首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
A poly(2‐aminophenylbenzimidazole)/gold nanoparticles (P2AB/AuNPs) coated disposable pencil graphite electrode (PGE) was fabricated as an enzyme‐free sensor for the H2O2 determination. P2AB/AuNPs and P2AB were successfully synthesized electrochemically on PGE in acetonitrile for the first time. The coatings were characterized by scanning electron microscopy, X‐ray diffraction spectroscopy, Energy‐dispersive X‐ray spectroscopy, Surface‐enhanced Raman spectroscopy, and UV‐Vis spectroscopy. AuNPs interacted with P2AB as carrier enhances the electrocatalytic activity towards reduction of H2O2. The analytical performance was evaluated in a 100 mM phosphate buffer solution at pH 6.5 by amperometry. The steady state current vs. H2O2 concentration is linear in the range of 0.06 to 100 mM (R2=0.992) with a limit of detection 3.67×10?5 M at ?0.8 V vs. SCE and no interference is caused by ascorbic acid, dopamine, uric acid, and glucose. The examination for the sensitive determination of H2O2 was conducted in commercially available hair oxidant solution. The results demonstrate that P2AB/AuNPs/PGE has potential applications as a sensing material for quantitative determination of H2O2.  相似文献   

2.
A layer‐by‐layer (LbL) thin film composed of poly(ethyleneimine) (PEI) and carboxymethyl cellulose (CMC) was prepared on the surface of a gold (Au) disk electrode and the LbL layer was impregnated with hemin to fabricate amperometric hydrogen peroxide (H2O2) sensors. Hemin can be easily immobilized in the LbL layer by immersing the LbL film‐coated electrode in the hemin solution. The hemin‐modified electrode thus prepared exhibited an amperometric response to H2O2 on the basis of the electrochemical reduction catalyzed by hemin. The output current of the hemin‐modified electrode depended on the concentration of H2O2 over the range of 0.005–1.0 mM. Thus, the LbL film composed of PEI and CMC was found to be an excellent material for the facile preparation of hemin‐based H2O2 sensors.  相似文献   

3.
《Electroanalysis》2004,16(9):736-740
A new enzyme‐based amperometric biosensor for hydrogen peroxide was developed relying on the efficient immobilization of horseradish peroxidase (HRP) to a nano‐scaled particulate gold (nano‐Au) film modified glassy carbon electrode (GC). The nano‐Au film was obtained by a chitosan film which was first formed on the surface of GC. The high affinity of chitosan for nano‐Au associated with its amino groups resulted in the formation of nano‐Au film on the surface of GC. The film formed served as an intermediator to retain high efficient and stable immobilization of the enzyme. H2O2 was detected using hydroquinone as an electron mediator to transfer electrons between the electrode and HRP. The HRP immobilized on nano‐Au film maintained excellent electrocatalytical activity to the reduction of H2O2. The experimental parameters such as the operating potential of the working electrode, mediator concentration and pH of background electrolyte were optimized for best analytical performance of amperometry. The linear range of detection for H2O2 is from 6.1×10?6 to 1.8×10?3 mol L?1 with a detection limit of 6.1 μmol L?1 based on signal/noise=3. The proposed HRP enzyme sensor has the features of high sensitivity (0.25 Almol?1cm?2), fast response time (t90%≤10 s) and a long‐term stability (>1 month). As an extension, glucose oxidase (GOD) was chemically bound to HRP‐modified electrode. A GOD/HRP bienzyme‐modified electrode formed in this way can be applied to the determination of glucose with satisfactory performance.  相似文献   

4.
A novel Prussian blue/copper‐gold bimetallic nanoparticles hybrid film modified electrode was prepared by electrochemical deposition on a glassy carbon electrode (PB/Cu‐AuNPs/GCE). Morphology and electrochemistry of this electrode were studied by UV‐vis spectroscopy, scanning electron microscopy, X‐ray diffraction, cyclic voltammetry and electrochemical impedance spectroscopy. The sensor showed significantly better electrocatalytic activity for the reduction of hydrogen peroxide in comparison with the single PB/GCE and PB/AuNPs/GCE. This was attributed to the synergistic effect of PB and Cu‐Au bimetallic nanoparticles. Also, the sensor demonstrated an overall high level of performance for the analysis of H2O2 in the concentration range from 0.002 to 0.84 mM.  相似文献   

