首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 218 毫秒
1.
Li G  Zhang X  You J  Song C  Sun Z  Xia L  Suo Y 《Analytica chimica acta》2011,(2):2411-218
Oleanolic acid (OA) and ursolic acid (UA) are the ubiquitous triterpenic acids in plant kingdom and have multiple biological effects. In the present study, a highly sensitive and selective method using a dual-sensitive probe 2-(5-benzoacridine)ethyl-p-toluenesulfonate (BAETS) as pre-column labeling reagent has been developed for rapid determination of the triterpenes OA and UA by HPLC with fluorescence detection (FLD) and online mass spectrometry identification. Response surface methodology as an efficient tool was employed to optimize the ultrasonic-assisted extraction of triterpenic acids from Swertia plants and the pre-column derivatization reaction, respectively, which ensured the highest triterpenic acids recoveries within the shortest extraction time and the sufficient labeling of the analyzed components. Fast separation of the isomers OA and UA could be achieved on a Hypersil BDS C8 column within 7 min. Both of OA and UA gave the good correlation coefficients of 0.9999. This developed method offered the satisfactory detection limits of 1.10 and 1.30 ng mL−1 for UA and OA, respectively. When applied to Swertia species, it showed good reproducibility.  相似文献   

2.
A method using high‐performance liquid chromatography coupled with tandem mass spectrometry was developed for the simultaneous determination of organic acids in microalgae. o‐Benzylhydroxylamine was used to derivatize the analytes, and stable isotope‐labeled compounds were used as internal standards for precise quantification. The proposed method was evaluated in terms of linearity, recovery, matrix effect, sensitivity, and precision. Linear calibration curves with correlation coefficients >0.99 were obtained over the concentration range of 0.4–40 ng/mL for glycolic acid, 0.1–10 ng/mL for malic acid and oxaloacetic acid, 0.02–2 ng/mL for succinic acid and glyoxylic acid, 4–400 ng/mL for fumaric acid, 20–2000 ng/mL for isocitric acid, 2–200 ng mL−1 for citric acid, 100–10000 ng mL−1 for cis‐aconitic acid, and 1–100 ng mL−1 for α‐ketoglutaric acid. Analyte recoveries were between 80.2 and 115.1%, and the matrix effect was minimal. Low limits of detection (0.003–1 ng/mL) and limits of quantification (0.01–5 ng/mL) were obtained except cis‐aconitic acid. Variations in reproducibility for standard solution at three different concentrations levels were <9%. This is the first report of the simultaneous analysis of ten organic acids in microalgae, which promotes better understanding of their growth state and provides reference value for high‐yield microalgae cultures.  相似文献   

3.
An accurate, sensitive and least time consuming reverse phase high performance liquid chromatographic (RP‐HPLC) method for the estimation of captopril in the presence of non steroidal anti‐inflammatory drugs in formulation and human serum has been developed and validated. Chromatographic separation was conducted on prepacked Purospher star C18 (5 μm, 25 × 0.46 cm) column at room temperature using methanol:water (80:20 v/v) as a mobile phase, pH adjusted at 2.8 with o‐phosphoric acid and at a flow rate of 1.0 mL min−1, while UV detection was performed at 227 nm. The limit of detection and quantification for captopril were 1 and 0.35 ng mL−1, while that for (NSAID's) i.e. flurbiprofen, ibuprofen, diclofenac sodium and mefenamic acid LOD were 0.2, 1, 2 and 0.4 ng mL−1 respectively and LOQ were 0.9, 2.9, 8 and 1 ng mL−1 Analytical recovery was > 98.1%. The method used for the quantitative analysis of commonly administered non steroidal anti‐inflammatory drugs (NSAID's) i.e. ibuprofen, flurbiprofen, diclofenac sodium and mefenamic acid alone or in combination with captopril from API (active pharmaceutical ingredients), dosage formulations and in human serum. The established method is rapid (RT < 12 min), accurate (recovery > 98.1%), selective (no interference of excepients and other commonly used drugs and food) and sensitive (LOQ 3.5 ng mL;‐1) and reproducible (SD ± 0.003).  相似文献   

