首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
系统地比较了3种常用的离子化技术电喷雾电离(ESI)、大气压化学电离(APCI)、大气压光致电离(APPI)对脂类化合物的离子化效率、检测灵敏度和覆盖范围,以探讨多重离子化液相色谱-质谱(LC-MS)方法在血清脂质组学研究中的适用性.血清样本经甲基叔丁基醚萃取后,采用Ascentiss Express C8 色谱柱(150 mm×2.1 mm, 2.7 μm)和二元线性梯度洗脱分离,流动相(A)为乙腈-水(3∶2, V/V, 含0.1%甲酸, 10 mmol/L甲酸铵),B为异丙醇-乙腈(9∶1, V/V, 含0.1%甲酸,10 mmol/L甲酸铵),分别采用ESI、APCI和APPI离子源正、负离子模式进行质谱检测.结果表明,ESI离子源对脂肪酸类、甘油脂类、甘油磷脂类化合物、鞘磷脂类化合物的离子化效率最高,对异戊烯醇脂类化合物的离子化效率与APPI离子源相当,APPI离子源对胆固醇(酯)类化合物的检测灵敏度最高,APCI离子源对各类化合物的检测灵敏度均低于ESI或APPI离子源;采用ESI和APPI离子源相结合的LC-MS脂质组学分析方法可以提高分析方法的整体灵敏度和血清中脂类信息检测的完整性.  相似文献   

2.
Although the coupling of GC/MS with atmospheric pressure ionization (API) has been reported in 1970s, the interest in coupling GC with atmospheric pressure ion source was expanded in the last decade. The demand of a “soft” ion source for preserving highly diagnostic molecular ion is desirable, as compared to the “hard” ionization technique such as electron ionization (EI) in traditional GC/MS, which fragments the molecule in an extensive way. These API sources include atmospheric pressure chemical ionization (APCI), atmospheric pressure photoionization (APPI), atmospheric pressure laser ionization (APLI), electrospray ionization (ESI) and low temperature plasma (LTP). This review discusses the advantages and drawbacks of this analytical platform. After an introduction in atmospheric pressure ionization the review gives an overview about the history and explains the mechanisms of various atmospheric pressure ionization techniques used in combination with GC such as APCI, APPI, APLI, ESI and LTP. Also new developments made in ion source geometry, ion source miniaturization and multipurpose ion source constructions are discussed and a comparison between GC-FID, GC-EI-MS and GC-API-MS shows the advantages and drawbacks of these techniques. The review ends with an overview of applications realized with GC-API-MS.  相似文献   

3.
In this paper we describe results based on the combination of atmospheric pressure photoionization (APPI) with atmospheric pressure chemical ionization (APCI) and electrospray ionization (ESI). The main purpose of combining more than one ionizer is to extend the range of compounds that can be simultaneously analyzed. Three modes of operation are presented; use of either ionizer, simultaneous use of two ionizers, and rapid switching between ionizers during a single chromatographic run. The dual ionizer configurations only minimally affect the performance of either ionizer relative to the standard single-ionizer sources. However, it is observed that the operation of both ionizers together does not typically give the sum signal from either source operating alone. For APCI/APPI the signal can range from less than that of either source alone to the sum of the two individual sources. For ESI/APPI, we observed large suppressions of the ESI multiply-charged signal of proteins when the APPI source was on. These behaviors are presumed to be due to the interaction of the initially formed ions by both sources and attests to the importance of ion-molecule reactions that occur during and after the primary ionization events. We give examples of compounds that are preferentially ionized by either APPI, APCI or ESI and present thermochemical arguments based on molecular structure and functionality to explain this behavior. The dual source is also shown to be able to operate in negative ion mode opening up the potential to conduct wide ranging chemical analyses.  相似文献   