5.
《Electroanalysis》2006,18(3):259-266
In this paper, a new strategy for constructing a mediator‐type amperometric hydrogen peroxide (H2O2) microbiosensor was described. An electropolymerized thionine film (PTH) was deposited directly onto a gold electrode surface. The resulting redox film was extremely thin, adhered well onto a substrate (electrode), and had a highly cross‐linked network structure. Consequently, horseradish peroxidase (HRP) was successfully immobilized on nanometer‐sized Au colloids, which were supported by thiol‐tailed groups of 11‐mercaptoundecanoic acid (11‐MUA) monolayer covalently bound onto PTH film. With the aid of the PTH mediator, HRP‐labeled Au colloids microbiosensor displayed excellent electrocatalytical response to the reduction of H2O2. This matrix showed a biocompatible microenvironment for retaining the native activity of the covalent HRP and a very low mass transport barrier to the substrate, which provided a fast amperometric response to H2O2. The proposed H2O2 microbiosensor exhibited linear range of 3.5 μM–0.7 mM with a detection limit of 0.05 μM (S/N=3). The response showed a Michaelis‐Menten behavior at larger H2O2 concentrations. The KMapp value for the biosensors based on 24 nm Au colloids was found to be 47 μM, which demonstrated that HRP immobilized on Au colloids exhibited a high affinity to H2O2 with no loss of enzymatic activity. This microbiosensor possessed good analytical performance and storage stability.  相似文献   

6.
A new third‐generation biosensor for H2O2 assay was developed on the basis of the immobilization of horseradish peroxidase (HRP) in a nanocomposite film of carbon nanotubes (CNTs)‐SBA‐15 modified gold electrode. The biological activity of HRP immobilizing in the composite film was characterized by UV‐vis spectra. The HRP immobilized in the nanocomposite matrix displayed excellent electrocatalytic activity to the reduction of H2O2. The effects of the experimental variables such as solution pH and working potential were investigated using steady‐state amperometry. Under the optimal conditions, the resulting biosensor showed a linear range from 1 µM to 7 mM and a detection limit of 0.5 µM (S/N=3). Moreover, the stability and reproducibility of this biosensor were evaluated with satisfactory results.  相似文献   

7.
In this study, a novel non‐enzymatic hydrogen peroxide (H2O2) sensor was fabricated based on gold nanoparticles/carbon nanotube/self‐doped polyaniline (AuNPs/CNTs/SPAN) hollow spheres modified glassy carbon electrode (GCE). SPAN was in‐site polymerized on the surface of SiO2 template, then AuNPs and CNTs were decorated by electrostatic absorption via poly(diallyldimethylammonium chloride). After the SiO2 cores were removed, hollow AuNPs/CNTs/SPAN spheres were obtained and characterized by transmission electron microscopy (TEM), field‐emission scanning electron microscopy (FESEM) and Fourier transform infrared spectroscopy (FTIR). The electrochemical catalytic performance of the hollow AuNPs/CNTs/SPAN/GCE for H2O2 detection was evaluated by cyclic voltammetry (CV) and chronoamperometry. Using chronoamperometric method at a constant potential of ?0.1 V (vs. SCE), the H2O2 sensor displays two linear ranges: one from 5 µM to 0.225 mM with a sensitivity of 499.82 µA mM?1 cm?2; another from 0.225 mM to 8.825 mM with a sensitivity of 152.29 µA mM?1 cm?2. The detection limit was estimated as 0.4 µM (signal‐to‐noise ratio of 3). The hollow AuNPs/CNTs/SPAN/GCE also demonstrated excellent stability and selectivity against interferences from other electroactive species. The sensor was further applied to determine H2O2 in disinfectant real samples.  相似文献   

8.
The performance of an enzyme sensor fabricated through covalent bond formation on the HRP‐bonded poly(1,8‐diaminonaphthalene) (polyDAN) layer with gold nanoparticles (AuNPs) was applied to catalyze the electrochemical reduction of H2O2. The surface characteristics of the sensor probe were studied using cyclic voltammetry, SEM, XPS, QCM, and impedance spectroscopy. The AuNP‐deposited surface resulted in higher conductivity and sensitivity for H2O2 detection in phosphate buffer solution. A linear calibration plot was obtained in the H2O2 concentration range between 10.0 μM and 25.0 mM with detection limit 5.0±1.25 μM. The lifetime of HRP/polyDAN/AuNP/GC probe was over 70 days without response loss.  相似文献   