4.
《Electroanalysis》2017,29(10):2348-2357
This work describes a simple preparation of 1‐diazo‐2‐naphthol‐4‐sulfonic acid (1,2,4‐acid) and multiwalled carbon nanotubes (MWCNTs) modified glassy carbon electrode (GCE) for the simultaneous detection of Co(II) and Cu(II). MWCNTs, with their good conductivity and large surface area, were drop‐casted onto the surface of the GCE prior to the electrodeposition of 1,2,4‐acid, a metal chelating agent. Co(II) and Cu(II) were simultaneously measured by differential pulse anodic stripping voltammetry (DPASV) in a batch system. Under optimum conditions, the linear range of Co(II) was between 0.10 and 2.5 μg mL−1 with an LOD of 80 ng mL−1. Two linear ranges were obtained for Cu(II), 0.0050 to 0.030 μg mL−1 and 0.040 to 0.25 μg mL−1,with an LOD of 2.4 ng mL−1. The method offered a high operational stability for up to 52 measurements (RSD=3.4 % for Co(II) and 2.6 % for Cu(II)) and good reproducibility (RSD=1.2 % for Co(II) and 1.7 % for Cu(II)). In the simultaneous detection of Co(II) and Cu(II), there was no effect from common interferences found in wastewater. The method was successfully applied in real water samples with good recoveries (88.2±0.8 to 102.0±0.8 % for Co(II) and 96.5±0.4 to 103.8±0.9 % for Cu(II)) and the results were in good agreement with those obtained from inductively coupled plasma optical emission spectrometry (ICP‐OES) (P >0.05).  相似文献   

5.
For the analysis of edible oils, saponification is well known as a useful method for eliminating oil matrices. The conventional approach is conducted with alcoholic alkali; it consumes a large volume of organic solvents and impedes the retrieval of analytes by microextraction. In this study, a low‐organic‐solvent‐consuming method has been developed for the analysis of benzo[a]pyrene in edible oils by high‐performance liquid chromatography with fluorescence detection. Sample treatment involves aqueous alkaline saponification, assisted by a phase‐transfer catalyst, and selective in situ extraction of the analyte with a supramolecular solvent. Comparison of the chromatograms of the oil extracts obtained by different microextraction methods showed that the supramolecular solvent has a better clean‐up effect for the unsaponifiable matter from oil matrices. The method offered excellent linearity over a range of 0.03– 5.0 ng mL−1 (r > 0.999). Recovery rates varied from 94 to 102% (RSDs <5.0%). The detection limit and quantification limit were 0.06 and 0.19 μg kg−1, respectively. The proposed method was applied for the analysis of 52 edible oils collected online in China; the analyte contents of 23 tested oil samples exceeded the maximum limit of 2 μg kg−1 for benzo[a]pyrene set by the Commission Regulation of the European Union.  相似文献   

6.
A rapid and sensitive reversed-phase high performance liquid chromatography– fluorescence-mass spectrometer (RP-HPLC–FLD-MS) method based on pre-column derivatization using 2-(5-benzoacridine)ethyl-p-toluenesulfonate (BAETS) as labelling reagent has been developed for simultaneous determination of five triterpenic acids (asiatic acid (AA), maslinic acid (MA), corosolic acid (CA), oleanolic acid (OA), and betulinic acid (BA). The presented method was validated for linearity (correlation coefficient R2 > 0.9994), precision (RSD 2.1%–3.9%) and reproducibility (RSD 0.01%–2.1%). The limits of detection (LODs) and the limits of quantitation LOQs were within the range of 0.71–1.02 ng mL?1 and 2.28–3.24 ng mL?1, respectively. The proposed method was successfully applied to simultaneously determine five triterpenic acids of four Corydalis plants and showed satisfactory reproducibility and credibility. Moreover, several main parameters affecting extraction procedure and derivatization efficiency were investigated by response surface methodology (RSM), respectively. Triterpenic acid content in four Corydalis plants was measured according to the established method and the results indicated that triterpenic acid contents were various in different organs and herbs.  相似文献   

