首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
The application of unmodified silica gel (Super Micro Bead Silica Gel B-5, SMBSG B-5) as a cation-exchange stationary phase in ion chromatography with indirect photometric detection (IC-IPD) for the separation of common mono- and divalent cations (Li+, Na+, NH4+, K+, Mg2+ and Ca2+) was carried out using various aromatic monoamines [tyramine [4-(2-aminoethyl)phenol], benzylamine, phenylethylamine, 2-methylpyridine and 2,6-dimethylpyridine] as eluents. When using these amines as eluents, the peak resolution between these mono- and divalent cations was not quite satisfactory and the peak shapes of NH4+ and K+ were largely destroyed on the SMBSG B-5 silica gel column. Hence, the application of SMBSG B-5 silica gel calcinated at 200, 400, 600, 800 and 1000 degrees C for 5 h in the IC-IPD was carried out. The peak shapes of the monovalent cations were greatly improved with increasing calcination temperature and, as a result, symmetrical peaks of these mono- and divalent cations were obtained on the SMBSG B-5 silica gel calcinated at 1000 degrees C as the stationary phase. In contrast, the peak resolution between these mono- and divalent cations was not improved. Therefore, crown ethers [18-crown-6 (1,4,7,10,13,15-hexaoxacyclooctadecane), 15-crown-5 (1,4,7,10,13-pentaoxacyclopentadecane)] were added to the eluent for the complete separation of these mono- and divalent cations. Excellent simultaneous separation and highly sensitive detection at 275 nm were achieved in 25 min on a column (150x4.6 mm I.D.) packed with SMBSG B-5 silica gel calcinated at 1000 degrees C by elution with 0.75 mM tyramine-0.25 mM oxalic acid at pH 5.0 containing either 1.0 mM 18-crown-6 or 10 mM 15-crown-5.  相似文献   

2.
Monovalent cations (M+ = Na+, K+, Rb+, and NH4+) and 12-crown-4 were assembled to new supramolecular cation (SC+) structures of the M+(12-crown-4)n (n = 1 and 2), which were incorporated into the electrically conducting Ni(dmit)2 salts (dmit = 2-thioxo-1,3-dithiole-4,5-dithiolate). The Na+, K+, and Rb+ salts are isostructural with a stoichiometry of the M+(12-crown-4)2[Ni(dmit)2]4, while the NH4+ salt has a stoichiometry of NH4+(12-crown-4)[Ni(dmit)2]3(CH3CN)2. The electrical conductivities of the Na+, K+, Rb+, and NH4+ salts at room temperature are 7.87, 4.46, 0.78, and 0.14 S cm-1, respectively, with a semiconducting temperature dependence. The SC+ structures of the Na+, K+, and Rb+ salts have an ion-capturing sandwich-type cavity of M+(12-crown-4)2, in which the M+ ion is coordinated by eight oxygen atoms of the two 12-crown-4 molecules. On the other hand, the NH4+ ion is coordinated by four oxygen atoms of the 12-crown-4 molecule. Judging from the M(+)-O distances, thermal parameters of oxygen atoms, and vibration spectra, the thermal fluctuation of the Na+(12-crown-4)2 structure is larger than those of K+(12-crown-4)2 and Rb+(12-crown-4)2. The SC+ unit with the larger alkali metal cation gave a stress to the Ni(dmit)2 column, and the SC+ structure changed the pi-pi overlap mode and electrically conducting behavior.  相似文献   

3.
丁明玉  陈培榕 《分析化学》1998,26(4):425-427
发现以酒石酸和吡啶二甲酸等羧酸水溶液作淋洗剂时,钠,铵,钾,镁和钙等碱金属及碱土金属离子在ODS反相高效液相色谱柱上有明显的保留,而且相互之间能达到一定程度的分离。单独用分配或疏水作用等反相高效液相色谱的保留机理难以解释其保留行为。为此,作者提出了动态包固定相机理,即认为羧酸根阴离子因其疏水性在ODS固定相有保留,在固定相表面形成具有羧酸基阳离子交换树脂功能的动态包覆固定相。  相似文献   

