首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Anajafi  Z.  Naseri  M.  Marini  S.  Espro  C.  Iannazzo  D.  Leonardi  S. G.  Neri  G. 《Analytical and bioanalytical chemistry》2019,411(29):7681-7688

A new electrochemical sensor, based on NdFeO3 nanoparticles as electrocatalytic material, was proposed here for the detection of dopamine (DA). NdFeO3 nanoparticles were first synthesized by a simple thermal treatment method and subsequent annealing at high temperature (700 °C). The prepared electrocatalytic material has been characterized in detail by SEM-EDX, XRD, and Raman techniques. Characterization results display its sheet-like morphology, constituted by a porous network of very small orthorhombic NdFeO3 nanoparticles. NdFeO3 electrocatalytic material was then used to modify the working electrode of screen-printed carbon electrodes (SPCEs). Electrochemical tests demonstrated that NdFeO3– modified screen-printed carbon electrode (NdFeO3/SPCE) exhibited a remarkable enhancement of the dopamine electrooxidation, compared to the bare SPCE one. The analytical performance of the developed sensor has been evaluated for the detection of this analyte by means of the square-wave voltammetry (SWV) technique. The modified electrode showed two linear concentration ranges, from 0.5 to 100 μM and 150 to 400 μM, respectively, a limit of detection (LOD) of 0.27 μM (at S/N = 3), and good reproducibility, stability, and selectivity. Additionally, we also report an attempt made to propose the modified sensor for the simultaneous detection of dopamine and uric acid (UA). The procedure was also applied for the determination of dopamine in spiked real samples. So, this paper reports for the first time the use of a modified NdFeO3 screen-printed electrode for developing an electrochemical sensor for the quantification of important biomolecules.

Graphical abstract

  相似文献   

2.

We report a novel, fast, and automatic SPME-based method capable of extracting a small molecule-drug conjugate (SMDC) from biological matrices. Our method relies on the extraction of the drug conjugate followed by direct elution into an electrospray mass spectrometer (ESI-MS) source for qualitative and quantitative analysis. We designed a tool for extracting the targeting head of a recently synthesized SMDC, which includes acetazolamide (AAZ) as high-affinity ligand specific to carbonic anhydrase IX. Specificity of the extraction was achieved through systematic optimization. The design of the extraction tool is based on noncovalent and reversible interaction between AAZ and CAII that is immobilized on the SPME extraction phase. Using this approach, we showed a 330% rise in extracted AAZ signal intensity compared to a control, which was performed in the absence of CAII. A linear dynamic range from 1.2 to 25 μg/ml was found. The limits of detection (LOD) of extracted AAZ from phosphate-buffered saline (PBS) and human plasma were 0.4 and 1.2 μg/ml, respectively. This with a relative standard deviation of less than 14% (n = 40) covers the therapeutic range.

Graphical abstract

  相似文献   

3.
He  Yu  Wang  Shuo  Wang  Junping 《Analytical and bioanalytical chemistry》2019,411(28):7481-7487

Folic acid (FA) is an essential vitamin in humans, and thus, rapid, accurate, and sensitive methods for its quantification in different biological samples are needed. This work describes a novel, simple, and effective dual-emission fluorescence nanoprobe for FA detection and quantification. The probe was covalently linked to amino-modified orange quantum dots (QDs) and carboxyl-modified blue graphene quantum dots (GQDs). The resulting material exhibited two emission peaks at 401 and 605 nm upon excitation at 310 nm. The probe had good selectivity and sensitivity toward FA with an exceptionally low detection limit (LOD = 0.09 nM). This probe was effectively used to quantify FA in animal serum samples. The method has potential utility for FA analysis in different types of biological samples.