4.
A method for the determination of polymer additives like antioxidants, UV absorbers and processing stabilizers using liquid chromatography (LC) coupled with atmospheric pressure photoionization mass spectrometry (APPI-MS) is presented. Ion source parameters were optimized regarding temperatures, gas flow rates, and voltages applied. Detection limits were determined using APPI with or without dopant and were compared with electrospray ionization (ESI) and atmospheric pressure chemical ionization (APCI). Differences between APPI, ESI and APCI are pointed out and the effect of the dopant toluene and acetone is discussed. The optimized method yielded detection limits between 0.001 mg L−1 and 0.022 mg L−1 for 15 different analytes. Linear calibration plots could be obtained for all solutes over a wide concentration range showing satisfying repeatability with standard deviations of peak areas between 3.4% and 7.6%. The results indicate that the developed method can be regarded as suitable for the quantitative determination of polymer additives even at low concentration levels.  相似文献   

5.
Accurate measurement of estradiol (E2) is important in clinical diagnostics and research. High sensitivity methods are critical for specimens with E2 concentrations at low picomolar levels, such as serum of men, postmenopausal women and children. Achieving the required assay performance with LC–MS is challenging due to the non‐polar structure and low proton affinity of E2. Previous studies suggest that ionization has a major role for the performance of E2 measurement, but comparisons of different ionization techniques for the analysis of clinical samples are not available. In this study, female serum and endometrium tissue samples were used to compare electrospray ionization (ESI), atmospheric pressure chemical ionization (APCI) and atmospheric pressure photoionization (APPI) in both polarities. APPI was found to have the most potential for E2 analysis, with a quantification limit of 1 fmol on‐column. APCI and ESI could be employed in negative polarity, although being slightly less sensitive than APPI. In the presence of biological background, ESI was found to be highly susceptible to ion suppression, while APCI and APPI were largely unaffected by the sample matrix. Irrespective of the ionization technique, background interferences were observed when using the multiple reaction monitoring transitions commonly employed for E2 (m/z 271 > 159; m/z 255 > 145). These unidentified interferences were most severe in serum samples, varied in intensity between ionization techniques and required efficient chromatographic separation in order to achieve specificity for E2. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

6.
Ivano Marchi 《Talanta》2009,78(1):1-610
This review presents the state-of-the-art techniques that couple liquid chromatography (LC) and mass spectrometry (MS) via atmospheric pressure photoionization (APPI). The different ionization mechanisms are discussed as well as the influence of the mobile phase composition, the nature of the dopant, etc. A comparison with other ionization sources, such as electrospray ionization (ESI) and atmospheric pressure chemical ionization (APCI), is reported, and the combination of APPI with these sources is also discussed. Several applications, covering the time period of 2005-2008, for the analysis of drugs, lipids, natural compounds, pesticides, synthetic organics, petroleum derivatives, and other substances are presented.  相似文献   

7.
The performance of the atmospheric pressure photoionization (APPI) technique was evaluated against five sets of standards and drug-like compounds and compared to atmospheric pressure chemical ionization (APCI) and electrospray ionization (ESI). The APPI technique was first used to analyze a set of 86 drug standards with diverse structures and polarities with a 100% detection rate. More detailed studies were then performed for another three sets of both drug standards and proprietary drug candidates. All 60 test compounds in these three sets were detected by APPI with an overall higher ionization efficiency than either APCI or ESI. Most of the non-polar compounds in these three sets were not ionized by APCI or ESI. Analysis of a final set of 201 Wyeth proprietary drug candidates by APPI, APCI and ESI provided an additional comparison of the ionization techniques. The detection rates in positive ion mode were 94% for APPI, 84% for APCI, and 84% for ESI. Combining positive and negative ion mode detection, APPI detected 98% of the compounds, while APCI and ESI detected 91%, respectively. This analysis shows that APPI is a valuable tool for day-to-day usage in a pharmaceutical company setting because it is able to successfully ionize more compounds, with greater structural diversity, than the other two ionization techniques. Consequently, APPI could be considered a more universal ionization method, and therefore has great potential in high-throughput drug discovery especially for open access liquid chromatography/mass spectrometry (LC/MS) applications.  相似文献   