9.
AuNPs monolayer doping Poly(3,4-ethylenedioxythiophene):polystyrenesulfonate (PEDOT : PSS) film on interdigitated electrode had been fabricated into AuNPs/PEDOT : PSS Janus film sensor to detect hydrogen sulfide (H2S). The results show that the Janus film sensors have a wide measurement range of H2S concentration. The sensitivity of PEDOT : PSS/AuNPs sensor grows up with the thickness of Janus film increases. The resistance response of AuNPs Janus film was affected little by the rough surface states of PEDOT : PSS film. In addition, the PEDOT : PSS/AuNPs film sensor had been used again to detect H2S. This work presents a platform to inspire a novel high sensitive chemiresistive sensor via nanoparticles monolayer.  相似文献   

10.
A novel photoelectrochemcial biosensing system was fabricated based on the composition of horseradish peroxidase (HRP), flower‐like CuInS2 (CIS) and graphene on indium tin oxide (ITO) electrode for detecting H2O2. The graphene layer was used as highly conductive scaffolds for electron transport from the ITO electrode to CIS. Furthermore, the flower‐like CIS enhanced the multi‐reflection of light and provided matrixes for the adsorption of HRP. Utilizing one‐pot solvothermal method, we prepared flower‐like CIS‐graphene hybrid (GCIS). Electrochemical tests displayed advantage of graphene with better electron conductivity, and HRP/GCIS showed higher photoelectrochemical behavior.  相似文献   

11.
《Electroanalysis》2018,30(1):137-145
3D Flower‐like manganese dioxide (MnO2) nanostructure with the ability of catalysis for hydrogen peroxide (H2O2) and super large area that can support gold nanoparticles (AuNPs) with enhanced activity of electron transfer have been developed. The nanostructure of hybrids was prepared by directly mixing citric‐capped AuNPs and 3‐aminopropyltriethoxysilane (3‐APTES)‐capped nano‐MnO2 using an electrostatic adsorption strategy. The Au‐MnO2 composite was extensively characterized by scanning electron microscope (SEM), X‐ray diffraction (XRD), Fourier transform infrared spectroscopy (FTIR), the Brunauer‐Emmett‐Teller (BET) method and X‐ray photoemission spectroscopy (XPS). Electrochemical properties were evaluated through cyclic voltammetry (CV) and amperometric method. The prepared sensor showed excellent electrochemical properties towards H2O2 with a wide linear range from 2.5×10−3∼1.39 mM and 3.89∼13.89 mM. The detection limit is 0.34 μM (S/N=3) with the sensitivities of 169.43 μA mM−1 cm−2 and 55.72 μA mM−1 cm−2. The detection of real samples was also studied. The result exhibited that the prepared sensor can be used for H2O2 detection in real samples.  相似文献   

12.
We report herein a simple device for rapid biosensing consisting of a single microfluidic channel made from poly(dimethylsiloxane) (PDMS) coupled to an injector, and incorporating a biocatalytic sensing electrode, reference and counter electrodes. The sensing electrode was a gold wire coated with 5 nm glutathione-decorated gold nanoparticles (AuNPs). Sensitive detection of H2O2 based on direct bioelectrocatalysis by horseradish peroxidase (HRP) was used for evaluation. HRP was covalently linked the glutathione–AuNPs. This electrode presented quasi-reversible cyclic voltammetry peaks at ?0.01 V vs. Ag/AgCl at pH 6.5 for the HRP heme FeIII/FeII couple. Direct electrochemical activity of HRP was used to detect H2O2 at high sensitivity with a detection limit of 5 nM in an unmediated system.  相似文献   

