首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Fast isotopic separation of 10B and 11B boric acid by CZE was demonstrated. The BGE contained 25 mM phenylalanine and 5 mM putrescine (рН 8.95). The running conditions were +25 kV at 20°C with indirect photometric detection at 210 nm. Baseline separation was achieved in less than 9 min. RSD of migration times and corrected peak areas were less than 0.5 and 3%, respectively (n = 5). Linearity was demonstrated in the range 0.2–2 mM for 11B and 0.2–0.5 mM for 10B.  相似文献   

2.
A micellar electrokinetic capillary chromatography (MEKC) method with ultraviolet visible (UV) detection was used for the determination of 1,7-naphthalenediol, 2,3-naphthalenediol, 1,5-naphthalenediol, and 2,7-naphthalenediol in cosmetics. The current method for their determination in various cosmetics is high-performance liquid chromatography (HPLC). Separation conditions affecting the MEKC method were optimized as 20 mM Na2B4O7–50mM SDS, pH 9.8, with 22 kV applied voltage and UV detection at 230 nm. Under optimal conditions, electrophoretic analysis was completed in less than 6 min, with limit of detection (LOD) of 0.070–0.19 μg/mL and limit of quantitation (LOQ) of 0.23–0.63 μg/mL. A good linear relationship (r2 > 0.99) was obtained at the range of 0.75–20 μg/mL. Recoveries for the four naphthalenediols in lotion, loose powder, and sun cream are between 91.2–107.2% with relative standard deviation (RSD) less than 4.04%. The method has been successfully applied to the determination of the four naphthalenediols in different kinds of cosmetics. A comparison with HPLC-UV method was also carried out according to the National Standards of the People's Republic of China. The results obtained by MEKC and HPLC methods are comparable, but the proposed MEKC method can help us obtain a much shorter detection time and low cost.  相似文献   

3.
《Analytical letters》2012,45(6):1011-1024
Abstract

Amperometric bipelectrodes based on carbon paste modified with L-lactate oxidase and mediators are described which are sensitive to L-lactaie. Several ferrocenes and phenoxazine derivatives as mediators are evaluated, with Meldola blue exhibiting the best results.

With ferrocene derivatives the bioelectrodes were operated at potential of 0.2-0.4 V (vs SCE). The apparent Michaelis constants for the calibration curves of the bioelectrodes are different depending on the chosen mediator and varied in the range from 0.9 to 3.6 mM L-lactate. The pH optimum in the case of the 1,1′-dimethylferrocene bioelectrode was 9.3 and the limiting sensitivity was determined to be 31 μA/mM cm?2. Covered by a Nation membrane, the electrode sensitivity was in the range of 3.2-4.4 μA/mM cm?2 at pH 7.0 and the calibration range was linear up to 2-2.5 mM L-lactate.

The bioelectrode based on Meldola blue mediated electron transfer at potentials between 0.05-0.25 V. The Km(app) was 17.0 and 18.2 mM at 0.1 and 0.05 V, respectively. The pH optimum of the bioelectrodes was 7.9 and limiting sensitivity - 164μA/mM cm?2.

At normal physiological level of ascorbic acid (50 μM) in blood the response of the Meldoia blue based sensors was 5.3 % at 0.1 V, whereas that of the 1,1′-dimethylferrocene bioelectrode was 83 % at 0.25 V in comparison to the response observed with physiological levels of L-lactate (2 mM).  相似文献   

4.
Separation of lithium and magnesium isotopes by cation exchange elution chromatography was carried out with a synthesized 1,13,16-trioxa-4,7,10-triazacyclooctadecane (N3O3)-4,7,10-trimerrifield peptide resin and with a 2-aminomethyl-18-crown-6 (AM18C6) bonded Merrifield peptide resin. The resins have a capacity of 0.1 and 2.3 meq/g dry resin. A single stage separation factor of lithium isotopes, 1.018 was obtained by the Glueckauf theory from the elution curve and isotopic assays. The heavier isotope, 7Li was concentrated in the resin phase, while the lighter isotope, 6Li concentrated in the solution phase. On the other hand, the heavier isotopes of magnesium were concentrated in the solution phase, while the lighter isotopes were concentrated in the resin phase. The separation factors of 24Mg-25Mg, 24Mg-26Mg, and 25Mg-26Mg isotope pair fractionations were 1.012, 1.022, and 1.012, respectively.  相似文献   

