首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
In this work, we demonstrate a two-layer microfluidic system capable of spatially selective delivery of drugs and other reagents under low shear stress. Loading occurs by hydrodynamically focusing a reagent stream over a particular region of the cell culture. The system consisted of a cell culture chamber and fluid flow channel, which were located in different layers to reduce shear stress on cells. Cells in the center of the culture chamber were exposed to parallel streams of laminar flow, which allowed fast changes to be made to the cellular environment. The shear force was reduced to 2.7 dyn cm−2 in the two-layer device (vs. 6.0 dyn cm−2 in a one-layer device). Cells in the side of the culture chamber were exposed to the side streams of buffer; the shear force was further reduced to a greater extent since the sides of the culture chamber were separated from the main fluid path. The channel shape and flow rate of the multiple streams were optimized for spatially controlled reagent delivery. The boundaries between streams were well controlled at a flow rate of 0.1 mL h−1, which was optimized for all streams. We demonstrated multi-reagent delivery to different regions of the same culture well, as well as selective treatment of cancer cells with a built in control group in the same well. In the case of apoptosis induction using staurosporine, 10% of cells remained viable after 24 h of exposure. Cells in the same chamber, but not exposed to staurosporine, had a viability of 90%. This chip allows dynamic observation of cellular behavior immediately after drug delivery, as well as long-term drug treatment with the benefit of large cell numbers, device simplicity, and low shear stress.  相似文献   

2.
The culture of cells in a microbioreactor can be highly beneficial for cell biology studies and tissue engineering applications. The present work provides new insights into the relationship between cell growth, cell morphology, perfusion rate, and design parameters in microchannel bioreactors. We demonstrate the long-term culture of mammalian (human foreskin fibroblasts, HFF) cells in a microbioreactor under constant perfusion in a straightforward simple manner. A perfusion system was used to culture human cells for more than two weeks in a plain microchannel (130 microm x 1 mm x 2 cm). At static conditions and at high flow rates (>0.3 ml h(-1)), the cells did not grow in the microchannel for more than a few days. For low flow rates (<0.2 ml h(-1)), the cells grew well and a confluent layer was obtained. We show that the culture of cells in microchannels under perfusion, even at low rates, affects cell growth kinetics as well as cell morphology. The oxygen level in the microchannel was evaluated using a mass transport model and the maximum cell density measured in the microchannel at steady state. The maximum shear stress, which corresponds to the maximum flow rate used for long term culture, was 20 mPa, which is significantly lower than the shear stress cells may endure under physiological conditions. The effect of channel size and cell type on long term cell culture were also examined and were found to be significant. The presented results demonstrate the importance of understanding the relationship between design parameters and cell behavior in microscale culture system, which vary from physiological and traditional culture conditions.  相似文献   

3.
Kim L  Toh YC  Voldman J  Yu H 《Lab on a chip》2007,7(6):681-694
Culturing cells at microscales allows control over microenvironmental cues, such as cell-cell and cell-matrix interactions; the potential to scale experiments; the use of small culture volumes; and the ability to integrate with microsystem technologies for on-chip experimentation. Microfluidic perfusion culture in particular allows controlled delivery and removal of soluble biochemical molecules in the extracellular microenvironment, and controlled application of mechanical forces exerted via fluid flow. There are many challenges to designing and operating a robust microfluidic perfusion culture system for routine culture of adherent mammalian cells. The current literature on microfluidic perfusion culture treats microfluidic design, device fabrication, cell culture, and micro-assays independently. Here we systematically present and discuss important design considerations in the context of the entire microfluidic perfusion culture system. These design considerations include the choice of materials, culture configurations, microfluidic network fabrication and micro-assays. We also present technical issues such as sterilization; seeding cells in both 2D and 3D configurations; and operating the system under optimized mass transport and shear stress conditions, free of air-bubbles. The integrative and systematic treatment of the microfluidic system design and fabrication, cell culture, and micro-assays provides novices with an effective starting point to build and operate a robust microfludic perfusion culture system for various applications.  相似文献   

