首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 497 毫秒
1.
Graphene is a novel and interesting carbon material that could be used for the separation and purification of some chemical compounds. In this investigation, graphene was used as a novel fiber‐coating material for the solid‐phase microextraction (SPME) of four triazine herbicides (atrazine, prometon, ametryn and prometryn) in water samples. The main parameters that affect the extraction and desorption efficiencies, such as the extraction time, stirring rate, salt addition, desorption solvent and desorption time, were investigated and optimized. The optimized SPME by graphene‐coated fiber coupled with high‐performance liquid chromatography‐diode array detection (HPLC‐DAD) was successfully applied for the determination of the four triazine herbicides in water samples. The linearity of the method was in the range from 0.5 to 200 ng/mL, with the correlation coefficients (r) ranging from 0.9989 to 0.9998. The limits of detection of the method were 0.05‐0.2 ng/mL. The relative standard deviations varied from 3.5 to 4.9% (n=5). The recoveries of the triazine herbicides from water samples at spiking levels of 20.0 and 50.0 ng/mL were in the range between 86.0 and 94.6%. Compared with two commercial fibers (CW/TPR, 50 μm; PDMS/DVB, 60 μm), the graphene‐coated fiber showed higher extraction efficiency.  相似文献   

2.
The solid‐phase microextraction (SPME) technique using a 100 μm film polydimethylsiloxane (PDMS) coated fiber has been examined with the aim to determine dichlorobenzene in aqueous samples. The feasibility of SPME‐GC‐ECD analysis has been evaluated. Absorption time of 30 min was selected and 1 min was long enough for complete desorption of the analytes in the injection port of the gas chromatograph. Linear ranges from 0.03 to 5 μg/L and method detection limits between 7 and 9 ng/L for dichlorobenzenes were obtained. The relative standard deviations were less than 12% for a spiking level of 3 μg/L. The proposed method was applied to determine dichlorobenzenes in spiked deionized water, ground water, and in industrial effluent samples.  相似文献   

3.
The volatile composition of different apple varieties of Malus domestica Borkh. species from different geographic regions at Madeira Islands, namely Ponta do Pargo (PP), Porto Santo (PS), and Santo da Serra (SS) was established by headspace solid‐phase microextraction (HS‐SPME) procedure followed by GC‐MS (GC‐qMS) analysis. Significant parameters affecting sorption process such as fiber coating, extraction temperature, extraction time, sample amount, dilution factor, ionic strength, and desorption time, were optimized and discussed. The SPME fiber coated with 50/30 μm divinylbenzene/carboxen/PDMS (DVB/CAR/PDMS) afforded highest extraction efficiency of volatile compounds, providing the best sensitivity for the target volatiles, particularly when the samples were extracted at 50°C for 30 min with constant magnetic stirring. A qualitative and semi‐quantitative analysis between the investigated apple species has been established. It was possible to identify about 100 of volatile compounds among pulp (46, 45, and 39), peel (64, 60, and 64), and entire fruit (65, 43, and 50) in PP, PS, and SS apples, respectively. Ethyl esters, terpenes, and higher alcohols were found to be the most representative volatiles. α‐Farnesene, hexan‐1‐ol and hexyl 2‐methylbutyrate were the compounds found in the volatile profile of studied apples with the largest GC area, representing, on average, 24.71, 14.06, and 10.80% of the total volatile fraction from PP, PS, and SS apples. In PP entire apple, the most abundant compounds identified were α‐farnesene (30.49%), the unknown compound m/z (69, 101, 157) (21.82%) and hexyl acetate (6.57%). Regarding PS entire apple the major compounds were α‐farnesene (16.87%), estragole (15.43%), hexan‐1‐ol (10.94), and E‐2‐hexenal (10.67). α‐Farnesene (30.3%), hexan‐1‐ol (18.90%), 2‐methylbutanoic acid (4.7%), and pentan‐1‐ol (4.6%) were also found as SS entire apple volatiles present in a higher relative content. Principal component analysis (PCA) of the results clustered the apples into three groups according to geographic origin. Linear discriminant analysis (LDA) was performed in order to detect the volatile compounds able to differentiate the three kinds of apples investigated. The most important contributions to the differentiation of the PP, PS, and SS apples were ethyl hexanoate, hexyl 2‐methylbutyrate, E,E‐2,4‐heptadienal, p‐ethyl styrene, and E‐2‐hexenal.  相似文献   