Graphical abstract

  相似文献   

4.
Wei  Liping  Tian  Yi  Yan  Wenrong  Cheung  Kawai  Ho  Derek 《Analytical and bioanalytical chemistry》2019,411(16):3641-3652

Liquid-core waveguide (LCW) has many advantages such as the elimination of optical artifacts typically exhibited in systems employing lenses and filters. However, due to the effect of temporal dispersion, LCWs are typically employed in steady-state fluorescence detection microsystems rather than in fluorescence lifetime measurement (FLM) systems. In this paper, we present a compact liquid-core waveguide time-correlated single-photon counting (LCW-TCSPC) sensor for FLM. The propagation of excitation within the LCW is analyzed both analytically and in simulations, with results in agreement with experimental characterization. Results reveal an optimal region within the LCW for highly accurate FLM. The proposed prototype achieves excellent excitation rejection and low temporal dispersion as a result of optimization of the propagation length of the excitation within the LCW. The prototype achieves a detection limit of 5 nM for Coumarin 6 in dimethyl sulfoxide with < 3% lifetime error. The techniques proposed for analyzing the LCW for TCSPC based FLM and prototype demonstration pave the way for developing high-performance fluorescence lifetime measurement for microfluidics and point-of-care applications.

A compact liquid-core waveguide time-correlated single-photon counting (LCW-TCSPC) sensor for fluorescence lifetime measurement (FLM) is presented. Results reveal an optimal propagation length region within the LCW for highly accurate FLM. The prototype achieves a detection limit of 5 nM for Coumarin 6 in dimethyl sulfoxide with < 3% lifetime error.

  相似文献   

5.

This work reports on further development of an inhibition electrochemical sensor array based on immobilized bacteria for the preliminary detection of a wide range of organic and inorganic pollutants, such as heavy metal salts (HgCl2, PbCl2, CdCl2), pesticides (atrazine, simazine, DDVP), and petrochemicals (hexane, octane, pentane, toluene, pyrene, and ethanol) in water. A series of DC and AC electrochemical measurements, e.g., cyclic voltammograms and impedance spectroscopy, were carried out on screen-printed gold electrodes with three types of bacteria, namely Escherichia coli, Shewanella oneidensis, and Methylococcus capsulatus, immobilized via poly l-lysine. The results obtained showed a possibility of pattern recognition of the above pollutants by their inhibition effect on the three bacteria used. The analysis of a large amount of experimental data was carried out using an artificial neural network (ANN) programme for more accurate identification of pollutants as well as the estimation of their concentration. The results are encouraging for the development of a simple and cost-effective biosensing technology for preliminary in-field analysis (screening) of water samples for the presence of environmental pollutants.

Graphical abstract

  相似文献   

6.

We report on the successful application of carboxyl-rich plasma polymerized (PP) films as a matrix layer for bioreceptor immobilization in surface plasmon resonance (SPR) immunosensing. Composition and chemical properties of the carboxyl-rich PP films deposited from a mixture of maleic anhydride and acetylene were investigated. Changes in the films stored in air, water, and buffer were studied and the involved chemical changes were described. Performance in SPR immunosensing was evaluated on interactions of human serum albumin (HSA) with a specific monoclonal antibody. The comparison with the mixed self-assembled monolayer of mercaptoundecanoic acid and mercaptohexanol (MUA/MCH) and one of the most widely used surfaces for SPR, the 2D and 3D carboxymethylated dextran (CMD), was presented to show the efficacy of plasma polymerized matrix layers for biosensing. The PP film-based SPR immunosensor provided a similar detection limit of HSA (100 ng/mL) as MUA/MCH- (100 ng/mL) and 3D CMD (50 ng/mL)-based sensors. However, the response levels were about twice higher in case of the PP film-based immunosensor than in case of MUA/MCH-based alternative. The PP film surfaces had similar binding capacity towards antibody as the 3D CMD layers. The response of PP film-based sensor towards HSA was comparable to 3D CMD-based sensor up to 2.5 μg/mL. For the higher concentrations (> 10 μg/mL), the response of PP film-based immunosensor was lower due to inaccessibility of active sites of the immobilized antibody inside the flat PP film surface. We have demonstrated that due to its high stability and cost-effective straightforward preparation, the carboxyl-rich PP films represent an efficient alternative to self-assembled monolayers (SAM) and dextran-based layers in label-free immunosensing.

Graphical abstract

  相似文献   

7.