8.
Metal salen complexes are one of the most frequently used catalysts in enantioselective organic synthesis. In the present work, we compare a series of ionization methods that can be used for the mass spectral analysis of two types of metalosalens: ionic complexes (abbreviated as Com+X?) and neutral complexes (NCom). These methods include electron ionization and field desorption (FD) which can be applied to pure samples and atmospheric pressure ionization techniques: electrospray ionization (ESI), atmospheric pressure chemical ionization (APCI) and atmospheric pressure photoionization (APPI) which are suitable for solutions. We found that FD is a method of choice for recording molecular ions of the complexes containing even loosely bonded ligands. The results obtained using atmospheric pressure ionization methods show that the results depend mainly on the structure of metal salen complex and the ionization method. In ESI spectra, Com+ ions were observed, while in APCI and APPI spectra both Com+ and [Com + H]+ ions are observed in the ratio depending on the structure of the metal salen complex and the solvent used in the analysis. For complexes with tetrafluoroborate counterion, an elimination of BF3 took place, and ions corresponding to complexes with fluoride counterion were observed. Experiments comparing the relative sensitivity of ESI, APCI and APPI (with and without a dopant) methods showed that for the majority of the studied complexes ESI is the most sensitive one; however, the sensitivity of APCI is usually less than two times lower and for some compounds is even higher than the sensitivity of ESI. Both methods show very high linearity of the calibration curve in a range of about 3 orders of magnitude of the sample concentration. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

9.
Only five years after the first publication on atmospheric pressure photoionization (APPI), this technique has evolved rapidly as a very useful complement to established ionization techniques for liquid chromatography/mass spectrometry (LC/MS). This is reflected in a rapidly increasing number of publications in this field. On the one hand, thorough studies into the photoionization mechanism have provided deep insights into the roles and influences of the solvent, the dopant and other additives. On the other hand, a large number of new and attractive applications have recently been introduced. New instrumental developments have resulted in combined APPI/ESI (PAESI) and APPI/APCI sources and a microfabricated APPI source. In this review, the most important developments within the field are summarized, focusing in particular on the applications of the technique.  相似文献   

10.
The applicability of three different ionization techniques: atmospheric pressure photoionization (APPI), atmospheric pressure chemical ionization (APCI) and electrospray ionization (ESI) was tested for the liquid chromatography-tandem mass spectrometry (LC-MS/MS) analysis of five target pharmaceuticals (cyclophosphamide, methotrexate, bezafibrate, enalapril and orlistat) in wastewater samples. Performance was compared both by flow injection analysis (FIA) and on-column analysis in deionized water and wastewater samples. A column switching technique for the on-line extraction and analysis of water samples was used. For both FIA and on-column analysis, signal intensity and signal-to-noise (S/N) ratio of the target analytes in the three sources were studied. Limits of detection and matrix effects during the analysis of wastewater samples were also investigated. ESI generated significantly larger peak areas and higher S/N ratios than APCI and APPI in FIA and in on-column analysis. ESI was proved to be the most suitable ionization method as it enabled the detection of the five target compounds, whereas APCI and APPI ionized only four compounds.  相似文献   

11.
Gas chromatography/mass spectrometry (GC/MS) is applied to the analysis of volatile and thermally stable compounds, while liquid chromatography/atmospheric pressure chemical ionization mass spectrometry (LC/APCI‐MS) and liquid chromatography/electrospray ionization mass spectrometry (LC/ESI‐MS) are preferred for the analysis of compounds with solution acid‐base chemistry. Because organic explosives are compounds with low polarity and some of them are thermally labile, they have not been very well analyzed by GC/MS, LC/APCI‐MS and LC/ESI‐MS. Herein, we demonstrate liquid chromatography/negative ion atmospheric pressure photoionization mass spectrometry (LC/NI‐APPI‐MS) as a novel and highly sensitive method for their analysis. Using LC/NI‐APPI‐MS, limits of quantification (LOQs) of nitroaromatics and nitramines down to the middle pg range have been achieved in full MS scan mode, which are approximately one order to two orders magnitude lower than those previously reported using GC/MS or LC/APCI‐MS. The calibration dynamic ranges achieved by LC/NI‐APPI‐MS are also wider than those using GC/MS and LC/APCI‐MS. The reproducibility of LC/NI‐APPI‐MS is also very reliable, with the intraday and interday variabilities by coefficient of variation (CV) of 0.2–3.4% and 0.6–1.9% for 2,4,6‐trinitrotoluene (2,4,6‐TNT). Copyright © 2008 John Wiley & Sons, Ltd.  相似文献   

