首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
A novel solid-phase microextraction (SPME) fiber coated with multiwalled carbon nanotubes (MWCNTs)/Nafion was developed and applied for the extraction of polar aromatic compounds (PACs) in natural water samples. The characteristics and the application of this fiber were investigated. Electron microscope photographs indicated that the MWCNTs/Nafion coating with average thickness of 12.5 μm was homogeneous and porous. The MWCNTs/Nafion coated fiber exhibited higher extraction efficiency towards polar aromatic compounds compared to an 85 μm commercial PA fiber. SPME experimental conditions, such as fiber coating, extraction time, stirring rate, desorption temperature and desorption time, were optimized in order to improve the extraction efficiency. The calibration curves were linear from 0.01 to 10 μg mL−1 for five PACs studied except p-nitroaniline (from 0.005 to 10 μg mL−1) and m-cresol (from 0.001 to 10 μg mL−1), and detection limits were within the range of 0.03–0.57 ng mL−1. Single fiber and fiber-to-fiber reproducibility were less than 7.5 (n = 7) and 10.0% (n = 5), respectively. The recovery of the PACs spiked in natural water samples at 1 μg mL−1 ranged from 83.3 to 106.0%.  相似文献   

2.
A novel multiwalled carbon nanotubes–polyaniline composite (MWCNTs–PANI) film coated platinum wire was fabricated through electrochemical deposition. The coating was characterized by scanning electron microscopy (SEM), Fourier transform infrared (FTIR) spectrophotometry and thermogravimetry. It was found that the coating was porous and had large specific area and adsorption capacity; in the composite MWCNTs and polyaniline interacted with each other and the film kept stable up to 320 °C. The as-made fiber was used for the headspace solid-phase microextraction (HS-SPME) of some phenolic compounds (i.e. 2-chlorophenol, 2,4-dichlorophenol, 2-methylphenol, 3-methylphenol, 2,6-dimethylphenol, 2-nitrophenol), followed by gas chromatographic analysis. The MWCNTs–PANI coating showed better analytical performance than PANI. Under the optimized conditions, the detection limits were 1.89–65.9 ng L−1, the relative standard deviations (RSDs) were 2.7–6.5% for six successive measurements with single fiber, the RSDs for fiber-to-fiber were 5.2–12.4%, the linear ranges exceeded two magnitudes with correlation coefficient above 0.992. The fiber could be used for more than 250 times without decrease of efficiency. The proposed method was successfully applied to the extraction and determination of phenolic compounds in water sample, and the recoveries were 87.7–111.5% for different analytes. In addition, the fiber also presented advantages of easy preparation and low cost. Therefore, it is a promising SPME fiber.  相似文献   

3.
In this paper, bamboo charcoals were modified using Fe3O4 nanosheets for the first time. The composites, as a novel solid-phase microextraction (SPME) fiber coating, were used for the extraction of seven polybrominated diphenyl ethers (PBDEs) in environmental water samples. The extraction factors (stirring rate, extraction time, and ionic strength) and desorption factors (desorption time and desorption temperature) of the fibers were systematically investigated and optimized. Under optimum conditions, the linear range was 1–1000 ng L−1. Based on the ratio of chromatographic signal to base line noise (S N−1 = 3), the limits of detection (LODs) can reach 0.25–0.62 ng L−1. The novel method was successful in the analysis of PBDEs in real environmental water samples. The results indicate that bamboo charcoal/Fe3O4 as an SPME coating material coupled with gas chromatography–negative chemical ionization-mass spectrometry is an excellent method for the routine analysis of PBDEs at trace levels in environmental water samples.  相似文献   