13.
唐明宇袁若  柴雅琴 《中国化学》2006,24(11):1575-1580
The third generation amperometric biosensor for the determination of hydrogen peroxide (H2O2) has been described. For the fabrication of biosensor, o-aminobenzoic acid (oABA) was first electropolymerized on the surface of platinum (Pt) electrode as an electrostatic repulsion layer to reject interferences. Horseradish peroxidase (HRP) absorbed by nano-scaled particulate gold (nano-Au) was immobilized on the electrode modified with polymerized o-aminobenzoic acid (poABA) with L-cysteine as a linker to prepare a biosensor for the detection of H2O2. Amperometric detection of H2O2 was realized at a potential of +20 mV versus SCE. The resulting biosensor exhibited fast response, excellent reproducibility and sensibility, expanded linear range and low interferences. Temperature and pH dependence and stability of the sensor were investigated. The optimal sensor gave a linear response in the range of 2.99×10^-6 to 3.55×10^-3 mol·L^-1 to H2O2 with a sensibility of 0.0177 A·L^-1·mol^-1 and a detection limit (S/N = 3) of 4.3×10^-7 mol·L^-1. The biosensor demonstrated a 95% response within less than 10 s.  相似文献   

14.
We developed a novel iron‐tetrasulfophthalocyanine‐graphene‐Nafion (FeTSPc‐GR‐Nafion) modified screen‐printed electrode to determine hydrogen peroxide (H2O2) with high sensitivity and selectivity. The nanocomposite film (FeTSPc‐GR‐Nafion) exhibits an excellent electrocatalytic activity towards oxidation of H2O2 at a potential of +0.35 V in the absence of enzyme. A comparative study reveals that the FeTSPc‐GR complexes play a dual amplification role. Amperometric experiment indicates that the sensors possess good sensitivity and selectivity, with a linear range from 2.0×10?7 M to 5.0×10?3 M and a detection limit of 8.0×10?8 M. This sensor has been successfully used to develop the glucose biosensor and has also been applied to determine H2O2 in sterile water.  相似文献   

15.
《Electroanalysis》2017,29(12):2818-2831
Immobilization of biomolecules with a proper orientation is considered as a basis for diverse biotechnological applications. Herein, we report a host‐guest inclusion complexation between β‐cyclodextrin (β‐CD) and biotin as a versatile approach for the immobilization of biomolecules. As a practical application, a sandwich‐type electrochemical immunosensor was designed for the determination of prostate specific antigen (PSA). The immunosensor was fabricated by in situ electropolymerization of poly(N‐acetylaniline) onto a rGO‐modified Pt electrode. Then, β‐CD was covalently grafted onto the over‐oxidized polymer backbone. For improving the efficiency of the assay, AuNPs were casted on the polymeric film, on the surface of which thionine (TH) as an electron mediator was covalently immobilized. Using a host‐guest inclusion complexation between β‐CD and biotin, a β‐CD/biotin‐Ab1/PSA/Ab2‐horseradish peroxidase (HRP) sandwich was formed on the electrode surface. The analytical signal was produced via electrochemical reduction of THox, generated by biocatalytic oxidation of the THred in the presence of HRP/H2O2. Under optimal conditions, the proposed sensor responded linearly to PSA in the range from 10.0 pg mL−1 to 25.0 ng mL−1, with a low detection limit of 6.7 pg mL−1 (S/N=3). Kinetic parameters of the interaction of β‐CD with Ab1 were also investigated. Finally, the applicability of the immunosensor was successfully investigated for the detection of PSA in human serum samples.  相似文献   

16.
A novel biosensor was developed by entrapping cytochrome c (Cyt c) in thin films of the room temperature ionic liquid (RTIL) containing nanocomposites of poly(diallyldimethylammonium chloride)‐graphene nanosheets‐gold nanoparticles (PDDA‐Gp‐AuNPs) at a 11‐mercaptoundecanoic acid‐6‐mercapto‐1‐hexanol modified gold electrode. The synthesized PDDA‐Gp‐AuNPs hybrid nanocomposites were characterized by UV‐vis spectroscopy, Raman spectroscopy, scanning electron microscopy and atomic force microscopy. The PDDA‐Gp‐AuNPs nanocomposites could increase the effective surface of the electrode, enhance the fixed amount of Cyt c on the electrode surface, promote the electron transfer and facilitate the catalytic activity of Cyt c. The RTIL could provide a biocompatible microenvironment to keep Cyt c biological activities, act as an effective mediator to immobilize a large number of Cyt c on the electrode and have good conductivity to improve electron transfer. Therefore, the resultant electrode exhibited good electrochemical performance and electrocatalytic activity. It could be used for electrochemical detection of H2O2 with rapid response, high sensitivity, wide linear range and low detection limit, as well as good stability, repeatability and selectivity. The sensor might be promising for practical application.  相似文献   

