首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 140 毫秒
1.
《Analytical letters》2012,45(11):1797-1807
Fe3O4 magnetic nanoparticles were synthesized by chemical co-precipitation with sodium citrate as a surfactant and were used with chitosan to construct a novel hydrogen peroxide sensor. The electrochemical behavior of hydrogen peroxide at the sensor was investigated by cyclic voltammetry. The composite film electrocatalyzed the reduction of hydrogen peroxide, and the peak current increased linearly with concentration from 1.00 × 10?5 to 1.00 × 10?3 mol · L?1 (R = 0.9974) with a detection limit of 1.53 × 10?6 mol · L?1. This novel nonenzyme sensor provided good sensitivity, stability, and precision with potential applications.  相似文献   

2.
儿茶酚胺是一类非常重要的神经递质,在人体的心血管系统、神经系统、内分泌腺、肾脏、平滑肌等组织系统的生理活动中起着广泛的调节作用。肾上腺素为儿茶酚胺的一种,建立灵敏、高效的肾上腺素检测技术具有重要的临床意义。本文将银(Ⅲ)配合物与鲁米诺组成新的流动注射化学发光体系,利用碱性介质中肾上腺素对三价银配合物-鲁米诺化学发光体系有明显的增强效应来测定肾上腺素的含量,并据此建立了高效测定肾上腺素的流动注射化学发光新方法。在优化的条件下,该方法测定肾上腺素的线型范围为1.0×10-9~1.0×10-7 mol L-1,检出限为8.0×10-10 mol L-1,对1.5×10-8 mol L-1肾上腺素11次平行测定,其相对标偏差为2.9%。利用建立的分析方法测定了药物肾上腺素,并对三价银-鲁米诺化学发光新体系测定肾上腺素的反应机理进行了讨论。  相似文献   

3.
A novel biosensor by electrochemically codeposited Pt nanoclusters and DNA film was constructed and applied to detection of dopamine (DA) and uric acid (UA) in the presence of high concentration ascorbic acid (AA). Scanning electron microscopy and X‐ray photoelectron spectroscopy were used for characterization. This electrode was successfully used to resolve the overlapping voltammetric response of DA, UA and AA into three well‐defined peaks with a large anodic peak difference (ΔEpa) of about 184 mV for DA and 324 mV for UA. The catalytic peak current obtained from differential pulse voltammetry was linearly dependent on the DA concentration from 1.1× 10?7 to 3.8×10?5 mol·L?1 with a detection limit of 3.6×10?8 mol·L?1 (S/N=3) and on the UA concentration from 3.0×10?7 to 5.7×10?5 mol·L?1 with a detection limit of 1.0×10?7 mol·L?1 with coexistence of 1.0×10?3 mol·L?1 AA. The modified electrode shows good sensitivity and selectivity.  相似文献   

4.
A novel nanocomposite designed by the assembly of the positively charged poly(diallyldimethylammonium chloride) protected gold nanoparticles (PDDA‐GNPs), and the negatively charged multi‐walled carbon nanotubes (MWCNTs) on ITO electrode via electrostatic interaction, was used as a supporting matrix for immobilizing hemoglobin (Hb) to develop a high‐performance hydrogen peroxide (H2O2) biosensor. The cyclic voltammetrys of immobilized Hb showed a pair of well‐defined and quasi‐reversible redox peaks with the formal potential of ‐0.205V (vs. SCE) and the peak‐to‐peak potential separation of 44 mV at a scan rate of 100 mV×s?1 in 0.1 mol×L?1 pH 7.0 PBS. Under the optimized experimental conditions, a linearity range for determination of H2O2 was from 2.0 × 10?6 to 5.2 × 10?4 mol×L?1 with a correlation coefficient of 0.9994 (n = 37) and a detection limit of 8.4 × 10?7 mol×L?1. The biosensor displayed excellent electrochemical and electrocatalytic response to the reduction of H2O2, high sensitivity, long‐term stability, good bioactivity and selectivity.  相似文献   

5.
《Analytical letters》2012,45(5):885-897
Hemoglobin (Hb) was successfully immobilized on a gold electrode modified with gold nanoparticles (AuNPs) via a molecule bridge 1,6-hexanedithiol (HDT). The AFM images suggested that the HDT/gold electrode could adsorb more AuNPs. UV-vis spectra indicated that Hb on AuNPs/HDT film retained its near-native secondary structures. The electrochemical behaviors of the sensor were characterized with cyclic voltammetric techniques. The resultant electrode displayed an excellent electrocatalytical response to the reduction of hydrogen peroxide (H2O2). The linear relationship existed between the catalytic current and the H2O2 concentration ranging from 5.0 × 10?8 to 1.0 × 10?6 mol · L?1. The detection limit (S/N = 3) was 1.0 × 10?8 mol · L?1.  相似文献   

