profile of fibrillar and non-fibrillar collagens, respectively. We can thus propose to develop FTIR imaging for histopathology examination of tumors on the basis of collagen contents.  相似文献   

12.
Imaging mass spectrometry allows for the direct investigation of tissue samples to identify specific biological compounds and determine their spatial distributions. Desorption electrospray ionization (DESI) mass spectrometry has been used for the imaging and analysis of rat spinal cord cross sections. Glycerophospholipids and sphingolipids, as well as fatty acids, were detected in both the negative and positive ion modes and identified through tandem mass spectrometry (MS/MS) product ion scans using collision-induced dissociation and accurate mass measurements. Differences in the relative abundances of lipids and free fatty acids were present between white and gray matter areas in both the negative and positive ion modes. DESI-MS images of the corresponding ions allow the determination of their spatial distributions within a cross section of the rat spinal cord, by scanning the DESI probe across the entire sample surface. Glycerophospholipids and sphingolipids were mostly detected in the white matter, while the free fatty acids were present in the gray matter. These results show parallels with reported distributions of lipids in studies of rat brain. This suggests that the spatial intensity distribution reflects relative concentration differences of the lipid and fatty acid compounds in the spinal cord tissue. The “butterfly” shape of the gray matter in the spinal cord cross section was resolved in the corresponding ion images, indicating that a lateral resolution of better than 200 μm was achieved. The selected ion images of lipids are directly correlated with anatomic features on the spinal cord corresponding to the white and the gray matter.  相似文献   

13.
Time-of-flight secondary ion mass spectrometry (ToF-SIMS) equipped with a gold ion gun was used to image mouse embryo sections and differentiate tissue types (brain, spinal cord, skull, rib, heart and liver). Embryos were paraffin-embedded and then deparaffinized. The robustness and repeatability of the method was determined by analyzing ten tissue slices from three different embryos over a period of several weeks. Using principal component analysis (PCA) to reduce the spectral data generated by ToF-SIMS, histopathologically identified tissue types of the mouse embryos can be differentiated based on the characteristic differences in their mass spectra. These results demonstrate the ability of ToF-SIMS to determine subtle chemical differences even in fixed histological specimens.  相似文献   

14.
Molecular mass images of tissues will be biased if differences in the physicochemical properties of the microenvironment affect the intensity of the spectra. To address this issue, we have performed—by means of MALDI-TOF mass spectrometry—imaging on slices and lipidomic analysis in extracts of frontal cortex, both from the same postmortem tissue samples of human brain. An external calibration was used to achieve a mass accuracy of 10 ppm (1σ) in the spectra of the extracts, although the final assignment was based on a comparison with previously reported species. The spectra recorded directly from tissue slices (imaging) show excellent s/n ratios, almost comparable to those obtained from the extracts. In addition, they retain the information about the anatomical distribution of the molecular species present in autopsied frozen tissue. Further comparison between the spectra from lipid extracts devoid of proteins and those recorded directly from the tissue unambiguously show that the differences in lipid composition between gray and white matter observed in the mass images are not an artifact due to microenvironmental influences of each anatomical area on the signal intensity, but real variations in the lipid composition.  相似文献   

15.
A secondary ion source has been developed for an organic ion microprobe capable of imaging samples up to 2 em in diameter. The source uses a focused 5 keY Cs+ ion beam which is rastered across the sample surface, and secondary ions from each point on the sample are collected and formed into a low energy beam to be analyzed by a quadrupole mass filter. Dynamic emittance matching is employed to deflect ions from off-axis points on the sample back onto the mass analyzer axis. Rastering and dynamic emittance matching are rapidly controlled by assembly language programs using an IBM/AT (80286) type computer. A low energy ion monitor was used to tune and evaluate the secondary ion source by providing a magnified cross-sectional image of the ion beam at the source exit aperture. A well-focused and centered secondary ion beam was obtained from each point on the sample, indicating that large-scale dynamic emittance matching with high collection efficiency is possible. Mass resolved images of grids and glycerol samples are shown to demonstrate the performance of the integrated secondary ion source mass analyzer and control system.  相似文献   

16.
Time-of-flight secondary ion mass spectrometry (TOF-SIMS) using liquid metal ion guns (LMIGs) is now sensitive enough to produce molecular-ion images directly from biological tissue samples. Primary cluster ions strike a spot on the sample to produce a mass spectrum. An image of this sample is achieved by rastering the irradiated point over the sample surface. The use of secondary ion mass spectrometry for mapping biological tissue surfaces provides unique analytical capabilities; in particular, it enables in a single acquisition a large variety of biological compounds to be localised on a micrometer scale and scrutinised for colocalisations. Without any treatment of the sample, this method is fully compatible with subsequent and complementary analyses like fluorescence microscopy, histochemical staining, or even matrix-assisted laser desorption/ionisation imaging. Basic physical concepts, required instrumentation (ion source and mass analyzer), sample preparation methods, image acquisition, image processing, and emerging biological applications will be described and discussed.  相似文献   

