首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Characteristic aroma compounds in plants and essential oils of Lavandula from different varieties were examined. The study of the qualitative and quantitative composition of the major volatile components was faced by developing a method based on the use of supercritical fluid extraction-GC-MS (SFE-GC-MS). The optimization of a variety of parameters affecting SFE extraction enabled RSDs from three replicates lower than 2% to be achieved. Equally, recoveries of up to 59% were obtained by applying the proposed method. The use of multidimensional GC was necessary to enantiomerically resolve the target compounds. The obtained results showed enantiomeric purities >90% for all studied compounds in all varieties considered, proving the natural invariability of the enantiomeric composition of the compounds of interest. This information can be useful in authenticity studies as well as in selecting natural sources of enantiomerically pure compounds.  相似文献   

2.
Synthesis of the enantiomeric 2-pyrrolidineacetic acids. Starting from the enantiomeric Z-prolines ( 1 ) the title compounds 9 were prepared in optically pure form by using the Arndt-Eistert process. It could be shown by chemical correlation that the stereochemical determining step of the reaction sequence, the Wolff rearrangement of the N-acylated diazomethyl ketones 5 , proceeds with strict retention of configuration. Some known chiroptical methods for determination of absolute configuration were applied to the target compounds.  相似文献   

3.
Comprehensive two-dimensional gas chromatography with micro electron-capture detection (GC x GC-microECD) has been evaluated for the enantioseparation of five chiral toxaphenes typically found in real-life samples (Parlar 26, 32, 40, 44 and 50). From the two enantioselective beta-cyclodextrin-based columns evaluated as first dimension column, BGB-176SE and BGB-172, the latter provided the best results and was further combined with three non-enantioselective columns in the second dimension: HT-8, BPX-50 and Supelcowax-10. The combination BGB-172 x BPX-50 was finally selected because it provided a complete separation among all enantiomers. A satisfactory repeatability and reproducibility of the retention times in both the first and the second dimension were observed for all target compounds (RSDs below 0.8%, n = 4). Linear responses in the tested range of 10-200 pg/microl and limits of detection in the range of 2-6 pg/microl were obtained. The repeatability and reproducibility at a concentration of 100 pg/microl, evaluated as the RSDs calculated for the enantiomeric fraction (EF), was better than 11% (n = 4) in all instances. The feasibility of the method developed for real-life analyses was illustrated by the determination of the enantiomeric ratios and concentration levels of the test compounds in four commercial fish oil samples. These results were compared to those obtained by heart-cut multidimensional gas chromatography using the same enantioselective column.  相似文献   

4.
A novel polysaccharide-based chiral stationary phase (CSP), cellulose tris(3-chloro-4-methylphenylcarbamate), also known as Sepapak-2 or Lux Cellulose-2, has been evaluated for the enantiomeric separation of FMOC derivatives of amino acids. After mobile-phase optimization in nano liquid chromatography (nano-LC) the column enabled the enantiomeric separation of 19 out of 23 amino acids tested, indicating the high chiral recognition power of this new CSP. Subsequently, a comparison of the driving force employed (pressure or voltage) was carried out comparing nano-LC and CEC under the same conditions. Better peak efficiencies and resolution were observed by using CEC experiments, which enabled the chiral discrimination of 20 out of 23 amino acids tested. Finally, in order to show the potential of this new CSP, the determination of the content and the enantiomeric purity of the non-protein amino acid citrulline in food supplements was performed. For that purpose, the method was optimized, evaluated and applied to different commercial samples.  相似文献   

5.
The enantiomers of two acylamine fungicides (metalaxyl and benalaxyl) were separated by EKC using CDs as chiral selectors. The use of 15 mM succinyl-γ-CD for metalaxyl and 5 mM succinyl-β-CD for benalaxyl dissolved in a 50 mM 2-morpholinoethanesulfonic acid buffer (pH 6.5), enabled the chiral separation of metalaxyl enantiomers in 11.5 min with a resolution of 3.1 and the enantiomeric separation of benalaxyl in 7.5 min with a resolution close to 15. Under these conditions, the two enantiomers of each of the chiral compound studied were also separated from folpet, very commonly present in fungicide formulations containing metalaxyl or benalaxyl. The analytical characteristics of the two developed methods were studied in terms of precision, linearity, selectivity, limits of detection (LODs) and limits of quantitation (LOQs) showing their suitability for the determination of these compounds in commercial agrochemical formulations. Finally, the development of an in-capillary preconcentration strategy allowed the detection of enantiomeric impurities up to 1.2% in commercial products labeled as enantiomerically pure in metalaxyl-M.  相似文献   

