首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
W Hu  K Hasebe  A Iles  K Tanaka 《Analytical sciences》2001,17(12):1401-1404
A unified ion chromatographic (IC) system was developed for the determination of acidity or alkalinity. Separation column used was a reversed-phase ODS packed column, which had been modified by saturating it with lithium dodecylsulfate. A slightly acidified LiCl (50 mM LiCl and 0.05 mM H2SO4) aqueous solution was used as the eluent. By conditioning the separation column in this way, both H+ and Li+ ions became bound to the stationary phase. Dodecylsulfate groups with Li+ counterions acted as cation-exchange sites for the separation of hydrogen ions (free acidity determination). The remaining dodecylsulfate groups, with H+ counterions acted as a titrant, which reacted with basic species (total alkalinity determination). The acidity or alkalinity of each sample was measured according to the change in conductance from the eluent baseline level. A positive peak was observed from those samples with a free acidity greater than their total alkalinity, due to the separation/elution of free H+ ions. A negative peak was observed from those samples with a free acidity less than their total alkalinity. This was due to an equivalent amount of eluent H+ ions being re-supplied to the stationary phase while the "solid titrant" consumed by the acid-base reaction was regenerated. The retention time for the peak corresponding to the acidity or alkalinity was governed by the retention time for H+ ions in this IC system. Samples with a free acidity greater than 2.25 microM (tested by determination of H+ ions in pure water in equilibrium with atmospheric CO2) could be analyzed by this method. A very similar detection level was obtained for alkalinity (tested by analyzing standard aqueous NaHCO3 solutions). Aqueous solutions of some strong-acid/strong-base inorganic salts were found to be slightly alkaline. This was measured as a percentage, relative to an NaHCO3 solution at the same concentration. Solutions of NaClO4, Na2SO4, NaI, NaNO3, and NaCl, gave comparative alkalinity values of 8.75%, 1.83%, 0.42%, 0.35%, and 0.33%, respectively.  相似文献   

2.
Hu W  Haddad PR  Hasebe K  Tanaka K 《The Analyst》2001,126(5):555-558
An ion chromatographic (IC) method based on the use of titrant (strong acid) as the stationary phase was developed for simultaneous determination of total alkalinity (TA) and monovalent cations. The titrant used in this study was obtained by initially loading lithium dodecylsulfate (Li-DS) onto a reversed-phase material and then conditioning the column with a slightly acidified aqueous LiCl solution (a mixture of 50.0 mM LiCl and 0.1 mM H2SO4). When a small amount of a basic sample was injected onto a column prepared in this way, the basic species (Bn-) reacted predominantly with H+ on the stationary phase and the reaction with the eluent phase was negligible due to the very low concentration of eluent H+ (in the eluent, a molar ratio of [Li+]/[H+] = 250:1 applied). The stationary phase H+ consumed in the acid-base reaction was then re-supplied by H+ from the eluent. By monitoring the conductance of the eluent using conductivity, an induced peak resulting from the basic species was observed. Calibration graphs of peak areas vs. molar concentration of the basic species for OH-, HCO3- and H2PO4- were found to be identical. CO3(2-), HPO4(2-), and B4O7(2-) also gave identical calibration curves but their slope values were twice those for HCO3-. The detection limit for HCO3- was less than 3.2 microM and the calibration curve was linear up to 12.3 mM (injection volume, 100 microL). Seawater was directly analyzed and its total alkalinity was found to be 2.87 mM (RSD 0.53%, n = 5), which was in good agreement with the result of 2.88 mM (RSD 3.2%, n = 5) obtained using auto-potentiometric titration. Na+ and K+ were determined simultaneously and the concentrations were 481.6 and 10.6 mM, respectively.  相似文献   

