首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 184 毫秒
1.
A PVC-membrane electrode based on a recently synthesized 18-membered macrocyclic diamide is presented. The electrode reveals a Nernstian potentiometric response for Co2+ over a wide concentration range (2.0 x 10(-6)-1.0 x 10(-2) M). The electrode has a response time of about 10 s and can be used for at least 2 months without any divergence. The proposed sensor revealed very good selectivities for Co2+ over a wide variety of other metal ions, and could be used over a wide pH range (3.0-8.0). The detection limit of the sensor is 6.0 x 10(-7) M. It was successfully applied to the direct determination and potentiometric titration of cobalt ion.  相似文献   

2.
Cadmium ion-selective electrode based on tetrathia-12-crown-4   总被引:1,自引:0,他引:1  
Shamsipur M  Mashhadizadeh MH 《Talanta》2001,53(5):1065-1071
A new polyvinylchloride membrane sensor for Cd(2+) ions based on tetrathia-12-crown-4 as an ionophore was prepared. The sensor exhibits a Nernstian response for cadmium ions over a wide concentration range (4.0 x 10(-7) to 1.0 x 10(-1) M) with a slope of 29+/-1 mV decade(-1). The limit of detection is 1.0 x 10(-7) M (0.01 ppm). It has a fast response time of <10 s and can be used for at least 6 weeks without any divergence in potential. The electrode can be used in the pH range from 2.5 to 8.5. The proposed sensor shows fairly good discriminating ability towards Cd(2+) ion in comparison with some alkali, alkaline earth, transition and heavy metal ions. It was successfully applied for the direct determination of Cd(2+) in solution and, as an indicator electrode, in potentiometric titration of cadmium ions.  相似文献   

3.
A PVC membrane incorporating p-tert-butyl calix[4]crown with imine units as an ionophore was prepared and used in an ion-selective electrode for the determination of mercury(II) ions. An electrode based on this ionophore showed a good potentiometric response for mercury(II) ions over a wide concentration range of 5.0 x 10(-5) - 1.0 x 10(-1) M with a near-Nernstian slope of 27.3 mV per decade. The detection limit of the electrode was 2.24 x 10(-5) M and the electrode worked well in the pH range of 1.3 - 4.0. The electrode showed a short response time of less than 20 s. The electrode also showed better selectivity for mercury(II) ions over many of the alkali (Na+, -1.69; K+, -1.54), alkaline-earth (Ca2+, -3.30; Ba2+, -3.32), and heavy metal ions (Co2+, -3.67; Ni2+, -3.43; Pb2+, -3.31; Fe3+, -1.82). Ag+ ion was found to be the strongest interfering ion. Also, sharp end points were obtained when the sensor was used as an indicator electrode for the potentiometric titration of mercury(II) ions with iodide and dichromate ions.  相似文献   

4.
A new PVC membrane mercury(II) ion electrode based on N,N-dimethylformamide-salicylacylhydrazone (DMFAS) as an ionophore is described, which shows excellent potentiometric response characteristics and displays a linear log[Hg(2+)] versus EMF response over a wide concentration range between 6.2 x 10(-7) and 8.0 x 10(-2) M with a Nerstian slope of 29.6 mV per decade and a detection limit of 5.0 x 10(-7) M. The response time for the electrode is less than 30 s and the electrode can be used for more than 2 months with less than a 2 mV observed divergence in a potentials. The proposed electrode exhibits very good selectivity for mercury(II) ions over many cations in a wide pH range (pH 1 - 4). The electrode was also applied to the determination of a mercury(II) ion in vegetables and in Azolla filiculoides.  相似文献   