The cyanate anion (CNO), formed spontaneously within cells from urea and carbamoyl phosphate, usually functions as a biomarker of some diseases such as chronic kidney disease. Therefore, accurate determination of CNO is highly demanded. Herein, a 3-amino-2-naphthoic acid-based “turn-on” fluorescence probe was developed for specific detection of CNO. Upon the addition of sodium cyanate, the weak-fluorescent 3-amino-2-naphthoic acid could react with CNO, which triggered intense emission of green fluorescence. And up to 9-fold fluorescence enhancement was observed. The fluorescence enhancement ratios displayed a good linear relationship with the concentrations of CNO in the range of 0.5–200 μM. The high selectivity and sensitivity for CNO detection were investigated with the detection limit as low as 260 nM. The probe was further successfully applied to determine CNO in real samples such as tap water, human urine and serum samples, which offered a promising approach in practical applications.

Graphical abstract

  相似文献   

8.

A novel SBA-15-based fluorescent sensor, SBA-PI: mesoporous SBA-15 structure modified with iminostilbene groups, was designed, synthesized, and characterized by Fourier transform-infrared spectroscopy (FT-IR), ultraviolet–visible spectroscopy, field emission scanning electron microscopy (FESEM), transmission electron microscopy (TEM), energy-dispersive X-ray spectroscopy (EDS), thermogravimetric analysis (TGA), low-angle X-ray diffraction techniques (low-angle XRD), and N2 adsorption–desorption techniques. The SBA-PI as a sensor with a selective behavior for detection of Cu2+ comprises iminostilbene carbonyl as the fluorophore group. The SBA-PI sensor displays an excellent fluorescence response in aqueous solutions and the fluorescence intensity quenches remarkably upon addition of Cu2+. Other common interfering ions even at high concentration ratio showed either no or very small changes in the fluorescence intensity of SBA-PI in the absence of Cu2+. A limit of detection of 8.7 × 10−9 M for Cu2+ indicated that this fluorescence sensor has a high sensitivity and selectivity toward the target copper (II) ion. The fabricated Cu2+ sensor was successfully applied for the determination of the Cu2+ in human blood samples without any significant interference. With the selective analysis of Cu2+ ions down to 0.9 nM in blood, the sensor is a promising and a novel detection candidate for Cu2+ and can be applied in the clinical laboratory. A reversibility and accuracy in the fluorescence behavior of the sensor was found in the presence of I¯ that was described as a masking agent for Cu2+.

Graphical abstract

  相似文献   

9.
Hou  Rui  Li  Yilan  Sui  Zhigang  Yuan  Huiming  Yang  Kaiguang  Liang  Zhen  Zhang  Lihua  Zhang  Yukui 《Analytical and bioanalytical chemistry》2019,411(21):5351-5361

Exosomes are membrane-bound vesicles secreted by cells, and contain various important biological molecules, such as lipids, proteins, messenger RNAs, microRNAs, and noncoding RNAs. Emerging evidence demonstrates that proteomic analysis of exosomes is of great significance in studying metabolic diseases, tumor metastasis, immune regulation, and so forth. However, exosome proteomic analysis has high requirements with regard to the purity of collected exosomes. Here recent advances in the methods for isolating exosomes and their applications in proteomic analysis are summarized.

Graphical abstract

  相似文献   

10.

In this work, a straightforward analytical approach based on headspace solid-phase microextraction coupled with gas chromatography-mass spectrometry was developed for the analysis of salivary volatile organic compounds without any prior derivatization step. With a sample volume of 500 μL, optimal conditions were achieved by allowing the sample to equilibrate for 10 min at 50 °C and then extracting the samples for 10 min at the same temperature, using a carboxen/polydimethylsiloxane fibre. The method allowed the simultaneous identification and quantification of 20 compounds in sample headspace, including short-chain fatty acids and their derivatives which are commonly analysed after analyte derivatization. The proof of applicability of the methodology was performed with a case study regarding the analysis of the dynamics of volatile metabolites in saliva of a single subject undergoing 5-day treatment with rifaximin antibiotic. Non-stimulated saliva samples were collected over 3 weeks from a nominally healthy volunteer before, during, and after antibiotic treatment. The variations of some metabolites, known to be produced by the microbiota and by bacteria that are susceptible to antibiotics, suggest that the study of the dynamics of salivary metabolites can be an excellent indirect method for analysing the gut microbiota. This approach is novel from an analytical standpoint, and it encourages further studies combining saliva metabolite profiles and gut microbiota dynamics.