5.
The coincident measurement of both nuclear products at their complementary angles was used to determine6Li by the reactions6Li(d, α)4He and6Li(p, α)3He, and7Li by the reaction7Li(p, α)4He. Elemental lithium was determined in natural samples or samples of known isotopic composition. Isotopic analyses could be carried out over the entire range from 0 to 100 atom% with a relative standard deviation of about 4%. The CMCP technique is highly specific and effectively eliminates interference and background.  相似文献   

6.
The aim of this study was to study the stress degradation of granisetron and analysis of the drug in the presence of its degradation products. Forced degradation studies were conducted on bulk sample using acidic, alkaline, oxidative, heat and photolytic conditions. Granisetron was relatively unstable under acidic, alkaline and oxidative conditions. Separation of granisetron and degradation products was achieved using a Nova‐Pak C8 column and acetonitrile‐KH2PO4 25 mM (75:25, v/v) as mobile phase with UV detection at 305 nm. The method was linear over the range of 0.2‐15 μg/mL granisetron (r2 > 0.999). The within‐day and between‐day precision values were also in the range of 0.5‐4%. The proposed method was successfully applied for quantitative determination of granisetron in tablets and in vitro dissolution studies.  相似文献   

7.
The ionic conductivity of γ-Li3BO3 is measured in wide intervals of temperatures and7Li to6Li ratios. It is found that the conductivity and activation energy vary nonmonotonically with variations in concentrations of the two isotopes; the concentration dependence of electroconductivity has a minimum, and that of the activation energy has a maximum at a7Li :6Li ratio of about 50 : 50 at. %; and the activation energy for conduction by6Li exceeds that by7Li  相似文献   

8.
Charged particle spectrometry was used to determine the isotopic concentration of lithium in lithium fluoride targets irradiated with a deuteron beam of 4.0 MeV. Alpha particles emitted by the6Li(d, α)4He and7Li(d, α)5He reactions were used as a measure of6Li and7Li, respectively. From the6Li/7Li α-count ratio the isotopic concentration of6Li was determined for isotopic concentrations over the range 7.42 (natural) to about 30 atom%6Li, with a relative standard deviation of±4.1%. Alpha particles from the19F(d, α)17O reaction could also be measured as an internal standard, extending the measurements from natural to 100 atom%6Li and giving a relative standard deviation of ±1.9%. The effect of target thickness on the accuracy of the determinations was investigated.  相似文献   

9.

A new method involving matrix solid-phase dispersion (MSPD) extraction and UPLC in conjunction with photodiode array detection was developed for the rapid and simple determination of Sudan dyes in chili powder. Separation of Sudan I, Sudan II, Sudan III, and Sudan IV was achieved within 2 min on the 1.7 μm Acquity UPLC BEH C18 column by using gradient elution with a mobile phase consisting of acetonitrile–water at a flow rate of 0.5 mL min−1. Optimization of MSPD extraction parameters, such as type of solid sorbent and elution solvent were carried out. Optimal conditions selected for MSPD extraction were 0.25 g of sample, 0.5 g of silica gel as solid sorbent, and 7 mL of acetonitrile–methanol (9:1, v/v) as eluting solvent. Limits of detection ranged between 0.25 and 0.30 mg kg−1 depending on the dye involved. All analytes provided average recoveries from spiked (at 1, 1.5, and 2 mg kg−1) chili powder samples ranging from 81 to 106%. The method was applied to the analysis of chili powder samples obtained from different countries.

  相似文献   

10.
Gold nanoparticles with pre-selected size in the range 5–40 nm were synthesized by γ-irradiation of Au3+ solution containing natural polysaccharide alginate as a stabilizer. The gold nanoparticles with controllable size were prepared by two approaches: (i) varying the concentration of Au3+ from 0.25 to 1 mM and alginate from 0.25% to 1% (w/v) and (ii) enlargement of seed particles with double size from 20 to 40 nm at [Au3+]/[Au0]=6. The obtained gold nanoparticles were characterized by UV–vis spectroscopy and transmission electron microscopy. The results indicated that γ-irradiation method is suitable for production of gold nanoparticles with controllable size and high purity.  相似文献   

