首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 687 毫秒
1.
We report the development of a microfabricated gas chromatography system suitable for the separation of volatile organic compounds (VOCs) and compatible with use as a portable measurement device. Hydrofluoric acid etching of 95 × 95 mm Schott B270 wafers has been used to give symmetrical hemi-spherical channels within a glass substrate. Two matching glass plates were subsequently cold bonded with the channels aligned; the flatness of the glass surfaces resulted in strong bonding through van der Waals forces. The device comprised gas fluidic interconnections, injection zone and 7.5 and 1.4 m long, 320 μm internal diameter capillaries. Optical microscopy confirmed the capillaries to have fully circular channel profiles. Direct column heating and cooling could be achieved using a combination of resistive heaters and Peltier devices. The low thermal conductivity of glass allowed for multiple uniform temperature zones to be achieved within a single glass chip. Temperature control over the range 10–200 °C was achieved with peak power demand of approximately 25 W. The 7.5 m capillary column was static coated with a 2 μm film of non-polar dimethylpolysiloxane stationary phase. A standard FID and a modified lightweight 100 mW photoionization detector (PID) were coupled to the column and performance tested with gas mixtures of monoaromatic and monoterpene species at the parts per million concentration level. The low power GC-PID device showed good performance for a small set of VOCs and sub ng detection sensitivity to monoaromatics.  相似文献   

2.
Flash gas chromatographic (GC) analysis of 15 organophosphorus pesticides commonly occurring in food crops was performed using the Thermedics Detection EZ Flash upgrade kit installed in the oven of a HP 5890 Series II Plus gas chromatograph. The temperature program and splitless time period were the main parameters to be optimized. In the first set of experiments wheat matrix-matched standards were analyzed both by: (i) the flash GC technique (resistive heating of a 5 m capillary column), and (ii) the conventional GC technique (moderate oven temperature programming of a 30 m capillary column). Using the flash GC technique, the analysis time was reduced by a factor of more than 10 compared to the conventional GC technique. Dramatically improved detectability of analytes was achieved due to much narrower peak widths. The flash GC technique was compared with another approach to faster GC analysis employing a 5 m column and fast temperature programming with a conventional GC oven. In comparison with this alternative, in the case of flash GC significantly better retention time repeatability was observed. The other superiority of resistive heating is very rapid cooling down (i.e., equilibration to the initial conditions) which contributes to the increased sample throughput.  相似文献   

3.
A practical investigation of frictional heating effects in conventional C18 columns was undertaken, to investigate whether problems found for sub-2 μm columns were also present for those of particle size 3 μm and 5 μm and different internal diameter. The influence of a water bath, a still air heater, and a forced air heater on performance was investigated. Heating effects were substantial, with a decrease in k of almost 15% for toluene over the flow rate range ∼0.4–2.3 mL/min with a 15 cm × 0.46 cm ID column packed with 3 μm particles. Heating effects on retention increased with increasing solute k, with increase in the column ID, with decrease in the column particle size, and with decrease in the set column oven temperature. While the water bath minimised axial temperature gradients and thus its effect on k, radial temperature gradients were potentially serious with this system, especially at high mobile phase velocity, even with columns containing 5 μm particles. In contrast to the effects of axial temperature gradients in 4.6 mm columns, very little difference in Van Deemter plots was noted between the three different thermostats with 2 mm ID columns, even when 3 μm particles were used. However, the efficiency of 2 mm columns for peaks of low or moderate k (k < 4) can be compromised by the extra dead volume introduced by the heating systems, even with conventional HPLC systems with otherwise minimised extra column volume.  相似文献   