4.
An ion chromatographic method has been developed for the determination of alkali (Li(+), Na(+), K(+)), alkaline earths (Ca(2+), Mg(2+), Ba(2+), Sr(2+)) and ammonium ion in waters. The usual difficulties encountered during traditional cation-exchange separations (incomplete resolution for Na(+) and NH(4) (+) present in disproportionate concentration ratios) have been overcome tuning the selectivity of the separation by the introduction of 18-crown-6 ether in the mobile phase using an IonPac CS12A (150x3 mm id) column. After a detailed study of the effect of mobile phase components on separation, a gradient elution from 26 mM methanesulphonic acid (MSA) with a step change at 9 min to 60 mM MSA (0.5 mM 18-crown-6) provided the required baseline separation for the eight selected analytes. The method developed provides the advantage of the determination, in the same analytical run, also of strontium and barium, which is usually performed by spectroscopic techniques. Within-day and between-day repeatability have been assessed, observing between-day RSD included between 0.3 and 1.8% for retention times and 0.6 and 7.2% for peak areas. The method has been finally tested for the analysis of water samples of different provenience (well, tanks, water system) and results compared with those obtained by the laboratory in charge of the control of drinking water for the city of Torino (Italy).  相似文献   

5.
Arai K  Mori M  Hironaga T  Itabashi H  Tanaka K 《色谱》2012,30(4):404-408
A combination of hydrophilic interaction chromatographic(HILIC) column and a weakly acidic cation-exchange resin(WCX) column was used for simultaneous separation of inorganic anions and cations by ion chromatography(IC).Firstly,the capability of HILIC column for the separation of analyte ions was evaluated under acidic eluent conditions.The columns used were SeQuant ZIC-HILIC(ZIC-HILIC) with a sulfobetaine-zwitterion stationary phase(ZIC-HILIC) and Acclaim HILIC-10 with a diol stationary phase(HILIC-10).When using tartaric acid as the eluent,the HILIC columns indicated strong retentions for anions,based on ion-pair interaction.Especially,HILIC-10 could strongly retain anions compared with ZIC-HILIC.The selectivity for analyte anions of HILIC-10 with 5 mmol/L tartaric acid eluent was in the order of I-> NO-3 > Br-> Cl-> H2PO-4.However,since HILIC-10 could not separate analyte cations,a WCX column(TSKgel Super IC-A/C) was connected after the HILIC column in series.The combination column system of HILIC and WCX columns could successfully separate ten ions(Na+,NH+4,K+,Mg2+,Ca2+,H2PO-4,Cl-,Br-,NO-3 and I-) with elution of 4 mmol/L tartaric acid plus 8 mmol/L 18-crown-6.The relative standard deviations(RSDs) of analyte ions by the system were in the ranges of 0.02%-0.05% in retention times and 0.18%-5.3% in peak areas through three-time successive injections.The limits of detection at signal-to-noise ratio of 3 were 0.24-0.30 μmol/L for the cations and 0.31-1.2 μmol/L for the anions.This system was applied for the simultaneous determination of the cations and the anions in a vegetable juice sample with satisfactory results.  相似文献   

6.
We introduced an approach to the ion chromatographic determination of common mono- and divalent cations including hydrogen ion and demonstrated the ability of a C30 column dynamically coated first with dodecylsulfate and then with 18-crown-6 ether to separate the cations by ion-exchange mechanism. Using an ethylenediamine solution containing a small concentration of 18-crown-6 ether and lithium dodecylsulfate at pH 6.2 as eluent, the cations were eluted in the order Li < Na+ < NH4+ < H+ < K+ < Mg2+ < Ca2+ with symmetrical peaks. The conductivity vs. concentration plots were linear about three orders of magnitude, from millimolar to micromolar; and the detection limits were all < 0.6 microM. Rainwater was analyzed directly using this ion chromatographic system with satisfactory results.  相似文献   

7.
Hydrogels containing benzo-18-crown-6 were used to modify microcantilevers for measurements of the concentration of Pb2+ in aqueous solutions. These microcantilevers undergo bending deflection upon exposure to solutions containing various Pb2+ concentrations as the result of a swelling of the hydrogels. It was found that a concentration of 10(-6) M Pb2+ can be detected using this technology. Other cations, such as Na+, have no effect on the deflection of this cantilever. The cation K+, which also complexes with benzo-18-crown-6, could interfere with Pb2+ detection, but only at high concentrations (> 10(-4) M).  相似文献   