Graphical abstract

  相似文献   

11.
Zhang  Xue  Yu  Hong  Cai  Ya-qi 《Analytical and bioanalytical chemistry》2019,411(16):3427-3434

An ion chromatography and solid-phase extraction method has been applied for the separation and detection of morpholinium cations in environmental water samples. The water samples were purified and enriched by a UF-SCX sulfonic acid extraction column and eluted with 0.5 mol L−1 phosphoric acid/sodium dihydrogen phosphate buffer solution/55% methanol. The target compounds were separated on a carboxylic acid cation exchange column with 5.0 mmol L−1 methane sulfonic acid/2% acetonitrile as the mobile phase and direct conductivity detection. The method has been successfully applied to extract morpholinium cations from spiked water samples of Songhua River, Hulan River, East Lake, and Mopanshan Reservoir in China with the recoveries ranging from 75.0% to 98.3%. The relative standard deviations of intraday precision and interday precision are 2.1% and 5.9% or less, respectively. Using this method it is possible to preconcentrate water samples to 0.01–0.04 mg L−1. The results show that the method is applicable to detection of morpholinium ionic liquid cations in environmental water samples and provides a new approach for monitoring ionic liquids in environmental water.

The analysis procedure of morpholinium ionic liquids in environmental water samples.

  相似文献   

12.
Hu  Yuefang  Lin  Liyun  Li  Jinfang  Ye  Jianzhi 《Analytical and bioanalytical chemistry》2019,411(16):3603-3612

A facile single hydrothermal method was developed to synthetize P,N codoped carbon dots (P,N/CDs), which show strong and stable fluorescence, good water solubility, low toxicity and good biocompatibility. Hence, a novel and efficient “off-on” P,N/CDs fluorescent probe was developed for the highly sensitive detection of lipoic acid (LA) for the first time. The fluorescence of the P,N/CDs was quenched by Cu2+ forming a P,N/CDs-Cu2+ complex, which acted as the “off” process, but Cu2+ could be removed by LA, due to stronger chelating between LA and Cu2+, forming a more stable complex, which recovered the fluorescence of the P,N/CDs, in order to achieve the “on” process. Under optimal conditions, the concentration of LA and the increased fluorescence intensity of the P,N/CDs-Cu2+ complex displayed a good linear relationship within the range of 0.05–28 μM, with a detection limit (S/N = 3) of 0.02 μM. The established “off-on” fluorescent probe was successfully applied to the analysis of LA in urine samples. The average recoveries were in the range of 98.3–101.5%, with a relative standard deviations of less than 3.1%. In addition, the P,N/CDs were also successfully applied to cellular dual-color imaging of live T24 cells. The results show that the P,N/CDs have great application potential in clinical diagnosis, bioassay and bioimaging.

Graphical abstract

  相似文献   

13.

In this paper, we present a new colorimetric technique as a novel assay for the easy and direct detection of α-amylase activity. This detection system utilizes the interaction of α-amylase with starch that is supporting copper/gold (Cu/Au) nanoclusters. The Cu/Au nanoclusters are synthesized using starch as a stabilizing agent at room temperature. These nanoclusters show robust peroxidase-like activity and are able to catalyze the oxidation of TMB (3,3,5,5-tetramethylbenzidine) in the presence of hydrogen peroxide (H2O2), leading to the generation of a blue-colored solution. The α-amylase detection mechanism is based on the digestion of the starch by α-amylase, which results in nanocluster aggregation, leading to increased nanoparticle size and thus decreased peroxidase-like activity of the Cu/Au NCs. Experiments showed that the gradual addition of α-amylase causes the peroxidase activity to decrease step by step in a linear fashion. Using this method, colorimetric sensing of α-amylase was achieved with a detection limit (LOD) of 0.04 U/mL and a linear range of 0.1–10 U/mL. This method is significantly selective for α-amylase and could be affordably and conveniently applied to the detection of α-amylase in blood serum.

Graphical Abstract

  相似文献   

14.

The i-motif is a biologically relevant non-canonical DNA structure formed by cytosine-rich sequences. Despite the importance of the factors affecting the formation/stability of such a structure, like pH, cation type and concentration, no systematic study that simultaneously analysed their effect on the i-motif in vitro has been carried out so far. Therefore, here we report a systematic study that aims to evaluate the effect of these factors, and their possible interaction, on the formation of an i-motif structure. Our results confirm that pH plays the main role in i-motif formation. However, we demonstrate that the effect of the cation concentration on the i-motif is strictly dependent on the pH, while no significant differences are observed among the investigated cation types.

