首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 390 毫秒
1.
Gyrotron FU CW II with an 8 T liquid He free superconducting magnet, the second gyrotron of the THz Gyrotron FU CW Series, has been constructed and the operation test was successfully carried out. It will be used for enhancing the sensitivity of 600 MHz proton-NMR by use of Dynamic Nuclear Polarization (DNP). The designed operation mode of the gyrotron is TE2,6 at the second harmonic. The corresponding frequency is 394.6 GHz. The real operation frequency is 394.3 GHz at TE06 mode, because of fabrication error of the diameter of the cavity. The operation is in complete CW at the output power of around 30 W or higher at the TE06 cavity mode. There are many other operation modes at the fundamental and the second harmonic. Typical output power of the fundamental and the second harmonic are higher than 100 W and 20 W, respectively. The highest frequency observed up to the present is 443.5 GHz at the second harmonic operation of TE6,5 mode. The measured results are compared with the theoretical consideration.  相似文献   

2.
Long pulse operation up to 1 msec of a high frequency gyrotron with a pulse magnet has been successfully carried out in a frequency range including 1 THz. In the experiments, the timing of an electron beam pulse injection is adjusted at the top of the magnetic field pulse, where the variation of field intensity is negligible. The operation cavity modes seem to be TE1, 12 and TE4,12 at the second harmonics. The corresponding frequencies are 903 GHz and 1,013 GHz, respectively. Additionally several features of radiation measurement results of the gyrotron are described and brief considerations are presented.  相似文献   

3.
The first cw operation of our submillimeter wave gyrotron (Gyrotron FU IV) using a 12 T superconducting magnet has been successfully carried out. Output power is more than 20 W at a frequency of 301 GHz in the TE031 resonant cavity mode. Time-resolved frequency measurement s shows that the frequency fluctuation of the gyrotron output is smaller than 2 MHz. This frequency fluctuation is mainly due to the fluctuation in the output voltage of the power supply.  相似文献   

4.
Design of a CW 1 THz gyrotron at second harmonic operation using a 20 T superconducting magnet has been described. The mode competition analysis is employed to investigate operation conditions of second harmonic mode, which is being excited at the frequency ranging from 920 GHz to 1014 GHz. The output power up to 250 watt corresponding to the efficiency of 4.16 percent could be achieved by using an electron beam with accelerating voltage 30 kV and current 200 mA. The important advantage of this gyrotron is that the single mode excitation at second harmonic, and extremely high frequency of the radiation, could be maintained even at high currents. It opens possibility to realize a high power radiation source at 1 THz. Such gyrotron is under construction at FIR Center, University of Fukui.  相似文献   

5.
The design and operation of a 100 kW, 140 GHz pulsed gyrotron are reported. To our knowledge, this is the highest frequency at which high gyrotron output power (>-100 kW) has been achieved. Results are presented for gyrotron operation in the range of magnetic field from 4 to 7 T, voltage from 23 to 80 kV and current up to 7.5 A. Near a value of magnetic field of 5.4 T, and output power of 100 kW was obtained at 140.4 GHz in single mode operation in the TE031 resonator mode.  相似文献   

6.
The cavity of the newest gyrotron, Gyrotron FU IVA in the high frequency series of Fukui University gyrotrons (the Gyrotron FU series) is designed to minimize the mode conversion from the main cavity mode to the higher modes. In this paper, the experimental results are compared with simulations for the complete gyrotron oscillator. The gyrotron has an additional advantage to cover the wide frequency range in submillimeter wave region.  相似文献   

7.
A CW gyrotron for the sensitivity enhancement of NMR spectroscopy through dynamic nuclear polarization has been designed. The gyrotron operates at the second harmonic and frequency of 394.6 GHz with the main operating mode TE0,6. Operating conditions of other neighboring cavity modes such as TE2,6 at frequency of 392.6 GHz and TE2,3 at frequency of 200.7 GHz were also considered. The experimental conditions of the gyrotron at low and high voltages are simulated. The output power of 56 watts corresponds to the efficiency of 2 percent at low voltage operation and frequency of 394.6 GHz is expected.  相似文献   

8.
High power short pulse gyrotron with operating frequency 395 GHz operating on the second cyclotron harmonic is now under developing at FIR FU. The gyrotron is planned to use in future experiments for plasma diagnostics. For this purpose the output power about 100 kW and pulse duration 100 ns at least are needed. Preliminary estimations of parameters of some versions of the electron guns with accelerating potential U0 = 70-100 kV were performed. Possibilities of non-adiabatic as well as adiabatic guns were considered. It was shown that non-adiabatic system is not reliable for such rather low value of U0, the adiabatic magnetron injection gun (MIG) is more preferable for the gyrotron design. Analytical estimations of the suitable MIG dimensions and operating regime to form good quality electron beam were fulfilled. Numerical optimization of the gun shape and position was performed. It was shown that in spite of the extremely big ratio of the operating current (I0 = 18 A) to the Langmuir current of the gun, close to 0.4-0.5, the suggested MIG can form the helical electron beam (HEB) which is suitable for gyrotron operation properties.  相似文献   

9.
In order to demonstrate the usability of gyrotron oscillators as frequency step tunable high power millimeter-wave sources, experiments on a 1 MW, 140 GHz TE22,6 gyrotron with a built-in quasi-optical (q. o.) mode converter have been performed. By varying the operating parameters of the tube, a series of oscillations in the frequency range from 114 GHz to 166 GHz were excited. To avoid reflections, caused by the required vacuum barrier window, the gyrotron was equipped with a Brewster window. The achieved output power levels between 0.85 and 1.05 MW are compared to measurements carried out with the same tube using a conventional single-disk window. These experiments showed that even by using a q. o. mode converter, the influence of window reflections on the gyrotron oscillatory behavior cannot be removed completely.  相似文献   