7.
A method for the simultaneous determination of aluminum (Al), cadmium (Cd) and lead (Pb) in whole blood has been developed by using simultaneous atomic absorption spectrometry (SIMAAS) with oxygen charring. The optimized conditions for the simultaneous determination of Al, Cd and Pb were obtained in the presence of palladium (Pd) as the chemical modifier, using 600 °C and 2400 °C as the pyrolysis and the atomization temperature, respectively. The whole blood samples were diluted 1+5 (v/v) directly with 0.1% (v/v) Triton X‐100. Oxygen was employed to eliminate the interference of carbonaceous residues in the charring step before pyrolysis. The calibration curves were carried out with aqueous standard solutions and the linear ranges were 0–40 ng mL−1, 0–4 ng mL−1 and 0–40 ng mL−1 for Al, Cd and Pb, respectively. The detection limits were 0.96 ng mL−1 (19.2 pg) for Al, 0.03 ng mL−1 (0.6 pg) for Cd and 0.60 ng mL−1 (12.0 pg) for Pb. The spiked recoveries of Al, Cd and Pb in whole blood were 98.0%, 100.0% and 101.7%, respectively. The accuracy of the proposed method was evaluated with the analysis of a whole blood certified reference material (Seronorm, level 2). The found concentrations were in agreement with the recommended values. The proposed method has been successfully applied to the simultaneous determination of Al, Cd and Pb in whole blood of healthy volunteers before and after eating barbecued foods.  相似文献   

8.
Senkyunolide I is one of the major bioactive components in the herbal medicine Ligusticum chuanxiong. The aim of this study was to develop and validate a fast, simple and sensitive LC‐MS/MS method for the determination of senkyunolide I in dog plasma. The plasma samples were processed with acetonitrile and separated on a Waters Acquity UPLC BEH C18 column (50 × 2.1 mm, 1.7 μm). The mobile phase consisted of 0.1% formic acid aqueous and acetonitrile was delivered at a flow rate of 0.3 mL min−1. The detection was achieved in the positive selected reaction monitoring mode with precursor‐to‐product transitions at m/z 225.1 → 161.1 for senkyunolide I and at m/z 349.1 → 305.1 for an internal standard. The assay was linear over the tested concentration range, from 0.5 ng mL−1 to 1000 ng mL−1, with a correlation coefficient >0.9992. The mean extraction recovery from dog plasma was within the range of 85.78–93.25%, while the matrix effect of the analyte was within the range of 98.23–108.89%. The intra‐ and inter‐day precisions (RSD) were <12.12% and the accuracy (RR) ranged from 98.89% to 104.24%. The validated assay was successfully applied to pharmacokinetic and bioavailability studies of senkyunolide I in dogs. The results demonstrated that (a) senkyunolide I showed short elimination half‐life (<1 h) in dog, (b) its oral bioavailability was >40% and (c) senkyunolide I showed dose‐independent pharmacokinetic profiles in dog plasma over the dose range of 1–50 mg kg−1.  相似文献   

9.
《Analytical letters》2012,45(11):1988-2000
Abstract

A novel, selective, and sensitive magnetic-mimetic enzyme fluorescence immunoassay method for antigen detection has been developed by taking advantage of a magnetic separation process and the amplification feature of the hemin label. This method is based on a twice amplified fluorescence signal. The signal is first amplified due to the ultrasmall size and the high surface-to-volume ratio of the silica-coated magnetite nanoparticles, which enable the nanoparticles to carry much more antibodies. Second, the mimetic enzyme (hemin) as a labeling reagent catalyzes the reaction of p-hydroxyphenyl acetic acid and H2O2 can further amplify the fluorescence signal. This protocol was also evaluated for a sandwich-type immunoassay of human IgG, and the calibration graph for human IgG was linear over the range of 0–100 ng mL?1 with a detection limit of 9.8 ng mL?1. This method can easily separate magnetic nanoparticles from the solution, which simplified the process and played a promising role for various applications in immunoassay.  相似文献   

10.