6.
A quality assessment method for commercially available, optically active flavor compounds, namely, menthol, menthyl acetate, borneol, perillaldehyde, and 1,8-cineol, was developed. A gas chromatograph equipped with a flame ionization detector and a DB-5ms capillary column was used for the chemical purity test. A GC/MS with a beta-DEX cyclodextrin column was used for the optical purity test, by which the enantiomeric separation of each flavor compound was achieved. Enantiomeric excess was calculated as an expression of optical purity. Of the 25 standard samples subjected to the chemical purity test, six were found to have lower purity than the data provided by the manufacturers. When the same samples were subjected to the optical purity test, 11 were found to have lower purity than that indicated on the reagent labels. These results suggest that there is a need to conduct an optical purity test, in addition to a chemical purity test, for the quality assessment of flavor standards.  相似文献   

7.
马慧莲  金静  李云  陈吉平 《色谱》2017,35(10):1094-1099
建立了固相吸附热脱附-气相色谱-质谱(TD-GC-MS)综合筛查工业源废气中挥发性有机物(VOCs)的方法。对两种型号的固相吸附管进行了比较,最终选择使用Tenax SS TD Tubes吸附管。气体样品以恒定流速通过吸附管,富集分析物,经热脱附后,用GC-MS进行检测,目标化合物以内标法定量,非目标化合物的含量以甲苯的响应系数计算。方法检出限为1.06~5.44 ng,以采样体积300 mL计算,目标化合物的检出限为0.004~0.018 mg/m~3。吸附管平均加标回收率为78.4%~89.4%,相对标准偏差为3.9%~14.4%(n=7)。应用该方法对大连市某垃圾焚烧发电厂排放的废气进行VOCs目标及非目标化合物综合筛查,共检出29种VOCs,其中仅5种VOCs为预先设定的目标化合物,另外24种为非目标化合物,5种目标化合物含量仅占所有检出物总量的26.7%。证明了工业源废气VOCs分析中非目标化合物筛查的重要性,该研究思路对完整测定工业源挥发性有机污染物分布具有一定的借鉴意义。  相似文献   

8.
This work explores the self‐disproportionation of enantiomers (SDE) via achiral, gravity‐driven column chromatography as typically used in laboratory settings for the purpose of enantiomeric enrichment using N‐(1‐phenylethyl)acetamide (PEA) as a case study. The major finding of this work is the very large magnitude of the SDE for PEA across a variety of conditions and broad range of starting ee values, thereby facilitating a simple, reliable, and predictable means of obtaining enantiomerically pure samples. For example, starting with a sample of PEA of ee as low as 28%, a single column run yielded an enantiomerically pure sample (>99.9% ee) from the first fractions and a significantly enantiomerically depleted sample (<17% ee) from the final fractions. An assessment of SDE via achiral, gravity‐driven column chromatography was also rendered with regard to the differing objectives that workers might target – a large magnitude of the SDE, obtaining an optimum sample of desired ee, or preparative‐scale separation of the excess enantiomer. Overall, it can be considered that the SDE phenomenon via achiral, gravity‐driven column chromatography – readily applicable in the usual laboratory settings – is a simple and convenient method for enantiomeric enrichment with a high degree of proficiency. Advantages of SDE via achiral, gravity‐driven column chromatography over conventional fractional recrystallization for the enantiomeric enrichment of amides/amines, and applicable also to many other classes of compounds as well, are discussed.  相似文献   