4.
A novel solid phase microextraction (SPME) fiber was fabricated by electrospinning method in which a polymeric solution was converted to nanofibers using high voltages. A thin stainless steel wire was coated by the network of polymeric nanofibers. The polymeric nanofiber coating on the wire was mechanically stable due to the fine and continuous nanofibers formation around the wire with a three dimensional structure. Polyamide (nylon 6), due to its suitable characteristics was used to prepare the unbreakable SPME nanofiber. The scanning electron microscopy (SEM) images of this new coating showed a diameter range of 100–200 nm for polyamide nanofibers with a homogeneous and porous surface structure. The extraction efficiency of new coating was investigated for headspace solid-phase microextraction (HS-SPME) of some environmentally important chlorophenols from aqueous samples followed by gas chromatography–mass spectrometry (GC–MS) analysis. Effect of different parameters influencing the extraction efficiency including extraction temperature, extraction time, ionic strength and polyamide amount were investigated and optimized. In order to improve the chromatographic behavior of phenolic compounds, all the analytes were derivatized prior to the extraction process using basic acetic anhydride. The detection limits of the method under optimized conditions were in the range of 2–10 ng L−1. The relative standard deviations (RSD) (n = 3) at the concentration level of 1.7–6.7 ng mL−1 were obtained between 1 and 7.4%. The calibration curves of chlorophenols showed linearity in the range of 27–1330 ng L−1 for phenol and monochlorophenols and 7–1000 ng L−1 for dichloro and trichlorophenols. Also, the proposed method was successfully applied to the extraction of phenol and chlorophenols from real water samples and relative recoveries were between 84 and 98% for all the selected analytes except for 2,4,6 tricholophenol which was between 72 and 74%.  相似文献   

5.
Two kinds of mesoporous cellular foams (MCFs), including mesoporous silica materials (MCF-1) and phenyl modified mesoporous materials (Ph-MCF-1), were synthesized and for the first time used as fiber-coating materials for solid-phase microextraction (SPME). By using stainless steel wire as the supporting core, four types of fibers were prepared by sol–gel method and immobilized by epoxy-resin method. To evaluate the performance of the home-made fibers for SPME, seven brominated flame retardants (BFRs), including tetrabromobisphenol A (TBBPA), tetrabromobisphenol S (TBBPS) and related compounds were selected as analytes. The main parameters that affect the extraction and desorption efficiencies, such as extraction temperature, extraction time, desorption time, stirring rate and ionic strength of samples were investigated and optimized. The optimized SPME coupled with high performance liquid chromatography (HPLC) was successfully applied to the determination of the seven BFRs in water samples. The linearity range was from 5.0 to 1000 μg L−1 for each compound except TBBPS (from 1.0 to 1000 μg L−1), with the correlation coefficients (r2) ranging from 0.9993 to 0.9999. The limits of detection of the method were 0.4–0.9 μg L−1. The relative standard deviations varied from 1.2 to 5.1% (n = 5). The repeatability of fiber-to-fiber and batch-to-batch was 2.5–6.5% and 3.2–6.7%. The recoveries of the BFRs from aqueous samples were in the range between 86.5 and 103.6%. Compared with three commercial fibers (100 μm PDMS, 85 μm PA and 65 μm PDMS/DVB), the MCFs-coated fiber showed about 3.5-fold higher extraction efficiency.  相似文献   

6.
Metal-organic frameworks (MOFs) have received great attention as novel sorbents due to their fascinating structures and intriguing potential applications in various fields. In this work, a MIL-101(Cr)-coated solid-phase microextraction (SPME) fiber was fabricated by a simple direct coating method and applied to the determination of volatile compounds (BTEX, benzene, toluene, ethylbenzene, m-xylene and o-xylene) and semi-volatile compounds (PAHs, polycyclic aromatic hydrocarbons) from water samples. The extraction and desorption conditions of headspace SPME (HS-SPME) were optimized. Under the optimized conditions, the established methods exhibited excellent extraction performance. Good precision (<7.7%) and low detection limits (0.32–1.7 ng L−1 and 0.12–2.1 ng L−1 for BTEX and PAHs, respectively) were achieved. In addition, the MIL-101(Cr)-coated fiber possessed good thermal stability, and the fiber can be reused over 150 times. The fiber was successfully applied to the analysis of BTEX and PAHs in river water by coupling with gas chromatography–mass spectrometry (GC–MS). The analytes at low concentrations (1.7 and 10 ng L−1) were detected, and the recoveries obtained with the spiked river water samples were in the range of 80.0–113% and 84.8–106% for BTEX and PAHs, respectively, which demonstrated the applicability of the self-made fiber.  相似文献   