4.
A method for the trace determination of cadmium ions in water, human urine and human blood serum samples using ultrasonic‐assisted dispersive micro‐solid‐phase extraction (UA‐D‐μSPE) was developed. Silica‐coated magnetic nanoparticles were coated with polythiophene, and the resulting sorbent was characterized using thermogravimetry, differential thermal analysis, scanning electron microscopy, Fourier transform infrared spectrometry and X‐ray diffraction. Following UA‐D‐μSPE, cadmium ions were quantified using graphite furnace atomic absorption spectrometry. A Box–Behnken design was used for optimization of important sorption and desorption parameters in UA‐D‐μSPE: in the sorption step, pH of solution, sorption amount and sonication time for sorption; in the desorption step, concentration of eluent, volume of eluent and sonication time. The optimum conditions for the method were: pH of solution, 7.5; sonication time for sorption, 3 min; sorption amount, 35 mg; type and concentration of eluent, HCl and 1.1 mol l?1; volume of eluent, 360 μl; sonication time for desorption, 110 s. Under the optimized conditions the limit of detection and relative standard deviation for the detection of cadmium ions by UA‐D‐μSPE were found to be 0.8 ng l?1 and <6%, respectively.  相似文献   

5.
An application of the direct coupling of solid-phase microextraction (SPME) with mass spectrometry (MS), a technique known as fiber introduction mass spectrometry (FIMS), is described to determine organochlorine (OCP) and organophosphorus (OPP) pesticides in herbal infusions of Passiflora L. A new fiber coated with a composite of poly(dimethylsiloxane) and poly(vinyl alcohol) (PDMS/PVA) was used. Sensitive, selective, simple and simultaneous quantification of several OCP and OPP was achieved by monitoring diagnostic fragment ions of m/z 266 (chlorothalonil), m/z 195 (alpha-endosulfan), m/z 278 (fenthion), m/z 263 (methyl parathion) and m/z 173 (malathion). Simple headspace SPME extraction (25 min) and fast FIMS detection (less than 40 s) of OCP and OPP from a highly complex herbal matrix provided good linearity with correlation coefficients of 0.991-0.999 for concentrations ranging from 10 to 140 ng ml(-1) of each compound. Good accuracy (80 to 110%), precision (0.6-14.9%) and low limits of detection (0.3-3.9 ng ml(-1)) were also obtained. Even after 400 desorption cycles inside the ionization source of the mass spectrometer, no visible degradation of the novel PDMS/PVA fiber was detected, confirming its suitability for FIMS. Fast (ca 20 s) pesticide desorption occurs for the PDMS/PVA fiber owing to the small thickness of the film and its reduced water sorption.  相似文献   

6.
An application of the direct coupling of solid-phase microextraction (SPME) with mass spectrometry (MS), a technique known as fiber introduction mass spectrometry (FIMS), is described to determine organochlorine (OCP) and organophosphorus (OPP) pesticides in herbal infusions of Passiflora L. A new fiber coated with a composite of poly(dimethylsiloxane) and poly(vinyl alcohol) (PDMS/PVA) was used. Sensitive, selective, simple and simultaneous quantification of several OCP and OPP was achieved by monitoring diagnostic fragment ions of m/z 266 (chlorothalonil), m/z 195 (alpha-endosulfan), m/z 278 (fenthion), m/z 263 (methyl parathion) and m/z 173 (malathion). Simple headspace SPME extraction (25 min) and fast FIMS detection (less than 40 s) of OCP and OPP from a highly complex herbal matrix provided good linearity with correlation coefficients of 0.991-0.999 for concentrations ranging from 10 to 140 ng ml(-1) of each compound. Good accuracy (80 to 110%), precision (0.6-14.9%) and low limits of detection (0.3-3.9 ng ml(-1)) were also obtained. Even after 400 desorption cycles inside the ionization source of the mass spectrometer, no visible degradation of the novel PDMS/PVA fiber was detected, confirming its suitability for FIMS. Fast (ca 20 s) pesticide desorption occurs for the PDMS/PVA fiber owing to the small thickness of the film and its reduced water sorption.  相似文献   