8.
于泓 《分析化学》1998,26(1):89-92
研究了邻苯二甲酸、苯甲酸和对羟基苯甲酸3种芳香酸分别做淋洗液的单柱阳离子色谱法分离测定Li+、Na+、NH4+、K+、甲胺、乙胺和正丙胺7种物质。3种芳香酸做淋洗液均可将7种物质分离开,且分离结果差异不大。在淋洗液浓度相同的条件下,邻苯二甲酸做淋洗液测定的检出限较低。选择3.0 mmol/L邻苯二甲酸做淋洗液测得了上述7种物质的检出限和线性范围,并进行了叶面肥试样分析,7种物质的加标回收率在96.4%~98.6%之间。  相似文献   

9.
The effects of transport conditions and the structure of monoazacrownethers on their transport ability for alkali metal cations through a bulkliquid membrane are summarized and discussed based on transport dataobtained in our laboratories. To improve the transport ability,monoazacryptands have been prepared. A lipophilic derivative consisting oftwo 18-crown-6 rings and one 20-crown-6 ring can selectively transport K+from a mixture of Na+, K+, Mg2+, and Ca2+ under pH control.  相似文献   

10.
非抑制型离子色谱法测定碱金属、铵离子和烷基胺   总被引:3,自引:0,他引:3  
于泓  李萍 《色谱》2001,19(2):182-183
 采用非抑制型离子色谱法、以氨磺酸作流动相分离测定了Li+ 、Na+ 、NH+ 4、K+ 、甲胺、乙胺和正丙胺等 7种物质 ,研究了氨磺酸流动相浓度对溶质保留值的影响。结果发现 ,随着流动相浓度的增大 ,溶质保留值减小 ;适宜的流动相浓度为 4 0mmol/L。以 4 0mmol/L氨磺酸为流动相测得上述 7种物质的检出限及工作曲线的线性回归方程。方法应用于自来水试样的分析 ,结果良好。  相似文献   

11.
The coordination reaction of Na+, K+, Rb+ and Cs+ with benzo- 15-crown-5, 18-crown-6 and the newly synthesized cyclic polyethers 2, 3-benzo-8, 15-dimethyl-18-crown-6, 2, 3-benzo-8, 11, 15-trimethyl-18-crown-6 in methanol at 25`C has been studied by conductometric titration. The stability constants for the 1:1 coordination compounds were calculated. The marked selectivity of 18-crown-6 toward alkali metal ions was not found in its methyl derivatives. The induction effect of the benzene ring and methyl group on polyether ring reduced the stability of the coordination compounds. In methanol, the stability sequence of te compounds of alkali metal ions with 18-crown-6 was K+>Rb+>Cs+>Na+, that of its dimethyl derivative was K+>Rb+>Na+>Cs+ and that of its trimethyl derivative was K+>Na+>Rb+>Cs+, that is, the methyl substituent had a weaker influence on the stability of Na+ compound than on that of Rb+ or Cs+ compound. In the range of concentration studied, decrease in equivalent conductance is in agreement with the prediction on the basis of the structure of the complexes. The above results may give a clue for modifying the structure of a crown ether for specified selectivity.  相似文献   

12.
Ding MY  Tanaka K  Hu W  Hasebe K  Haddad PR 《The Analyst》2001,126(5):567-570
A non-suppressed conductivity detection ion chromatographic method using a weakly acidic cation-exchange column (Tosoh TSKgel OApak-A) was developed for the simultaneous separation and determination of common inorganic anions (Cl-, NO3- and SO4(2-)) and cations (Na+, NH4+, K+, Mg2+ and Ca2+). A satisfactory separation of these anions and cations on the weakly acidic cation-exchange column was achieved in 25 min by elution with a mixture of 1.6 mmol L-1 pyridine-2,6-dicarboxylic acid and 8.0 mmol L-1 18-crown-6 at flow rate of 1.0 mL min-1. On this weakly acidic cation-exchange resin, anions were retained by an ion-exclusion mechanism and cations by a cation-exchange mechanism. The linear range of the peak area calibration curves for all analytes were up to two orders of magnitude. The detection limits calculated at S/N = 3 ranged from 0.25 to 1.9 mumol L-1 for anions and cations. The ion-exclusion chromatography-cation-exchange chromatography method developed in this work was successfully applied to the simultaneous determination of major inorganic anions and cations in rainwater, tap water and snow water samples.  相似文献   