7.
A novel proton-type ionic liquid doped polyaniline (HIL-doped PANI) coating was presented, which was prepared on a stainless steel wire by electrodeposition in an aqueous solution containing aniline and 1-sulfobutyl-3-methylimidazolium hydrosulfate. The HIL-doped PANI coating showed granular nanostructure and had large specific surface. When it was applied to the headspace solid-phase microextraction of several amines (i.e., aniline, N-methylaniline, 3-methylaniline, 2-chloroaniline and 3-chloroaniline), it showed high extraction efficiency. The enrichment factors were 191.8–343.9 for different amines, much higher than those of common PANI and commercial polydimethylsiloxane/divinylbenzene coatings. Coupled with gas chromatographic analysis, the linear ranges were 0.097–100 μg/L with correlation coefficients above 0.9942, and the detection limits were 0.012–0.048 μg/L (S/N = 3) for different amines. The relative standard deviations (RSD) were smaller than 8.1% for five successive measurements with single fiber and the fiber-to-fiber RSDs were 8.6–13.8% (n = 5) for these amines. The proposed method was successfully applied to the extraction and determination of amines in organic waste water samples, and the recoveries were 78.3–112.8% for different analytes.  相似文献   

8.
A new fiber for solid-phase microextraction (SPME) was prepared employing cork as a coating. The morphology and composition of the cork fiber was evaluated by scanning electron microscopy (SEM) and Fourier transform infrared spectroscopy (FTIR), respectively. The proposed fiber was used for the determination of polycyclic aromatic hydrocarbons (PAHs) in river water samples by gas chromatography–selected ion monitoring–mass spectrometry (GC–SIM–MS). A central composite design was used for optimization of the variables involved in the extraction of PAHs from water samples. The optimal extraction conditions were extraction time and temperature of 60 min and 80 °C, respectively. The detection and quantification limits were 0.03 and 0.1 μg L−1, respectively. The recovery values were between 70.2 and 103.2% and the RSD was ≤15.7 (n = 3). The linear range was 0.1–10 μg L−1 with r ≥ 0.96 and the fiber-to-fiber reproducibility showed RSD ≤ 18.6% (n = 5). The efficiency of the cork fiber was compared with commercially available fibers and good results were achieved, demonstrating the applicability and great potential of cork as a coating for SPME.  相似文献   

9.
An aniline-based polymer was electrochemically prepared and applied as a new fiber coating for solid phase microextraction (SPME) of some priority phenols from water samples. The polyaniline (PANI) film was directly electrodeposited on the platinum wire surface in sulfuric acid solution using cyclic voltammetry (CV) technique. The efficiency of new coating was investigated using a laboratory-made SPME device and gas chromatography with flame ionization detection for the extraction of some phenols from the headspace of aqueous samples. The scanning electron microscopy (SEM) images showed the homogeneity and the porous surface structure of the film. The results obtained proved the ability of this polymer as a suitable SPME fiber coating for trapping the selected phenols. Influential parameters affecting the extraction process were optimized and an extraction time of 50 min at 50 °C gave maximum efficiency, when the aqueous sample was saturated with NaCl and adjusted at pH 2. This new coating can be prepared easily in a reproducible manner and it is rather inexpensive and stable against most of organic solvents. The PANI thickness can be precisely controlled by the number of CV cycles. At the optimum conditions, the R.S.D. for a double distilled water spiked with phenol and chlorophenols at ppb level were 4.8-17% (n = 3) and detection limits for the studied compounds were between 0.69 and 3.7 ng ml−1, except for phenol and 4-chlorophenol. The optimized method was successfully applied to some real-life water samples.  相似文献   