4.
《Thermochimica Acta》2006,448(1):31-36
In this study, dehydration of sodium carbonate monohydrate (Na2CO3·H2O) (SCM) in microwave (MW) field with silicon carbide (SiC) as an indirect heating medium was investigated. SCM samples containing up to 3% free moisture were placed in the microwave oven. The heating experiments showed that SCM is a poor microwave energy absorber for up to 6 min of irradiation at an 800 W of microwave power. The heat for SCM calcination is provided by SiC which absorbs microwave. The monohydrate is then converted to anhydrous sodium carbonate on the SiC plate by calcining, i.e. by removing the crystal water through heating of the monohydrate temperatures of over 120 °C. The calcination results in a solid phase recrystallization of the monohydrate into anhydrate. In the microwave irradiation process, dehydration of SCM in terms of indirect heating can be accelerated by increasing the microwave field power.  相似文献   

5.
Poly(vinyl chloride) (PVC) was decomposed by microwave (MW) irradiation (2.45 GHz) using a commercial MW oven. The efficiency of dielectric absorption was evaluated quantitatively from the rate of temperature increase on MW irradiation. The efficiency of dielectric heating increased at temperatures above the glass transition temperature (Tg). The decomposition on MW irradiation, monitored using the weight, depended on the initial (preheating) temperature of the sample before irradiation. The degradation time profile with various initial temperatures was shifted along the time axis and was successfully superimposed on a single curve. A pure PVC film was subjected to heating at a constant temperature from 230 °C to 310 °C, and the rate of weight decrease on heating was measured. The apparent activation energy was 84.4 kJ/mol for a single monomer unit.  相似文献   

6.
7.
A new growth recipe for producing carbon nanotubes (CNTs) combined with a new bonding technique was implemented in a microfabricated gas chromatography (micro-GC) chip. Specifically, the micro-GC chip contained a 30-cm (length) microfabricated channel with a 50 μm × 50 μm square cross-section. A CNT stationary phase “mat” was grown on the bottom of the separation channel prior to the chip bonding. Injections onto the micro-GC chip were made using a previously reported high-speed diaphragm valve technique. A FID was used for detection with a high-speed electrometer board. All together, the result was a highly efficiency, temperature programmable (via low thermal mass, rapid on-chip resistive heating) micro-GC chip. In general, the newly designed micro-GC chip can be operated at significantly lower temperature and pressure than our previously reported micro-GC chip, while producing excellent chemical separations. Scanning electron microscopy (SEM) images show a relatively thin and uniform mat of nanotubes with a thickness of ∼800 nm inside the channel. The stationary phase was further characterized using Raman spectroscopy. The uniformity of the stationary phase resulted in better separation efficiency and peak symmetry (as compared to our previous report) in the separation of a mixture of five n-alkanes (n-hexane, n-octane, n-nonane, n-decane and n-undecane). The on-chip resistive heater employing a temperature programming rate of 26 °C/s produced a peak capacity of eight within a 1.5-s time window.  相似文献   

8.
In order to increase productivity of drug analysis in the pharmaceutical industry, an efficient and sensitive generic static headspace gas chromatography (HSGC) method was successfully developed and validated for the determination of 44 classes 2 and 3 solvents of International Conference of Harmonization (ICH) guideline Q3C, as residual solvents in drug substance. In order to increase the method sensitivity and efficiency in sample equilibration, dimethylsulfoxide (DMSO) was selected as the sample diluent based on its high capacity of dissolving drug substance, stability and high boiling point. The HS sample equilibration temperature and equilibration time are assessed in ranges of 125–150 °C and 8–15 min, respectively. The results indicate that the residual solvents in 200 mg of drug substance can be equilibrated efficiently in HS sampler at 140 °C for 10 min. The GC parameters, e.g. sample split ratio, carrier flow rate and oven temperature gradient are manipulated to enhance the method sensitivity and separation efficiency. The two-stage gradient GC run from 35 to 240 °C, using an Agilent DB-624 capillary column (30 m long, 0.32 mm I.D., 1.8 μm film thickness), is suitable to determine 44 ICH classes 2 and 3 solvents in 30 min. The method validation results indicate that the method is accurate, precise, linear and sensitive for solvents assessed. The recoveries of most of these solvents from four drug substances are greater than 80% within the method determination ranges. However, this method is not suitable for the 10 remaining ICH classes 2 and 3 solvents, because they are too polar (e.g. formic acid and acidic acid), or have boiling points higher than 150 °C, (e.g. anisol and cumene). In comparison with the previous published methods, this method has a much shorter sample equilibration time, a better separation for many solvents, a higher sensitivity and a broader concentration range.  相似文献   