11.
In this study, two complementary approaches, affinity capillary electrophoresis (ACE) and quantum mechanical density functional theory (DFT) calculations, have been employed for quantitative characterization and structure elucidation of the complex between hexaarylbenzene (HAB)‐based receptor R and lithium ion Li+. First, by means of ACE, the apparent binding constant of Li R + complex (K) in methanol was determined from the dependence of the effective electrophoretic mobilities of Li R + complex on the concentration of lithium ions in the 25 mM Tris/50 mM chloroacetate background electrolyte (BGE) using non‐linear regression analysis. Prior to regression analysis, the effective electrophoretic mobilities of the Li R + complex were corrected to reference temperature 25°C and constant ionic strength 25 mM. The apparent binding constant of the Li R + complex in the above methanolic BGE was evaluated as logK = 1.15±0.09. Second, the most probable structures of nonhydrated Li R + and hydrated Li R +·3H2O complexes were derived by DFT calculations. The optimized structure of the hydrated Li R +·3H2O complex was found to be more realistic than the nonhydrated Li R + complex because of the considerably higher binding energy of Li R +·3H2O complex (500.4 kJ/mol) as compared with Li R + complex (427.5 kJ/mol).  相似文献   

12.
《Electrophoresis》2017,38(24):3124-3129
The combination of capillaries with different internal diameters was used to accelerate the separation of enantiomers in capillary electrophoresis. Separation of R ,S‐1,1′‐binaphthalene‐2,2′‐diyl hydrogen phosphate using isopropyl derivative of cyclofructan 6 was studied as a model system. The best separation conditions included 500 mM sodium borate pH 9.5 with 60 mM concentration of the chiral selector. Separation lasted approx. 1.5 min using the combination of 50 and 100 μm id capillaries of 9.7 cm and 22.9 cm, respectively. It allowed approx. 12‐fold acceleration in comparison to the traditional long‐end separation mainly due to the higher electroosmotic flow generated in the connected capillaries.  相似文献   

13.

The present study describes the degradation of gemifloxacin mesylate under different International Conference on Harmonization prescribed stress conditions (hydrolysis, oxidation, dry and wet heat and photolysis) and application of a specific and selective stability-indicating reversed-phase liquid chromatography assay. Separation of drug and degradation products was successfully achieved on a HiQ-SiL C8 column using 10 mM potassium dihydrogen orthophosphate (pH adjusted to 3.0 with o-phosphoric acid)–acetonitrile (65:35, v/v) at a flow rate of 1 mL min−1 and detection at 273 nm.

  相似文献   

14.
A new method involving matrix solid-phase dispersion (MSPD) extraction and UPLC in conjunction with photodiode array detection was developed for the rapid and simple determination of Sudan dyes in chili powder. Separation of Sudan I, Sudan II, Sudan III, and Sudan IV was achieved within 2 min on the 1.7 μm Acquity UPLC BEH C18 column by using gradient elution with a mobile phase consisting of acetonitrile–water at a flow rate of 0.5 mL min?1. Optimization of MSPD extraction parameters, such as type of solid sorbent and elution solvent were carried out. Optimal conditions selected for MSPD extraction were 0.25 g of sample, 0.5 g of silica gel as solid sorbent, and 7 mL of acetonitrile–methanol (9:1, v/v) as eluting solvent. Limits of detection ranged between 0.25 and 0.30 mg kg?1 depending on the dye involved. All analytes provided average recoveries from spiked (at 1, 1.5, and 2 mg kg?1) chili powder samples ranging from 81 to 106%. The method was applied to the analysis of chili powder samples obtained from different countries.  相似文献   

15.
The 1D- and 2D-6Li, 6Li-INADEQUATE experiments are described as new tools for the detection of scalar coupled nonequivalent 6Li nuclei in organolithium clusters. Practical applications of these sequences are demonstrated for the 6Li-NMR spectra of (E)-1-lithio-2-(2-lithiophenyl)-1-phenylhex-1-ene ( 1 ) and (E)-2-lithio-1-(2-lithiophenyl)-1-phenylpent-1-ene ( 2 ), where signals due to dimers and monomers can be distinguished. The performance of the 2D-6Li, 6Li-INADEQUATE and the 6Li, 6Li-COSY-45-LR experiment are compared. The 6Li chemical shifts of 1 and 2 are discussed.  相似文献   