10.
11.
HL-2A装置电子回旋共振加热系统的主要指标是2MW/1s/68GHz,系统由4个单元组成,每个单元包括一只回旋管,微波传输系统,控制保护测量和冷却等子系统。通过对ECRH系统和回旋管的调试,每只管子微波输出功率500kW,脉冲宽度1s,四管并联运行时总输出功率达到1.63MW,系统使用效率高于80%。  相似文献   

12.
At certain gyrotron operating conditions, mode cooperation instead of mode competition takes place between a fundamental and a second harmonic mode. This means the phase bunching of a gyrating electron beam under the second harmonic operation reduces the starting current for the fundamental operation and increases total output power as well as beam efficiency. Such mode cooperation is observed in experiments and confirmed by computer simulations for submillimeter wave Gyrotron FU II.  相似文献   

13.
Gyrotron FU II has been successfully applied as a submillimeter wave radiation source to plasma scattering measurements on the Compact Helical System (CHS) in National Institute for Fusion Science (NIFS) in Japan. The gyrotron operates in a long pulse mode (the pulse width is about 600 ms) at a frequency of about 350 GHz (the corresponding wavelength is 0.85 mm). The output power is about 110 W. The output power is transmitted along a circular waveguide system and converted to a Gaussian-like beam by a quasi-optical antenna. After that, the beam is directed onto the CHS plasma and the scattered signal is detected by a homodyne detection system. The frequency and the wave number of the scattered signal are analyzed. The results suggest that a broad band low frequency (several tens to several hundreds kHz) density fluctuation is excited in the CHS plasma only during neutral beam injection (NBI) or ion cyclotron resonance (ICR) heating.  相似文献   

14.
In the 1990’s we initiated development of high frequency gyrotron microwave sources with the goal of performing dynamic nuclear polarization at magnetic fields (∼5–23 T) used in contemporary NMR experiments. This article describes the motivation for these efforts and the developments that led to the operation of a gyrotron source for DNP operating at 250 GHz. We also mention results obtained with this instrument that would have been otherwise impossible absent the increased sensitivity. Finally, we describe recent efforts that have extended DNP to 460 GHz and 700 MHz 1H frequencies.  相似文献   

15.
ESR device using a submillimeter wave gyrotron as a radiation source and a pulse magnet for high field up to 30 T has been constructed. Our gyrotrons (Gyrotron FU series) were developed as millimeter and submillimeter wave radiation sources and have attractive advantages for ESR spectroscopy, for example, high power and frequency tunability over broad range. The ESR device has been successfully applied to three cases of ESR measurements. In the first case, the temperature dependence of ESR was measured for a typical antiferromagnetic material MnO at the frequency of 301 GHz. In the second case, the dependence of the fine structure constant of the ruby on the magnetic field intensity was measured in the millimeter to submillimeter wave region. In these two cases, the gyrotron was operated by complete cw mode. In the final case, a pulse technique was applied to the ESR, the gyrotron was operated in pulse mode and the pulsed magnetic field was generated in the synchronized phase with the gyrotron operation.  相似文献   

16.
A new type of complex cavity structure is used to improve the selectivity of modes in gyrotron resonant cavity with a rational position of inter-cavity wall and the shape of coupling holes between inter- and outer-cavities. The resonant characteristics of the complex cavity operating in TE021/TE031 mode at Ka frequency band are simulated and analyzed with Ansoft HFSS code, which shows that mode competition can effectively be alleviated with the cavity structure and it may be useful to the formation of clustered-cavity for extending interaction frequency bandwidth.  相似文献   

17.
To cover a so-called terahertz gap in available sources of coherent electromagnetic radiation, the gyrotron with a pulsed solenoid producing up to a 40 T magnetic field has been designed, manufactured, and tested. At a 38.5 T magnetic field, the gyrotron generated coherent radiation at 1.022 THz frequency in 50 musec pulses. The microwave power and energy per pulse were about 1.5 kW and 75 mJ, respectively. Details of the gyrotron design, manufacturing, operation and measurements of output radiation are given.  相似文献   

18.
Higher harmonic operation of gyrotrons is necessary to obtain high frequencies. Some gyrotrons included in the Gyrotron FU series developed at Fukui University have achieved operation at the third and even fourth harmonics of the electron cyclotron frequency. The output lies in the millimeter to submillimeter wavelength range and the output powers are several watts to several tens of watts. In this paper, the gyrotrons and the conditions under which they operate are described in detail.  相似文献   

19.
In this paper, the three-dimensional simulation of triode-type magnetron injection gun (MIG) for 120 GHz, 1 MW gyrotron is presented. The operating voltages of the modulating anode and the accelerating anode are 57 kV and 80 kV respectively. The high order TE22,6 mode is selected as the operating mode and the electron beam is launched at the first radial maxima for the fundamental beam-mode operation. The initial design is obtained by using the in-house developed code MIGSYN. The numerical simulation is performed by using the commercially available code CST-Particle Studio (PS). The simulated results of MIG obtained by using CST-PS are validated with other simulation codes EGUN and TRAK, respectively. The results on the design output parameters obtained by using these three codes are found to be in close agreement.  相似文献   

20.
The gyrotron with an electrically insulated collector has been manufactured and tested. The 60% output efficiency is obtained for the Collector Potential Depression (CPD) operation regime. The results of the numerical simulation of the electron energy spectrum in the collector region of the second-harmonic technological 24 GHz gyrotron are presented. It is shown, that the minimal electron beam energy is about 20% of the initial value and that the gyrotron cavity should be expanded to achieve the highest output efficiency of the gyrotron with energy recovery. The highest experimental decelerating voltage is in good agreement with the calculation of the electron energy spectrum.  相似文献   