12.
A novel ion/molecule reaction was observed to occur under electrospray ionization (ESI), atmospheric pressure chemical ionization (APCI), and atmospheric pressure photo ionization (APPI) conditions, leading to dimerization of ionized 4‐(methyl mercapto)‐phenol followed by fast H· loss. The reaction is particularly favored during ESI, which suggests that this ion/molecule reaction can occur both in the solution inside the ESI‐charged droplets and in the gas‐phase environment of most other atmospheric pressure ionization techniques. The dimerization reaction is inherent to the electrolytic process during ESI, whereas it is more by ion/molecule chemistry in nature during APCI and APPI. From the tandem mass spectrometry (MS/MS) data, accurate mass measurements, hydrogen/deuterium (H/D) exchange experiments and density functional theory (DFT) calculations, two methyl sulfonium ions appear to be the most likely products of this electrophilic aromatic substitution reaction. The possible occurrence of this unexpected reaction complicates mass spectral data interpretation and can be misleading in terms of structural assignment as reported herein for 4‐(methyl mercapto)‐phenol. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

13.
Atmospheric pressure photoionization (APPI) is a novel method of ionization in liquid chromatography/mass spectrometry (LC/MS). It was originally developed in order to broaden the range of LC/MS ionizable compounds towards less polar compounds that cannot be analyzed by electrospray (ESI) and atmospheric pressure chemical ionization (APCI). Studies done thus far have shown that non-polar compounds that earlier were not ionizable in LC/MS can indeed be ionized by the use of APPI. However, the best ionization efficiency for low polarity samples has been achieved with low proton affinity (PA) solvents that are not suitable in reversed-phase LC (RP-LC). Here it is demonstrated that the signals for analytes with low proton affinities in acetonitrile can be increased 100-fold by using anisole as the dopant for APPI, which takes the sensitivity to the same level achieved in the analysis of high PA analytes.  相似文献   

14.
This study compared the sensitivities and matrix effects of four ionization modes and four reversed-phase liquid chromatographic (LC) systems on analyzing estrone (E1), 17β-estradiol (E2), estriol (E3), 17α-ethinylestradiol (EE2), 4-nonylphenol (NP), 4-tert-octylphenol (OP), bisphenol A (BPA) and their derivatives of dansyl chloride or pentafluorobenzyl bromide (PFBBr) in water matrixes using a triple-quadrupole mass spectrometer with selected reaction monitoring (SRM). The four probes were electrospray ionization (ESI), atmospheric pressure chemical ionization (APCI), atmospheric pressure photoionization (APPI) and APCI/APPI; the four LC systems were ultra-performance liquid chromatography (UPLC) with or without post-column split, a mixed-mode column and two-dimensional LC (2D-LC). Dansylated compounds with ESI at UPLC condition had the most intense signals and less matrix effects of the various combinations of ionization and LC systems. The on-column limits of detection (LODs) of dansylated estrogens by SRM were 0.05–0.20 pg, and the LODs in sewage treatment plant effluent and in river water were 0.23–0.52 and 0.56–0.91 ng/L, respectively. The LODs using selected ion monitoring (SIM) reached low ng/L levels in real samples and measured concentrations were comparable with those of SRM.  相似文献   