4.
Kim L  Vahey MD  Lee HY  Voldman J 《Lab on a chip》2006,6(3):394-406
We present a microfluidic device for culturing adherent cells over a logarithmic range of flow rates. The device sets flow rates through four separate cell-culture chambers using syringe-driven flow and a network of fluidic resistances. The design is easy to fabricate with no on-chip valves and is scalable both in the number of culture chambers as well as in the range of applied flow rates. Using particle velocimetry, we have characterized the flow-rate range. We have also demonstrated an extension of the design that combines the logarithmic flow-rate functionality with a logarithmic concentration gradient across the array. Using fluorescence measurements we have verified that a logarithmic concentration gradient was established in the extended device. Compared with static cell culture, both devices enable greater control over the soluble microenvironment by controlling the transport of molecules to and away from the cells. This approach is particularly relevant for cell types such as embryonic stem cells (ESCs) which are especially sensitive to the microenvironment. We have demonstrated for the first time culture of murine ESCs (mESCs) in continuous, logarithmically scaled perfusion for 4 days, with flow rates varying >300x across the array. Cells grown in the slowest flow rate did not proliferate, while colonies grown in higher flow rates exhibited healthy round morphology. We have also demonstrated logarithmically scaled continuous perfusion culture of 3T3 fibroblasts for 3 days, with proliferation at all flow rates except the slowest rate.  相似文献   

5.
We describe the development, validation, and application of a novel PDMS-based microfluidic device for imaging leukocyte interaction with a biological substrate at defined shear force employing a parallel plate geometry that optimizes experimental throughput while decreasing reagent consumption. The device is vacuum bonded above a standard 6-well tissue culture plate that accommodates a monolayer of endothelial cells, thereby providing a channel to directly observe the kinetics of leukocyte adhesion under defined shear flow. Computational fluid dynamics (CFD) was applied to model the shear stress and the trajectory of leukocytes within the flow channels at a micron length scale. In order to test this model, neutrophil capture, rolling, and deceleration to arrest as a function of time and position was imaged in the transparent channels. Neutrophil recruitment to the substrate proved to be highly sensitive to disturbances in flow streamlines, which enhanced the rate of neutrophil-surface collisions at the entrance to the channels. Downstream from these disturbances, the relationship between receptor mediated deceleration of rolling neutrophils and dose response of stimulation by the chemokine IL-8 was found to provide a functional readout of integrin activation. This microfluidic technique allows detailed kinetic studies of cell adhesion and reveals neutrophil activation within seconds to chemotactic molecules at concentrations in the picoMolar range.  相似文献   

6.
Das T  Maiti TK  Chakraborty S 《Lab on a chip》2008,8(8):1308-1318
We develop here a microfabrication compatible force measurement technique termed as ultrasoft polydimethylsiloxane-based traction force microscopy (UPTFM). This technique is devised for mapping the cellular traction forces imparted on the adhering substrate, so as to depict the physiological state of the cells surviving in the micro-confinement. We subsequently integrate the technique with a microfluidic platform for evaluating different states of stress in adherent mouse skin fibroblast L929 cells. Utilizing this technique, we monitor the spatio-temporal evolution of cellular traction forces for static incubation periods with no media replenishment as well as for dynamic flow conditions that inherently induce cell deformation and detachment. While the studies conducted on a quiescent fluid medium enable us to obtain an optimal static cell incubation period, those executed under dynamic flow conditions provide us with the minuscule details of the cellular response, deformation and detachment processes. We elucidate the correlation between shear activated cytosolic calcium ion release profile and the local traction forces as an attempt to apply UPTFM in the domain of functional biological purposes. Pertinently, we map the centroidal displacement and the maximum traction stress in characterizing the critical shear rate conditions for the onset of the cell peeling-off process, and demonstrate their contrasting features in comparison to the vesicle lift off processes in a shear flow. Theoretically, these deviations can only be explained by taking physiologically relevant cell adhesion models into consideration, which, while retaining the intrinsic simplicity, are able to reproduce the key experimental outcomes at least with qualitative agreement. We execute further theoretical investigations with variable magnitudes of membrane stiffness, viscosity and adhesion strength, so as to come up with interesting biophysical confluences.  相似文献   

7.
Although it is still not clear whether migratory trophoblasts reach the spiral arteries by migration within blood vessels against blood flow or by a mechanism of directional cell division/proliferation, this process involves the attachment and adhesion of trophoblasts to endothelial cells lining the blood vessel walls. This raises the possibility that the cell–cell contact with endothelial cells may regulate trophoblast cell adhesion behaviors according to the surrounding flow condition. To test this, the adhesion forces of early gestation human trophoblast cells (TCs) cultured on glass slides coated with type I rat collagen or cultured with human umbilical vein endothelial cells (HUVECs) were measured quantitatively using a micropipette aspiration technique. Then, the resistance of TCs co-cultured with HUVECs to flow-induced shear stress was assessed with a flow chamber technique. The results showed that the adhesion force of TCs to glass slides coated with collagen was positively correlated with the concentration of collagen. By contact with endothelial cells, the adhesion force and the resistance to shear stress for the TCs were significantly enhanced. The interdiction of integrin β1 interaction remarkably reduced the adhesion forces of TCs to endothelial cells, hence their resistance to shear stress. The results therefore suggest that the contacts of TCs with endothelial cells enhance the adhesion forces of human TCs, partially by regulating with the integrin β1 according to the flow condition (i.e., the shear stress) in such a way to prevent the TCs from being carried downstream by flowing blood.  相似文献   