7.
The dimerization of alkanethiol mixtures (hexanethiol, octanethiol, and dodecanethiol) to form self‐assembled monolayers (SAMs) from headspace on nanoporous gold surfaces was studied for the first time using gas chromatography (GC/MS) and time‐of‐flight secondary ion mass spectrometry (TOF‐SIMS). The nanoporous gold surfaces were obtained by an acidic etching of a 585‐gold alloy. Field emission scanning electron microscopy (FE‐SEM) was utilized to study the change of the surface geometry and porosity of the gold surfaces before and after etching. Alkanethiols were deposited from the vapor phase above the thiol solutions (headspace) on nanoporous gold plates and nanoporous gold solid‐phase vmicroextraction (SPME) fibers. The nanoporous gold substrates were analyzed by TOF‐SIMS and GC/MS, respectively. The TOF‐SIMS spectra exhibited various gold–sulfur ion clusters and specific peaks related to the adsorption of thiols such as deprotonated monomers, thiolate–Au, dimers (e.g., dialkyl sulfides–Au and dialkyl disulfides–Au). The GC/MS analysis of headspace extractions of alkanethiol mixtures by nanoporous gold SPME fibers showed a high extraction efficiency of alkanethiol, dialkyl sulfide, and dialkyl disulfide when compared with the commercial SPME fibers (DVB‐CAR‐PDMS and CAR‐PDMS). Different GC/MS optimization factors were studied including the extraction time and desorption temperature.  相似文献   

8.
Liquid chromatography‐tandem mass spectrometry (LC‐MS/MS) method has proved to powerful research tool due to its sensitivity, high selectivity, and high throughput efficiency..Sirolimus was extracted from plasma by two‐step extraction procedure using chloroform as extracting solvent. Signal intensity was high using ESI+ source provided for the quantitation of samples. Chromatographic separation was performed on phenomenax C‐18 column (250 × 4.60 mm 5microns).Mobile phase contains acetonitrile, water (80; 20 v/v) + 0.1% acetic acid, flow rate 1 mL/min.The retention time of Sirolimus 8.4 min, the total run time10 min. Linearity correlation coefficients (r2) curve was 0.997183.calibraction range 10–1000 ng/mL. The UV detection of Sirolimus was at 278(277.78) nm. Sirolimus coated drug eluting stents, MRM (Multiple reaction monitoring) transition of Sirolimus m/z 936.83–208.84 was selected to obtain maximum sensitivity. LC/MS/MS results exhibited consistency in drug content on the stent surface. In‐vitro release kinetic indicated the release of Sirolimus in 41 days from the date of implanted. Drug release was found at the first day, burst release was observed at 7th day of implantation. This study involved pharmacological coating of stents, based on the notion that sustained systemic local delivery of anti‐proliferative agents. LC‐MS/MS method has been successfully used in the pharmacokinetic analysis of Sirolimus coated drug eluting stents. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

9.
A method for the determination of polycyclic aromatic hydrocarbons (PAHs) in soil samples using ultrasonic‐assisted extraction with internal surrogates combined with solid‐phase microextraction and GC‐MS has been developed. Five kinds of commercial solid‐phase microextraction fibers, 100 μm PDMS, 30 μm PDMS, 65 μm PDMS/DVB, 50 μm DVB/CAR/PDMS and 85 μm PA, were compared to choose the optimal SPME fiber for extraction of PAHs. One hundred micrometers of PDMS fiber was found to be more suitable for the determination of PAHs due to its wider linear range, better repeatability, lower detection and more satisfactory efficacy than the other fibers. Under the recommended conditions, 100 μm PDMS fiber could provide low nanogram level detection limits with correlation coefficient greater than 0.98. The method was also applied to determine PAHs in a spiked soil sample, obtaining recoveries higher than 79.3%. A field study with naturally contaminated samples from local contaminated sites was carried out. The proposed method was found to be a reliable, inexpensive and simple preparation method for quantitative determination of 16 PAHs in soil samples.  相似文献   

