首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 801 毫秒
1.
High corrosion resistance Cu/Ni-P coatings were electrodeposited on AZ91D magnesium alloy via suitable pretreatments, such as one-step acid pickling-activation, once zinc immersion and environment-friendly electroplated copper as the protective under-layer, which made Ni-P deposit on AZ91D Mg alloy in acid plating baths successfully. The pH value and current density for Ni-P electrodeposition were optimized to obtain high corrosion resistance. With increasing the phosphorous content of the Ni-P coatings, the deposits were found to gradually transform to amorphous structure and the corrosion resistance increased synchronously. The anticorrosion ability of AZ91D Mg alloy was greatly improved by the amorphous Ni-P deposits, which was investigated by potentiodynamic polarization curve and electrochemical impedance spectroscopy (EIS). The corrosion current density (Icorr) of the coated Mg alloy substrate is about two orders of magnitude less than that of the uncoated.  相似文献   

2.
The molybdenum/lanthanum-based (Mo/La) composite conversion coating on AZ31 magnesium alloy was investigated and the corrosion resistance was evaluated as well. The morphology, composition and corrosion resistance of the coating were studied by scanning electron microscopy (SEM), X-ray photoelectron spectroscopy (XPS), and potentiodynamic polarization analysis, respectively. The results revealed that the conversion coating consisted of spherical nodular particles, which was mainly composed of Mo, La, O and Mg. After conversion treatment the corrosion potential shifts about 500 mV positively, and the corrosion current density decreases two orders of magnitude. The corrosion resistance of AZ31 alloy is remarkably improved by Mo/La composite conversion coating.  相似文献   

3.
Pre-treatments based on different cerium salts were applied to the AZ31 Mg alloy. The pre-treatments were performed by immersion in solutions of various Ce(III) salts: cerium chloride, cerium nitrate, cerium sulphate and cerium phosphate. The chemical composition of the treated surfaces was investigated by X-ray photoelectron spectroscopy and Auger electron spectroscopy, whereas the corrosion behaviour of the pre-treated AZ31 substrates was investigated in 0.005 M NaCl solutions using potentiodynamic polarisation and open circuit potential monitoring. The surface film contained a mixture of Ce(IV) and Ce(III) salts. The film thickness depends upon the cerium salt used. The electrochemical results show that all the conversion pre-treatments reduced the corrosion activity of the AZ31 Mg alloy substrates in the presence of chloride ions. The corrosion protection efficiency is related with the anion present in the cerium salt.  相似文献   

4.
The effect of zinc immersion and the role of fluoride in nickel plating bath were mainly investigated in nickel electroplating on magnesium alloy AZ91D. The state of zinc immersion, the composition of zinc film and the role of fluoride in nickel plating bath were explored from the curves of open circuit potential (OCP) and potentiodynamic polarization, the images of scanning electron microscopy (SEM) and the patterns of energy dispersive X-ray (EDX). Results show that the optimum zinc film mixing small amount of Mg(OH)2 and MgF2 is obtained by zinc immersion for 30-90 s. The corrosion potential of magnesium alloy substrate attached zinc film will be increased in nickel plating bath and the quantity of MgF2 sandwiched between magnesium alloy substrate and nickel coating will be reduced, which contributed to produce nickel coating with good performance. Fluoride in nickel plating bath serves as an activator of nickel anodic dissolution and corrosion inhibitor of magnesium alloy substrate. 1.0-1.5 mol dm−3 of F is the optimum concentration range for dissolving nickel anode and protecting magnesium alloy substrate from over-corrosion in nickel plating bath. The nickel coating with good adhesion and high corrosion resistance on magnesium alloy AZ91D is obtained by the developed process of nickel electroplating. This nickel layer can be used as the rendering coating for further plating on magnesium alloys.  相似文献   

5.
Two pre-treatments were studied for AZ31 Mg alloy substrates, consisting of immersion in cerium nitrate and lanthanum nitrate solutions for various immersion times. The surface composition was investigated by X-ray photoelectron spectroscopy and Auger electron spectroscopy that revealed the presence of a surface film containing the rare-earth cation, with a composition which was time dependent in the case of the cerium pre-treatment.The corrosion behaviour of the pre-treated substrates in 0.005 M NaCl solutions was assessed by potentiodynamic polarization, open circuit potential monitoring and the scanning vibrating electrode technique (SVET). The electrochemical results show that the pre-treatments reduced the corrosion activity of the AZ31 Mg alloy substrates in the presence of chloride ions. The corrosion protection efficiency is dependent on the treatment time.  相似文献   

