首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Microanalyzer for biomonitoring lead (Pb) in blood and urine   总被引:1,自引:0,他引:1  
Biomonitoring of lead (Pb) in blood and urine enables quantitative evaluation of human occupational and environmental exposures to Pb. State-of-the-art ICP–MS instruments can only analyze metals in laboratories, resulting in lengthy turnaround times, and they are expensive. In response to the growing need for a metal analyzer capable of on-site, real-time monitoring of trace toxic metals in individuals, we developed a portable microanalyzer based on flow-injection/stripping voltammetry (ASV), and validated the system using rat blood and urine spiked with known amounts of Pb. Fouling of electrodes by proteins often prevents the effective use of electrochemical sensors in biological matrices. Minimization of such fouling was accomplished with suitable sample pretreatment and by establishing turbulent flow of blood and urine containing Pb onto the electrode inside the microanalyzer, which resulted in no apparent electrode fouling even when the samples contained 50% urine or 10% blood by volume. No matrix effect was observed for the voltammetric Pb signals, even when the samples contained 10% blood or 10% urine. The microanalyzer offered linear concentration ranges relevant to Pb exposure levels in humans (0–20 ppb in 10% blood samples, 0–50 ppb in 50% urine samples). The device showed excellent sensitivity and reproducibility; Pb detection limits were 0.44 ppb and 0.46 ppb, and % R.S.D. was 4.9 and 2.4 in 50% urine and 10% blood samples, respectively. It gave similar Pb concentrations in blood and urine to those measured by ICP–MS. It offered high throughput (3 min per sample) and economical use of samples (60 μL per measurement) as well as low reagent consumption (1 μg of Hg per measurement), thus minimizing environmental concerns associated with mercury use. Since it is miniaturized, the microanalyzer is portable and field-deployable. Thus, it shows much promise as the next-generation analyzer for the biomonitoring of toxic metals.  相似文献   

2.
Urine is universally recognized as one of the best non-invasive matrices for biomonitoring exposure to a broad range of xenobiotics, including toxic metals. Detection of metal ions in urine has been problematic due to the protein competition and electrode fouling. For direct, simple, and field-deployable monitoring of urinary Pb, electrochemical sensors employing superparamagnetic iron oxide (Fe3O4) nanoparticles with a surface functionalization of dimercaptosuccinic acid (DMSA) has been developed. The metal detection involves rapid collection of dispersed metal-bound nanoparticles from a sample solution at a magnetic or electromagnetic electrode, followed by the stripping voltammetry of the metal in acidic medium. The sensors were evaluated as a function of solution pH, the binding affinity of Pb to DMSA-Fe3O4, the ratio of nanoparticles per sample volume, preconcentration time, and Pb concentrations. The effect of binding competitions between the DMSA-Fe3O4 and urine constituents for Pb on the sensor responses was studied. After 90 s of preconcentration in samples containing 25 vol.% of rat urine and 0.1 g L(-1) of DMSA-Fe3O4, the sensor could detect background level of Pb (0.5 ppb) and yielded linear responses from 0 to 50 ppb of Pb, excellent reproducibility (%RSD of 5.3 for seven measurements of 30 ppb Pb), and Pb concentrations comparable to those measured by ICP-MS. The sensor could also simultaneously detect background levels (<1 ppb) of Cd, Pb, Cu, and Ag in river and seawater.  相似文献   

3.
Electrochemical sensors have great potential for environmental monitoring of toxic metal ions in waters due to their portability, field-deployability and excellent detection limits. However, electrochemical sensors employing mercury-free approaches typically suffer from binding competition for metal ions and fouling by organic substances and surfactants in natural waters, making sample pretreatments such as wet ashing necessary. In this work, we have developed mercury-free sensors by coating a composite of thiol self-assembled monolayers on mesoporous supports (SH-SAMMS™) and Nafion on glassy-carbon electrodes. With the combined benefit of SH-SAMMS™ as an outstanding metal preconcentrator and Nafion as an antifouling binder, the sensors could detect 0.5 ppb of Pb and 2.5 ppb of Cd in river water, Hanford groundwater, and seawater with a minimal amount of preconcentration time (few minutes) and without any sample pretreatment. The sensor could also detect 2.5 ppb of Cd, Pb, and Cu simultaneously. The electrodes have long service times and excellent single and inter-electrode reproducibility (5% R.S.D. after 8 consecutive measurements). Unlike SAMMS™-carbon paste electrodes, the SAMMS™-Nafion electrodes were not fouled in samples containing albumin and successfully detected Cd in human urine. Other potentially confounding factors affecting metal detection at SAMMS™-Nafion electrodes were studied, including pH effect, transport resistance of metal ions, and detection interference. With the ability to reliably detect low metal concentration ranges without sample pretreatment and fouling, SAMMS™-Nafion composite sensors have the potential to become the next-generation metal analyzers for environmental and bio-monitoring of toxic metals.  相似文献   