8.
Lee JM  Kim JE  Kang E  Lee SH  Chung BG 《Electrophoresis》2011,32(22):3133-3137
We developed an integrated microfluidic culture device to regulate embryonic stem (ES) cell fate. The integrated microfluidic culture device consists of an air control channel and a fluidic channel with 4×4 micropillar arrays. We hypothesized that the microscale posts within the micropillar arrays would enable the control of uniform cell docking and shear stress profiles. We demonstrated that ES cells cultured for 6 days in the integrated microfluidic culture device differentiated into endothelial cells. Therefore, our integrated microfluidic culture device is a potentially powerful tool for directing ES cell fate.  相似文献   

9.
Dynamic single cell culture array   总被引:2,自引:0,他引:2  
Di Carlo D  Wu LY  Lee LP 《Lab on a chip》2006,6(11):1445-1449
It is important to quantify the distribution of behavior amongst a population of individual cells to reach a more complete quantitative understanding of cellular processes. Improved high-throughput analysis of single cell behavior requires uniform conditions for individual cells with controllable cell-cell interactions, including diffusible and contact elements. Uniform cell arrays for static culture of adherent cells have previously been constructed using protein micropatterning techniques but lack the ability to control diffusible secretions. Here we present a microfluidic-based dynamic single cell culture array that allows both arrayed culture of individual adherent cells and dynamic control of fluid perfusion with uniform environments for individual cells. In our device no surface modification is required and cell loading is done in less than 30 seconds. The device consists of arrays of physical U-shaped hydrodynamic trapping structures with geometries that are biased to trap only single cells. HeLa cells were shown to adhere at a similar rate in the trapping array as on a control glass substrate. Additionally, rates of cell death and division were comparable to the control experiment. Approximately 100 individual isolated cells were observed growing and adhering in a field of view spanning approximately 1 mm(2) with greater than 85% of cells maintained within the primary trapping site after 24 hours. Also, greater than 90% of cells were adherent and only 5% had undergone apoptosis after 24 hours of perfusion culture within the trapping array. We anticipate uses in single cell analysis of drug toxicity with physiologically relevant perfused dosages as well as investigation of cell signaling pathways and systems biology.  相似文献   

10.
A simple photometric method for estimating viable cell number in culture is described. When cultured cells are allowed to internalize 0.005–0.01% neutral red for 1 h, the amount of accumulated dye is directly proportional to cell number. The linear relationship holds for adherent and suspended cell lines. Thus, dye content reflects cell number. Since dye content is easily measured by instruments that photometrically scan microtiter trays, proliferative and survival (cytotoxic) responses can be easily quantitated.  相似文献   

11.
We present a method that allows patterning cells and shear flow conditions for endothelial cell based assays. This method is novel in combining (1) cell culture on the surface of a substrate both topographically and chemically patterned; (2) multi-shear flow assays after covering the cell substrate with a microfluidic cover plate containing microchannels of different channel widths, and (3) conventional immunostaining assays after removal of the cover plate. This method has the advantage of performing cell cultures and immunoassays in standard cell biology environments with open access, facilitating the formation of confluent cell layers and the observation of cell responses to shear-flow and drug stimulations. To obtain multi-shear stress conditions, a single channel with stepwise increasing channel widths was patterned on the surfaces of both the substrate and the microfluidic cover plate. As results, we observed excellent viability of endothelial cells in the whole range of applied shear stresses (0-25 dyn cm(-2)) and shear stress dependent cytoskeleton remoulding, activation of von Willebrand factor (vWF), and re-organisation of angiogenesis factors such as tetra peptide acetyl-Ser-Asp-Lys-Pro (AcSDKP) of endothelial cells. To validate this approach for drug analysis, we also studied drug effects under shear stress conditions. Our results indicate that the drug effect of combretastatin A-4, an anti-tumour vascular targeting drug, could be significantly enhanced under shear flow conditions.  相似文献   