Taurine is an amino acid which is not incorporated into proteins but found in the cytosol of many mammalian cells, in high concentrations (2–30 mM). Increase in plasma taurine concentration has already been reported after surgical trauma, X-radiation, muscle necrosis, carbon tetrachloride-induced liver damage, and paracetamol overdose. Plasma taurine concentration was measured using LC with fluorescence detection following derivatization by o-phtalaldehyde plus 3-mercapto-propionic acid and α-aminobutyric acid as internal standard. Under these conditions the retention time of taurine was 10 min. This method was sensitive enough, to quantify 150 pg mL−1 and detect 50 pg mL−1 of taurine ranging normally between 65 and 179 mmol L−1 (8–22 μg mL−1). The validated method allowed simple determination of human plasma taurine in pharmacokinetic and biomarker studies.

  相似文献   

11.
The detection of viruses is of interest for a number of fields including biomedicine, environmental science, and biosecurity. Of particular interest are methods that do not require expensive equipment or trained personnel, especially if the results can be read by the naked eye. A new “double imprinting” method was developed whereby a virus‐bioimprinted hydrogel is further micromolded into a diffraction grating sensor by using imprint‐lithography techniques to give a “Molecularly Imprinted Polymer Gel Laser Diffraction Sensor” (MIP‐GLaDiS). A simple laser transmission apparatus was used to measure diffraction, and the system can read by the naked eye to detect the Apple Stem Pitting Virus (ASPV) at concentrations as low as 10 ng mL−1, thus setting the limit of detection of these hydrogels as low as other antigen‐binding methods such as ELISA or fluorescence‐tag systems.  相似文献   

12.
A sequential online extraction, clean‐up and separation system for the determination of betaine, l ‐carnitine and choline in human urine using column‐switching ion chromatography with nonsuppressed conductivity detection was developed in this work. A self‐packed pretreatment column (50 × 4.6 mm, i.d.) was used for the extraction and clean‐up of betaine, l ‐carnitine and choline. The separation was achieved using self‐packed cationic exchange column (150 × 4.6 mm, i.d.), followed by nonsuppressed conductivity detection. Under optimized experimental conditions, the developed method presented good analytical performance, with excellent linearity in the range of 0.60–100 μg mL−1 for betaine, 0.75–100 μg mL−1 for l ‐carnitine and 0.50–100 μg mL−1 for choline, with all correlation coefficients (R2) >0.99 in urine. The limits of detection were 0.15 μg mL−1 for betaine, 0.20 μg mL−1 for l ‐carnitine and 0.09 μg mL−1 for choline. The intra‐ and inter‐day accuracy and precision for all quality controls were within ±10.32 and ±9.05%, respectively. Satisfactory recovery was observed between 92.8 and 102.0%. The validated method was successfully applied to the detection of urinary samples from 10 healthy people. The values detected in human urine using the proposed method showed good agreement with the measurement reported previously.  相似文献   

13.
New research has indicated that Gastrodiae Rhizome (GR) has potential anti‐diabetic and anti‐asthmatic effects in mouse models. On the basis of our previous study of the relative bioavailability of gastrodin (GAS) and parishin (PA) from extract and powder of GR, we performed further research on the tissue distribution and excretion of the two analytes. A reliable bioanalytical method for the quantification of GAS and PA in rat tissues and excretion is required. Chromatographic separation was carried out on a gradient mobile phase of acetonitrile–water with 0.1% formic acid. Calibration curves (1/x 2 weighted) offered satisfactory linearity (r 2 > 0.9835) within 100–3000 ng mL−1 for GAS and (r 2 > 0.9862) within 10–1000 ng mL−1 for PA. The relative standard deviations of the intra‐day and inter‐day precision were all <14.98%, whilst the relative errors of the intra‐day and inter‐day accuracy were all within ±14.71%. The matrix effect and recovery values were satisfactory in all of the biological matrices examination. The data of relative differences in tissue distribution and excretion of GAS and PA from powder and extract of GR indicated that higher bioavailabilities for GAS and PA were obtained when a dosage of 4 g kg−1 GR powder was used.  相似文献   