4.
A fully automated portable analyzer for toxic metal ion detection based on a combination of a nanostructured electrochemical sensor and a sequential flow injection system has been developed in this work. The sensor was fabricated from a carbon paste electrode modified with acetamide phosphonic acid self-assembled monolayer on mesoporous silica (Ac-Phos SAMMS) which was embedded in a very small wall-jet (flow-onto) electrochemical cell. The electrode is solid-state and mercury-free. Samples and reagents were injected into the system and flowed through the electrochemical cell by a user programmable sequential flow technique which required minimal volume of samples and reagents and allowed the automation of the analyzer operation. The portable analyzer was evaluated for lead (Pb) detection due to the excellent binding affinity between Pb and the functional groups of Ac-Phos SAMMS as well as the great concern for Pb toxicity. Linear calibration curve was obtained in a low concentration range (1-25 ppb of Pb(II)). The reproducibility was excellent; the percent relative standard deviation was 2.5 for seven consecutive measurements of 10 ppb of Pb(II) solution. Excess concentrations of Ca, Ni, Co, Zn, and Mn ions in the solutions did not interfere with detection of Pb, due to the specificity and the large number of the functional groups on the electrode surface. The electrode was reliable for at least 90 measurements over 5 days. This work is an important milestone in the development of the next-generation metal ion analyzers that are portable, fully automated, and remotely controllable.  相似文献   

5.
The preparation, characterization and analytical applications of gold electrodes modified with ω-mercapto alkyl/aryl sulfonates are described. The devices resulted effective for the determination of free and labile Pb(II) in water samples by anodic stripping voltammetry (Edep = −600 mV) and in particular 2-mercaptobenzimidazole-5-sulfonate (MBIS) offered the best performances with detection limit of 0.4 μg L−1.Quantitative stripping of Pb from the electrode surface during the anodic scan, is obtained using sodium citrate buffer (pH = 9.0) as supporting electrolyte. Natural waters were analysed by standard addition method with good recoveries (mean percentage = 97%); no fouling effects due to humic acids or other organic constituents were observed in the reported conditions.  相似文献   

6.
A novel flow injection ion chromatograph (FI-IC) system has been developed to fully automate pretreatment procedures for multi-elemental analysis of trace metals in seawater by inductively coupled plasma mass spectrometer (ICPMS). By combining 10-port, 2 position and 3-way valves in the FI-IC manifold, the system effectively increase sample throughput by simultaneously processing three seawater samples online for: sample loading, injection, buffering, preconcentration, matrix removal, metal elution, and sample collection. Forty-two seawater samples can be continuously processed without any manual handing. Each sample pretreatment takes about 10 min by consuming 25 mL of seawater and producing 5 mL of processed concentrated samples for multi-elemental offline analysis by ICPMS. The offline analysis improve analytical precision and significantly increase total numbers of isotopes determined by ICPMS, which include the metals Al, Cd, Co, Cr, Cu, Fe, Mn, Ni, Pb, Ti, V, and Zn. The blank value and detection limits of trace metals using the system with ICPMS analysis all range from 0.1 to 10 parts per trillion (ppt), except Al, Fe, and Zn. The accuracy of the pretreatment system was validated by measuring open-ocean and coastal reference seawater, NASS-5 and CASS-4. Using the system with ICPMS analysis, we have obtained reliable trace metal concentrations in the water columns of the South China Sea. Possessing the features of full automation, high throughput, low blank, and low reagent volume used, the system automates and simplifies rigorous and complicated pretreatment procedures for multi-elemental analysis of trace metals in seawater and effectively enhances analytical capacity for trace metal analysis in environmental and seawater samples.  相似文献   

