首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Preliminary results of 2‐D separation of test dye mixture using high‐performance thin‐layer chromatography (HPTLC) and pressurized planar electrochromatography (PPEC) are demonstrated. The advantage of 2‐D HPTLC/PPEC separation is based on different separation selectivities obtained in both HPTLC and PPEC systems. HPTLC RP18 W plates of 5×20 cm from Merck were used in the investigations. In the first dimension, a HPTLC process was performed using 5 cm length of the plate and in the second dimension PPEC separation was obtained applying plate of 20 cm length. PPEC process followed prewetting the chromatographic plate with sample zones on it, which were partly separated after first dimensional (HPTLC) separation. In the experiments, the modified version of PPEC device for 20 cm long chromatographic plate and the reservoir for prewetting the adsorbent layer were applied.  相似文献   

2.
Theoretical backgrounds, development, examples of separations, constructional details and principle of action of devices of pressurized planar electrochromatography (PPEC) are presented. Development of the mode is described in respect of operating variables (composition of the mobile phase, pressure exerted on adsorbent layer, mobile phase flow velocity, temperature of separating system, etc.) influencing separation efficiency (kinetic performance, repeatability, separation time). Advantages of PPEC such as high kinetic performance, short separation time and different separation selectivities, especially relative to conventional thin-layer chromatography, are described. Examples of two-dimensional separations are demonstrated to show high separation potential of the mode when combined with conventional thin-layer chromatography (TLC). The PPEC mode is in infancy stage of development, so its challenges are presented as well.  相似文献   

3.
《Analytical letters》2012,45(2):251-258
Two methods are described for simultaneous determination of amlodipine besylate and olmesartan medoxomil in formulation. The first method was based on the HPTLC separation of two drugs on Merck HPTLC aluminium sheets of silica gel 60 F254 using n-butanol: acetic acid: water (5:1:0.1, v/v/v) as the mobile phase. The second method was based on the HPLC separation of the two drugs on the RP-PerfectSil-100 ODS-3–C18 column from MZ-Analysetechnik GmbH, Germany and acetonitrile/0.03 M ammonium acetate buffer (pH = 3) in a ratio of 55:45 as the mobile phase. Both methods have been applied to formulation without interference of excipients of formulation.  相似文献   

4.
Summary A computer-assisted method is presented for mobile phase selection for the optimal separation of pesticides by HPTLC and HPLC. The system is based on a plot of solute retention value and separation criterion vs. binary mobile phase composition for graphic optimization. The result of HPTLC can be transposed to HPLC for optimal separation. The transposition equation is given.  相似文献   

5.
《Analytical letters》2012,45(9):1641-1653
Abstract

High performance thin layer chromatographic (HPTLC) and high performance liquid chromatographic (HPLC) methods were developed for the simultaneous determination of Tinidazole and Furazolidone in suspension.

In the HPTLC method the separation of Tinidazole and Furazolidone was carried out on silica gel 60F254 HPTLC glass plate using chloroform:methanol:ammonia (9:1:0.1 v/v) as a mobile phase. Rf values obtained were 0.63 and 0.79 for Furazolidone and Tinidazole respectively. Densitometric evaluation was done at 335 nm. Linearity was obtained within the concentration range 10–50 μg/ml and 3.5–17.5 μg/ml for Tinidazole and Furazolidone respectively.

The second method is based on high performance liquid chromatography on a reversed phase column (μ Bondapak C18) using a mobile phase comprised of water: acetonitrile: triethylamine (80:20:0.1 v/v) adjusted to pH = 3.0 with dil. phosphoric acid. Retention times were 5.24 and 7.82 min for Tinidazole and Furazolidone respectively at a flow rate of 1.5 ml/min. Detection was done at 335 nm. Linearity was obtained within the concentration range 30–180 μg/ml and 10.5–63 μg/ml for Tinidazole and Furazolidone resp.  相似文献   

6.
Three modes of sample application on the chromatographic plate are applied at present investigations of pressurized planar electrochromatography (PPEC) systems taking into special attention their influence on performance of the separating system. These modes are as follows: application of the sample solution directly on the chromatographic plate with microsyringe, deposition of sample solution on scrap of adsorbent layer followed by location oft this scrap on the chromatographic plate, application of the sample solution with commercially available aerosol applicator. These modes were combined with prewetting procedures of the chromatographic plates which lead to an accomplishment of equilibration of the stationary phase-mobile phase system. The plots of plate height versus linear flow rate of the mobile phase are presented for PPEC systems for the first time. The best separation performance has been obtained in PPEC system when prewetting of the chromatographic plate followed the sample application with commercially available aerosol applicator. The higher repeatability of migration distance of the solute bands has been obtained in PPEC experiments when the sample application was followed by prewetting the chromatographic plate in comparison to the experiments when these operations were performed in reversed order.  相似文献   