16.
Basic operation principles of a lightweight, low power, low cost, portable ion chromatograph utilizing open tubular ion chromatography in capillary columns coated with multi-layer polymeric stationary phases are demonstrated. A minimalistic configuration of a portable IC instrument was developed that does not require any chromatographic eluent delivery system, nor sample injection device as it uses gravity-based eluent flow and hydrodynamic sample injection adopted from capillary electrophoresis. As a detection device, an inexpensive commercially available capacitance sensor is used that has been shown to be a suitable substitute for contactless conductivity detection in capillary separation systems. The built-in temperature sensor allows for baseline drift correction typically encountered in conductivity/capacitance measurements without thermostating device. The whole instrument does not require any power supply for its operation, except the detection and data acquisition part that is provided by a USB port of a Netbook computer. It is extremely lightweight, its total weight including the Netbook computer is less than 2.5 kg and it can be continuously operated for more than 8 h. Several parameters of the instrument, such as detection cell design, eluent delivery systems and data treatment were optimized as well as the composition of eluent for non-suppressed ion chromatographic analysis of common inorganic cations (Na+, NH4+, K+, Cs+, Ca2+, Mg2+, transition metals). Low conductivity eluents based on weakly complexing organic acids such as tartaric, oxalic or pyridine-2,6-dicarboxylic acids were used with contactless capacitance detection for simultaneous separation of mono- and divalent cations. Separation of Na+ and NH4+ cations was optimized by addition of 18-crown-6 to the eluent. The best separation of 6 metal cations commonly present in various environmental samples was accomplished in less than 30 min using a 1.75 mM pyridine-2,6-dicarboxylic acid and 3 mM 18-crown-6 eluent with excellent repeatability (below 2%) and detection limits in the low micromolar range. The analysis of field samples is demonstrated; the concentrations of common inorganic cations in river water, mineral water and snow samples were determined.  相似文献   

17.
A neutron activation method based on the measurement of tritium radioactivity produced by6Li (n,)3H reaction was applied to determine the isotopic abundance of6Li in aqueous solution with known lithium concentration. Tritium radioactivity was measured with a low background liquid scintillation counter over a period of 2000 min. The present method demonstrated a good linearity between the isotopic abundance of6Li and tritium radioactivity produced per unit amount of lithium in a wide range of lithium concentration. A comparison of the present data with those from mass spectrometry showed agreement, though our method was 10 times less sensitive, than mass spectrometry. The present new approach should thus prove quite useful for determining the isotopic abundance of6Li.  相似文献   

18.
Abstract

A method is described for the formation of fluorescent conjugates of the sulfidopeptide leukotrienes (LTC4, LTD4, and LTE4) by reaction of the primary amine moiety of these metabolites with o-phthalaldehyde. Separation of the fluorescent derivatives was achieved by reverse-phase high performance liquid chromatography in less than 30 minutes using a convex gradient of methanol-50 mM Na Acetate-5% Tetrahydrofuran pH 5.5. Detection limits realized under the conditions described were 0.35 ng, 3.8 ng and 3.7 ng for LTC4, LTD4, and LTE4, respectively. This represents an Increased sensitivity over detection of these metabolites by ultra-violet spectroscopy. The leukotriene-OPA derivatives are fully stable for 50 minutes at 23°C and for at least 4 hours at 0°C. The method is applied to the detection of LTC4 generated by zymosan stimulated murine peritoneal macrophages.  相似文献   

19.
Transport numbers of the 6Li and 7Li ions in solid electrolyte Li3AlN2 are estimated by passing a constant current and measuring their concentration distribution at 300°C. Up to [6Li] = 50–55 at. %, the 7Li ions are more mobile.  相似文献   

20.
Separation and determination of some common metal ions was achieved with methyl 3‐amino‐3‐(pyridin‐3‐yl)propanoate dihydrochloride (MAPP) as an ion‐pairing reagent and pyridine as a detectable counter‐ion for indirect UV detection at 254 nm. The effects of the complexing reagent and chromophore concentrations, applied voltage, and organic solvent content on the separation were investigated. The optimized separation was carried out in a running electrolyte containing 16 mM MAPP and 20 mM pyridine at pH 4.0 and was successfully applied to the qualitative and quantitative analysis of Li+, Na+, Mg2+, Ca2+, Ba2+, Ni2+, and Zn2+ in pharmaceutical vitamin preparations and various water samples.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号