6.
唐明宇袁若  柴雅琴 《中国化学》2006,24(11):1575-1580
The third generation amperometric biosensor for the determination of hydrogen peroxide (H2O2) has been described. For the fabrication of biosensor, o-aminobenzoic acid (oABA) was first electropolymerized on the surface of platinum (Pt) electrode as an electrostatic repulsion layer to reject interferences. Horseradish peroxidase (HRP) absorbed by nano-scaled particulate gold (nano-Au) was immobilized on the electrode modified with polymerized o-aminobenzoic acid (poABA) with L-cysteine as a linker to prepare a biosensor for the detection of H2O2. Amperometric detection of H2O2 was realized at a potential of +20 mV versus SCE. The resulting biosensor exhibited fast response, excellent reproducibility and sensibility, expanded linear range and low interferences. Temperature and pH dependence and stability of the sensor were investigated. The optimal sensor gave a linear response in the range of 2.99×10^-6 to 3.55×10^-3 mol·L^-1 to H2O2 with a sensibility of 0.0177 A·L^-1·mol^-1 and a detection limit (S/N = 3) of 4.3×10^-7 mol·L^-1. The biosensor demonstrated a 95% response within less than 10 s.  相似文献   

7.
A flow-injection chemiluminescence (CL) method for the determination of melatonin based on the CL reaction of melatonin with hydrogen peroxide and sodium hypochlorite (NaOCl) in a basic alkaline solution was developed. The possible CL mechanism has been discussed, and a proposal for the reaction pathway was given that singlet oxygen was clarified to be produced in this reaction system and was responsible for the CL emission. Under the optimized conditions, the linear concentration range of application was 1.0×10^-7-2.5 × 10^-4 moloL-I with a de- tection limit of 5.0 ×10^-8 moloL-1 (S/N= 3). The relative standard deviation for eight repeated measurements of 1.0×10^-6 mol·L^-1 melatonin was 2.8%. The interferences of several important biological substances, some indole compound, cations and anions were studied. No interference was found for the anions, glucose, starch, most of cations and low concentration (less than 3.0 × 10^-6 mol·L^-1) of some biological substances and indole compound. The method was applied to the determination of melatonin in rat pineal gland and drug with satisfactory results. The sample throughput was 90 injections per hour.  相似文献   

8.
LI Jing 《中国化学》2009,27(12):2373-2378
A novel chemically modified electrode based on the dispersion of gold nanoparticles on polypyrrole nanowires has been developed to investigate the oxidation behavior of nitrite using cyclic voltammetry, differential pulse voltammetry and chronoamperometry techniques. The diffusion coefficient (D), electron transfer coefficient (α) and charge transfer rate constant (k) for the oxidation of nitrite were determined. The modified electrode exhibited high electrocatalytic activity toward the oxidation of nitrite. The catalytic peak current was found to be linear with nitrite concentrations in the range of 8.0×10?7?2.5×10?3 mol·L?1 with a detection limit of 1.0×10?7 mol·L?1 (s/n=3). The proposed method was successfully applied to the detection of nitrite in water samples with obtained satisfactory results. Additionally, the sensor also showed excellent sensitivity, anti‐interference ability, reproducibility and stability properties.  相似文献   

9.
《Analytical letters》2012,45(15):2537-2547
A promising nanotechnological material, zirconia nanoparticles modified with SiO2, was used as a medium for the immobilization of laccase to construct a novel biosensor that exhibits sensitive amperometric response to catechol in 0.1 mol · L?1 phosphate buffer (pH 6.0) using cyclic voltammetry. The linear response to catechol was from 1.0 × 10?6 to 1.0 × 10?4 mol · L?1 and the detection limit was 3.5 × 10?7 mol · L?1 at a signal-to-noise ratio of 3. The biosensor exhibited good stability, precision, and few interferences.  相似文献   

10.
IntroductionThelevelofglucoseinbloodorurineindicateshyper andhypoglycaemia ,bothofwhichcanresultfromavarietyofendocrinedisorders .1 4 Therapidandreliabledetermi nationofglucoselevelisaroutineprojectinclinicchem istry.Urinesamplesaresaferandmoreconvenientthanbloodones .Meanwhile ,theconcentrationofglucoseinserumiscloselyassociatedwiththatinurine .2 4 Eventhoughglucoseelectrodeshavebeensuccessfullyusedinseruminclinicalapplication ,thequestionstillremainedofhowtodetecttheglucoselevelinurine ,wh…  相似文献   