6.
Microarc oxidation coatings on AM60B magnesium alloy were prepared in silicate and phosphate electrolytes. Structure, composition, mechanical property, tribological, and corrosion resistant characteristics of the coatings was studied by scanning electron microscope (SEM), X-ray diffraction (XRD) and microhardness analyses, and by ball-on-disc friction and potentiodynamic corrosion testing. It is found that the coating produced from the silicate electrolyte is compact and uniform and is mainly composed of MgO and forsterite Mg2SiO4 phases, while the one formed in phosphate electrolyte is relatively porous and is mainly composed of MgO phase. The thick coating produced from a silicate electrolyte possesses a high hardness and provides a low wear rate (3.55 × 10−5 mm3/Nm) but a high friction coefficient against Si3N4 ball. A relatively low hardness and friction coefficient while a high wear rate (8.65 × 10−5 mm3/Nm) is recorded during the testing of the thick coating produced from a phosphate electrolyte. Both of these types of coatings provide effective protection for the corrosion resistance compared with the uncoated magnesium alloy. The coating prepared from the silicate electrolyte demonstrates better corrosion behavior due to the compacter microstructure.  相似文献   

7.
采用沉积的方法在镁合金AZ31表面制备植酸转化膜并研究了pH值的影响. 利用极化曲线和电化学阻抗谱方法测定其耐腐蚀性能,用扫描电子显微镜观察转化膜的表面微观结构,用能谱测定转化膜的组成元素. 在理论上通过热力学的方法分析最佳pH值. 植酸转化膜可以提高镁合金AZ31的耐腐蚀性能. 当植酸溶液的pH=5时腐蚀效率达到了89.19%,此时腐蚀电位正移了156 mV,腐蚀电流密度与没有处理的试样相比减小了约一个数量级. 热力学分析表明植酸转化膜的耐腐蚀性能不仅受植酸根离子和镁离子浓度的影响,也与氢气释放的速率有关.  相似文献   

8.
The microstructure, morphology and composition highly determine the corrosion resistance and bioactivity of coating. In traditional cathodic electrodeposition process, because of the unfavorable effects of the polarization of concentration difference and H2 evolution, fluorine-doped hydroxyapatite coating was loose and porous. This coating could not ensure the long-term stability of the Mg alloy implants. In order to improve the corrosion resistance and bioactivity of coating, pulse electrodeposition and H2O2 were introduced into the electrodeposition to deposit fluorine-doped hydroxyapatite coating. As a comparative study, microstructure, corrosion resistance properties and bioactivity of traditional cathodic electrodeposition coating and pulse electrodeposition coating were investigated, respectively. The results revealed that nano fluorine-doped hydroxyapatite coating could be prepared by pulse electrodeposition, and the coating was dense and uniform. The potentiodynamic polarization experiment indicated that the dense and uniform coating could effectively protect Mg alloy substrate from corrosion. Immersion testing was performed in simulated body fluid. It was found that pulse electrodeposition coating could more effectively induce the precipitation of Mg2+, Ca2+ and PO43− in comparison with traditional cathodic electrodeposition coating, because the nano phase had comparatively high specific surface area. Thus magnesium alloy coated with fluorine-doped nano-hydroxyapatite coating may be a promising candidate as biodegradable bone implants, and was worthwhile to further investigate the in vivo degradation behavior.  相似文献   

9.
Coatings with a thickness of 22-32 μm were formed on an AM60B magnesium alloy by plasma electrolytic oxidation (PEO) in electrolytes containing 12.0-24.0 g/l NaAlO2 and other additives. SEM analyses of the coated samples showed that the coatings were compact with relatively low porosity. X-ray diffraction revealed that the coatings consisted of mainly MgAl2O4 and MgO phases. The relative amount of MgAl2O4 in the coating increased with increasing NaAlO2 concentration. The relatively compact and thick coatings provide good corrosion protection for magnesium, as indicated by the results of potentiodynamic polarization tests. In addition, the PEO treatment also significantly improved the wear resistance of the alloy. Pin-on-disk wear tests showed that the PEO treatment reduced the wear volume loss by a factor of 10.  相似文献   

10.
Broad-beam laser cladding of Al-Cu alloy coating on AZ91HP magnesium alloy   总被引:3,自引:0,他引:3  
The resistance to wear and corrosion of AZ91HP Mg alloy was improved by laser cladding Al-Cu alloy. It was found that the clad layer was characterized by AlCu4 and Mg17Al12 grains embedded in a AlMg matrix. The bonding zone exhibited a white-light planar crystal band with thickness of 10-13 μm. The heat-affected zone formed a eutectic structure due to the Mg diffusion. The microhardness and wear resistance of the coating were improved due to the formation of the hard phases AlCu4 and Mg17Al12. Owing to the formation of dense Al2O3 oxide film, the coating exhibited better corrosion resistance in 3.5 wt.% NaCl solution.  相似文献   