10.
In this paper, we proposed an approach using a multi-walled carbon nanotubes (MWCNTs)/Nafion composite coating as a working electrode for the electrochemically enhanced solid-phase microextraction (EE-SPME) of charged compounds. Suitable negative and positive potentials were applied to enhance the extraction of cationic (protonated amines) and anionic compounds (deprotonated carboxylic acids) in aqueous solutions, respectively. Compared to the direct SPME mode (DI-SPME) (without applying potential), the EE-SPME presented more effective and selective extraction of charged analytes primarily via electrophoresis and complementary charge interaction. The experimental parameters relating to extraction efficiency of the EE-SPME such as applied potentials, extraction time, ionic strength, sample pH were studied and optimized. The linear dynamic range of developed EE-SPME-GC for the selected amines spanned three orders of magnitude (0.005–1 μg mL−1) with R2 larger than 0.9933, and the limits of detection were in the range of 0.048–0.070 ng mL−1. All of these characteristics demonstrate that the proposed MWCNTs/Nafion EE-SPME is an efficient, flexible and versatile sampling and extraction tool which is ideally suited for use with chromatographic methods.  相似文献   

11.
A simple, efficient, innovative and environmentally friendly analytical technique was successfully applied for the first time for the extraction and preconcentration of polybrominated diphenyl ethers (PBDEs) from water samples. The PBDEs selected for this work were those most commonly found in the literature in natural water samples: 2,2′,4,4′-tetraBDE (BDE-47), 2,2′,4,4,5-pentaBDE (BDE-99), 2,2′,4,4,6-pentaBDE (BDE-100) and 2,2,4,4′,5,5′-hexaBDE (BDE-153). The extracted PBDEs were separated and determined by gas chromatography–mass spectrometry (GC–MS). The extraction/preconcentration technique is based on ultrasound-assisted emulsification-microextraction (USAEME) of a water-immiscible solvent in an aqueous medium. Several variables including, solvent type, extraction time, extraction temperature and matrix modifiers were studied and optimized over the relative response the target analytes. Chloroform was used as extraction solvent in the USAEME technique. Under optimum conditions, the target analytes were quantitatively extracted achieving enrichment factors (EF) higher than 319. The detection limits (LODs) of the analytes for the preconcentration of 10 mL sample volume were within the range 1–2 pg mL−1. The relative standard deviations (RSD) for five replicates at 10 pg mL−1 concentration level were <10.3%. The calibration graphs were linear within the concentration range of 5–5000 pg mL−1 for BDE-47 and BDE-100; and 5–10,000 pg mL−1 for BDE-99 and BDE-153, respectively. The coefficients of estimation were ≥0.9985. Validation of the methodology was performed by standard addition method at two concentration levels (10 and 50 pg mL−1). Recovery values were ≥96%, which showed a successful robustness of the analytical methodology for determination of picogram per milliliter of PBDEs in water samples. Significant quantities of PBDEs were not found in the analyzed samples.  相似文献   

12.
Carbon nanotubes are a kind of new carbon-based nanomaterials, which have drawn great attention in many application fields. The potential of single-walled carbon nanotubes (SWCNTs) as solid-phase microextraction (SPME) adsorbent for the preconcentration of environmental pollutants has been investigated in recent years. In the present study, the feasibility of SWCNTs as SPME adsorbent for the determination of monobutyltin, dibutyltin and tributyltin in seawater samples was studied. To achieve this aim, the potential factors affecting the SPME efficiency, including extraction time, extraction temperature, desorption time, desorption temperature, and salinity were optimized. The developed method showed good performance according to the ICH (International Conference on Harmonization of Technical Requirements for Analytical Methods) criteria. The acquired calibration curves were linear (r ≥ 0.992) over the concentration range from ≤12 to 2000 ng L−1. For all of the analytes, the limit of detection at signal-to-noise ratio of 3 was below 5 ng L−1. Furthermore, in comparison with the commercial carboxen/polydimethylsiloxane fiber, the developed SWCNT fiber showed better thermal stability (over 350 °C) and longer life span (over 150 times). The application of the proposed method in environmental analyses was shown by analyzing seawater samples from the harbors on the Persian Gulf for butyltin residues. Some of the butyltins were detected in the analyzed samples. Results of the present study demonstrate the feasibility of the SWCNTs as SPME adsorbent for the determination of butyltins in seawater samples.  相似文献   