3.
A further investigation of a chromatographic system allowing determination of hydrogen ions is reported. For this purpose an octadecylsilica column dynamically modified with sodium dodecylsulfate (SDS) or lithium dodecylsulfate (LDS) was used as stationary phase and a slightly acidified electrolyte (usually KCl)-SDS solution was used as the eluent. The concentration of SDS, KCl and the acidity of the eluent affected the structure of aggregates formed by the molecules of dodecylsulfate at the surface of the stationary phase. These aggregates of dodecylsulfate were found to be responsible for the appearance of a chromatographic peak attributed to the presence of H3O+ ions in a sample. Other cations in the sample could be separated in the same manner, permitting the simultaneous separation of monovalent cations from H3O+. The detection limit for H3O+ ions was 2.25 x 10(-6) M using an eluent comprising 0.3 mM LDS, 50.0 mM KCl and 0.10 mM H2SO4. The proposed method is shown to be applicable for the determination of free H3O+ ions in aqueous solutions of strong acids.  相似文献   

4.
A monolithic ODS-silica gel column modified by saturating it with lithium dodecylsulfate (Li-DS) was used to demonstrate the high-speed separation of H+ from other mono- and divalent cations, such as Na+, NH4+, K+, Mg2+ and Ca2+ using ion chromatography (IC). Using a 5 mM EDTA-2K solution containing 0.10 mM Li-DS (pH 4.80) as eluent, H+ was eluted with a sharp and symmetrical peak within 1.0 min before other cations at a flow-rate of 1.5 ml min(-1). The rapid elution of H+ and its conductimetric detection could be attributed to the presence of EDTA (HY2-), which can convert H+ ions as anions. i.e. H(+) + H2Y(2-) --> H3Y(-). The acidity of rainwater and deionized water samples was determined using this IC system with satisfactory results.  相似文献   

5.
Poly(aspartic acid)-silica (PolyCAT A), originally designed for the cation-exchange chromatography of proteins, is proposed for the simultaneous ion chromatographic separation of inorganic anions and cations. This is possible owing to the zwitterion-exchange properties of this stationary phase, which are attributed to the presence of both protonated aminopropyl and dissociated carboxylic groups in poly(aspartic acid) attached to the silica. The retention of alkali metal (Li+, Na+, K+), alkaline earth metal (Mg2+, Ca2+), ammonium and inorganic anions (Cl-, H2PO4-, Br-, NO2-, I-, IO3-, NO3-, ClO4-, SCN-) was tested in aqueous solutions of sulfuric, perchloric, sulfosalicylic, citric, oxalic, maleic and aspartic acids with conductimetric detection. The effect of eluent pH, together with the concentration and characteristics of the eluting ions, were studied. Under optimum conditions (0.3 mmol dm(-3) H2SO4-0.2 mmol dm(-3) Li2SO4 eluent), the simultaneous separation of three anions (Cl-, H2PO4-, NO3-) and four cations (Na+, K+, Mg2+, Ca2+), on a PolyCAT A column (200 x 4.6 mm id, 5 microm film thickness) was achieved in 9 min.  相似文献   

6.
Nakatani N  Kozaki D  Tanaka K 《色谱》2012,30(4):365-368
In this study,our recent work on advanced ion chromatographic methods for the simultaneous determination of inorganic ionic species such as common anions(SO2-4,Cl-and NO-3) and cations(Na+,NH+4,K+,Mg2+,and Ca2+),nutrients(phosphate and silicate) and hydrogen ion/alkalinity are summarized first.Then,the applications using these methods for monitoring environmental water quality are also presented.For the determination of common anions and cations with nutrients,the separation was successfully performed by a polymethacrylate-based weakly acidic cation-exchange column of TSKgel Super IC-A/C(Tosoh,150 mm×6.0 mm i.d.) and a mixture solution of 100 mmol/L ascorbic acid and 4 mmol/L 18-crown-6 as acidic eluent with dual detection of conductivity and spectrophotometry.For the determination of hydrogen ion/alkalinity,the separation was conducted by TSKgel ODS-100Z column(Tosoh,150 mm×4.5 mm i.d.) modified with lithium dodecylsulfate and an eluent of 40 mmol/L LiCl/0.1 mmol/L lithium dodecylsulfate/0.05 mmol/L H2SO4 with conductivity detector.The differences of ion concentration between untreated and treated wastewater showed the variation of ionic species during biological treatment process in a sewage treatment plant.Occurrence and distribution of water-quality conditions were related to the bioavailability and human activity in watershed.From these results,our advanced ion chromatographic methods have contributed significantly for water quality monitoring of environmental waters.  相似文献   