11.
Ceramic coatings oxidized for different time periods were prepared to characterize the plasma electrolytic oxidation (PEO) process of AZ91D magnesium alloy. The coatings were analyzed using scanning electron microscopy, X-ray diffraction, X-ray photoelectron spectroscope and potentiodynamic polarization measurement. The results show that the PEO coatings perform different growth behaviors at different PEO stages, and different morphologies are exhibited on α- and β-phase of Mg substrate. The corrosion resistance measurement predicates that within the first 30 min oxidation, coating oxidized for 20 min is the best corrosion resistant.  相似文献   

12.
X-ray photoelectron spectroscopy (XPS) was used in order to investigate the correlation between the surface chemistry and the atmospheric corrosion of AZ31, AZ80 and AZ91D magnesium alloys exposed to 98% relative humidity at 50 °C. Commercially pure magnesium, used as the reference material, revealed MgO, Mg(OH)2 and tracers of magnesium carbonate in the air-formed film. For the AZ80 and AZ91D alloys, the amount of magnesium carbonate formed on the surface reached similar values to those of MgO and Mg(OH)2. A linear relation between the amount of magnesium carbonate formed on the surface and the subsequent corrosion behaviour in the humid environment was found. The AZ80 alloy revealed the highest amount of magnesium carbonate in the air-formed film and the highest atmospheric corrosion resistance, even higher than the AZ91D alloy, indicating that aluminium distribution in the alloy microstructure influenced the amount of magnesium carbonate formed.  相似文献   

13.
In this paper, ceramic coatings were prepared on biomedical NiTi alloys by micro-arc oxidation (MAO) in constant voltage mode. The current density-time response was recorded during the MAO process. The microstructure, element distribution and phase composition of the coatings prepared at different MAO treatment times were investigated by scanning electron microscopy (SEM), energy dispersive X-ray spectrometer (EDS), thin-film X-ray diffraction (TF-XRD) and X-ray photoelectron spectroscopy (XPS). The corrosion behavior of the coatings in 0.9% NaCl solution was evaluated by the potentiodynamic polarization test. It is found that the coatings become more compact with increasing the MAO treatment time, and the growth rate of coating decreases. The results of TF-XRD, EDS and XPS indicate that the coatings are composed of a large amount of γ-Al2O3 and a little α-Al2O3, TiO2 and Ni2O3. The Ni content of the coatings is about 3 at.%, which is greatly lower than that of NiTi substrate. The bonding strength of coating-substrate is higher than 40 MPa for all the samples in this study. The corrosion resistance of the coatings is about two orders of magnitude higher than that of the uncoated NiTi alloy.  相似文献   

14.
Chemical nature of phytic acid conversion coating on AZ61 magnesium alloy   总被引:6,自引:0,他引:6  
Phytic acid (PA) conversion coating on AZ61 magnesium alloy was prepared by the method of deposition. The influences of pH, time and PA concentration on the formation process, microstructure and properties of the conversion coating were investigated. Scanning electron microscopy (SEM) was used to observe the microstructure. The chemical nature of conversion coating was investigated by energy dispersive X-ray spectroscopy (EDS) and Fourier transform infrared spectroscopy (FTIR) techniques. The corrosion resistance was examined by means of potentiodynamic polarization method. The adhesive ability was tested by score experiments. The results showed that the growth and microstructure of the conversion coatings were all obviously affected by pH, time and PA concentration. In 0.5 mg/ml PA solution with a pH of 5, an optimization conversion coating formed after 20 min immersion time by deposition of PA on AZ61 magnesium alloy surface through chelating with Al3+. It made the corrosion potential Ecorr of sample shifted positively about 171 mV than that of the untreated sample, and the adhesive ability reached to Grade 1 (in accordance with GB/T 9286).  相似文献   

15.
Friction stir welding is a promising solid state joining process for high strength aluminum alloys. Though friction stir welding eliminates the problems of fusion welding as it is performed below melting temperature (Tm), it creates severe plastic deformation. Friction stir welds of some aluminum alloys exhibit relatively poor corrosion resistance. This research enhanced the corrosion properties of such welds through diode laser surface melting.A friction stir weld of aluminum alloy 2024 T351 was laser melted using a 1 kW diode laser. The melt-depth and microstructure were investigated using optical and scanning electron microscopy. The melt zone exhibited epitaxially grown columnar grains. At the interface between the melted and the un-melted zone, a thick planar boundary was observed. Energy dispersive spectroscopy analyzed the redistribution of elemental composition. The corrosion properties of the laser melted and native welds were studied in aqueous 0.5 M sodium chloride solution using open circuit potential and cyclic potentiodynamic polarization. The results show noticeable increase in the pit nucleation resistance (390 mV) after the laser surface treatment. The repassivation potential was nobler to the corrosion potential after the laser treatment, which confirmed that the resistance to pit growth was improved.  相似文献   