17.
《Analytical letters》2012,45(5):885-897
Hemoglobin (Hb) was successfully immobilized on a gold electrode modified with gold nanoparticles (AuNPs) via a molecule bridge 1,6-hexanedithiol (HDT). The AFM images suggested that the HDT/gold electrode could adsorb more AuNPs. UV-vis spectra indicated that Hb on AuNPs/HDT film retained its near-native secondary structures. The electrochemical behaviors of the sensor were characterized with cyclic voltammetric techniques. The resultant electrode displayed an excellent electrocatalytical response to the reduction of hydrogen peroxide (H2O2). The linear relationship existed between the catalytic current and the H2O2 concentration ranging from 5.0 × 10?8 to 1.0 × 10?6 mol · L?1. The detection limit (S/N = 3) was 1.0 × 10?8 mol · L?1.  相似文献   

18.
《中国化学会会志》2018,65(9):1127-1135
In this paper, a WS2 nanosheet was modified on the surface of a carbon ionic liquid electrode (CILE), and horseradish peroxidase (HRP) was further fixed on the electrode with a Nafion film. Direct electrochemistry and bioelectrocatalysis of HRP incorporated on the modified electrode were investigated in detail. On Nafion/HRP/WS2/CILE, a pair of well‐defined quasi‐reversible redox peaks appeared on the cyclic voltammogram, indicating that the presence of the WS2 nanosheet on the electrode surface could provide a specific interface with large surface area for HRP and its direct electron transfer rate was greatly enhanced. The formal potential (E0) obtained was –0.179 V, which was the typical feature of heme Fe(III)/Fe(II) in HRP. The electron transfer coefficient (α) and the heterogeneous electron transfer rate constant (ks) of HRP were calculated as 0.44 and 1.01 s–1, respectively. This HRP‐modified electrode showed excellent electrocatalytic activity for the reduction of trichloroacetic acid and NaNO2 with a wide linear range and low detection limit. Real samples were detected by this proposed method, indicating the successful fabrication of a new third‐generation electrochemical enzyme sensor utilizing the WS2 nanosheet.  相似文献   

19.
Electrically conducting poly(3,4‐ethylenedioxythiophene) (PEDOT) film doped with silicomolybdate (SiMo12O404? or SiMo12) was synthesized by electrochemical polymerization. The synthesized film is capable of fast charge propagation during redox reactions in strong acid medium 0.2 M H2SO4 solution. The modified electrode was used towards reduction of bromate and successfully employed as an amperometric sensor for bromate and also above modified electrode was investigated for ascorbic acid oxidation.  相似文献   

20.
Many efforts have been made toward the achievement of high sensitivity in capillary electrophoresis coupled with chemiluminescence detection (CE‐CL). This work describes a novel dual‐signal amplification strategy for highly specific and ultrasensitive CL detection of human platelet‐derived growth factor–BB (PDGF–BB) using both aptamer and horseradish peroxidase (HRP) modified gold nanoparticles (HRP–AuNPs–aptamer) as nanoprobes in CE. Both AuNPs and HRP in the nanoprobes could amplify the CL signals in the luminol–H2O2 CL system, owing to the excellent catalytic behavior of AuNPs and HRP in the CL system. Meanwhile, the high affinity of aptamer modified on the AuNPs allows detection with high specificity. As proof‐of‐concept, the proposed method was employed to quantify the concentration of PDGF–BB from 0.50 to 250 fm with a detection limit of 0.21 fm. The applicability of the assay was further demonstrated in the analysis of PDGF–BB in human serum samples with acceptable accuracy and reliability. The result of this study exhibits distinct advantages, such as high sensitivity, good specificity, simplicity, and very small sample consumption. The good performances of the proposed strategy provide a powerful avenue for ultrasensitive detection of rare proteins in biological sample, showing great promise in biochemical analysis. Copyright © 2015 John Wiley & Sons, Ltd.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号