7.
Hu W  Hasebe K  Tanaka K  Inoue S  Nagai M 《The Analyst》2000,125(12):2160-2162
The hydronium ion (H3O+), the most essential species to every field of chemistry, was successfully separated from other cations. This major goal was achieved by a HPLC approach in which a reversed-phase ODS which had been initially modified with dodecylsulfate was used as the stationary phase and an aqueous KNO3 solution was used as the mobile phase. Of all tested monovalent cations (analyte ions), the hydronium ion (H3O+) showed the highest affinity towards the stationary phase, followed by NH4+, Na+, and then Li+. The hydronium ion, after the separation, was directly detected using conductivity and the detection signal (conductivity) was in linear proportion (linear range 7.8 x 10(-4)-0.45 M; injection volume, 100 microL) to the concentration of the acid species of the tested sample. This proposed HPLC method was applicable to separate/detect H3O+ from both strong and weak acidic samples.  相似文献   

8.
离子色谱法测定饲料中氯化胆碱和三甲胺的含量   总被引:12,自引:0,他引:12  
丁永胜  牟世芬 《色谱》2004,22(2):174-176
建立了离子色谱法测定饲料中氯化胆碱含量及鉴别饲料中氯化胆碱及掺假物三甲胺的方法。选用IonPac CS12阳离子交换色谱柱(250 mm×4 mm i.d.)和8.5 mmol/L H2SO4淋洗液,抑制型电导检测,在16 min内分离测定了包括胆碱和三甲胺在内的8种阳离子。胆碱和三甲胺的最小检出限分别为0.1 mg/L和0.05 mg/L。方法回收率为99.25%~102.5%。该方法具有灵敏度高、选择性强、操作简单等优点。  相似文献   

9.
Arai K  Mori M  Hironaga T  Itabashi H  Tanaka K 《色谱》2012,30(4):404-408
A combination of hydrophilic interaction chromatographic(HILIC) column and a weakly acidic cation-exchange resin(WCX) column was used for simultaneous separation of inorganic anions and cations by ion chromatography(IC).Firstly,the capability of HILIC column for the separation of analyte ions was evaluated under acidic eluent conditions.The columns used were SeQuant ZIC-HILIC(ZIC-HILIC) with a sulfobetaine-zwitterion stationary phase(ZIC-HILIC) and Acclaim HILIC-10 with a diol stationary phase(HILIC-10).When using tartaric acid as the eluent,the HILIC columns indicated strong retentions for anions,based on ion-pair interaction.Especially,HILIC-10 could strongly retain anions compared with ZIC-HILIC.The selectivity for analyte anions of HILIC-10 with 5 mmol/L tartaric acid eluent was in the order of I-> NO-3 > Br-> Cl-> H2PO-4.However,since HILIC-10 could not separate analyte cations,a WCX column(TSKgel Super IC-A/C) was connected after the HILIC column in series.The combination column system of HILIC and WCX columns could successfully separate ten ions(Na+,NH+4,K+,Mg2+,Ca2+,H2PO-4,Cl-,Br-,NO-3 and I-) with elution of 4 mmol/L tartaric acid plus 8 mmol/L 18-crown-6.The relative standard deviations(RSDs) of analyte ions by the system were in the ranges of 0.02%-0.05% in retention times and 0.18%-5.3% in peak areas through three-time successive injections.The limits of detection at signal-to-noise ratio of 3 were 0.24-0.30 μmol/L for the cations and 0.31-1.2 μmol/L for the anions.This system was applied for the simultaneous determination of the cations and the anions in a vegetable juice sample with satisfactory results.  相似文献   