9.
A headspace solid-phase microextraction (HS-SPME) procedure based on three commercialised fibers (100 microm polydimethylsiloxane, 65 microm polydimethylsiloxane-divinylbenzene and 50/30 microm divinylbenzene-Carboxen-polydimethylsiloxane) is presented for the determination of a selected essential oils in dried leaves of yacon (Smallanthus sonchifolius). The extraction performances of these compounds were compared using fibers with one, two and three coatings. The optimal experimental procedures for the adsorption and desorption of target compounds were determined. Significant parameters affecting sorption process such as sample weight, sorption and desorption time and temperature were optimised and discussed. Finally, the optimised procedures were applied successfully for the determination of these compounds in various yacon species. The relative concentration factors of three characteristic components of yacon were measured for relative evaluation of the fiber efficiency. Main essential oils were isolated from dried yacon leaves by appropriate solid-phase microextraction fiber and semi-quantitative analysis of the target volatiles was conducted by gas chromatography-flame ionisation detection (GC-FID) using a capillary column. Three compounds--beta-pinene, caryophylene and y-cadinene were found as the predominant essential oils. Its relative content was important for specification of yacon varieties. Solid-phase microextraction in combination with gas chromatography enabled a rapid and simple determination of relative content of essential oils in yacon.  相似文献   

10.
The present research is focused on the determination of the enantiomeric distribution of chiral compounds, contained in mandarin essential oils, by means of conventional chiral gas chromatography with flame ionization detection (enantio-GC-FID); the results attained were compared with those derived from heart-cutting multidimensional GC-mass spectrometry (MDGC/MS), to evaluate the reliability of the monodimensional technique as a tool for quality control. The Deans-switch MDGC system was equipped with two GC ovens, which were connected via a heated transfer line, a flame ionization detector (FID1) in the first dimension and a quadrupole MS as second-dimension detector. The a priori knowledge of potential co-elutions concerning target compounds (an enantiomer and an interfering compound), when using enantio-GC-FID, could enable the use of corrected enantiomer excess values. Correction factors could be calculated through a preliminary GC-FID analysis (using an apolar column), considering the peak areas of the known interferences. The method used for the calculation of a so-called “coelution correction factor” is described, along with some examples.  相似文献   

11.
High-performance liquid chromatography (HPLC) in both chiral isocratic and achiral-chiral column switching mode was employed for optimization of separation conditions, separation and determination of fungicide epoxiconazole in real samples. Two enantiomers of commercially available triazole fungicide epoxiconazole (BAS 480 F), first registered in 1993, were resolved for the first time on a microcrystalline cellulose triacetate (MCTA). A low-cost home-packed chiral column (150x3 mm, 15-25 microm, MCTA, Merck) enabled baseline enantiomeric resolution of two enantiomers of the fungicide epoxiconazole produced commercially. The effects of concentration of organic modifiers (methanol, ethanol) in mobile phase, flow-rate and temperature were studied. The isocratic chiral HPLC method allows determination of the enantiomers in tap and surface water within the range 1-1000 mg/l by direct injection (20 microl) of the sample. Using the achiral (C18)-chiral (MCTA) column-switching technique and 1-ml sample volume, injection of 0.050 mg/l of epoxiconazole enantiomers can be conveniently determined by UV detection at 230 nm. The same method applied to methanolic soil extracts allows determination of 0.2 mg/kg of epoxiconazole enantiomers in addition to the other 10 commonly used pesticides in fortified soils.  相似文献   

12.
A validated two-dimensional HPLC system combining a microbore-monolithic ODS column and a narrowbore-enantioselective column has been established for a sensitive and simultaneous analysis of hydrophilic amino acid enantiomers (His, Asn, Ser, Gln, Arg, Asp, allo-Thr, Glu and Thr) and the non-chiral amino acid, Gly, in biological samples. To accomplish this goal, the amino acids were first tagged with 4-fluoro-7-nitro-2,1,3-benzoxadiazole (NBD-F) to the respective fluorescent NBD derivatives which were separated in the first dimension by a micro-reversed-phase column. The automatically collected fractions of the target peaks were then transferred to the second dimension consisting of a Pirkle type enantioselective column generating separation factors higher than 1.13 for all the enantiomeric target analytes. The system was validated using standard amino acids and a rat plasma sample, and analytically satisfactory calibration and precision results were obtained. The present 2D-HPLC system enables the fully automated determination of hydrophilic amino acid enantiomers in mammalian samples. The d-isomers of all the investigated 9 amino acids were found in rat urine but at various enantiomeric ratios.  相似文献   