9.
10.
The equilibrium temperature of the solid-solid phase transition of high purity caesium nitrate has been measured accurately by stepwise heating and by the extrapolation to zero heating rate method. A mean value of 154.3 ± 0.1 °C was obtained using two different heat flux DSC instruments. A value of 3.44 ± 0.04 kJ mol−1 was determined for the enthalpy of transition.  相似文献   

11.
High-speed temperature programming is implemented via the direct resistive heating of the separation column (2.3m MXT-5 Silicosteel column with a 180 microm I.D. and a 0.4 microm 5% phenyl/95% dimethyl polysiloxane film). Resistive temperature programming was coupled with synchronized dual-valve injection (with an injection pulse width of 2 ms), producing a complete high-speed gas chromatography (GC) system. A comparison of isothermal and temperature programmed separations of seven n-alkanes (C(6) and C(8)-C(13)) shows a substantial improvement of peak width and peak capacity with temperature programming. The system was further implemented in separations of a mixture of analytes from various chemical classes. Separations of the n-alkane mixture using three different temperature programming rates are reported. A temperature programming rate as high as 240 degrees C/s is demonstrated. The method for determination of temperature programming rate, based on isothermal data, is discussed. The high-speed resistive column heating temperature programming resulted in highly reproducible separations. The highest rate of temperature programming (240 degrees C/s) resulted in retention time and peak width RSD, on average, of 0.5 and 1.4%, respectively, for the n-alkane mixture. This high level of precision was achieved with peak widths-at-half-height ranging from 13 to 36 ms, and retention times ranging from 147 to 444 ms (for n-hexane to n-tridecane).  相似文献   

12.
New hyphenated technique for the extraction and determination of isoflavones in sea and freshwater algae and cyanobacteria was developed. The method consists of sonication sample pretreatment, extraction by supercritical CO2 modified by 3% (v/v) of MeOH/H2O mixture (9:1, v/v) at 35 MPa and 40 °C for 60 min, fast chromatography analysis by the means of Agilent 1200 Series Rapid Resolution and MS/MS determination. Agilent 1200 Series RRLC was used with Zorbax SB-CN chromatographic column (100 mm × 2.1 mm, particle size 3.5 μm), 3 μl injection volume, mobile phase consisting of 0.2% (v/v) acetic acid in water (solvent A) and acetonitrile (solvent B) and used with linear gradient (30% B at 0 min, from 0 min to 3 min up to 50% B, from 3 to 6 min up to 80% B and from 6 to 10 min down to 30% B). The flow-rate was 0.4 mL/min, column oven temperature 35 °C. MS detector Agilent Technologies 6460 Triple quadrupole LC/MS with Agilent Jet Stream was used in a negative ESI mode under following conditions: gas temperature 350 °C, gas flow 13 L/min, nebulizer gas pressure 50 psi, sheath gas temperature 400 °C, sheath gas flow 12 L/min, capillary voltage was 4 kV. Samples were analysed in the multiple reaction monitoring (MRM) mode. Eight isoflavone compounds were found for the first time in seven real samples of sea algae and in three control samples of freshwater algae and cyanobacteria. Usual optimisation study of extraction parameters was performed. Pressure and temperature optima for algae matrix are different from those obtained sooner for other matrices for most of the analytes, but the results of modifier optimisation study are in good accordance with those obtained sooner for spiked samples and red clover matrix. It seems that matrix has very small or no effect on the modifier selection. Two different approaches of sonication pretreatment were tested: sonication bath and the thorn instrument. In longer extraction time experiments, thorn sonication was more efficient and recovery of following supercritical fluid extraction was higher.  相似文献   