5.
A cobalt(II) tetrakisphenylporphyrin (Co(II)TPP) film modified glassy carbon electrode (Co(II)TPP-GCE) was prepared by just coating Co(II)TPP solution on the surface of the electrode. It can be used for the simultaneous determination of ascorbic acid and uric acid. The anodic peaks of AA and UA can be separated well. Owing to the strongly hydrophobic property of porphyrin, the modified electrode has good stability and long life. The linear range for UA and AA were 2.0 x 10(-6)-1.0 x 10(-4) M and 9.0 x 10(-6)-2.0 x 10(-3) M with detection limits of 5.0 x 10(-7) and 5.0 x 10(-6) M, respectively. Furthermore, metalloporphyrins of other kinds were also used to construct modified electrodes. Their performances were inferior compared with that of the Co(II)TPP modified electrode.  相似文献   

6.
Abbaspour A  Moosavi SM 《Talanta》2002,56(1):91-96
The utility of carbon paste electrode modified with DTPT (3,4-dihydro-4,4,6-trimethyl-2(1H)-pyrimidine thione) for the potentiometric determination of Cu(II) in aqueous medium is demonstrated. The electrode exhibits linear response to Cu(II) over a wide concentration range (9.77x10(-7)-7.6x10(-2)) with Nernstian slope of 30+/-2 mV per decade. It has a response time of about 45 s and can be used for a period of two months with good reproducibility. The detection limit of this electrode was 7.0x10(-7) M. The proposed electrode shows a very good selectivity for Cu(II) over a wide variety of metal ions. This chemically modified carbon paste electrode was successfully used for the determination of Cu(II) in electronics waste sample solution.  相似文献   

7.
A cobalt(II) ion-selective membrane sensor has been fabricated from a poly vinyl chloride (PVC) matrix membrane containing a new oxime compound (oxime of 1-(2-oxocyclohexyl)-1,2-cyclohexanediol, OXCCD) as a neutral carrier, sodium tetraphenyl borate (NaTPB) as an anionic excluder and o-nitrophenyloctylether (o-NPOE) as a plasticizing solvent mediator. The membrane sensor exhibits a linear potential response in the concentration range of 1.0 x 10(-1) - 1.0 x 10(-6) M of Co2+. The electrode displays a Nernstian slope of 29.8 mV decade(-1) in the pH range of 3.5 - 8.0. The sensor also exhibits a fast response time of < 25 s. The detection limit of the proposed sensor is 9.0 x 10(-7) M (approximately 40 ng/ml), and it can be used over a period of two months. The selectivity of the sensor with respect to other cations (alkali, alkaline earth, transition and heavy metal ions) is excellent. The practical utility of the sensor has been demonstrated by using it as an indicator electrode in the potentiometric titration of Co2+ with EDTA and for the direct determination of Co(II) in wastewater of the electroplating industry.  相似文献   

8.
A new heterogeneous precipitate of an organic-inorganic composite cation-exchanger poly-o-toluidine Zr(IV) phosphate was utilized for the preparation of a Hg(II) ion-sensitive membrane electrode for the determination of Hg(II) ions in real aqueous as well as in real samples. The electrode showed good potentiometric response characteristics, and displayed a linear log[Hg(2+)] versus EMF response over a wide concentration range of 1 x 10(-1) - 1 x 10(-6) M with a Nernstian slope of 30 mV per decade change in concentration with a detection limit of 1 x 10(-6). The membrane electrode showed a very fast response time of 5 s and could be operated well in the pH range 2 - 8. The selectivity coefficients were determined by the mixed-solution method, and revealed that the electrode was selective in the presence of interfering cations; however most of these did not show significant interference in the concentration range of 1 x 10(-1) - 1 x 10(-4) M. The lifetime of the membrane electrode was observed to be 120 days. The analytical utility of this electrode was established by employing it as an indicator electrode in the potentiometric titrations of Hg(2+) ions from a synthetic mixture as well as drain water.  相似文献   