13.
This work is a first study on extraction efficiency and thermal stability of nano-structured self-doped polyaniline (SPAN) as a coating of solid-phase microextraction (SPME) fibers. SPAN-based fibers were prepared using electrochemical deposition on platinum wires. The particle sizes of prepared nano-structure were in the range of 50–100 nm. Extraction properties of the fiber to 1,4-dioxane were examined using headspace solid-phase microextraction (HS-SPME) coupled to gas chromatography-flame ionization detection (GC-FID). The results have proved higher thermal stability of the proposed fiber compared to common PANI fiber. The SPAN coating was proved to be very stable at relatively high temperatures (up to 350 °C) with high extraction capacity and long lifespan (more than 50 times). Therefore, it can be a good substitute of polyaniline (PANI) as a SPME coating. The extraction procedure was optimized by selecting the appropriate extraction parameters including extraction time, extraction temperature, salt concentration, stirring rate and headspace volume. Calibration graph was linear in the concentration range of 1–100 ng mL−1 (R2 > 0.993) with detection limit of 0.1 ng mL−1. Single fiber and fiber-to-fiber repeatability were lower than 6.0% and 10.4%, respectively. Different water samples were analyzed as real samples and good recoveries (98–120%) were obtained.  相似文献   

14.
Mesoporous TiO2 nanoparticles were synthesized with the hydrothermal method and characterized by powder X-ray diffraction (PXRD) and transmission electron microscope (TEM). Then a superior solid-phase microextraction (SPME) fiber was fabricated by sequentially coating the stainless steel fiber with silicone sealant film and mesoporous TiO2 powder. The developed fiber possessed a homogeneous surface and a long life-span up to 100 times at direct immersing (DI) extraction mode. Under the optimized conditions, the extraction efficiencies of the self-made 17 μm TiO2 fiber for six organochlorine pesticides (OCPs) were higher than those of the two commercial fibers (65 μm PDMS/DVB and 85 μm PA fibers) which were much thicker than the former. As for analytical performance, low detection limits (0.08–0.60 ng L−1) and wide linearity (5–5000 ng L−1) were achieved under the optimal conditions. The repeatabilities (n = 5) for single fiber were between 2.8 and 12.3%, while the reproducibilities (n = 3) of fiber-to-fiber were in the range of 3.7–15.7%. The proposed fiber was successfully applied to the sensitive analysis of OCPs in real water samples and four of the six analytes were detected from the rainwater and the lake water samples.  相似文献   

15.
Solid-phase microextraction method (SPME) coupled to GC/ECD has been developed and validated for the determination of phthalic acid esters (dimethyl-, diethyl-, di-n-butyl-, butylbenzyl-, di-2-ethylhexyl- and di-n-octyl phthalate) in water samples. Two types of coatings (PDMS, PA), altogether four different kinds of fibers have been investigated. Both parameters affecting the partition of analytes between a fiber coating and aqueous phase (i.e. extraction time, extraction temperature, agitation) and conditions of the thermal desorption in a GC injector were optimized. The final SPME method employing the polyacrylate fiber, extraction time 20 min, heating and stirring of the sample enabled the determination of all six phthalates in water samples. The method showed linear response over four orders of magnitude and the limits of quantification of the method ranged between 0.001 and 0.050 μg l−1. The repeatability expressed as R.S.D. was in the range 4-10% for the spiking level 7 μg l−1 of each analyte. The applicability of the developed SPME method was demonstrated for real water samples.  相似文献   