13.
Recently, hydrophilic interaction chromatography (HILIC) has emerged as a valuable orthogonal tool to reversed-phase liquid chromatography (RP-LC) as it allows for resolution of highly polar ionisable compounds. The relationships between separation efficiency, column length and speed of analysis for 4.6 mm ID × 5 μm silica particle columns in HILIC are demonstrated using kinetic plots. The kinetic plots constructed for conventional pressure systems operating at 350 bar and at 30 °C and 80 °C are confirmed using experimental data for different column lengths. Efficiencies of more than 130,000 theoretical plates could be achieved by connecting up to six columns of 25 cm. As expected, a significant gain in analysis speed without loss of efficiency could be obtained by operating at 80 °C compared to 30 °C. The advantages of using long columns in HILIC in combination with elevated column temperature for the pharmaceutical industry are illustrated using test mixtures comprised of commercially available ionisable compounds (including some containing functional groups with potential genotoxic typical structural alerts) as well as real polar ionisable pharmaceuticals.  相似文献   

14.
The influence of various parameters on the kinetics of poly(ethylene terephthalate) (PET) glycolysis by diethylene glycol (DEG), namely temperature (from 190 to 220 °C), temperature profile, catalysis and PET morphology has been studied.The results showed a strong influence of some experimental conditions (temperature and catalysis) on the mixture evolution during depolymerisation. The temperature study showed a critical temperature between 210 and 220 °C which seems to be the consequence of a better diffusion of DEG in PET, allowing easier reactions in solid phase. The initial morphology of PET scraps does not affect the rates of reactions much, in contrast to the temperature profile which has a great importance: time of PET dissolution at 220 °C is considerably shorter by heating PET and DEG separately at 220 °C before mixing, than by heating a cold mixture of the two reagents to 220 °C.  相似文献   

15.
Nanosized aluminum nitride hollow spheres were synthesized by simply heating aluminum nanoparticles in ammonia at 1000 °C. The as-synthesized sphere shells are polycrystalline with cavity diameters ranging from 15 to 100 nm and shell thickness from 5 to 15 nm. The formation mechanism can be explained by the nanoscale Kirkendall effect, which results from the difference in diffusion rates between aluminum and nitrogen. The Al nanoparticles served as both reactant and templates for the hollow sphere formation. The effects of precursor particle size and temperature were also investigated in terms of product morphology. Room temperature cathode luminescence spectrum of the nanosized hollow spheres showed a broad emission band centered at 415 nm, which is originated from oxygen related luminescence centers. The hollow structure survived a 4-h heat treatment at 1200 °C, exhibiting excellent thermal stability.  相似文献   

16.
In this work the thermal decomposition characteristics of micron sized aluminum powder + potassium perchlorate pyrotechnic systems were studied with thermal analytical techniques. The results show that the reactivity of aluminum powder in air increases as the particle size decreases. Pure aluminum with 5 μm particle size has a fusion temperature about 647 °C, but this temperature for 18 μm powder is 660 °C. Pure potassium perchlorate has an endothermic peak at 300 °C corresponding to a rhombic-cubic transition, a fusion temperature around 590 °C and decomposes at 592 °C. DTA curves for Al5/KClO4 (30:70) mixture show a maximum peak temperature for thermal decomposition at 400 °C. Increasing the particle size of aluminum powder increases the ignition temperature of the mixture. The oxidation temperature increased by enhance in the aluminum content of the mixture.  相似文献   