11.
Nanostructured alpha‐nickel hydroxide (α‐Ni(OH)2) immobilized on a Fluorine‐doped Tin Oxide (FTO) surface was explored for the construction of hydrogen peroxide amperometric Flow Injection Analysis (FIA) sensors. Their notable electrocatalytic activity and heterogeneous electron‐transfer rate were confirmed by the appearance of a broad and intense peak associated with the oxidation of hydrogen peroxide and the enhancement of sensibility in hydrodynamic conditions. The α‐Ni(OH)2 electrodes exhibited a broad dynamic range (5×10?6 to 1×10?3 mol L?1), low detection limit (2×10?7 mol L?1), good repeatability (RSD=1.29 % for 20 successive analyses), and a sensitivity greater than 500 µA mmol?1 L?1 cm?2.  相似文献   

12.
An electrochemical sensor for theophylline (ThPh) was prepared by electropolymerizing o-phenylenediamine on a glassy carbon electrode in the presence of ThPh via cyclic voltammetry, followed by deposition of gold nanoparticles using a potentiostatic method. The effects of pH, ratio between template molecule and monomer, number of cycles for electropolymerization, and of the solution for extraction were optimized. The current of the electro-active model system hexacyanoferrate(III) and hexacyanoferrate(IV) decreased linearly with successive addition of ThPh in the concentration range between 4.0?×?10?7?~?1.5?×?10?5 mol·L?1 and 2.4?×?10?4?~?3.4?×?10?3 mol·L?1, with a detection limit of 1.0?×?10?7 mol·L?1. The sensor has an excellent recognition capability for ThPh compared to structurally related molecules, can be regenerated and is stable.
Figure
In this paper, an electrochemical sensor for theophylline (ThPh) was prepared by electropolymerizing o-phenylenediamine (o-PD) on a glassy carbon electrode in the presence of ThPh via cyclic voltammetry, followed by deposition of gold nanoparticles to enhance the sensitivity of the sensor. Therefore, the sensor showed a high sensitivity for ThPh determining. Peak current of [Fe(CN)6]3?/[Fe(CN)6]4? varied linearly with the concentration of ThPh in the range of 4.0×10-7~1.5×10-5 mol·L-1 and 2.4×10-4~3.4×10-3 mol·L-1, and the detection limit reached 1.0×10-7 mol·L-1. Compared to structurally related molecules, the sensor also has a high recognition capability for ThPh. With excellent regeneration property and stability, the present sensor maybe provides a new class of polymer modified electrodes for sensor applications.  相似文献   

13.
The electrocatalysis oxidation of guanosine‐5′‐monophosphate (GMP) was investigated on Mg‐Al layered double hydroxide (LDH) functionalized with sodium dodecyl sulfate (SDS) and room temperature ionic liquid (RTIL) modified glass carbon electrode (GCE). The cyclic voltammogram of GMP on the modified electrode (RTIL/ LDH‐SDS/GCE) exhibited a well defined anodic peak at 1.091 V in 0.2 mol·L?1 pH 4.4 acetate buffer solution. The GMP oxidation was enhanced in the presence of anionic surfactant in the ?lms. The results suggest that the surfactant molecules intercalate the LDH layers to preconcentrate GMP molecules and the RTIL showed good ionic conductivity. The experimental parameters were optimized, the kinetic parameters were investigated and the probable oxidation mechanism was proposed. Under the optimized conditions, the oxidation peak current was proportional to GMP concentration in the range from 5.0×10?7 to 1.0×10?4 mol·L?1 with the correlation coefficient of 0.9987 and the detection limit was 1.0×10?7 mol·L?1. The RTIL/LDH‐SDS/GCE showed a good electrochemical response to the oxidation of GMP and would be developed into a new biosensor.  相似文献   

14.
刘宁高伟  宋俊峰 《中国化学》2006,24(11):1657-1661
Voltammetry using solid electrodes usually suffers from the contamination due to the deposition of the redox products of analytes on the electrode surface. The contamination has resulted in poor reproducibility and overelaborate operation procedures. The use of the chemical catalysis of oxidant on the reduction product of analyte not only can eliminate the contamination of analyte to solid electrodes but also can improve the faradaic response of analyte. This work introduced both the catalysis of oxidant K2S2O8 and the enhancement of surfactant Triton X-100 on the faraday response of amiodarone into an adsorptive stripping voltammetry at a carbon paste electrode for the determination of amiodarone. The method exhibits high sensitivity, good reproducibility and simple operation procedure. In 0.2 mol·L^-1 HOAc-NaOAc buffer (pH=5.3) containing 2.2×10^-2 mol·L^-1 K2S2O8 and 0.002% Triton X-100, the 2.5th-order derivative stripping peak current of the catalytic wave at 0.3 V (vs. Ag/AgCl) is rectilinear to amiodarone concentration in the range of 2.0×10^-10-2.3×10^-8 mol·L^-1 with a detection limit of 1.5×10^-10 mol·L^-1 after accumulation at 0 V for 30 s.  相似文献   