12.
Endothelial cell polarization and chemotaxis in a microfluidic device   总被引:2,自引:0,他引:2  
Shamloo A  Ma N  Poo MM  Sohn LL  Heilshorn SC 《Lab on a chip》2008,8(8):1292-1299
The directed migration of endothelial cells is an early and critical step in angiogenesis, or new blood vessel formation. In this study, the polarization and chemotaxis of human umbilical vein endothelial cells (HUVEC) in response to quantified gradients of vascular endothelial growth factor (VEGF) were examined. To accomplish this, a microfluidic device was designed and fabricated to generate stable concentration gradients of biomolecules in a cell culture chamber while minimizing the fluid shear stress experienced by the cells. Finite element simulation of the device geometry produced excellent agreement with the observed VEGF concentration distribution, which was found to be stable across multiple hours. This device is expected to have wide applicability in the study of shear-sensitive cells such as HUVEC and non-adherent cell types as well as in the study of migration through three-dimensional matrices. HUVEC were observed to chemotax towards higher VEGF concentrations across the entire range of concentrations studied (18-32 ng mL(-1)) when the concentration gradient was 14 ng mL(-1) mm(-1). In contrast, shallow gradients (2 ng mL(-1) mm(-1)) across the same concentration range were unable to induce HUVEC chemotaxis. Furthermore, while all HUVEC exposed to elevated VEGF levels (both in steep and shallow gradients) displayed an increased number of filopodia, only chemotaxing HUVEC displayed an asymmetric distribution of filopodia, with enhanced numbers of protrusions present along the leading edge. These results suggest a two-part requirement to induce VEGF chemotaxis: the VEGF absolute concentration enhances the total number of filopodia extended while the VEGF gradient steepness induces filopodia localization, cell polarization, and subsequent directed migration.  相似文献   

13.
Here we describe a non-traditional method to identify cancerous human cervical epithelial cells in a culture dish based on physical adhesion between silica beads and cells. It is a simple optical fluorescence-based technique which detects the relative difference in the amount of fluorescent silica beads physically adherent to surfaces of cancerous and normal cervical cells. The method utilizes the centripetal force gradient that occurs in a rotating culture dish. Due to the variation in the balance between adhesion and centripetal forces, cancerous and normal cells demonstrate clearly distinctive distributions of the fluorescent particles adherent to the cell surface over the culture dish. The method demonstrates higher adhesion of silica particles to normal cells compared to cancerous cells. The difference in adhesion was initially observed by atomic force microscopy (AFM). The AFM data were used to design the parameters of the rotational dish experiment. The optical method that we describe is much faster and technically simpler than AFM. This work provides proof of the concept that physical interactions can be used to accurately discriminate normal and cancer cells.  相似文献   

14.
15.
The capture of circulating tumor cells (CTCs) from cancer patient blood enables early clinical assessment as well as genetic and pharmacological evaluation of cancer and metastasis. Although there have been many microfluidic immunocapture and electrokinetic techniques developed for isolating rare cancer cells, these techniques are often limited by a capture performance tradeoff between high efficiency and high purity. We present the characterization of shear‐dependent cancer cell capture in a novel hybrid DEP–immunocapture system consisting of interdigitated electrodes fabricated in a Hele‐Shaw flow cell that was functionalized with a monoclonal antibody, J591, which is highly specific to prostate‐specific membrane antigen expressing prostate cancer cells. We measured the positive and negative DEP response of a prostate cancer cell line, LNCaP, as a function of applied electric field frequency, and showed that DEP can control capture performance by promoting or preventing cell interactions with immunocapture surfaces, depending on the sign and magnitude of the applied DEP force, as well as on the local shear stress experienced by cells flowing in the device. This work demonstrates that DEP and immunocapture techniques can work synergistically to improve cell capture performance, and it will aid in the design of future hybrid DEP–immunocapture systems for high‐efficiency CTC capture with enhanced purity.  相似文献   