7.
Pressurized planar electrochromatography (PPEC) is a separating technique in which an electric field is applied to force the mobile phase movement through a porous media (electroosmotic effect). High separation efficiency, fast separations and changes in separation selectivity in comparison to liquid chromatography, especially thin layer chromatography (planar chromatography, TLC), are features of this technique. Constructional methodological challenges to PPEC are obstacles to its development and application in laboratory practice. In this article, an attempt to overcome the challenges related to device construction and sample application/injection is described. The introduced device enables both prewetting of the adsorbent layer and electrochromatogram development with a single PPEC device. It also enables simultaneous application/injection of six samples on a chromatographic plate in a stream of the mobile phase (on-line application/injection). In addition, the PPEC chamber was equipped with a thermostat. The device is characterized by an impressive throughput in comparison to the other planar technique, TLC/HPTLC. Although the developed device still needs improvement, it is, in our opinion, a considerable step toward possible automation of this planar separation technique.  相似文献   

8.
《Analytical letters》2012,45(11):1588-1602
Abstract

This article describes validated high-performance liquid chromatographic (HPLC) and high-performance thin-layer chromatographic (HPTLC) methods for simultaneous estimation of alprazolam (ALZ) and sertraline (SER) in pure powder and tablet formulation. The HPLC separation was achieved on a Nucleosil C18 column (150 mm long, 4.6 mm i.d., and 5-µm particle size) using acetonitrile and phosphate buffer (50 + 50 v/v), pH 5.5, as the mobile phase at a flow rate of 1.0 mL/min at ambient temperature. The HPTLC separation was achieved on an aluminum-backed layer of silica gel 60 F254 using acetone/toluene/ammonia (6.0:3.0:1.0, v/v/v) as the mobile phase. Quantification with the HPLC method was achieved with ultraviolet (UV) detection at 230 nm over the concentration range 3–18 µg/mL for both drugs with mean recovery of 101.86 ± 0.21 and 100.57 ± 0.31% for ALZ and SER, respectively. Quantification in HPTLC was achieved with UV detection at 230 nm over the concentration range of 400–1400 ng/spot for both drugs with mean recoveries of 101.32 ± 0.15 and 100.38 ± 0.51% for ALZ and SER, respectively. These methods are rapid, simple, precise, sensitive, and are applicable for the simultaneous determination of ALZ and SER in pure powder and formulations.  相似文献   

9.
Accurate, selective, sensitive and precise HPTLC‐densitometric and RP‐HPLC methods were developed and validated for determination of bumadizone calcium semi‐hydrate in the presence of its alkaline‐induced degradation product and in pharmaceutical formulation. Method A uses HPTLC‐densitometry, depending on separation and quantitation of bumadizone and its alkaline‐induced degradation product on TLC silica gel 60 F254 plates, using hexane–ethyl acetate–glacial acetic acid (8:2:0.2, v/v/v) as a mobile phase followed by densitometric measurement of the bands at 240 nm. Method B comprises RP‐HPLC separation of bumadizone and its alkaline‐induced degradation product using a mobile phase consisting of methanol–water–acetonitrile (20:30:50, v/v/v) on a Phenomenex C18 column at a flow‐rate of 2 mL/min and UV detection at 235 nm. The proposed methods were successfully applied to the analysis of bumadizone either in bulk powder or in pharmaceutical formulation without interference from other dosage form additives, and the results were statistically compared with the established method. Copyright © 2011 John Wiley & Sons, Ltd.  相似文献   

10.
The current paper reports the development and validation of stability‐indicating HPLC and HPTLC methods for the separation and quantification of main impurity and degradation product of Carbimazole. The structures of the degradation products formed under stress degradation conditions, including hydrolytic and oxidative, photolytic and thermal conditions, were characterized and confirmed by MS and IR analyses. Based on the characterization data, the obtained degradation product from hydrolytic conditions was found to be methimazole—impurity A of Carbimazole as reported by the British Pharmacopeia and the European Pharmacopeia. A stability‐indicating HPLC method was carried out using a Zorbax Eclipse Plus CN column (150 × 4.6 mm i.d, 5 μm particle size) and a mobile phase composed of acetonitrile–0.05 m KH2PO4 (20: 80, v/v) in isocratic elution, at a flow rate of 1 mL/min. The method was proved to be sensitive for the determination down to 0.5% of Carbimazole impurity A. Additionally, a stability‐indicating chromatographic HPTLC method was achieved using cyclohexane–ethanol (9:1, v/v) as a developing system on HPTLC plates F254 with UV detection at 225 nm. The proposed HPLC and HPTLC methods were successfully applied to Carbimazole® tablets with mean percentage recoveries of 100.12 and 99.73%, respectively.  相似文献   