15.
用紫外可见光谱、稳态荧光发射及荧光寿命测定研究了核酸猝灭十二烷基磺酸钠胶束中的健那绿荧光。水溶液中弱的健那绿荧光在十二烷基磺酸钠胶束中被大大加强,其最大发射从425纳米移至410纳米,核酸的加入将猝灭健那绿的荧光,当健那绿浓度为2.5×105 mol•L-1时,荧光猝灭(F0/F)分别与小牛胸腺DNA及鱼精DNA在2.4×108 到 1.08×107及 1.9×108 到 3.8×108 mol•L-1范围内成正比, 检测限分别为1.3×108 mol•L-1 (小牛胸腺DNA)及6.3×109 mol•L-1 (鱼精DNA)。当DNA浓度较高时, 将系统偏离Stern-Volmer方程。这是因为动态猝灭和静态猝灭同时存在。方法已应用于鸡血提取液中DNA的测定, 测定结果与紫外法一致。  相似文献   

16.
Low amount of manganese meso‐tetraphenyl porphyrin [Mn(TPP)] was used for highly efficient selective oxidation of sulfide to sulfone by hydrogen peroxide at room temperature. Sulfones were produced directly with yields generally around 90% while the catalyst concentration was only 4×10?5 mol·L?1. In a large‐scale experiment of thioanisole oxidation, the isolated yield of sulfone (87%) was obtained and the turnover number (TON) reached up to 8×106, which is the highest TON for the oxidation systems of sulfide to sulfone catalyzed by metalloporphyrins.  相似文献   

17.
《Analytical letters》2012,45(12):1857-1867
Abstract

A new flexible minisensor based on MnO2/graphite/epoxy resin composite for the potentiometric determination of hydrogen peroxide was developed in this work. Under optimum experimental conditions, such as 25°C, 4 h of conditioning time in 0.1 mol L?1 NH3‐NH4 + buffer solution (pH 8.5) and a composition of 10/60/30% w/w MnO2/graphite/epoxy resin, respectively, the minisensor presented a Nernstian response for H2O2 in the concentration range from 6.0×10?7 to 1.0×10?3 mol L?1, with a slope of ?58.5±0.2 mV/pH2O2 with a detection limit of 1.6×10?8 mol L?1 H2O2. The useful lifetime of the proposed minisensor was at least 6 months (over 670 determinations for each composite), the response time was smaller than 1.5 min, and it was successfully applied in the determination of hydrogen peroxide in bleach and pharmaceutical products.  相似文献   

18.
WANG  Guiling  ZHANG  Weicai  CAO  Dianxue  LIU  Jincheng  WANG  Xunying  ZHANG  Sen  SUN  Kening 《中国化学》2009,27(11):2166-2170
The effects of hot alkaline treatment and Fe2O3 modification of hydrogen storage alloy on the electrocatalytic activity for oxidation of borohydride have been investigated using linear sweep voltammetry. The performance of borohydride electrochemical oxidation was significantly influenced by the hot alkaline treatment and Fe2O3 modification of the hydrogen storage alloy. The results showed that the current density of the Fe2O3‐modified hot alkaline‐treated hydrogen storage alloy electrode containing 5 wt% Fe2O3 reached 125 mA·cm?2 in 0.10 mol·L?1 NaBH4 and 2 mol·L?1 NaOH solution at ?0.55 V vs. saturated Ag/AgCl, KCl electrode.  相似文献   

19.

Silver nanoparticles enhanced glucose oxidase electrodes were prepared on the basis of chitosan matrix. The enzyme electrodes exhibited high sensitivity and excellent response performance to glucose with a linear range from 1×10?6 to 8×10?3 mol · L?1. And the time reaching the steady‐state amperometric response was less than 5 seconds. The inhibition percentage of this enzyme electrode against copper ions concentration was linear ranging from 1.2×10?6 to 5×10?5 mol · L?1. These properties of enzyme electrodes are probably due to the excellent electron transfer of silver nanoparticles and the orientation of glucose oxidase molecule.  相似文献   

20.
The kinetic method for the determination of phosphate microamounts was described. The developed method is based on catalytic effect of phosphate on sodium pyrogallol-5-sulphonate (PS) by dissolved oxygen. The reaction was followed spectrophotometrically by measuring the rate of change in the values of the absorbance of the oxidation product at 437 nm. The optimum reaction conditions are PS (0.44×10^-3 mol·L^-1) and HClO4 (3.6×10^-6 mol·L^-1) at 25 ℃. Following this procedure, phosphate can be determined with a linear calibration graph up to 0.23 μg·mL^-1. The interference effect of several species was also investigated and it was found that the most common cations and anions did not interfere with the determination. The developed procedure was successfully applied to the determination of phosphate in natural waters and soil.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号