7.
Li D  Jia J  Wang J 《Talanta》2010,83(2):332-336
A bismuth-film modified graphite nanofibers-Nafion glassy carbon electrode (BiF/GNFs-NA/GCE) was constructed for the simultaneous determination of trace Cd(II) and Pb(II). The electrochemical properties and applications of the modified electrode were studied. Operational parameters such as deposition potential, deposition time, and bismuth ion concentration were optimized for the purpose of determination of trace metal ions in 0.10 M acetate buffer solution (pH 4.5). Under optimal conditions, based on three times the standard deviation of the baseline, the limits of detection were 0.09 μg L−1 for Cd(II) and 0.02 μg L−1 for Pb(II) with a 10 min preconcentration. In addition, the BiF/GNFs-NA/GCE displayed good reproducibility and selectivity, making it suitable for the simultaneous determination of Cd(II) and Pb(II) in real sample such as river water and human blood samples.  相似文献   

8.
《Electroanalysis》2004,16(16):1299-1304
As a result of industrialization lead is one of the most widely dispersed toxic heavy metals in the environment. There is a pressing need for a reliable, affordable and portable analytical technique for routine determination of lead at trace levels in biological and environmental samples. Despite their potential for portability and low cost, the currently available electrochemical stripping methods still have limited commercial availability. Among the reasons are the relatively large sample volumes and the large amount of reagents needed (1–3 mL), lower than required precision, and the inconvenience of a rotated electrode system. The Rotating Sample System is a unique approach to electrochemical stripping, devised for 20 μL sample droplets utilizing a large surface area electrode. This design combines the advantages of a microelectrode and a rotated electrode system. The semispherical sample drop itself is rotated by a fine gas jet directed at it tangentially, eliminating the need for a sample container. Neither fine moving mechanical parts nor sophisticated controls are required. The detection limit for lead(II) was found low enough and the reproducibility is sufficient for routine determinations in biomedical samples (5 ppb, 6%). The system can support a CDC recommended screening for blood lead levels and an on‐site analysis of environmental samples as well. Under suitable conditions calibration free direct determinations can also be performed.  相似文献   

9.
Screen-printed silver electrodes (AgSPEs), without chemical modification, has been investigated as disposable sensors for the measurement of trace levels of Pb2+. Potential segment analysis indicates that the formation of underpotential and bulk depositions of Pb is not strongly coupled on the AgSPE. The possibility of determining Pb2+ at trace levels using the reversible underpotential deposition peak was examined by square-wave anodic stripping voltammetry without removal of oxygen. Under the optimized analytical conditions, the obtained sensitivity, linearity, and detection limit are 0.355 μA/ppb, 5-80 ppb (r=0.9992), and 0.46 ppb (S/N=3), respectively. The electrode is quite stable for repetitive measurements. The interference effect was thoroughly studied with various metals and no significant change in current was found in the determination of 5 ppb Pb2+. The practical applications were demonstrated to measure trace Pb2+ in natural waters.  相似文献   

10.
A cost-effective sequential injection monosegmented flow analysis (SI-MSFA) with anodic stripping voltammetric (ASV) detection has been developed for determination of Cd(II) and Pb(II). The bismuth film working electrode (BiFE) was employed for accumulative preconcentration of the metals by applying a fixed potential of −1.10 V versus Ag/AgCl electrode for 90 s. The SI-MSFA provides a convenient means for preparation of a homogeneous solution zone containing sample in an acetate buffer electrolyte solution and Bi(III) solution for in situ plating of BiFE, ready for ASV measurement at a flow through thin layer electrochemical cell. Under the optimum conditions, linear calibration graphs in range of 10-100 μg L−1 of both Cd(II) and Pb(II) were obtained with detection limits of 1.4 and 6.9 μg L−1 of Cd(II) and Pb(II), respectively. Relative standard deviations were 2.7 and 3.1%, for 11 replicate analyses of 25 μg L−1 Cd(II) and 25 μg L−1 Pb(II), respectively. A sample throughput of 12 h−1 was achieved with low consumption of reagent and sample solutions. The system was successfully applied for analysis of water samples collected from a draining pond of zinc mining, validating by inductively coupled plasma-optical emission spectroscopy (ICP-OES) method.  相似文献   