14.
A reliable, high‐throughput and sensitive LC–MS/MS procedure was developed and validated for the determination of five tyrosine kinase inhibitors in human plasma. Following their extraction from human plasma, samples were eluted on a RP Luna®‐PFP 100 Å column using a mobile phase system composed of acetonitrile and 0.01 m ammonium formate in water (pH ~4.1) with a ratio of (50:50, v /v) flowing at 0.3 mL min−1. The mass spectrometer was operating with electrospray ionization in the positive ion multiple reaction monitoring mode. The proposed methodology resulted in linear calibration plots with correlation coefficients values of r 2 = 0.9995–0.9999 from concentration ranges of 2.5–100 ng mL−1 for imatinib, 5.0–100 ng mL−1 for sorafenib, tofacitinib and afatinib, and 1.0–100 ng mL−1 for cabozantinib. The procedure was validated in terms of its specificity, limit of detection (0.32–1.71 ng mL−1), lower limit of quantification (0.97–5.07 ng mL−1), intra‐ and inter assay accuracy (−3.83 to +2.40%) and precision (<3.37%), matrix effect and recovery and stability. Our results demonstrated that the proposed method is highly reliable for routine quantification of the investigated tyrosine kinase inhibitors in human plasma and can be efficiently applied in the rapid and sensitive analysis of their clinical samples.  相似文献   

15.
Protein can greatly enhance the fluorescence of curcumin (CU) in the presence of sodium dodecyl benzene sulfonate (SDBS). Experiments indicate that under the optimum conditions, the enhanced intensity of fluorescence is proportional to the concentration of proteins in the range of 0.0050–20.0 μg mL−1 for bovine serum albumin (BSA), 0.080–20.0 μg mL−1 for human serum albumin (HSA), and 0.040–28.0 μg mL−1 for egg albumin (EA). Their detection limits (S/N=3) are 1.4 ng mL−1, 20 ng mL−1, and 16 ng mL−1, respectively. The method has been satisfactorily used for the determination of proteins in actual samples. In comparison with most of fluorimetric methods, this method is quick and simple, has high sensitivity and good stability. The interaction mechanism is also studied.  相似文献   

16.
A simple and rapid high‐performance liquid chromatographic method with ultraviolet detection was developed for the quantitative determination of retigabine, known also as ezogabine, in human plasma. The assay uses a simple solid‐phase extraction for sample preparation and direct injection of the extract into the chromatograph. Flupirtine is used as an internal standard. Chromatographic separation is achieved on a C18 Chromolith column (Chromolith Performance, 100 × 4.6 mm i.d.), using as mobile phase water/acetonitrile/methanol (72:18:10 v/v/v) mixed with 0.1% of 85% phosphoric acid. Isocratic elution is conducted at a flow rate of 1.5 mL min−1. The total duration of a chromatographic run is 7 min. Calibration curves are linear over the 25–2000 ng mL−1 concentration range, with a limit of quantitation of 25 ng mL−1. Other performance characteristics include high precision (intra‐ and inter‐day coefficients of variation ≤12.6%) and high accuracy (99.7%–108.7%). The method is suitable for the investigation of concentration–response relationships in patients receiving therapeutic doses of retigabine.  相似文献   

17.
For the first time, electrospun composite nanofibers comprising polymeric crown ether with polystyrene (PCE‐PS) have been used for the selective extraction of catecholamines – dopamine (DA), norepinephrine (NE) and epinephrine (E) – prior to their analysis by high‐performance liquid chromatography–electrochemical detection. Using a minicartridge packed with PCE‐PS composite nanofibers, the target compounds were extracted effectively from urine samples to which diphenylborinic acid 2‐aminoethyl ester was added as a complexing reagent. The extracted catecholamines could be liberated from the fiber by the addition of acetic acid. A good linearity was observed for catecholamines in the range of 2.0–200 ng mL?1 (NE, E and DA). The detection limits of catecholamines (signal‐to‐noise ratio = 3) were 0.5 ng mL?1 (NE), 0.2 ng mL?1 (E) and 0.2 ng mL?1 (DA), respectively. Under the optimized conditions, the absolute recoveries of the above three catecholamines were 90.6% (NE), 88.5% (E) and 94.5% (DA). The repeatability of extraction performance was from 5.4 to 9.2% (expressed as relative standard deviation). Our results indicate that the proposed method could be used for the determination of NE, E and DA in urine. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