15.
Analysis of 11 polybrominated diphenyl ethers (PBDEs), tetrabromobisphenol A bis 2,3-dibromopropylether (TBBPA-bis), tetrachlorobisphenol A (TCBPA), tetrabromobisphenol A (TBBPA) and hexabromocyclododecanes (HBCDs) was optimized by ultrahigh pressure liquid chromatography/tandem mass spectrometry (UPLC–MS/MS) operating in negative ion (NI) mode. Electrospray ionization (ESI), atmospheric pressure photoionization (APPI) and atmospheric pressure chemical ionization (APCI) sources were tested and for PBDEs APCI gave higher sensitivity than APPI while for TBBPA-bis APCI and APPI showed similar performance. ESI was the best option for TCBPA, TBBPA and HBCDs. Detection limits were between 20 and 59 fg for the compounds analyzed by ESI, 0.10 and 0.72 pg for PBDEs and 6 pg for TBBPA-bis. The matrix effect of sewage sludge extract was also tested showing negligible ion suppression for APCI and an increase of the background level of all investigated pollutants leading to a worsening of the limits of quantification by a factor between 1.2 and 3.3. The UPLC-APCI/MS/MS method for PBDEs, after pressurized liquid extraction (PLE), was validated by comparison with the concentration values from the NIST 1944 standard reference material. The advantages of the methods include low detection limits, PBDE congeners specificity using selected multiple reaction monitoring (MRM) transitions, and the absence of thermal degradation of higher PBDE congeners, especially BDE-209. The methods were applied for the determination of the above reported flame retardants in sewage sludge in order to get more information about the degradation on PBDEs (in particular BDE-209) during municipal wastewater treatments.  相似文献   

16.
The new ionization method, called surface-activated chemical ionization (SACI), was employed for the analysis of fives drugs (morphine, codeine, 6-monoacetylmorphine (6-MAM), benzoylecgonine and cocaine) by ion trap mass spectrometry. The results so obtained have been compared with those achieved by using atmospheric pressure chemical ionization (APCI), no-discharge-APCI and electrospray ionization (ESI) clearly showing that SACI is the most sensible one mainly due to the high ionization efficiency and the lower chemical noise. The performance of SACI in terms of sensitivity and linearity was compared with the sensitivity and linearity obtained using APCI, no-discharge-APCI and ESI, showing that the new SACI approach gives rise to the best results. Then, SACI was used to analyze morphine, codeine, 6-MAM, benzoylecgonine and cocaine in urine samples. After the optimization of the instrumental parameters for a mixture of the standard compounds, eight urine samples were analyzed. They were strongly diluted (1 : 20 and 1 : 100) in order to prevent the chromatographic column damage due to the matrix composition. Furthermore, the diluted urine samples were directly analyzed, without pretreatment, through LC-MS and LC-MS/MS, and the obtained results are reported.  相似文献   

17.
Capillary electrophoresis/mass spectrometry (CE/MS) is predominantly carried out using electrospray ionization (ESI). Recently, atmospheric pressure chemical ionization (APCI) and atmospheric pressure photoionization (APPI) have become available for CE/MS. With the VUV lamp turned off, the APPI source may also be used for CE/MS by thermospray ionization (TSI). In the present study the suitability of ESI, APCI, APPI and TSI for drug impurity profiling by CE/MS in the positive ion mode is evaluated. The drugs carbachol, lidocaine and proguanil and their potential impurities were used as test compounds, representing different molecular polarities. A background electrolyte of 100 mM acetic acid (pH 4.5) provided baseline separation of nearly all impurities from the respective drugs. APPI yielded both even‐ and odd‐electron ions, whereas the other ionization techniques produced even‐electron ions only. In‐source fragmentation was more pronounced with APCI and APPI than with ESI and TSI, which was most obvious for proguanil and its impurities. In general, ESI and TSI appeared the most efficient ionization techniques for impurities that are charged in solution achieving detection limits of 100 ng/mL (full‐scan mode). APPI and APCI showed a lower efficiency, but allowed ionization of low and high polarity analytes, although quaternary ammonium compounds (e.g. carbachol) could not be detected. Largely neutral compounds, such as the lidocaine impurity 2,6‐dimethylaniline, could not be detected by TSI, and yielded similar detection limits (500 ng/mL) for ESI, APPI and APCI. In many cases, impurity detection at the 0.1% (w/w) level was possible when 1 mg/mL of parent drug was injected with at least one of the CE/MS systems. Overall, the tested CE/MS systems provide complementary information as illustrated by the detection and identification of an unknown impurity in carbachol. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