11.
Zhang X  Liu Y  Zhang J  Hu Z  Hu B  Ding L  Jia L  Chen H 《Talanta》2011,85(3):1665-1671
High throughput analysis of sunscreen agents present in cream cosmetic has been demonstrated, typically 2 samples per minute, using neutral desorption extractive electrospray ionization mass spectrometry (ND-EESI-MS) without sample pretreatment. For the targeted compounds such as 4-Aminobenzoic acid and oxybenzone, ND-EESI-MS method provided linear signal responses in the range of 1-100 ppb. Limits of detection (LOD) of the method were estimated at sub-ppb levels for the analytes tested. Reasonable relative standard deviation (RSD = 8.4-16.0%) was obtained as a result of 10 independent measurements for commercial cosmetics samples spiked with each individual sunscreen agents at 1-10 ppb. Acceptable recoveries were achieved in the range of 87-116% for direct analysis of commercial cream cosmetic samples. The experimental data demonstrate that ND-EESI-MS is a useful tool for high throughput screening of sunscreen agents in highly viscous cream cosmetic products, with the capability to obtain quantitative information of the analytes.  相似文献   

12.
The preparation of Hg(II)-modified multi walled carbon nanotube (MWCNT) by reaction of oxidized MWCNT with aqueous HgCl2 was carried out. The Hg(II)-modified multi walled carbon nanotube (Hg(II)/MWCNT) dispersed in Nafion solution was used to coat the polished graphite electrode surface. The Hg(II)/MWCNT modified graphite electrode was held at a cathodic potential (−1.0 V) to reduce the coordinated Hg(II) to Hg forming nanodroplets of Hg. The modified electrode was characterized by FESEM/EDAX which provided useful insights on the morphology of the electrode. The SEM images showed droplets of Hg in the size of around 260 nm uniformly distributed on the MWCNT. Differential pulse anodic stripping voltammetry (DPASV) and electrochemical impedance spectroscopy were used to study the Hg(II) binding with MWCNT. Differential pulse anodic stripping voltammetry of ppb levels of cadmium and lead using the modified electrode yielded well-defined peaks with low background current under a short deposition time. Detection limit of 0.94 and 1.8 ng L−1 were obtained following a 3 min deposition for Pb(II) and Cd(II), respectively. Various experimental parameters were characterized and optimized. High reproducibility was observed from the RSD values for 20 repetitive measurements of Pb(II) and Cd(II) (1.7 and 1.9%, respectively). The determination of Pb(II) and Cd(II) in tap water and Pb(II) in human hair samples was carried out. The above method of fabrication of Hg(II)/MWCNT modified graphite electrode clearly suggests a safe route for preparing Hg immobilized electrode for stripping analysis.  相似文献   

13.
Bismuth was evaluated as an internal standard for the direct determination of Pb in vinegar by graphite furnace atomic absorption spectrometry using Ru as a permanent modifier with co-injection of Pd/Mg(NO3)2. The correlation coefficient of the graph plotted from the normalized absorbance signals of Bi versus Pb was r = 0.989. Matrix effects were evaluated by analyzing the slope ratios between the analytical curve obtained from reference solutions prepared in 0.2% (v/v) HNO3 and analytical curves obtained from Pb additions in red and white wine vinegar samples. The calculated ratios were around 1.04 and 1.02 for analytical curves established applying an internal standard and 1.3 and 1.5 for analytical curves without. Analytical curves in the 2.5–15 μg L− 1 Pb concentration interval were established using the ratio Pb absorbance to Bi absorbance versus analyte concentration, and typical linear correlations of r = 0.999 were obtained. The proposed method was applied for direct determination of Pb in 18 commercial vinegar samples and the Pb concentration varied from 2.6 to 31 μg L− 1. Results were in agreement at a 95% confidence level (paired t-test) with those obtained for digested samples. Recoveries of Pb added to vinegars varied from 96 to 108% with and from 72 to 86% without an internal standard. Two water standard reference materials diluted in vinegar sample were also analyzed and results were in agreement with certified values at a 95% confidence level. The characteristic mass was 40 pg Pb and the useful lifetime of the tube was around 1600 firings. The limit of detection was 0.3 μg L− 1 and the relative standard deviation was ≤ 3.8% and ≤ 8.3% (n = 12) for a sample containing 10 μg L− 1 Pb with and without internal standard, respectively.  相似文献   