10.
A headspace solid‐phase microextraction (HS‐SPME) method coupled to GC‐MS was developed in order to determine trace levels of tetramethyltin (TeMT) and inorganic tin (iSn) after ethylation to tetraethyltin (TeET) in various matrices. The derivatization of iSn and the extraction of both TeMT and iSn as TeET were performed in one step. Sodium tetraethylborate (NaBEt4) was used as derivatization agent and the volatile derivatives were absorbed on a PDMS‐coated fused silica fiber. The conditions for the HS‐SPME procedure were optimized in order to gain in repeatability and sensitivity. Several critical parameters of GC‐MS were also studied. The detection of TeMT and iSn as TeET peaks was performed by the SIM mode. The precision of the proposed method is satisfactory providing RSD values below 10% for both tin species and good linearity up to 10 μg/L. The developed method was successfully applied to the determination of tin species in several samples like canned fish, fish tissues, aquatic plants, canned mineral water and sea water. The proposed HS‐SPME‐GC‐MS method was proved suitable to monitor the concentration levels of toxic tin compounds in environmental and biological samples.  相似文献   

11.
A novel method utilizing ambient thermal desorption ionization with a direct analysis in real‐time source integrated with mass spectrometry (DART‐MS) was established and applied to the rapid analysis of 3‐hydroxy‐3‐methylglutaric (3‐HMG) acid in the neonatal urine. Instrument parameter settings were optimized to obtain high sensitive and accurate determination of 3‐HMG acid. The use of helium gas heated to temperature of 400°C was observed to permit deprotonation, 3‐HMG acid producing an abundant (M‐H)? (m/z 161) in the negative ion mode. The calibration curve was determined to be linear over the range of 0.05‐5 mg/L, with the correlation coefficient r = 0.9988 and the relative standard deviations (n = 6) in the range of 1.5‐11.8%. The limit of detection was 0.002 mg/L, and the limit of quantitation was 0.007 mg/L. The recoveries ranged from 88.0% to 123.1%. Four urine samples from patients and four simulated urine samples were investigated. The results of DART‐MS were in agreement with the values determined using established methods at the hospitals. The proposed method demonstrated significant potential in the application of the high‐throughput screening in newborn screening.  相似文献   

12.
A method for the extraction and determination of methylmercury (MeHg) in solid matrices is presented. Combining the advantages of two extraction techniques—subcritical water extraction (subWE) and solid‐phase microextraction (SPME)—selective separation of MeHg from soils is possible. The procedure is based on extraction with subcritical water without using organic solvents, followed by in situ aqueous‐phase derivatization with sodium tetraethylborate and headspace SPME with a silica fiber coated with poly(dimethylsiloxane). The optimization of the extraction parameters is described. The identification and quantification of the extracted alkylmercury compounds from spiked soil samples is performed by GC–MS after thermal desorption. Copyright © 2000 John Wiley & Sons, Ltd.  相似文献   

13.
Fiber introduction mass spectrometry (FIMS)-a direct coupling of SPME and MS-using selective ion monitoring (SIM) was used to detect and quantify dimethylphthalate (DMP), diethylphthalate (DEP) and dipropylphthalate (DPP) in mineral water. In FIMS, a chromatographic silicone septum is the only barrier between ambient and the high-vacuum mass spectrometer, permitting direct introduction of the SPME fiber into the ionization region of the equipment. After their thermal desorption and ionization and dissociation, the extracted phthalates are detected and quantitated by MS. Three types of SPME fibers were screened for best analyte sorption/desorption behaviors: 100 microm polydimethylsiloxane (PDMS), 65 microm polydimethylsiloxane/divinylbenzene (PDMS/DVB) and 65 microm Carbowax/divinylbenzene (CW/DVB). The PDMS/DVB and CW/DVB fibers were then evaluated for precision, and quantitative figures of merit were assessed for extractions using the PDMS/DVB fiber, which displayed the best overall performance. FIMS with the PDMS/DVB fiber allows simple extraction and MS detection and quantitation of DMP in water with good linearity and precision, and at concentrations as low as 3.6 microg L(-1). The LD and LQ of FIMS are below the maximum phthalate concentration allowed by the USEPA for drinking water (6 microg L(-1)).  相似文献   