13.
For the first time, enrichment on solid sorbents followed by thermal desorption has been used for the determination of the enantiomeric signature of monoterpenes in the gaseous emission of terrestrial plants. A beta-cyclodextrin capillary column has been used for the separation of critical pairs. The temperature program and column loading were optimized for making the accurate quantification of individual enantiomers possible by mass spectrometry. The resolution achieved was sufficient for separating enantiomeric monoterpenes from other biogenic and anthropogenic volatile organic compounds present in air and vegetation emission samples. The method has been applied to the determination of the enantiomeric ratios of monoterpenes in the gaseous emissions of some evergreen plants and in the open atmosphere.  相似文献   

14.
In this work the enantiomeric distribution of chiral coumarins (meranzin and epoxyaurapten), and furocoumarins (oxypeucedanin, byakangelicol, and epoxybergamottin) in different Citrus essential oils (lemon, lime, grapefruit, and bitter orange) was determined by means of a heart-cutting multidimensional-liquid chromatography (MD-LC) system, equipped with a microsilica column in the first dimension in a combination to a cellulosic-based chiral column used in the second dimension. The normal phase-liquid chromatography-liquid chromatography (NP-LC-LC) instrumentation was equipped with a photodiode array detector and a multiport valve as interface. For method optimization and the determination of absolute configuration, natural compounds were isolated and racemic mixture was synthesized. The NP-LC-LC/PDA (where PDA is photodiode array) method provided a good baseline separation of chiral coumarins (meranzin and epoxyaurapten) and furocoumarins (epoxybergamottin and byakangelicol) present in cold-pressed Citrus essential oils without any sample pretreatment. Results obtained showed that for all the chiral compounds present in Citrus essential oils analyzed, there is always a clear prevalence of one of the two enantiomers, and do not appear influenced by the different geographical origin of the oils.  相似文献   

15.
A high-performance liquid chromatographic method for the simultaneous determination of both enantiomers of naproxen and its metabolite 6-O-desmethylnaproxen has been developed. The separation is performed on a column containing alpha 1-acid glycoprotein as the chiral selector. The method has been used for the determination of the enantiomeric purity of the drug substance and the metabolite, and for the simultaneous determination of all four compounds in biological fluids.  相似文献   

16.
Summary The direct enantiomeric resolution of five O-aryl O-alkyl N-alkyl-phosphoramidothioates was carried out and their pure enantiomers were prepared on a commercially available Pirkle model chiral column (OA-4700). Absolute configurations of the enantiomers were determined by circular dichroism (CD) spectroscopy. S-enantiomers were the first compounds to elute chromatographically and the chromatographic elution order was in accordance with the results of computer simulating calculation. The biological activity test suggested that all the S-enantiomers were more active than R-enantiomers in killing barnyard grass.  相似文献   

17.
刘通  王玉娇  王秀娟  崔东伟  张峰 《色谱》2019,37(11):1215-1220
建立了气相色谱-三重四极杆质谱(GC-MS/MS)同时检测巴氏杀菌乳中9种香精成分(二氢香豆素、香兰素、香豆素、乙基香兰素、甲基香兰素、7-甲基香豆素、7-甲氧基香豆素、7-乙氧基-4甲基香豆素和环香豆素)的分析方法。巴氏杀菌乳样品用乙醇溶液萃取,低温涡旋离心,取上清液过0.22 μm滤膜,以DB-5MS色谱柱分离,在MRM模式下测定,基质曲线外标法定量。实验结果表明,9种香精成分在1~200 μg/L范围内呈良好线性,线性相关系数(R2)均大于0.997,方法的检出限为0.002~0.1 μg/kg,定量限为0.001~2 μg/kg,平均回收率为90.3%~110.6%,日内、日间精密度均小于10%。该方法前处理简单快速,检测准确度和灵敏度高,可用于巴氏杀菌乳中9种香精成分的同时检测。  相似文献   