9.
A coated-wire ion-selective electrode (ISE) based on cyclam (1,4,8,11-tetraazacyclotetradecane) as a neutral carrier in a polyvinyl chloride (PVC) matrix was fabricated for the determination of Ag(I) ions. The coated-wire ISE exhibited a linear Nernstian response over the range 1 x 10(-1) to 1 x 10(-7) M with a slope of 59 +/- 2 mV per decade change and a detection limit of 5 x 10(-8) M. The ISE shows a greater preference for Ag over other cations with good precision. The electrode was selective towards Ag(I) ions in the presence of 13 different metal ions tested. The selectivity coefficients (K(ij)) were determined for Na(I), K(I), Mg(II), Ca(II), Ba(II), Mn(II), Co(II), Ni(II), Cu(II), Zn(II), Cd(II), Pb(II) and Hg(II). The selectivity coefficients of these cations are in the range of 10(-4) to 10(-2). This ISE was used for the determination of free silver and total silver in electroplating bath solutions, additives and brighteners.  相似文献   

10.
A cobalt(II) derivative was used as a suitable ionophore for the preparation of a polymeric membrane nitrite-selective electrode. The electrode reveals a Nemstian behavior over a very wide NO2- ion concentration range (1.0 x 10(-6)-1.0 x 10(-1) M) and a very low detection limit (5.0 x 10(-7) M). The potentiometric response is independent of the pH of solution in the pH range 4.0-9.5. The electrode shows advantages such as low resistance, fast response and, most importantly, good selectivity relative to a wide variety of inorganic and organic anions. In fact, the selectivity behavior of the proposed NO2- ion-selective electrode shows great improvements compared to the previously reported electrodes for nitrite ion. The proposed electrodes could be used for at least 2 months without any significant changes in potentials. The electrode was successfully applied to the determination of nitrate ion concentrations in sausage and milk samples.  相似文献   

11.
Strong luminescence CdS quantum dots (QDs) have been prepared and modified with l-cysteine by a facile seeds-assistant technique in water. They are water-soluble and highly stable in aqueous solution. CdS QDs evaluated as a luminescence probe for heavy and transition metal (HTM) ions in aqueous solution was systematically studied. Five HTM ions such as silver(I) ion, copper(II) ion, mercury(II) ion, cobalt(II) ion, and nickel(II) ion significantly influence the photophysics of the emission from the functionalized CdS QDs. Experiment results showed that the fluorescence emission from CdS QDs was enhanced significantly by silver ion without any spectral shift, while several other bivalent HTM ions, such as Hg(2+), Cu(2+), Co(2+), and Ni(2+), exhibited effective optical quenching effect on QDs. Moreover, an obvious red-shift of emission band was observed in the quenching of CdS QDs for Hg(2+) and Cu(2+) ions. Under the optimal conditions, the response was linearly proportional to the concentration of Ag(+) ion ranging from 1.25 x 10(-7) to 5.0 x 10(-6)molL(-1) with a detection limit of 2.0 x 10(-8)molL(-1). The concentration dependence of the quenching effect on functionalized QDs for the other four HTM ions could be well described by typical Stern-Volmer equation, with the linear response of CdS QDs emission proportional to the concentration ranging from 1.50 x 10(-8) to 7.50 x 10(-7)molL(-1) for Hg(2+) ion, 3.0 x 10(-7) to 1.0 x 10(-5)molL(-1) for Ni(2+) ion, 4.59 x 10(-8) to 2.295 x 10(-6)molL(-1) for Cu(2+) ion, and 1.20 x 10(-7) to 6.0 x 10(-6)molL(-1) Co(2+) ion, respectively. Based on the distinct optical properties of CdS QDs system with the five HTM ions, and the relatively wide linear range and rapid response to HTM ions, CdS QDs can be developed as a potential identified luminescence probe for familiar HTM ions detection in aqueous solution.  相似文献   