14.
9‐Dehydro‐17‐hydro‐andrographolide (DHA) and sodium 9‐dehydro‐17‐hydro‐andrographolide‐19‐yl sulfate (DHAS) are active ingredients of xiyanping injection in clinical use. A simple, rapid and sensitive UHPLC‐ESI‐MS/MS method was developed for the determination of DHA and DHAS in rat plasma, and the pharmacokinetics of DHA and DHAS after intravenous administration of xiyanping injection was investigated. The plasma samples were treated with methanol to precipitate out protein, and the separation of DHA and DHAS was achieved on a Waters BEH C18 column with a mobile phase consisting of acetonitrile and 10 mmol/L ammonium acetate solution at a flow rate of 0.4 mL/min. DHA, DHAS and the internal standard (internal standard, IS) diethylstilbestrol were detected at negative ion mode. The precursor‐product ion pairs used in multiple reaction monitoring mode were: m/z 349.1 → 286.9 (DHA), m/z 428.9 → 96.0 (DHAS) and m/z 267.1 → 236.9 (IS). Calibration curves offered satisfactory linearity within the test range, and all correlation coefficients were >0.995. The lower limit of detection of DHA and DHAS in plasma samples were determined to be 0.1 ng/mL. The lower limit of quantitation was 0.5 ng/mL for DHA and DHAS. All the recoveries of the quality control samples were in the range of 86.0–102.4%. The ratios of matrix effect were between 89.2 and 105.1%. The method was fully validated and successfully applied to the pharmacokinetic study of DHA and DHAS in rats. The study showed that both DHA and DHAS were distributed and eliminated rapidly in rats. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

15.
Stir Bar Sorptive Extraction (SBSE), a recently introduced solventless extraction technique, was applied for the enrichment of benzoic acid in lemon flavored beverages. The stir bar is covered with 50 mg polydimethylsiloxane (PDMS) and the extraction mechanism is similar to that of solid phase micro extraction (SPME) but the enrichment factor is ca. 100 times higher. SBSE is followed by thermal desorption (TD)‐capillary gas chromatography (CGC)‐mass spectroscopy (MS). Calibration graphs for benzoic acid were linear from 1 to 1000 ppm for water and diluted soft drinks and the repeatability (n = 6) was less than 5% RSD.  相似文献   

16.
Trans-2-nonenal is an aldehyde contributing to an unpleasant off-flavor and odor of rancid butter in stored beer. The automated solid-phase microextraction technique (SPME) coupled with gas chromatography (GC) and solid-phase dynamic extraction (SPDE) coupled with gas chromatography were optimized and introduced to determine trans-2-nonenal in barley, malt and beer. Five types of SPME fibers coated with different stationary phases (100 μm PDMS, 65 μm PDMS/DVB, 85 μm CAR/PDMS, 50/30 μm DVB/CAR/PDMS, 85 μm PA) and two needles (PDMS, PDMS/AC) were compared and tested for their efficiencies in the headspace (HS) SPME and SPDE determination of trans-2-nonenal in barley, malt and beer. The highest extraction efficiency of HS-SPME was achieved with the PDMS/DVB fiber, and addition of 1.5 g of NaCl, extraction time was 20 min at 60 °C. The highest extraction efficiency of HS-SPDE was obtained with the PDMS needle, 15 extraction strokes at 60 °C and addition of 1.5 g of NaCl. Trans-2-nonenal was identified with the method of HS-SPME coupled gas chromatography-mass spectrometry (GC–MS); the samples were analyzed using the HS-SPME-GC-coupled gas chromatography-flame ionization detector (GC-FID) technique.  相似文献   

17.
In this work, a graphene composite was coated onto etched stainless‐steel wire through a sol–gel technique and it was used as a solid‐phase microextraction (SPME) fiber. The prepared fiber was characterized by SEM, which revealed that the fiber had a highly porous structure. The application of the fiber was evaluated through the headspace SPME of five halogenated aromatic hydrocarbons (chlorobenzene, bromobenzene, 1,3‐dichlorobenzene, 1,2‐dichlorobenzene, and 1,2,4‐trichlorobenzene) in water samples followed by GC with flame ionization detection. The main factors influencing the extraction efficiency, including headspace volume, extraction time, extraction temperature, stirring rate, ionic strength of sample solution, and desorption conditions, were studied and optimized. Under the optimum conditions, the linearity of the method ranged from 2.5 to 800.0 μg/L for 1,2,4‐trichlorobenzene and from 2.5 to 500.0 μg/L for chlorobenzene, bromobenzene, 1,3‐dichlorobenzene, and 1,2‐dichlorobenzene, with the correlation coefficients (r) ranging from 0.9962 to 0.9980, respectively. The LODs (S/N = 3) of the method for the analytes were in the range between 0.5 and 1.0 μg/L. The recoveries of the method for the analytes obtained for the spiked water samples at 50.0 and 250.0 μg/L were from 76.0 to 104.0%.  相似文献   