10.
An ion-chromatographic (IC) system with high selectivity for separation of nitrite is described. It is analogous to the EIC (electrostatic IC) previously reported and was established using 3-(N,N-dimethylstearylammonio)propanesulfonate (C23H49NO3S, a sulfobetaine type of zwitterionic surfactants) as the stationary phase and dilute aqueous HCl solutions as the mobile phase. Five inorganic anions, sulfate, chloride, bromide, nitrate, and nitrite were chosen as the model analytes and were analyzed using this EIC system. Sulfate was always eluted first, followed by chloride, bromide and nitrate. Nitrite, however, could be eluted either before or after nitrate, depending on the concentration of HCl in the eluent. An elution order nitrate< nitrite was always obtained simply by using >3 mmol L(-1) HCl as the eluent. For nitrite the detection limit was better than 2.1 x 10(-7) mol L(-1) (100 microL sample injection volume, S/N=3, UV at 210 nm). Bromide and nitrate could also be separated under these HPLC conditions. The detection limit for bromide was 7.2 x 10(-8) mol L(-1) and for nitrate 6.5 x 10(-8) mol L(-1). Both nitrite and nitrate in real seawater samples were successfully determined with direct sample injection using this EIC system.  相似文献   

11.
The application of unmodified silica gel (Super Micro Bead Silica Gel B-5, SMBSG B-5) as a cation-exchange stationary phase in ion chromatography with indirect photometric detection (IC-IPD) for the separation of common mono- and divalent cations (Li+, Na+, NH4+, K+, Mg2+ and Ca2+) was carried out using various aromatic monoamines [tyramine [4-(2-aminoethyl)phenol], benzylamine, phenylethylamine, 2-methylpyridine and 2,6-dimethylpyridine] as eluents. When using these amines as eluents, the peak resolution between these mono- and divalent cations was not quite satisfactory and the peak shapes of NH4+ and K+ were largely destroyed on the SMBSG B-5 silica gel column. Hence, the application of SMBSG B-5 silica gel calcinated at 200, 400, 600, 800 and 1000 degrees C for 5 h in the IC-IPD was carried out. The peak shapes of the monovalent cations were greatly improved with increasing calcination temperature and, as a result, symmetrical peaks of these mono- and divalent cations were obtained on the SMBSG B-5 silica gel calcinated at 1000 degrees C as the stationary phase. In contrast, the peak resolution between these mono- and divalent cations was not improved. Therefore, crown ethers [18-crown-6 (1,4,7,10,13,15-hexaoxacyclooctadecane), 15-crown-5 (1,4,7,10,13-pentaoxacyclopentadecane)] were added to the eluent for the complete separation of these mono- and divalent cations. Excellent simultaneous separation and highly sensitive detection at 275 nm were achieved in 25 min on a column (150x4.6 mm I.D.) packed with SMBSG B-5 silica gel calcinated at 1000 degrees C by elution with 0.75 mM tyramine-0.25 mM oxalic acid at pH 5.0 containing either 1.0 mM 18-crown-6 or 10 mM 15-crown-5.  相似文献   

12.
Tetraborate is investigated as the eluent ion for suppressed electrostatic ion chromatography (EIC) using a zwitterionic stationary phase. Good separation of a range of inorganic anions (SO4(2-), Cl-, NO3-, Br-, NO3-, ClO3-, and I-) was obtained, with detection limits for highly conducting ions (SO4(2-), Cl-, NO2-, Br- , and NO3-) being less than 8 x 10(-8) M, and for weakly conducting anions (ClO3- and I-) being 2.7 x 10(-7) and 5.8 x 10(-7) M, respectively. Calibration curves were linear up to 1.8 mM of each analyte. Retention times were found to increase with increasing eluent concentration and a linear relationship was observed between log k' and log[Na2B4O7] for all analytes. This behaviour is attributed to the progressive formation of a binary electrical double layer at the surface of the zwitterionic stationary phase. Retention times of analytes could be manipulated by varying the concentration of the eluent. This new suppressed-EIC system was applied to the determination of inorganic anions (SO4(-2) , CI-, NO3-, NO2-, and Br-) in snow and rainwater samples.  相似文献   