16.
A novel and efficient analytical methodology is proposed for extracting and preconcentrating polybrominated diphenyl ethers (PBDEs) from samples of environmental interest prior gas chromatography–mass spectrometry (GC–MS) analysis. It is based on the induction of micellar organized medium by using a non-ionic surfactant (Triton X-114) to extract the target PBDEs. To enable coupling the efficient extracting technique with GC analysis, ultrasound-assisted back-extraction (UABE) into an organic solvent was required. Several factors, including surfactant type and concentration, equilibration temperature and time, ionic strength, pH and buffers nature and concentration were studied and optimized over the extraction efficiency of the proposed technique. Under optimal experimental conditions, the target analytes were quantitatively extracted achieving an enrichment factor of 250 when 10 mL aliquot of ultrapure water spiked with PBDE-standard mixture (10 pg mL−1 each PBDE) was extracted. Method detection limits (MDLs) calculated with aqueous PBDEs solutions as three times the signal-to-noise ratio (S/N), ranged from 1 to 2 pg mL−1 with RSDs values ≤8.5% (n = 5). The coefficients of estimation of the calibration curves obtained following the proposed methodology were ≥0.9987 and linear range of all PBDEs was 4–150 pg mL−1. The proposed methodology was validated by carrying out a recovery study by spiking the samples at two different concentration levels of PBDEs (10 and 50 pg mL−1 for waters samples). Recoveries values in the range of 96–106% for water samples were obtained showing satisfactory robustness of the method for analyzing PBDEs in water samples. The proposed methodology was applied for the analysis of PBDEs: 2,2′,4,4′-tetraBDE (BDE-47), 2,2′,4,4,5-pentaBDE (BDE-99), 2,2′,4,4,6-pentaBDE (BDE-100) and 2,2,4,4′,5,5′-hexaBDE (BDE-153) in water samples, including drinking, lake, river water and soil samples. Significant quantities of PBDEs were not found in the analyzed samples.  相似文献   

17.
A new line of solid-phase microextraction (SPME) coatings suitable for use with liquid chromatography applications was recently developed to address the limitations of the currently available coatings. The proposed coatings were immobilized on the metal fiber core and consisted of a mixture of proprietary biocompatible binder and various types of coated silica (octadecyl, polar embedded and cyano) particles. The aim of this research was to perform in vitro assessment of these new SPME fibers in order to evaluate their suitability for drug analysis and in vivo SPME applications. The main parameters examined were extraction efficiency, solvent resistance, preconditioning, dependence of extraction kinetics on coating thickness, carryover, linear range and inter-fiber reproducibility. The performance of the proposed coatings was compared against commercial Carbowax-TPR (CW-TPR) coating, when applicable. The fibers were evaluated for the extraction of drugs of different classes (carbamazepine, propranolol, pseudoephedrine, ranitidine and diazepam) from plasma and urine. The analyses were performed using liquid chromatography-tandem mass spectrometry. The results show that the fibers perform very well for the extraction of biological fluids with no sample pre-treatment required and can also be used for in vivo sampling applications of flowing blood. A coating thickness of 45 μm was found to be a good compromise between extraction capacity and extraction kinetics. Due to the high extraction efficiency of these coatings, pre-equilibrium SPME with very short extraction times (2 min) can be employed to increase sample throughput. Inter-fiber reproducibility was ≤11% R.S.D. (n = 10) for model drugs examined in plasma, which is a significant improvement over polypyrrole coatings reported in literature, and permits single fiber use for in vivo applications.  相似文献   