17.
In this study, the usability of the plant thistle, Onopordum acanthium L., belonging to the family Asteraceae (Compositae), in liquid fuel production has been investigated. The experiments were performed in a fixed-bed Heinze pyrolysis reactor to investigate the effects of heating rate, pyrolysis temperature and sepiolite percentage on the pyrolysis product yields and chemical compositions. Experiments were carried out in a static atmosphere with a heating rate of 7 °C/min and 40 °C/min, pyrolysis temperature of 350, 400, 500, 550 and 700 °C and particle size of 0.6 < Dp < 0.85 mm. Catalyst experiments were conducted in a static atmosphere with a heating rate of 40 °C/min, pyrolysis temperature of 550 °C and particle size of 0.6 < Dp < 0.85 mm. Bio-oil yield increased from 18.5% to 27.3% with the presence of 10% of sepiolite catalyst at pyrolysis temperature of 550 °C, with a heating rate of 40 °C/min, and particle size of 0.6 < Dp < 0.85 mm. It means that the yield of bio-oil was increased at around 48.0% after the catalyst added. Chromatographic and spectroscopic studies on the bio-oil showed that the oil obtained from O. acanthium L. could be used as a renewable fuels and chemical feedstock.  相似文献   

18.
Nickel nanoparticles were prepared and uniformly supported on multi-walled carbon nanotubes (MWCNTs) by reduction route with CNTs as a reducing agent at 600 °C. As-prepared nickel nanoparticles were single crystalline with a face-center-cubic phase and a size distribution ranging from 10 to 50 nm, and they were characterized by transmission electron microscopy (TEM), high-resolution TEM and X-ray diffraction (XRD). These nickel nanoparticles would be coated with graphene layers, when they were exposed to acetylene at 600 °C. The coercivity values of nickel nanoparticles were superior to that of bulk nickel at room temperature.  相似文献   

19.
Bimetallic Ni-Cu particles were synthesized from either suspensions of nickel carbonate and copper carbonate, and solutions of nickel nitrate and copper nitrate in ethylene glycol which acts both as solvent and reducing agent. The nature and composition of the powders depend on both the reaction temperature and time, and the reactants. Using the carbonates, bimetallic Ni-Cu powders composed of a nickel-rich and a copper-rich solid solution were obtained after 39 h at 140°C. Increasing the reaction temperature to 190°C gives a Ni-Cu powder composed of a copper-rich solid solution and nickel. Particles obtained under these conditions, however, are polydisperse. The nitrate solution gave bimetallic Ni-Cu particles with a narrow size distribution of about 140 nm after 4 h of reaction at 196°C. These particles are made of a copper core and a nickel shell. The mechanism of bimetallic particle formation is controlled by the solubility of the reactants, the formation of intermediate metal glycolates and Cu2O, and the required reduction temperature.  相似文献   

20.
Oxidation of aniline by emulsion polymerization pathway using benzoyl peroxide oxidant in the presence of fluoroboric acid and sodium lauryl sulfate surfactant leads to incorporation of both acid group as well as surfactant group onto the polyaniline chain as dopants i.e. formation of polyaniline-fluoroboric acid-dodecylhydrogensulfate salt (PANI-HBF4-DHS). Amount of dopants such as fluoroboric acid (HBF4), dodecylhydrogensulfate (DHS) and water present in the PANI-HBF4-DHS was found out for the first time. Electrochemical activity and rheological stability of the polymer were determined. Thermal stability of PANI-HBF4-DHS was determined by subjecting the polyaniline salt in macroscale at four different temperatures (100, 150, 200 and 250 °C). Structure, composition and thermal stability of polyaniline salt were determined by chemical analysis, conductivity, IR, UV/vis, XRD spectral measurements from the heat treated samples. Polyaniline salt contains 8.3 wt% water, 22.4 wt% HBF4 and 15.4 wt% DHS at ambient temperature. Upon vacuum, polyaniline salt loses 4.7 wt% water and on heating the sample at 100 °C it loses the remaining 3.6 wt% water. On further heating polyaniline salt loses its dopants and at 250 °C it loses both the dopants almost completely. Polyaniline salt on heating undergoes cross-linking even at 100 °C and however, conductivity (3 × 10−2 S/cm) of polyaniline salt was found to remain almost the same up to 150 °C.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号