18.
The known HPLC method using an achiral C8 silica sorbent and a circular dichroism (CD) detector for the determination of efaroxan enantiomeric excess has been validated. After optimization of the mobile phase, the enantiomers were detected at 278 nm offering maximum ellipticity between two optically active forms. The calibration curve of the anisotropy factor (g) versus the enantiomeric excess was linear with a correlation coefficient (r2) of 0.9985. The accuracy of the method was assessed by comparing the enantiomeric excess obtained by measuring the g factor (C8 column, CD and UV detections) with those determined by enantioselective HPLC (Chiralpak AD-H column, UV detection). Statistical tests (level of confidence of 95%) were assessed to compare the two orthogonal methods. The straight line gave a correlation coefficient of 0.9995, an intercept not significantly different from zero (0.0549) and a slope of 1.026. The precision evaluated on retention time (RSD<0.6%), g factor (RSD<8.3%) and CD peak area (RSD<7.5%) was suitable both in term of intra- and inter-day precisions. The proposed method has the advantages of being fast and precise without using expensive chiral column. Non-enantioselective HPLC-CD was suitable for the simultaneous determination of the optical and chemical purity of efaroxan.  相似文献   

19.
This is the third part of a three‐part series of papers. In Part I, we presented a method for determining the actual effective geometry of a reference column as well as the thermodynamic‐based parameters of a set of probe compounds in an in‐house mixture. Part II introduced an approach for estimating the actual effective geometry of a target column by collecting retention data of the same mixture of probe compounds on the target column and using their thermodynamic parameters, acquired on the reference column, as a bridge between both systems. Part III, presented here, demonstrates the retention time transfer and prediction from the reference column to the target column using experimental data for a separate mixture of compounds. To predict the retention time of a new compound, we first estimate its thermodynamic‐based parameters on the reference column (using geometric parameters determined previously). The compound's retention time on a second column (of previously determined geometry) is then predicted. The models and the associated optimization algorithms were tested using simulated and experimental data. The accuracy of predicted retention times shows that the proposed approach is simple, fast, and accurate for retention time transfer and prediction between gas chromatography columns.  相似文献   

20.
The feasibility of comprehensive two-dimensional gas chromatography with electron-capture detection (GC x GC-ECD) for the enantioseparation of chiral PCBs from other possible interfering compounds has been evaluated. Three commercially available enantioselective beta-cyclodextrin-based capillary columns (Chirasil-Dex, BGB-172 and BGB-176SE) have been tested as first-dimension columns. Three non-enantioselective stationary phases (HT-8, BPX-50 and Supelcowax-10) were combined with the enantioselective columns to allow the unambiguous determination of the enantiomers of the target chiral PCBs. Each enantioselective first-dimension column tested was able to separate into enantiomers different PCB congeners, but in all cases, the use of Supelcowax-10 as second-dimension column provided the most satisfactory results. The Chirasil-Dex x Supelcowax-10 column combination allowed the determination of the enantiomeric fraction (EF) of PCBs 84, 91, 95, 132, 136, 149, 174 and 176 in the working standard solution, while that of congener 135 was hindered. The BGB-172 x Supelcowax-10 column set allowed a proper EF determination of congeners 45, 84, 131, 132, 135, 171, 174 and 183, while that of PCB 91 was interfered with co-elutants. The column combination BGB-176SE x Supelcowax-10 allowed the determination of all congeners that this enantioselective stationary phase was able to separate into enantiomers, i.e. PCBs 45, 91, 95, 136, 149 and 176. These column combinations have also been evaluated for the simultaneous determination of the 12 congeners with a toxic equivalency factor assigned by the WHO (PCBs 77, 81, 105, 114, 118, 123, 126, 156, 157, 167, 169, 189) and the seven indicator congeners (PCBs 28, 52, 101, 118, 138, 153 and 180), and evaluated for the analysis of food samples.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号