14.
The IAEA established in 1994 a co-ordinated research programme (CRP) on "Reference Materials for Microanalytical Nuclear Techniques" as part of its efforts to promote and strengthen the use of nuclear analytical technologies in member states with the specific aim of improving the quality of analysis of nuclear, environmental, and biological materials. The objectives of this initiative were: to identify suitable biological reference materials which could serve the needs for quality control in microanalytical techniques; to evaluate existing CRMs for use in microanalytical investigations; to evaluate appropriate sample pretreatment procedures for materials being used for analysis with microanalytical techniques; to identify analytical techniques which can be used for characterisation of homogeneity determination, and to apply such techniques to the characterization of candidate reference materials for use with microanalytical techniques. The CRP lasted for 4 years and seven laboratories and the Agency's Laboratories in Seibersdorf participated. A number of materials including the candidate reference materials IAEA 338 (lichen) and IAEA 413 (single cell algae, elevated level) were evaluated for the distribution of elements such as Cl, K, Ca, Cr, Mn, Fe, Zn, As, Br, Rb, Cd, Hg, and Pb. The results obtained during this CRP suggest that: each element exhibits its characteristic distribution in a matrix described by the "Ingamels' sampling constant" or the "relative homogeneity factor" of Kurfuerst; both concepts are valid over a large range of sample mass used for analysis (from 0.1 g to around 100 mg); and materials being characterised quantitatively for element homogeneity could be used for the experimental determination of total uncertainty of other analytical techniques. As far as we are aware this is the first time the concept of quantitative characterisation of homogeneity has been applied to potential reference materials and the first demonstration of the feasibility and usefulness of the concept with particular emphasis on enhancing quality control opportunities for microanalytical techniques.  相似文献   

15.
Helton KL  Nelson KE  Fu E  Yager P 《Lab on a chip》2008,8(11):1847-1851
This report details an approach to saliva conditioning for compatibility of raw patient samples with microfluidic immunoassay components, principally biosensor surfaces susceptible to fouling. Stimulated whole human saliva spiked with a small molecule analyte (phenytoin, 252 Da) was first depleted of cells, debris and high molecular weight glycoproteins (mucins) using membrane filtration. This process significantly reduced but did not eliminate fouling of biosensor surfaces exposed to the sample. An H-filter, which separates solutes from mixed samples based on their diffusion in laminar flow, was used to extract the analyte from the remaining large molecular weight species in the filtered saliva sample. Patient samples treated in this way retained 23% of the analyte with 97% and 92% reduction in glycoproteins and proteins, respectively, and resulted in 3.6 times less surface fouling than either untreated or filtered saliva alone. These sample conditioning steps will enable the use of fouling-sensitive detection techniques in future studies using clinical saliva samples.  相似文献   

16.
Menegário AA  Packer AP  Giné MF 《The Analyst》2001,126(8):1363-1366
Trace elements in small sample volumes of saliva were determined by coupling a high efficiency direct injection nebulizer to inductively coupled plasma mass spectrometry and employing quantification by isotope dilution. Aliquots of 0.4 ml of human saliva were mixed with 0.1 ml of concentrated nitric acid and diluted to 2 ml with water. Sample solutions were spiked with an isotopic solution enriched in 135Ba, 112Cd, 65Cu, 206Pb and 66Zn. The amount of each isotope added to the samples and the measurement procedure were adjusted to attain precise analytical results calculated from the isotope ratios 135Ba/138Ba, 112Cd/114Cd, 65Cu/63Cu, 206Pb/208Pb and 66Zn/68Zn. Data acquisition for Ba, Cu and Zn isotopes was performed for a single sample injection of 50 microl and in another sample injection the Cd and Pb isotopes were measured. Concentrations ranging from 5.0 to 16 microg l(-1) for Ba, from 0.50 to 1.1 microg l(-1) for Cd, from 6.0 to 50 microg l(-1) for Cu, from 0.8 to 18.8 microg l(-1) for Pb and from 46.0 to 230 microg l(-1) for Zn were found in saliva samples. Detection limits of 0.11, 0.03, 0.40, 0.05 and 0.59 microg l(-1) were determined for Ba, Cd, Cu, Pb and Zn, respectively. The concentrations found by isotope dilution were in agreement with those of the completely digested samples quantified by external calibration. The direct analysis of 30 samples per hour was attained with the proposed procedure, avoiding time-consuming digestion steps, contamination risks and matrix effects.  相似文献   