11.
《Analytical letters》2012,45(9):1674-1681
Abstract

High-Performance Liquid Chromatography (HPLC) conditions are described for separation of 2,4-dinitrophenylhydrazone (2,4-DNPH) derivatives of carbonyl compounds in a 10 cm long C18 reversed phase monolithic column. Using a linear gradient from 40 to 77% acetonitrile (acetonitrile-water system), the separation was achieved in about 10 min—a time significantly shorter than that obtained with a packed particles column. The method was applied for determination of formaldehyde and acetaldehyde in Brazilian sugar cane spirits. The linear dynamic range was between 30 and 600 µg L?1, and the detection limits were 8 and 4 µg L?1 for formaldehyde and acetaldehyde, respectively.  相似文献   

12.
Relationships between log k' values of polynuclear hydrocarbons and composition of water/methanol mixtures were determined for HPTLC on RP-18 silica and for HPLC using RP-2 silica. In spite of differences in the adsorbents used, a good correlation between HPLC and TLC parameters was found. In the TLC experiments, a sandwich tank with a modified solvent distributor was used. It has been reported that thin-layer chromatography is a good technique for the preliminary optimization of column chromatographic separations [1–5]. So far, the comparison of TLC and HPLC has been mainly restricted to silica as the adsorbent. Since TLC plates precoated with silanized adsorbents recently became commercially available, it seemed interesting to compare the chromatographic parameters obtained for the “reversed phase” systems with the two techniques (see also ref. 6).  相似文献   

13.
Ultra high-performance liquid chromatographic (UHPLC) systems on columns packed with materials ranging from 1.9 to 2.7 μm average particle size were assessed for the fast and sensitive analysis of porphyrins in clinical materials. The fastest separation was achieved on an Agilent Poroshell C(18) column (2.7 μm particle size, 50 × 4.6 mm i.d.), followed by a Thermo Hypersil Gold C(18) column (1.9 μm particle size, 50 × 2.1 mm i.d.) and the Thermo Hypersil BDS C(18) column (2.4 μm particle size, 100 × 2.1 mm i.d.). All columns required a mobile phase containing 1 m ammonium acetate buffer, pH 5.16, with a mixture of acetonitrile and methanol as the organic modifiers for optimum resolution of the type I and III isomers, particularly for uroporphyrin I and III isomers. All UHPLC columns were suitable and superior to conventional HPLC columns packed with 5 μm average particle size materials for clinical sample analysis.  相似文献   

14.
A sensitive and accurate High-Performance TLC (HPTLC) method has been developed to determine the quantity of 6-gingerol in rhizomes of Zingiber officinale (family: Zingiberaceae), commonly known as ginger. Methanol extracts of rhizomes from three different sources were used for HPTLC, n-hexane, and diethyl ether (40:60 v/v) as the mobile phase. The Rf of 6-gingerol was found to be 0.40. The calibration plot was linear in the range of 250-1200 ng of 6-gingerol and the correlation coefficient of 0.9997 was indicative of good linear dependence of peak area on concentration. The mean quantity of 6-gingerol was found to be 60.44+/-2.53 mg/g of ginger extract. The method permits reliable quantification of 6-gingerol and good resolution and separation of 6-gingerol from other constituents of ginger. To study the accuracy and precision of the method, recovery studies were performed by the method of standard addition. Recovery values from 99.79 to 99.84% showed the excellent reliability and reproducibility of the method. The proposed HPTLC method for quantitative monitoring of 6-gingerol in ginger can be used for routine quality testing of ginger extracts.  相似文献   

15.
Marta Kucharska  Jan Grabka 《Talanta》2010,80(3):1045-749
The purpose of this work was to present a chromatographic methods to analyse synthetic food dyes. The following techniques has been described: thin-layer liquid chromatography (TLC), high performance thin-layer chromatography (HPTLC), traditional column chromatography, high performance liquid chromatography (HPLC), include: ion-pair chromatography (HPLC IP), reversed phase chromatography (RP HPLC) and high performance ion chromatography.  相似文献   