18.
A new, efficient, and environmental friendly hollow fiber liquid phase microextraction (HF-LPME) method based on supramolecular solvents was developed for extraction of five benzodiazepine drugs. The supramolecular solvent was produced from coacervation of decanoic acid aqueous vesicles in the presence of tetrabutylammonium (Bu4N+). In this work, benzodiazepines were extracted from aqueous samples into a supramolecular solvent impregnated in the wall pores and also filled inside the porous polypropylene hollow fiber membrane. The driving forces for the extraction were hydrophobic, hydrogen bonding, and π-cation interactions between the analytes and the vesicular aggregates. High-performance liquid chromatography with photodiode array detection (HPLC-DAD) was applied for separation and determination of the drugs. Several parameters affecting the extraction efficiency including pH, hollow fiber length, ionic strength, stirring rate, and extraction time were investigated and optimized. Under the optimal conditions, the preconcentration factors were obtained in the range of 112–198. Linearity of the method was determined to be in the range of 1.0–200.0 μg L−1 for diazepam and 2.0–200.0 μg L−1 for other analytes with coefficient of determination (R2) ranging from 0.9954 to 0.9993. The limits of detection for the target benzodiazepines were in the range of 0.5–0.7 μg L−1. The method was successfully applied for extraction and determination of the drugs in water, fruit juice, plasma and urine samples and relative recoveries of the compounds studied were in the range of 90.0–98.8%.  相似文献   

19.
A solid-phase microextraction (SPME) fiber coated with single walled carbon nanotubes (SWCNTs) was prepared by electrophoretic deposition and treated at 500 °C in H2 stream. In order to evaluate the characteristics of the obtained fiber, it was applied in the headspace solid-phase microextraction (HS-SPME) of benzene, toluene, ethylbenzene and xylenes (BTEX) from water sample and quantification by gas chromatography with flame ionization detection (GC-FID). The results indicated that the thermal treatment with H2 enhanced the extraction of the SWCNTs fiber for BTEX significantly. Thermal stability and durability of the fiber were also investigated, showing excellent stability up to 350 °C and life time over 120 times. In the comparison with the commercial CAR–PDMS fiber, the SWCNTs fiber showed similar and higher extraction efficiencies for BTEX. Under the optimized conditions, the linearity, LODs (S/N = 3) and LOQs (S/N = 10) of the method based on the SWCNTs fiber were 0.5–50.0, 0.005–0.026 and 0.017–0.088 μg/L, respectively. Repeatability for one fiber (n = 3) was in the range of 1.5–5.6% and fiber-to-fiber reproducibility (n = 3) was in the range of 4.2–8.3%. The proposed method was successfully applied in the analysis of BTEX compounds in seawater, tap water and wastewater from a paint plant.  相似文献   

20.
This paper describes a simultaneously performed two-/three-phase hollow-fiber-based liquid-phase microextraction (HF-LPME) method for the determination of aromatic amines with a wide range of pKa (−4.25 to 4.6) and log KOW (0.9–2.8) values in environmental water samples. Analytes including aniline, 4-nitroaniline, 2,4-dinitroaniline and dicloran were extracted from basic aqueous samples (donor phase, DP) into the microliter volume of organic membrane phase impregnated into the pores of the polypropylene hollow fiber wall, then back extracted into the acidified aqueous solution (acceptor phase, AP) filling in the lumen of the hollow fiber. The mass transfer of the analytes from the donor phase through the organic membrane phase into acceptor phase was driven by both the counter-coupled transport of hydrogen ions and the pH gradient. Afterwards, the hollow fiber was eluted with 50 μL methanol to capture the analytes from both the organic membrane and the acceptor phase. Factors relevant to the enrichment factors (EFs) were investigated. Under the optimized condition (DP: 100 mL of 0.1 M NaOH with 2 M Na2SO4; organic phase: di-n-hexyl with 8% trioctylphosphine oxide (TOPO); AP: 10 μL of 8 M HCl; extraction time of 80 min), the obtained EFs were 405–2000, dynamic linear ranges were 5–200 μg/L (R > 0.9976), and limits of detection were 0.5–1.5 μg/L. The presence of humic acid (0–25 mg/L dissolved organic carbon) had no significant effect on the extraction efficiency. The proposed procedure worked very well for real environmental water samples with microgram per liter level of analytes, and good spike recoveries (80–103%) were obtained.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号