13.
反相高效液相色谱法同时测定镉、铅、铜和锌   总被引:12,自引:1,他引:11  
尹江伟  王光建  肖志芳 《色谱》2000,18(5):436-438
 研究了meso-四(对羟基苯基)卟啉为柱前衍生化试剂与Cd2+,Pb2+,Cu2+和Zn2+离子的配合反应条件及配合物在C18色谱柱上的分离条件,建立了反相高效液相色谱快速分离光度检测Cd2+,Pb2+,Cu2+和Zn2+的新方法。配合物和试剂在15 min内出峰完毕。4种离子的检出限为: Cd2+0.02 ng,Pb2+0.02 ng, Cu2+0.02 ng,Zn2+0.12 ng;线性范围为:Cd2+0.8 μg/L~150 μg/L,Pb2+0.8 μg/L~300 μg/L,Cu2+0.8 μg/L~500 μg/L,Zn2+5.0 μg/L~1 000 μg/L;方法的日内相对标准偏差为:2.8%~4.8%,测定低、中、高3个浓度的日间相对标准偏差为3.7%~9.7%。  相似文献   

14.
仰蜀薰  仝华翔 《化学学报》1987,45(7):711-714
Fe(II) induces the reaction between Tl3+ and H2O2. The rate of reaction is linearly proportional to the concentration of Fe2+ in the range 2.5 ?10-9-2.5 ?10-8 mol dm-3 (20? and 5 ?10-9-5 ?10-8 mol dm-3 (15?. The standard deviation is less than 0.071 ?10-8. A 1000-fold excess of Zn2+, Cd2+, Mg2+, Ni2+, Pb2+, Ba2+, Ca2+, Li+, Na+, Ag+, NO3-, SO42-, AcO-, HPO42-, 500-fold excess of Al3+, Fe3+, Co2+, Hg2+ and 100-fold excess of Ti4+, Cr3+, Cu2+, Br-, Cl- can be tolerated, but reducing agents such as (NH2)2SO4, NH2OH.HCl interfered. This kinetic method was applied to determine Fe(II) in standard zinc sample and fountain water, with satisfactory results.  相似文献   

15.
The application of laboratory-made aluminium-adsorbing silica gel (Al-Silica) as a cation-exchange stationary phase to ion chromatography-indirect photometric detection (IC-IPD) for common mono- and divalent cations (Li+, Na+, NH+, K+, Mg2+ and Ca2+) was carried out by using protonated tyramine (4-aminoethylphenol) as eluent ion. When using 1.2 mM tyramine-0.2 mM oxalic acid at pH 4.5 as eluent, incomplete separation of the monovalent cations and complete separation of the divalent cations were achieved in 17 min. Then, the addition of crown ethers in the eluent was carried out for the complete separation of the mono- and divalent cations. As a result, when using 1.2 mM tyramine--0.2 mM oxalic acid at pH 4.5 containing either 5 mM 15-crown-5 (1,4,7,10,13-pentaoxacyclopentadecane) or 0.5 mM and 18-crown-6 (1,4,7,10,13,16-hexaoxacyclooctadecane) as eluent, excellently simultaneous separation of these cations was achieved in 21 min. The proposed IC-IPD was successfully applied to the determination of major cations in natural water samples.  相似文献   

16.
The high-speed determination of hydrogen, magnesium and calcium ions by ion chromatography (IC) is demonstrated on a monolithic octadecyl-boned silica (ODS) column coated with lithium dodecylsulfate (Li-DS). This stationary phase, when used in conjunction with a 2 mM ethylenediamine and 0.1 mM Li-DS solution as eluent at pH 6.0, was found to be suitable for the rapid and efficient separation of hydrogen and magnesium and calcium in the order H+ < Mg2+ < Ca2+ within 4 min at a flow rate of 4.0 ml/min. Under the conditions, linear calibration plots of conductivity versus concentration were obtained for the cations over about three orders of magnitude, and the detection limits were 1 microM for H+, 2 microM for Mg2+ and Ca2+. Rainwater was analyzed directly using this IC system with satisfactory results.  相似文献   