12.
Gholivand MB  Nozari N 《Talanta》2001,54(4):597-602
Poly(vinyl chloride) membrane electrode, that is highly selective and sensitive to Cu(II) ions, was developed by using 2,2'-dithiodianiline and dibutyl phthalate as carrier and plasticizer, respectively. The electrode exhibits good potentiometric response for Cu(II) over a wide concentration range (5.0x10(-2)-7.0x10(-7) mol l(-1)) with Nernstian slope of 30+/-1 mV per decade. The response time of the electrode is 10 s and it has been used for a period of one month and exhibits good selectivity towards Cu(2+) in comparison to alkali, alkaline earth, transition and heavy metal ions, with no interference caused by Pb(2+), Cd(2+) and Fe(+2) which are known to interfere with many other copper electrodes.  相似文献   

13.
A new solvent polymeric membrane electrode based on N,N'-bis-(dimethylaminobenzaldehyde)-glycine cobalt(II) [Co(II)-BDMABG] as a neutral carrier is described, which displays a preferential potentiometric response to iodide ion and an anti-Hofmeister selectivity sequence in the following order: I- > ClO4- > Sal- > SCN- > NO2- > Br- > NO3- > Cl- > SO3(2-) > SO4(2-). The electrode exhibits a near-Nernstian potential linear range of 9.0 x 10(-7)-1.0 x 10(-1) M with a detection limit of 6.8 x 10(-7) M and a slope of -53.0 mV/decade in pH 2.0 of a phosphate buffer solution at 20 degrees C. The response mechanism is discussed in view of the A.C. impedance technique and the UV spectroscopy technique. The electrode was successfully applied to the determination of iodide in Jialing River and Spring in Jinyun Mountains with satisfactory results.  相似文献   

14.
A new PVC membrane ion selective electrode which is highly selective towards Ni(II) ions was constructed using a Schiff base containing a binaphthyl moiety as the ionophore. The sensor exhibited a good Nernstian response for nickel ions over the concentration range 1.0x10(-1)-5.0x10(-6) M with a lower limit of detection of 1.3x10(-6) M. It has a fast response time and can be used for a period of 4 months with a good reproducibility. The sensor is suitable for use in aqueous solutions in a wide pH range of 3.6-7.4 and works satisfactorily in the presence of 25% (v/v) methanol or ethanol. The sensor shows high selectivity to nickel ions over a wide variety of cations. It has been successfully used as an indicator electrode in the potentiometric titration of nickel ions against EDTA and also for the direct determination of nickel content in real samples: effluent samples, chocolates and hydrogenated oils.  相似文献   

15.
Abbaspour A  Izadyar A 《Talanta》2001,53(5):1009-1013
A PVC-based membrane of 4-dimethylaminoazobenzene reveals a Nernstian potentiometric response (with slope of 19.5+/-0.6 mV/decade and a correlation coefficient of 0.999) for Cr(III) over a wide concentration range (1.66 x 10(-6)-1.0 x10(-2) mol dm(-3)). The potential of this electrode is independent of pH in the range of 3.0-5.5. It has a fast response time of about 10 s and was used for a period of 3 months with good reproducibility. The detection limits of this membrane electrode was 8 x 10(-7) M. the proposed electrode has been used as an indicator electrode in the potentiometric titration of Cr(III) with EDTA. This sensor exhibits a very good selectivities for Cr(III) over a wide variety of metal ions.  相似文献   

16.
Gupta VK  Prasad R  Kumar A 《Talanta》2003,60(1):149-160
Copper(II) complex of ethambutol (I) was prepared and used in the fabrication of Cu(2+) selective ISE membrane. The membrane having Cu(II)-ethambutol complex (I) as electroactive material, along with sodium tetraphenylborate (NaTPB) as anion discriminator, dioctylphthalate (DOP) as plasticizer in poly(vinyl chloride) (PVC) matrix in the percentage ratio 6:2:190:200 (I:NaTPB:DOP:PVC) (w/w) gave a linear response in the concentration range 7.94x10(-6) to 1.0x10(-1) M of Cu(2+) with a slope of 29.9+/-0.2 mV per decade of activity and a fast response time of 11+/-2 s. The sensor works well in the pH range 2.1-6.3 and could be satisfactorily used in presence of 40% (v/v) methanol, ethanol and acetone and is selective for copper over a large number of cations with slight interference from Na(+) and Co(2+) if present at a level 1.5x10(-5) and 6.5x10(-5) M, respectively. It works well over a period of 6 months and can also be used as indicator electrode for the end point determination in the potentiometric titration of Cu(2+) against EDTA as well as in the determination of Cu(2+) in real samples.  相似文献   