Graphical abstract

  相似文献   

15.

A novel rhodamine–tryptamine conjugate–based fluorescent and chromogenic chemosensor (RTS) for detection of Hg2+ present in water was reported. After gradual addition of Hg2+ in aqueous methanol solution of RTS, a strong orange fluorescence and deep-pink coloration were observed. The probe showed high selectivity towards Hg2+ compared to other competitive metal ions. The 1:1 binding stoichiometry between RTS and Hg2+ was established by Job’s plot analysis and mass spectroscopy. Initial studies showed that the synthesized probe RTS possessed fair non-toxicity and effectively passed through cell walls of model cell systems, viz., human neuroblastoma (SHSY5Y) cells and cervical cells (HeLa) to detect intercellular Hg2+ ions, signifying its utility in biological system. The limit of detection (LOD) was found to be 2.1 nM or 0.42 ppb by fluorescence titration. Additionally, the potential relevance of synthesized chemosensor for detecting Hg2+ ions in environmental water samples has been demonstrated.

  相似文献   

16.

A simple method for the simultaneous quantification of meropenem and the recently approved β-lactamase inhibitor, vaborbactam, in human plasma and renal replacement therapy effluent (RRTE) was developed and validated. This antibiotic combination protects a primary β-lactam, meropenem, with a new β-lactamase inhibitor, and expands the limited options for treatment of multidrug-resistant Gram-negative infections. Meropenem, vaborbactam, and the internal standards [2H6]-meropenem and sulbactam in plasma and RRTE were processed using acetonitrile followed by a chromatographic separation on a Poroshell HPH-C18 column with a gradient elution of the mobile phases and monitored using mass spectrometry detection. The calibration range was 0.05 to 100 μg mL−1 for both meropenem and vaborbactam. The intra-day and inter-day precision and accuracy were less than 15% for both meropenem and vaborbactam and the recovery from plasma was 96% for both meropenem and vaborbactam and the recovery from RRTE was 93% and 103% for meropenem and vaborbactam, respectively. This methodology was successfully applied to an ex vivo characterisation study of the effects of renal replacement therapy modalities on the pharmacokinetics of meropenem and vaborbactam (Antimicrob Agents Chemother 62(10), 2018).

Graphical abstract

  相似文献   

17.

Graphite electrodes were modified with triangular (AuNTrs) or spherical (AuNPs) nanoparticles and further modified with fructose dehydrogenase (FDH). The present study reports the effect of the shape of these nanoparticles (NPs) on the catalytic current of immobilized FDH pointing out the different contributions on the mass transfer–limited and kinetically limited currents. The influence of the shape of the NPs on the mass transfer–limited and the kinetically limited current has been proved by using two different methods: a rotating disk electrode (RDE) and an electrode mounted in a wall jet flow-through electrochemical cell attached to a flow system. The advantages of using the wall jet flow system compared with the RDE system for kinetic investigations are as follows: no need to account for substrate consumption, especially in the case of desorption of enzyme, and studies of product-inhibited enzymes. The comparison reveals that virtually identical results can be obtained using either of the two techniques. The heterogeneous electron transfer (ET) rate constants (kS) were found to be 3.8 ± 0.3 s−1 and 0.9 ± 0.1 s−1, for triangular and spherical NPs, respectively. The improvement observed for the electrode modified with AuNTrs suggests a more effective enzyme-NP interaction, which can allocate a higher number of enzyme molecules on the electrode surface.

The shape of gold nanoparticles has a crucial effect on the catalytic current related to the oxidation of D-(-)-fructose to 5-keto-D-(-)-fructose occurring at the FDH-modified electrode surface. In particular, AuNTrs have a higher effect compared with the spherical one.