13.
The application of laboratory-made aluminium-adsorbing silica gel (Al-Silica) as a cation-exchange stationary phase to ion chromatography-indirect photometric detection (IC-IPD) for common mono- and divalent cations (Li+, Na+, NH+, K+, Mg2+ and Ca2+) was carried out by using protonated tyramine (4-aminoethylphenol) as eluent ion. When using 1.2 mM tyramine-0.2 mM oxalic acid at pH 4.5 as eluent, incomplete separation of the monovalent cations and complete separation of the divalent cations were achieved in 17 min. Then, the addition of crown ethers in the eluent was carried out for the complete separation of the mono- and divalent cations. As a result, when using 1.2 mM tyramine--0.2 mM oxalic acid at pH 4.5 containing either 5 mM 15-crown-5 (1,4,7,10,13-pentaoxacyclopentadecane) or 0.5 mM and 18-crown-6 (1,4,7,10,13,16-hexaoxacyclooctadecane) as eluent, excellently simultaneous separation of these cations was achieved in 21 min. The proposed IC-IPD was successfully applied to the determination of major cations in natural water samples.  相似文献   

14.
It was found that common cations (Na+, NH4+, K+, Mg2+ and Ca2+) could be strongly retained on an ODS stationary phase when aqueous solutions of carboxylic acids were used as eluents. The chromatographic conditions used in this work were the same as in common cation-exchange chromatography on a cation-exchange resin and the retention behavior of the above-mentioned cations on the ODS column was quite similar to that on a cation-exchange column. The retention behavior and mechanism have been investigated using a number of carboxylic acids as eluents. The retention mechanism of the cations in these experiments was considered to be a dynamic coating ion-exchange mechanism. The carboxylic acids in the mobile phase were coated onto the surface of the ODS stationary phase and formed a dynamic carboxylic acid functional layer which could act like the functional group layer of a carboxylic group cation exchanger.  相似文献   

15.
双冠醚化合物对某些金属离子比单冠醚具有更好的络合性能和选择性,它们合成、应用研究越来越受到人们的重视,本工作采用2,6-二羟甲基对甲氧基苯酚为缩合剂与芳香族冠醚缩聚,得到一系列具有双冠醚结构特征的新酚醛型聚苯并冠醚(简称聚冠醚),聚冠醚合成容易,并呈现了比相应单冠醚更优越的络合萃取能力和富集效率。  相似文献   

16.
Yokoyama Y  Sawaguchi N  Sato H 《The Analyst》2001,126(7):989-994
A successive non-suppressed ion chromatography (IC) system for the determination of common cations (Na+, K+, Mg2+, Ca2+) and anions (Cl-, Br-, NO3-, SO4(2-)) was developed, using two separation columns and a single eluent. 5-Sulfoisophthalic acid eluent was very suitable for such separations with a commercially available cation-exchange column for the mono- and di-valent cations and with an ODS column coated with cetyltrimethylammonium for the anions. Both cations and anions were detected with conductimetrically high sensitivity without any suppressor. After injecting an aliquot of sample solution, the solvent front from the cation-exchange column, including most of the anionic species, was firstly accumulated into the additional 2 ml accumulation loop for 60 s, while the cation IC was performed. Subsequently, the accumulated fraction was introduced into the anion-exchange column and chromatographed. Relative standard deviations (RSDs) of retention times and conductimetric area responses for common cations were within 6% and within 4%, respectively. The linear relationships between molar concentration and detector response ranged from 0.01 to 1.00 mM with r2 of 0.9994 for Na+, 0.9992 for K+, 0.9993 for Mg2+, and 0.9988 for Ca2+. The successive anion IC through the accumulating process was also quantitative, with 95% recovery or over for each analyte. The linear ranges were between 0.01 and 1.00 mM with r2 of 0.9996 for Cl-, 0.9997 for Br-, 0.9993 for NO3-, and 0.9984 for SO4(2-). The method was applied to the determination of common cations and anions in several mineral waters and a hot spring water.  相似文献   