17.
Endo M  Abe S  Deguchi Y  Yotsuyanagi T 《Talanta》1998,47(2):349-353
A highly sensitive and simple visual autocatalytic method has been developed for the determination of trace cobalt. The cobalt ion released by the oxidative decomposition of inert bis[2-(5-bromo-2-pyridylazo)-5-(N-propyl-N-sulfopropyl-amino-phenolato] cobaltate (Co(III)-5-Br-PAPS) with peroxomonosulfate acts as a catalyst for the oxidative degradation of the complex. Thus a definite time lapse of degradation is observed by the sudden disappearance of colored Co(III) complexes. The degradation time varies inversely with the logarithm of the initial concentration of cobalt(II). The determination range of cobalt(II) was from 3x10(-9) to 2x10(-7) M in the presence of 5x10(-6) M of 5-Br-PAPS. The relative standard deviation of the spot size method (10 mul) was 3.5% at 1x10(-7) M cobalt(II). This autocatalytic indicator reaction system has been successfully applied for the visual determination of urinary cobalt.  相似文献   

18.
A new, simple, sensitive, low cost and rapid potentiometric method for direct determination of ultra trace amounts of sodium dodecyl sulfate (SDS) with a new DS(-)-selective electrode is reported. The electrode was prepared by electropolymerization of aniline in acidified DS- ion on the surface of a Pt electrode. The cyclic voltammetry (CV) was used for electropolymerization of polyaniline (PA) in the potential range of -200 to +1000 mV vs. Ag/AgCl. This sensor showed a Nernstian behavior (59.0 +/- 2.3 mV/decade) over a very wide linear range (1.0 x 10(-9)-3.0 x 10(-6) M) with a detection limit of 1.0 x 10(-9) M. The response time of the electrode was 15 s for 1.0 x 10(-7) M of analyte; the electrode can be used for 4 weeks without any major deviation. This electrode can be used in the pH range of 3.5-9.8. The selectivity of electrode to DS- over some organic, inorganic and anionic surfactants was investigated with the fixed primary ion method. The results show that the electrode is highly selective to DS- ion over other ions. The proposed electrode was applied to the determination of DS- in real samples.  相似文献   

19.
A new PVC-membrane electrode for Co2+ ions based on N,N′-di(thiazol-2-yl)formimidamide (TF) as membrane carrier has been developed. The electrode resulted in Nernstian response (29.5?±?0.4?mV decade?1) for Co2+ ion over a wide concentration range (2.5?×?10?7 ?1.0?×?10?1?M) with a detection limit of 6.1?×?10?8?M. The sensor has a response time of about 10?s, and can be used for at least 2 months without observing any deviation from the Nernstain response. The electrode revealed good selectivity towards cobalt(II) ion over a wide variety of alkali, alkaline earth, transition, and heavy metal ions and could be used in the pH range 2.0–7.0. The electrode was used for determination of Co2+ in real samples.  相似文献   

20.
A PVC membrane electrode for lead ions based on phenyl disulfide as the membrane carrier was developed. The electrode exhibits a good Nernstian slope of 29.3 +/- 0.7 mV/decade and a linear range of 2.0 x 10(-6)-1.0 x 10(-2) M for Pb(NO3)2. The limit of detection is 1.2 x 10(-6) M. It has a response time of 45 s and can be used for at least fifty days without any divergence in potential. The proposed membrane sensor revealed high selectivity for Pb2+ over a wide variety of other metal ions and could be used in the pH range of 3.5-6.3. The electrode was used as an indicator electrode in potentiometric titration of lead ions.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号