16.
Phytic acid (PA) conversion coating on WE43 magnesium alloy was prepared by the method of immersion. The influences of phytic acid solution with different pH on the microstructure, properties of the conversion coating and the corrosion resistance were investigated by SEM, FTIR and potentiodynamic polarization method. Furthermore, the biocompatibility of different pH phytic acid solution modified WE43 magnesium alloys was evaluated by MTT and hemolysis test. The results show that PA can enhance the corrosion resistance of WE43 magnesium especially when the pH value of modified solution is 5 and the cytotoxicity of the PA coated WE43 magnesium alloy is much better than that of the bare WE43 magnesium alloy. Moreover, all the hemolysis rates of the PA coated WE43 Mg alloy were lower than 5%, indicating that the modified Mg alloy met the hemolysis standard of biomaterials. Therefore, PA coating is a good candidate to improve the biocompatibility of WE43 magnesium alloy.  相似文献   

17.
Titanium oxide ceramic coatings were prepared by micro-arc oxidation (MAO) in galvanostatic regime on biomedical NiTi alloy in H3PO4 electrolyte using DC power supply. The surface of the coating exhibited a typical MAO porous and rough structure. The XPS analysis indicated that the coatings were mainly consisted of O, Ti, P, and a little amount of Ni, and the concentration of Ni was greatly reduced compared to that of the NiTi substrate. The TF-XRD analysis revealed that MAO coating was composed of amorphous titanium oxide. The coatings were tightly adhesive to the substrates with the bonding strength more than 45 MPa, which was suitable for medical applications. The curves of potentiodynamic porlarization indicated that the corrosion resistance of NiTi alloy was significantly improved due to titanium oxide formation on NiTi alloy by MAO.  相似文献   

18.
Magnesium-based biomaterials have been proposed as potential candidates for biodegradable implant materials, such as bone screws, bone plates, intraluminal stents and so on. However, the poor corrosion resistance inhibits their applications in surgery. They collapse before the injured tissues are healed. In this paper, Mg(OH)2 nonstructural film was synthesized on the substrate of AZ31 magnesium alloy by hydrothermal method with NaOH solution as mineralizer to reduce the corrosion rate of magnesium-based materials. The obtained films were characterized by XRD, SEM, and XPS. The results showed that a Mg(OH)2 film with nanostructure surface can be synthesized by hydrothermal method. It was observed that the thickness of film increased with the holding time. Corrosion rates of the films were studied by immersing the samples in Hank's solution (37 °C). Surface deposits of samples with films soaked in Hank's solution for 31 days were investigated by XRD, SEM, EDS, XPS, and FTIR. It verified that the corrosion rate of the magnesium alloy with grown film was slowed down in the Hank's solution and the behavior of corrosion was inhibited effectively. Amorphous calcium apatite precursor was observed to deposit on the surface of the film during corrosion experiments in Hank's solution. And the tape test revealed a strong adhesion between the film and the substrate.  相似文献   

19.
Electroless deposition of Ni-W-P coating on AZ91D magnesium alloy   总被引:1,自引:0,他引:1  
Ternary Ni-W-P alloy coating was deposited directly on AZ91D magnesium alloy by using an alkaline-citrate-based baths. Nickel sulfate and sodium tungstate were used as metal ion sources, respectively, and sodium hypophosphite was used as a reducing agent. The pH value of the electroless bath was tailored for magnesium alloy. The coating was characterized for its structure, morphology, microhardness and the corrosion properties. SEM observation showed the presence of dense and coarse nodules in the ternary coating. EDS analysis showed that the content of tungsten in the Ni-W-P alloy was 4.5 wt.%. Both the electrochemical analysis and the immersion test in 10% HCl solution revealed that the ternary Ni-W-P coating exhibited good corrosion resistance properties in protecting the AZ91D magnesium alloy.  相似文献   

20.
Rough and porous Al2O3 coatings containing Ca and P were prepared on Ti–50.8 at.% Ni alloy by micro-arc oxidation (MAO) technique. The microstructure, elemental and phase composition of the coatings were investigated by scanning electron microscopy (SEM), energy dispersive X-ray spectrometer (EDS) and thin-film X-ray diffraction (TF-XRD). The thickness of the coatings was measured by eddy current coating thickness gauge. The corrosion resistance and the nickel release of the coated and uncoated samples were examined by potentiodynamic polarization tests and immersion tests in Hank’s solution, respectively. The results show that the coatings are mainly composed of γ-Al2O3 crystal phase. The Ni content of the coatings is about 3.5 at.%, which is greatly lower than that of NiTi substrate. With increasing treatment time, both thickness and roughness of the coatings increase. The corrosion resistance of the coated samples is about two orders of magnitude higher than that of the uncoated NiTi alloy. The concentration of Ni released from coated NiTi samples is much lower than that of uncoated NiTi sample. It can be reduced in the factor of one-seventh compared with the uncoated NiTi sample after 3 weeks immersion in Hank’s solution.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号