17.
Optimum conditions for the reversed-phase liquid chromatographic separation of uranium as U(VI)-F(-)-(5-Br-PADAP) [5-Br-PADAP is 2-(5-bromo-2-pyridylazo)-5-diethylaminophenol] ternary complex on the end-capped C18 column were evaluated. The developed sensitive, selective and versatile method allows to determine uranium in the wide concentration range 0.2-120.0 mug ml(-1) (detection limit, DL, is 0.15 mug ml(-1) for 20 mul loop). Solvent mixture, acetonitrile+water (65+35, v/v) containing fluoride in concentration 3x10(-3) mol l(-1) (pH 5.5) was used as eluent. Double action of fluoride present in eluent - as stabilising agent of the ternary system and modifier of the stationary phase was evaluated. In order to prove appearance of the modifying effect of fluoride on the stationary phase the new chromatographic probe - system Zr(IV)-(5-Br-PADAP)/Zr(IV)-F(-)-(5-Br-PADAP) was introduced as a tool for the detection of F(-) presence on the surface.  相似文献   

18.
丁明玉  陈培榕 《分析化学》1998,26(4):425-427
发现以酒石酸和吡啶二甲酸等羧酸水溶液作淋洗剂时,钠,铵,钾,镁和钙等碱金属及碱土金属离子在ODS反相高效液相色谱柱上有明显的保留,而且相互之间能达到一定程度的分离。单独用分配或疏水作用等反相高效液相色谱的保留机理难以解释其保留行为。为此,作者提出了动态包固定相机理,即认为羧酸根阴离子因其疏水性在ODS固定相有保留,在固定相表面形成具有羧酸基阳离子交换树脂功能的动态包覆固定相。  相似文献   

19.
The association reactions, C4H2(+) + C2H2 and C4H3(+) + C2H2 have been examined at pressures between 8 x 10(-8) and 1 x 10(-4) Torr at 298 K in an ion cyclotron resonance mass spectrometer. Association occurred via two different mechanisms. At pressures below approximately 2 x 10(-6) Torr, the association was bimolecular having rate coefficients k2 = 2.7 x 10(-10) cm3 s-1 and 2.0 x 10(-10) cm3 s-1 for C4H2+ and C4H3+, respectively. At pressures above approximately 2 x 10(-6) Torr, termolecular association was observed with rate coefficients, k3 = 5.7 x 10(-23) cm6 s-1 and 1.3 x 10(-23) cm6 s-1 for C4H2+ and C4H3+, respectively, when M = C2H2. The termolecular rate constants with N2, Ar, Ne, and He as the third body, M, are also reported. We propose that the low pressure bimolecular association process was the result of radiative stabilization of the complex and the termolecular association process was the result of collisional stabilization. Elementary rate coefficients were obtained and the lifetime of the collision complex was > or = 57 microseconds for (C6H4+)* and > or = 18 microseconds for (C6H5+)*. At pressures below 1 x 10(-6) Torr, approximately 11% of the (C6H4+)* were stabilized by photon emission and the remaining approximately 89% reverted back to reactants, while approximately 24% of the (C6H5+)* were stabilized by photon emission and the remaining approximately 76% reverted back to reactants. The ionic products of the C2H2(+) + C2H2 reaction, C4H2+ and C4H3+, were found to be formed with enough internal energy that they did not react by the radiative association channel until relaxed by several nonreactive collisions with the bath gas.  相似文献   

20.
An amperometric detector based on the chemical modification of Nafion and indium (III) hexacyanoferrate (II, III) thin film (Nafion/In-CN-Fe) onto a glassy carbon (GC) electrode, was first successfully used for the determination of electroinactive cations (Li+, Na+, K+, Rb+, Cs+, NH4+) in single column ion chromatography (IC). A set of well-defined peaks of electroinactive cations was obtained. The detection limits of the cations are 8.9 x 10(-6) mol/L for Li+, 2.3 x 10(-6) mol/L for Na+, 5.2 x 10(-6) mol/L for K+, 4.8 x 10(-6) mol/L for Rb+, 4.0 x 10(-6) mol/L for Cs+ and 5.3 x 10(-6) mol/L for NH4+ at a single-to-noise ratio of 3. The proposed method was quick, sensitive and simple. The cations in rainwater and mineral water were successfully analyzed by this method.  相似文献   