18.
A simple and rapid reversed-phase HPLC-UV method was developed for the determination of triterpenic acids in the crude extract of Prunellae Spica. Five triterpenic acids were extracted and isolated from P. Spica as marker compounds for use in the quality control of herbal medicines. Various solvent extraction techniques were evaluated, and the greatest efficiency was observed with sonication in 100% ethanol. Elemental compositions of the five marker compounds were determined by high-resolution mass spectroscopy. The dynamic range of the HPLC-UV method depended on the specific analyte, and acceptable quantitation was obtained between 10 and 250 μg mL−1 for oleanolic acid, between 10 and 300 μg mL−1 for ursolic acid, between 3 and 75 μg mL−1 for 2α,3α,24-trihydroxyolean-12en-28oic acid, between 5 and 100 μg mL−1 for euscaphic acid, and between 5 and 100 μg mL−1 for 2α,3α-dihydroxyurs-12en-28oic acid. The method was deemed satisfactory by inter- and intra-day validation and exhibited both high accuracy and precision (relative standard deviation <9.4%). Overall limits of quantitation and detection were approximately 0.5-2.5 μg mL−1 at a signal-to-noise ratio (S/N) of 3 and were about 3.0-10.0 μg mL−1 at a S/N of 10. In addition, principal component analysis (PCA) was performed on the analytical data of 15 different P. Spica samples in order to classify samples collected from different regions.  相似文献   

19.
《化学:亚洲杂志》2017,12(16):2033-2037
The immunochromatographic assay (ICA) using a nitrocellulose (NC) membrane offers several advantages. This technique is a rapid and straightforward method in contrast to other immunoassays. Polydiacetylene (PDA) vesicles have unique optical properties, displaying red color and red fluorescence at the same time. In this system, red‐phase PDA vesicles are used as a fluorescent dye as well as a surface for immobilized hepatitis B surface antibody (HBsAb). PDA has a remarkable stability compared with other fluorescent dyes. In this study, the most suitable PDA/HBsAb complexes are introduced for detecting hepatitis B surface antigen (HBsAg). Then, the PDA/HBsAb complexes affixed antibody is attached to NC membrane, which has two lines to confirm detection of HBsAg. The main advantage of this system is that the detection of HBsAg can be observed in both visible and fluorescent images due to the optical properties of polydiacetylene. Detection of HBsAg is observed up to 0.1 ng mL−1 by fluorescent analysis and confirmed by red line on the NC membrane up to 1 ng mL−1 (HBsAg) using the naked eye. Consequently, these results show that PDA/HBsAb complexes were successfully applied to ICA for the diagnosis of hepatitis B.  相似文献   

20.
A strategy for a fast (ca. 20 min), specific, electrochemical immunoassay for the cardiac biomarker creatine kinase (CK) and the human cytokine interleukin 10 (IL10) has been developed in this paper. The polyaniline modified gold surface formed from electrochemical reduction of diazonium salt supplies a solid substrate to link the activated carboxylic acid groups from the antibodies, which were labelled with ferrocene. The direct electrochemistry of ferrocene allows the analysis of protein markers with good sensitivity. The creatine kinase sensor demonstrates limit of detection of 0.5 pg mL?1 in a physiological Krebs‐Henseleit solution. The anti‐IL10 antibody retained fluorescence activity after further coupling to ferrocene and covalent immobilization on to a gold electrode, showing a linear detection range for IL‐10 from 0.001 ng mL?1 to 50 ng mL?1 in PBS. We attribute the high sensitivity to the well‐controlled modified surface which results in end–on antibodies that can specifically capture the antigen with ease.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号