17.
Influence of acidic eluent on retention behaviors of common anions and cations by ion-exclusion/cation-exchange chromatography (ion-exclusion/CEC) were investigated on a weakly acidic cation-exchange resin in the H(+)-form with conductivity. Sensitivities of analyte ions, especially weak acid anions (F(-) and HCOO(-)), were affected with degree of background conductivity level with pK(a1) (first dissociation constant) of acid in eluent. The retention behaviors of anions and cations were related to that of elution dip induced after eluting acid to separation column and injecting analyte sample. These results were largely dependent on the natures of acid as eluent. Through this study, succinic acid as the eluent was suitable for simultaneous separation of strong acid anions (SO(4)(2-), Cl(-), NO(3)(-) and I(-)), weak acid anions (F(-), HCOO(-) and CH(3)COO(-)), and cations (Na(+), K(+), NH(4)(+), Mg(2+) and Ca(2+)). The separation was achieved in 20 min under the optimum eluent condition, 20 mM succinic acid/2 mM 18-crown-6. Detection limits at S/N=3 ranged from 0.10 to 0.51 microM for strong acid anions, 0.20 to 5.04 microM for weak acid anions and 0.75 to 1.72 microM for cations. The relative standard deviations of peak areas in the repeated chromatographic runs (n=10) were in the range of 1.1-2.9% for anions and 1.8-4.5% for cations. This method was successfully applied to hot spring water containing strong acid anions, weak acid anions and cations, with satisfactory results.  相似文献   

18.
A monolithic ODS-silica gel column modified by saturating it with lithium dodecylsulfate (Li-DS) was used to demonstrate the high-speed separation of H+ from other mono- and divalent cations, such as Na+, NH4+, K+, Mg2+ and Ca2+ using ion chromatography (IC). Using a 5 mM EDTA-2K solution containing 0.10 mM Li-DS (pH 4.80) as eluent, H+ was eluted with a sharp and symmetrical peak within 1.0 min before other cations at a flow-rate of 1.5 ml min(-1). The rapid elution of H+ and its conductimetric detection could be attributed to the presence of EDTA (HY2-), which can convert H+ ions as anions. i.e. H(+) + H2Y(2-) --> H3Y(-). The acidity of rainwater and deionized water samples was determined using this IC system with satisfactory results.  相似文献   

19.
研究了非抑制型阳离子交换色谱中色谱柱温度(25~50℃)对碱金属离子(Li+、Na+、K+、Rb+)和碱土金属离子(Mg2+、Ca2+、Sr2+)以及NH4+保留的影响。在Shim-pack IC-C1磺酸型阳离子交换柱上,以硝酸为流动相分离碱金属离子,以乙二胺或乙二胺-草酸(柠檬酸)为流动相分离碱土金属离子,随着色谱柱温度的升高,碱金属和碱土金属离子的保留时间均增长,其范特霍夫曲线具有良好的线性关系,斜率为负值,表明在此条件下碱金属和碱土金属离子的保留为吸热过程。在Shim-pack IC-SC1羧酸型阳离子交换柱上,以硫酸为流动相同时分离碱金属和碱土金属离子,随着色谱柱温度的升高,Mg2+、Ca2+的保留时间增长,而K+、Rb+的保留时间缩短,Li+、Na+、NH4+的保留时间基本不变。在此条件下,Mg2+、Ca2+、K+和Rb+的范特霍夫曲线具有良好的线性关系,其中Mg2+和Ca2+的曲线斜率为负值,K+和Rb+的曲线斜率为正值,表明Mg2+和Ca2+的保留表现为吸热过程,K+和Rb+的保留表现为放热过程。研究表明在不同固定相和流动相条件下,色谱柱温度对碱金属和碱土金属离子保留行为的影响不同。  相似文献   

20.
Ion-exclusion/cation-exchange chromatography with an eluent containing the bile salt-type zwitterionic surfactant CHAPS was performed in order to evaluate variations in anion (SO(4)(2-), NO(3)(-), and SCN(-)) and cation (Na(+), K(+), NH(4)(+), Mg(2+), and Ca(2+)) concentrations in human saliva. CHAPS prevents the adsorption of proteins to the stationary phase, i.e., weakly acidic cation-exchange resin, since it aggregates proteins without denaturing them. Addition of 1mM CHAPS to the eluent comprising 6mM tartaric acid and 7 mM 18-crown-6 yielded reproducible separations of anions and cations in protein-containing saliva. The resolutions of anions and cations were not significantly affected by the addition of CHAPS to the eluent. The concentrations of Na(+) and K(+) varied before and after meals; or that of SCN(-), upon smoking. The relative standard deviations of peak areas ranged from 0.3 to 5.1% in 1 day (n=20) and from 1.4 to 5.8% over 6 days (n=6).  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号