18.
A highly porous fiber coated with polythiophene/hexagonally ordered silica nanocomposite was prepared for solid‐phase microextraction (SPME). The prepared nanomaterial was immobilized onto a stainless‐steel wire for the fabrication of the SPME fiber. Polythiophene/hexagonally ordered silica nanocomposite fibers were used for the extraction of some polycyclic aromatic hydrocarbons from water samples. The extracted analytes were transferred to the injection port of a gas chromatograph using a laboratory‐designed SPME device. The results obtained prove the ability of the polythiophene/hexagonally ordered silica material as a new fiber for the sampling of organic compounds from water samples. This behavior is due most probably to the increased surface area of the polythiophene/hexagonally ordered silica nanocomposite. A one‐at‐a‐time optimization strategy was applied for optimizing the important extraction parameters such as extraction temperature, extraction time, ionic strength, stirring rate, and desorption temperature and time. Under the optimum conditions, the LOD of the proposed method is 0.1–3 pg/mL for analysis of polycyclic aromatic hydrocarbons from aqueous samples, and the calibration graphs were linear in a concentration range of 0.001–20 ng/mL (R2 > 0.990) for most of the polycyclic aromatic hydrocarbons. The single fiber repeatability and fiber‐to‐fiber reproducibility were less than 8.6 and 19.1% (n = 5), respectively.  相似文献   

19.
Volatile organic compounds (VOCs) emitted from in vitro cultures may reveal information on species and metabolism. Owing to low nmol L−1 concentration ranges, pre‐concentration techniques are required for gas chromatography–mass spectrometry (GC–MS) based analyses. This study was intended to compare the efficiency of established micro‐extraction techniques – solid‐phase micro‐extraction (SPME) and needle‐trap micro‐extraction (NTME) – for the analysis of complex VOC patterns. For SPME, a 75 μm Carboxen®/polydimethylsiloxane fiber was used. The NTME needle was packed with divinylbenzene, Carbopack X and Carboxen 1000. The headspace was sampled bi‐directionally. Seventy‐two VOCs were calibrated by reference standard mixtures in the range of 0.041–62.24 nmol L−1 by means of GC–MS. Both pre‐concentration methods were applied to profile VOCs from cultures of Mycobacterium avium ssp. paratuberculosis. Limits of detection ranged from 0.004 to 3.93 nmol L−1 (median = 0.030 nmol L−1) for NTME and from 0.001 to 5.684 nmol L−1 (median = 0.043 nmol L−1) for SPME. NTME showed advantages in assessing polar compounds such as alcohols. SPME showed advantages in reproducibility but disadvantages in sensitivity for N‐containing compounds. Micro‐extraction techniques such as SPME and NTME are well suited for trace VOC profiling over cultures if the limitations of each technique is taken into account.  相似文献   

20.
The preparation and applicability of solid phase microextraction (SPME) fibers coated with a sol-gel organically modified silica based on 3-aminopropyltrimethoxysilane and polydimethylsiloxane (APTMS/PDMS) are described here. Micrographs of the coated fibers revealed a rugous surface; the thickness of the coating was estimated to be less than 30 microm. The APTMS/PDMS fibers were tested with synthetic samples and compared to commercial fibers for headspace SPME analysis of beer. Extraction and desorption using the APTMS/PDMS fibers were faster, which is typical for sol-gel SPME fibers. For polar and semi-polar compounds on beer headspace, the extraction efficiencies of the APTMS/PDMS fiber were superior to those of conventional fibers. The APTMS/PDMS fiber was found to be capable of extracting a broad range of analytes, including highly polar acidic species such as organic acids.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号