  相似文献   

18.
Qu  Qi  Lv  Yaying  Liu  Lingling  Row  Kyung Ho  Zhu  Tao 《Analytical and bioanalytical chemistry》2019,411(28):7489-7498

Hydrophilic and hydrophobic deep eutectic solvents (DESs) as “green” solvents were applied in this study for the microextraction of environmental samples. A series of DESs (five hydrophilic and three hydrophobic) were synthesized and characterized by Fourier transform infrared spectroscopy. Physicochemical property parameters of eight DESs including water solubility, density, conductivity, and freezing point were assessed. Compared with the performance of five hydrophilic DESs in water phase, the three hydrophobic DESs were more suitable for application in dispersive liquid-liquid microextraction for the determination of sulfonamides in water sample. In dispersive liquid-liquid microextraction process, analytical parameters including type and volume of extraction solvent, extraction time, and pH of water sample were investigated. Under optimum conditions, 60 μL of hydrophobic DESs was used for extraction for 2 min in pH = 7.0 sample. The linear ranges were 0.05–5.0 μg/mL for the four sulfonamides with the correlation coefficients in the range of 0.9991–0.9999. The limits of detection were in the range of 0.0005–0.0009 μg/mL and the limits of quantification were in the range of 0.0019–0.0033 μg/mL. The recoveries of the analytes of the proposed method for the spiked samples were 80.17–93.5%, with the relative standard deviation less than 6.31%. The results indicated that three hydrophobic DESs showed commendable performance for extraction of sulfonamides, and hydrophobic DES-based microextraction method was successfully applied for monitoring sulfonamides in water samples.

Graphical abstract

  相似文献   

19.

One of the main challenges in large-scale applications of molecularly imprinted polymers (MIPs) is the significant amount of template needed in polymer preparation. A new strategy based on room-temperature ionic liquids (RTILs) was suggested to solve this problem by reducing the amount of template in the polymerization recipe. The MIP was synthesized with a mixture of dimethyl sulfoxide and RTIL (1-butyl-3-methylimidazolium tetrafluoroborate) as porogen, in which chlorogenic acid (CGA) was used as template, 4-vinylpyridine (4-VP) as functional monomer, and ethylene glycol dimethacrylate (EDMA) as cross-linker. The influence of polymerization variables, including CGA concentrations, and the ratio of 4-VP to EDMA on imprinting effect were investigated comprehensively. Moreover, the properties involving the column permeability, the number of binding sites, and the polymer morphology of the CGA-MIP monoliths were studied thoroughly. The MIP monolith had an excellent column permeability (1.53 × 10−13 m2) and allowed an ultra-fast on-line SPE, which dramatically shortens the separation time (< 10 min) and improves the separation efficiency. At high flow velocity (5.0 mL min−1), 50 μL of the extract from Eucommia ulmoides leaves can be loaded directly on the CGA-MIP monoliths and CGA with high purity can be obtained with a recovery of 89.01 ± 0.05%. As a conclusion, the resulting RTIL-induced approach of preparing MIP may be an effective tool in fabricating MIP in a low-cost way.

  相似文献   

20.

We report the development of a fast and accurate fluorescence-based assay for amidine linked to cellulose membranes and Sepharose gel. The assay is founded on the glyoxal reaction, which involves reaction of an amidine group with glyoxal and an aromatic aldehyde, leading to the formation of a fluorophore that can be analyzed and quantified by fluorescence spectroscopy and imaging. While the assay has been reported previously for aromatic amidine estimation in solution phase, here we describe its adaptation and application to amidine linked to diverse forms of solid matrices, particularly benzamidine Sepharose and benzamidine-linked cellulose membranes. These functionalized porous matrices find important application in purification of serine proteases. The efficacy of a protein separation device is determined by, among other factors, the ligand (amidine) density. Hence, a sensitive and reproducible method for amidine quantitation in solid phase is needed. The glyoxal reaction was carried out on microbead-sized Sepharose gel and cellulose membranes. Calibration curves were developed for each phase, which established linearity in the range of 0–0.45 μmol per mL amidine for free amidine in solution, 0–0.45 μmol amidine per mL Sepharose gel, and 0–0.48 μmol per mL cellulose membrane. The assay showed high accuracy (~ 3.4% error), precision (RSD < 2%), and reproducibility. Finally, we show how this fluorescent labeling (glyoxal) method can provide a tool for imaging membranes and ligand distribution through confocal laser scanning microscopy.

Graphical abstract

  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号