16.
Two stability indicating methods have been developed for determining rofecoxib in the presence of its degradation product. The first suggested method is high performance liquid chromatography (HPLC), in which analysis is carried out using hypersil BDS C18 column (250 × 4.6 mm I.D.) with mobile Phase consisting of 0.05 M phosphate buffer (pH 3.5) and acetonitrile (70:30 v/v). A linear relationship was obtained between the detector response at 225 nm and the corresponding concentration of the studied rofecoxib in the concentration range (1–6 μg / 10 μl) with mean % recovery of 99.80 ± 0.405. The second method depends on the quantitative densitometric evaluation of thin layer chromatograms (HPTLC) with mobil phase consisting of toluene: chloroform: methanol (60: 35: 5 v/v/v) by using fluorescent high performance silica gel 60 plate. A linear relationship was obtained between peak area and the concentration of the cited drug in the range 1–6 μg/spot with a mean % recovery of 99.79 ± 0.185. The suggested methods are precise, accurate, rapid and prove their specificity in the presence of its degradation products. Both procedures are successfully applied to determine the drug in the presence of its degradation product and also in their pharmaceutical formulations.  相似文献   

17.
戴朝政  徐小平 《色谱》2020,38(5):581-586
研究了色谱分离过程中物质的径向扩散和流动相发热对柱效能的影响。从热传导方程出发,运用色谱过程动力学原理推导了包括考虑流动相径向扩散、色谱柱发热影响的液相色谱塔板高度方程:

该方程概括了高效液相色谱(HPLC)、超高效液相色谱(UPLC)、毛细管电色谱(CEC)和消滞留层液相色谱(ESFLC)塔板高度与各种因素的关系。方程最后一项代表了径向扩散和柱发热对塔板高度的贡献。当流动相线速度较低且柱内径较细时,流动相摩擦生热和径向扩散对塔板高度的贡献趋近于零,塔板高度方程还原成Horvath和Lin的方程;当流动相线速度较高时,由于流动相摩擦生热,柱轴心与边缘温差增加,导致流动相线速度径向分布差异,使得柱效率降低。柱轴心与边缘的温差与流动相线速度平方成正比。该文指出,在流动相高线速度情况下,液相色谱的柱效率与柱内径密切相关,采用细内径柱有利于实现高速与高效率;过高的流动相线速度将导致色谱柱效率崩溃。  相似文献   

18.
The aim of this work was to find a relationship between electroosmotic flow (EOF) velocity of the mobile phase in pressurized planar electrochromatography (PPEC) and physicochemical properties like zeta potential, dielectric constant, and viscosity of the mobile phase as well as its composition. The study included different types of organic modifiers (acetonitrile, methanol, ethanol, acetone, formamide, N-methylformamide and N,N-dimethylformamide) in the full concentration range. In all experiments, chromatographic glass plates HPTLC RP-18 W from Merck (Darmstadt) were used as a stationary phase. During the study we found that there is no linear correlation between EOF velocity of the mobile phase and single variables such as zeta potential or dielectric constant or viscosity. However, there is quite strong linear correlation between EOF velocity of the mobile phase and variable obtained by multiplying zeta potential of the stationary phase–mobile phase interface, by dielectric constant of the mobile phase solution and dividing by viscosity of the mobile phase. Therefore, it could be concluded that the PPEC system fulfilled the Helmholtz–Smoluchowski equation.  相似文献   

19.
Two selective and accurate chromatographic methods are presented for simultaneous quantitation of spironolactone (SP) and furosemide (FR) and canrenone (CN), the main degradation product and the main active metabolite of SP. Method A was HPTLC, where separation was completed on silica gel HPTLC F254 plates using ethyl acetate–triethylamine–acetic acid (9:0.7:0.5, by volume) as a developing system and UV detection at 254 nm. Method B was a green isocratic RP‐HPLC utilizing a C18 (4.6 × 100 mm) column, the mobile phase consisting of ethanol–deionized water (45: 55, v/v) and UV estimation at 254 nm. Adjustment of flow rate at 1 mL/min and pH at 3.5 with glacial acetic acid was done. Regarding the greenness profile, the proposed RP‐HPLC method is greener than the reported one. ICH guidelines were followed to validate the developed methods. Successful applications of the developed methods were revealed by simultaneous determination of FR, SP and CN in pure forms and plasma samples in the ranges of 0.2–2, 0.05–2.6 and 0.05–2 μg/band for method A and 5–60, 2–60 and 2–60 μg/mL for method B for FR, SP and CN, respectively.  相似文献   

20.
A comparative study is reported on separation of series of mono-, di-, and trisubstituted methyl 5β-cholanates, which differ only in the position and stereochemistry of hydroxyl or keto groups at position and stereochemistry of hydroxyl or keto groups at positions C-3, C-7, and/or C-12, by reversed-phase [with chemically-bonded (C-18) silica gel] and normal-phase (silica gel) high-performance thin-layer chromatography (HPTLC). Methnol (or acetonitrile)/water systems were employed as mobile phase. Reversed-phase HPTLC found to be particulary effective for separation of the stereoisomers of di- and trisubstituted compounds whereas the less polar monosubstituted isomers are well resolved in normal-phase HPTLC.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号