16.
Kim J  Taylor D  Agrawal N  Wang H  Kim H  Han A  Rege K  Jayaraman A 《Lab on a chip》2012,12(10):1813-1822
We describe the development of a fully automatic and programmable microfluidic cell culture array that integrates on-chip generation of drug concentrations and pair-wise combinations with parallel culture of cells for drug candidate screening applications. The device has 64 individually addressable cell culture chambers in which cells can be cultured and exposed either sequentially or simultaneously to 64 pair-wise concentration combinations of two drugs. For sequential exposure, a simple microfluidic diffusive mixer is used to generate different concentrations of drugs from two inputs. For generation of 64 pair-wise combinations from two drug inputs, a novel time dependent variable concentration scheme is used in conjunction with the simple diffusive mixer to generate the desired combinations without the need for complex multi-layer structures or continuous medium perfusion. The generation of drug combinations and exposure to specific cell culture chambers are controlled using a LabVIEW interface capable of automatically running a multi-day drug screening experiment. Our cell array does not require continuous perfusion for keeping cells exposed to concentration gradients, minimizing the amount of drug used per experiment, and cells cultured in the chamber are not exposed to significant shear stress continuously. The utility of this platform is demonstrated for inducing loss of viability of PC3 prostate cancer cells using combinations of either doxorubicin or mitoxantrone with TRAIL (TNF-alpha Related Apoptosis Inducing Ligand) either in a sequential or simultaneous format. Our results demonstrate that the device can capture the synergy between different sensitizer drugs and TRAIL and demonstrate the potential of the microfluidic cell array for screening and optimizing combinatorial drug treatments for cancer therapy.  相似文献   

17.
Nanotopographic control of cytoskeletal organization   总被引:1,自引:0,他引:1  
Growth of 3T3-L1 preadipocytes on a nanoscalar poly(ethylene terephthalate) (PET) surface produced an absence of the intracellular stress fibers characteristic of cell growth on "normal" planar surfaces. This phenomenon was consistently observed from time zero throughout 3 days of culture and was accompanied by changes in paxillin expression along with an approximately 50% decrease in the number of adherent cells in response to 500 dynes/cm(2) of shear stress. This suggests that the cytoskeleton in cells adherent to nanofibrillar surfaces does indeed form, but at a smaller, more difficult to observe scale. We propose a novel mechanism by which the growth and clustering of integrin-associated focal adhesions on surface nanofibrils regulates cytoskeletal development. The width of the extracellular matrix contacts is constrained by the width of the nanofibrils and the absence of any surface between them. The limited dimensions of these point contacts then constrain receptor polymerization and the associated aggregation of actin filaments. The existence of a topographic mechanism leading to growth-limited integrin clustering is hypothesized.  相似文献   

18.
Microfluidic devices have recently emerged as effective tools for cell separation compared to traditional techniques. These devices offer the advantages of small sample volumes, low cost, and high purity. Adhesion-based separation of cells from heterogeneous suspensions can be achieved by taking advantage of specific ligand-receptor interactions. The peptide sequences Arg-Glu-Asp-Val (REDV) and Val-Ala-Pro-Gly (VAPG) are known to bind preferentially to endothelial cells (ECs) and smooth muscle cells (SMCs), respectively. This article examines the roles of REDV and VAPG and fluid shear stress in achieving selective capture of ECs and SMCs in microfluidic devices. The adhesion of ECs in REDV-coated devices and SMCs in VAPG-coated devices increases significantly compared to that of the nontargeted cells with decreasing shear stress. Furthermore, the adhesion of these cells is shown to be independent of whether these cells flow through the devices as suspensions of only one cell type or as a heterogeneous suspension containing ECs, SMCs, and fibroblasts. Whereas the overall adhesion of cells in the devices is determined mainly by shear stress, the selectivity of adhesion depends on the type of peptide and on the device surface as well as on the shear stress.  相似文献   

19.
Crystallization under shear of many different polypropylenes has been studied using a fiber pull-out device. It appears that growth can be considerably enhanced by flow. The best correlation is obtained with weight average molecular weight. Modeling the flow pattern gives access to the mechanical parameters at the growth front (shear rate and shear stress) as well as to the total strain applied to the polymer. The residual strain can be calculated taking into account relaxation processes.  相似文献   

20.
We present a high aspect ratio microfluidic device for culturing cells inside an array of microchambers with continuous perfusion of medium. The device was designed to provide a potential tool for cost-effective and automated cell culture. The single unit of the array consists of a circular microfluidic chamber 40 microm in height surrounded by multiple narrow perfusion channels 2 microm in height. The high aspect ratio (approximately 20) between the microchamber and the perfusion channels offers advantages such as localization of the cells inside the microchamber as well as creating a uniform microenvironment for cell growth. Finite element methods were used to simulate flow profile and mass transfer of the device. Human carcinoma (HeLa) cells were cultured inside the device with continuous perfusion of medium at 37 degrees C and was grown to confluency. The microfluidic cell culture array could potentially offer an affordable platform for a wide range of applications in high throughput cell-based screening, bioinformatics, synthetic biology, quantitative cell biology, and systems biology.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号