17.
Biological tissue imaging by secondary ion mass spectrometry has seen rapid development with the commercial availability of polyatomic primary ion sources. Endogenous lipids and other small bio-molecules can now be routinely mapped on the sub-micrometer scale. Such experiments are typically performed on time-of-flight mass spectrometers for high sensitivity and high repetition rate imaging. However, such mass analyzers lack the mass resolving power to ensure separation of isobaric ions and the mass accuracy for elemental formula assignment based on exact mass measurement. We have recently reported a secondary ion mass spectrometer with the combination of a C60 primary ion gun with a Fourier transform ion cyclotron resonance mass spectrometer (FT-ICR MS) for high mass resolving power, high mass measurement accuracy, and tandem mass spectrometry capabilities. In this work, high specificity and high sensitivity secondary ion FT-ICR MS was applied to chemical imaging of biological tissue. An entire rat brain tissue was measured with 150 μm spatial resolution (75 μm primary ion spot size) with mass resolving power (mm 50%) of 67,500 (at m/z 750) and root-mean-square measurement accuracy less than two parts-per-million for intact phospholipids, small molecules and fragments. For the first time, ultra-high mass resolving power SIMS has been demonstrated, with mm 50%?>?3,000,000. Higher spatial resolution capabilities of the platform were tested at a spatial resolution of 20 μm. The results represent order of magnitude improvements in mass resolving power and mass measurement accuracy for SIMS imaging and the promise of the platform for ultra-high mass resolving power and high spatial resolution imaging.
Figure
C60 secondary ion FT-ICR MS provides unprecedented mass resolving power and mass accuracy for SIMS imaging of biological tissue sections. Overlaid selected ion images from rat brain (left) and high spatial resolution imaging of organic dye underneath a TEM grid (right).  相似文献   

18.
We contribute to the rapidly emerging interest in the application of time-of-flight secondary ion mass spectrometry (TOF-SIMS) for chemical analysis of biological materials by presenting a careful TOF-SIMS investigation of structurally different SiO2-supported phospholipid assemblies. Freeze-dried supported 1-oleoyl-2-palmitoyl-sn-glycero-3-phosphocholine (POPC) bilayers, Langmuir-Blodgett POPC monolayers, and disordered thick POPC films were investigated. Compared with the two latter structures, the supported bilayer showed a strong (5-10 times) enhancement in the yield of both the molecular and the dimer ion peaks of POPC, suggesting that the molecular peak may be used as a sensitive indicator for changes in the membrane structure and, in particular, an indicator for the presence of bilayer structures in, e.g., cell and tissue samples. The detection efficiency and the useful lateral resolution indicate that a lateral resolution of around 100 nm can be obtained on all structures by imaging the phosphocholine ion at 184 u using Bi3+ primary ions. For the chemically specific molecular peak at 760 u, the measured detection efficiencies correspond to a useful lateral resolution of around 2 microm for the bilayer structure. The results are discussed in relation to recent dynamic SIMS (nano-SIMS) analysis of freeze-dried supported lipid bilayers, displaying similar or higher lateral resolution, but which in contrast to TOF-SIMS requires isotopic labeling of the analyzed lipids.  相似文献   

19.
We have investigated the use of a Gaussian beam laser for MALDI Imaging Mass Spectrometry to provide a precisely defined laser spot of 5 μm diameter on target using a commercial MALDI TOF instrument originally designed to produce a 20 μm diameter laser beam spot at its smallest setting. A Gaussian beam laser was installed in the instrument in combination with an aspheric focusing lens. This ion source produced sharp ion images at 5 μm spatial resolution with signals of high intensity as shown for images from thin tissue sections of mouse brain.
Figure
?  相似文献   

20.
Untargeted analyses in mass spectrometry imaging produce hundreds of ion images representing spatial distributions of biomolecules in biological tissues. Due to the large diversity of ions detected in untargeted analyses, normalization standards are often difficult to implement to account for pixel-to-pixel variability in imaging studies. Many normalization strategies exist to account for this variability, but they largely do not improve image quality. In this study, we present a new approach for improving image quality and visualization of tissue features by application of sequential paired covariance (SPC). This approach was demonstrated using previously published tissue datasets such as rat brain and human prostate with different biomolecules like metabolites and N-linked glycans. Data transformation by SPC improved ion images resulting in increased smoothing of biological features compared with commonly used normalization approaches.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号