18.
LC-MS has become an invaluable technique for trace analysis of polar compounds in aqueous samples of the environment and in water treatment. LC-MS is of particular importance due to the impetus it has provided for research into the occurrence and fate of polar contaminants, and of their even more polar transformation products. Mass spectrometric detection and identification is most widely used in combination with sample preconcentration, chromatographic separation and atmospheric pressure ionization (API). The focus of the first part of this review is directed particularly toward instruments and method development with respect to their applications for detecting emerging contaminants, microorganisms and humic substances (HS). The current status and future perspectives of 1) mass analyzers, 2) ionization techniques to interface liquid chromatography (LC) with mass spectrometry (MS), 3) methods for preconcentration and separation with respect to their application for water analysis are discussed and examples of applications are given. Quadrupole and ion trap mass analyzers with electrospray ionization (ESI) and atmospheric pressure chemical ionization (APCI) are already applied in routine analysis. Time-of-flight (TOF) mass spectrometers are of particular interest for accurate mass measurements for identification of unknowns. For non-polar compounds, different ionization approaches have been described, such as atmospheric pressure photoionization (APPI), electrochemistry with ESI, or electron capture ionization with APCI. In sample preconcentration and separation, solid phase extraction (SPE) with different non-selective sorbent materials and HPLC on reversed-phase materials (RP-HPLC) play the dominant role. In addition, various on-line and miniaturized approaches for sample extraction and sample introduction into the MS have been used. Ion chromatography (IC), size-exclusion chromatography (SEC), and capillary electrophoresis (CE) are alternative separation techniques. Furthermore, the issues of compound identification, matrix effects on quantitation, development of mass spectral libraries and the topic of connecting analysis and toxicity bioassays are addressed.  相似文献   

19.
Summary Sonic spray ionization (SSI) was compared with atmospheric pressure chemical ionization (APCI) as an interface for liquid chromatography (LC)-mass spectrometry (MS) for the analysis of some local anesthetics. Peaks at [M+H]+ constituted the base peaks for all compounds by both SSI and APCI, except for prilocaine. The sensitivities by SSI for tetracaine, benzoxinate, dibucaine, bupivacaine and mepivacaine were 4–16 times higher than those by APCI; those by SSI for procaine and lidocaine were equivalent to those by APCI. Only for prilocaine was the sensitivity by SSI two times lower than that by APCI. In view of the higher sensitivities obtained for many local anesthetics by SSI, we established a detailed procedure for the assay of these drugs in human plasma and urine by LC-MS with SSI in combination with a diol-bonded silica gel HPLC column that enabled direct injection of crude biological samples without complicated pretreatment. The recoveries, sensitivities, accuracies and precisions were found satisfactory to quantitate them at their therapeutic levels.  相似文献   

20.
A new integrated microchip for liquid chromatography-mass spectrometry (LC-MS) is presented. The chip is made from bonded silicon and glass wafers with structures for a packed LC column channel, a micropillar frit, a channel for optional optical detection, and a heated vaporizer section etched in silicon and platinum heater elements on the glass cover. LC eluent is vaporized and mixed with nebulizer gas in the vaporizer section and the vapor is sprayed out from the chip. Nonpolar and polar analytes can be efficiently ionized in the gas phase by atmospheric pressure photoionization (APPI) as demonstrated with polycyclic aromatic hydrocarbons (PAHs) and selective androgen receptor modulators (SARMs). This is not achievable with present LC-MS chips, since they are based on electrospray ionization, which is not able to ionize nonpolar compounds efficiently. The preliminary quantitative performance of the new chip was evaluated in terms of limit of detection (down to 5 ng mL−1), linearity (r > 0.999), and repeatability of signal response (RSD = 2.6-4.0%) and retention time (RSD = 0.3-0.5%) using APPI for ionization and PAHs as standard compounds. Determination of fluorescent compounds is demonstrated by using laser-induced fluorescence (LIF) for detection in the optical detection channel before the vaporizer section.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号