17.
Trimethylamine (TMA) is well-known for manifesting the odor of rotting fish and urine. The analysis of TMA in environmental samples generally suffers from low reproducibility and poor sensitivity. In this study, a technique for the quantitative analysis of gas phase TMA was developed using thermal desorption (TD)-gas chromatography (GC)-time of flight mass spectrometry (TOF-MS). This new approach yielded good linearity (R2 = 0.9930), precision (RSE = 1.59%), and high sensitivity with the method detection limit (MDL) of 51 pg, i.e., detection of 0.021 ppb of TMA at 1 L sample (limit of detection (LOD): 5.32 pg (0.002 ppb). This method was tested against gas samples collected from two representative sources of TMA: (1) rotten thornback fish and (2) cat urine-soaked clay. The concentration of TMA in these samples, when analyzed after treatment at varying dilution ratios, averaged 293 ± 29.7 ppm (RSE = 3.82%) and 74.1 ± 5.78 ppb (RSE = 3.19%), respectively. The feasibility of this approach, when tested with TD–GC–Quadruple (Q) MS, showed a good compatibility with moderately reduced sensitivity. The results of this study demonstrated that one can achieve highly reliable and reproducible analysis of TMA from environmental samples when using thermal desorption (for pretreatment) and detection (by the TOF or Q-MS system).  相似文献   

18.
Sensitive and stable monitoring of heavy metals in seawater using screen-printed electrodes (SPE) is presented. The analytical performance of SPE coupled with square wave anodic stripping voltammetry (SWASV) for the simultaneous determination of Pb and Cd in seawater samples, in the low μg L−1 range, is evaluated. The stripping response for the heavy metals following 2 min deposition was linear over the concentration range examined (10-2000 μg L−1) with detection limits of 1.8 and 2.9 μg L−1 for Pb and Cd, respectively. The accuracy of the method was validated by analyzing metal contents in different spiked seawater samples and comparing these results to those obtained with the well-established anodic stripping voltammetry using the hanging mercury drop electrode. Moreover, a certified reference material was also used and the results obtained were satisfactory.  相似文献   

19.
Methods were developed to quantify the amount of perfluorooctanoic acid (PFOA) extracted from textile and carpet samples through contact with water, methanol, and sweat and saliva simulants using LC/MS/MS. The limit of quantitation (LOQ) for samples extracted in water and sweat simulant is 1 ppb (ng PFOA (g sample)(-1)) while the limits of quantitation for samples extracted in saliva simulant and methanol were 3 ppb and 2.5 ppb, respectively. Method validation results are provided for a polyester control textile sample that was extracted in water on two different days by different analysts, which gave an overall recovery of 103% and standard deviation of 5.3% for 30 analyses. However, for routine application of these methods to a large number of sample sets differing in chemical and physical compositions, a complete validation for each sample type is not practical or possible since control samples for fortifications are often not available. Instead, suitable analytical methods and acceptance criteria are described which ensure accurate PFOA quantitation in each of the solvent extract types. During routine use of these methods, post-extraction spike recoveries for the different sample types and solvents are 100 +/- 15% using a dual isotopically labeled (13)C-PFOA internal standard to correct for matrix effects. A comparison of extraction solvent versus time using a wrist action shaker for textile and carpet samples demonstrates that the total extractable amount of PFOA is similar for each of the solvent types. However, as expected the rate of extraction in water and simulants is significantly less than that of methanol. Finally, a comparison of 2 h and 24 h wrist action shaker extractions with a 1.5 h pressurized fluid extraction (PFE) in methanol reveals that the 24 h wrist action shaker yields the highest results. The 2 h wrist action shaker results are similar to those of the 1.5 h PFE extraction.  相似文献   

20.
The possibility of applying antimony-film modified glassy carbon electrode in sequential-injection analysis (SIA) was investigated with the objective of determining Pb(II) and Cd(II) by anodic stripping voltammetry (ASV). The conditions of antimony-film deposition concerning composition of the plating/carrier solutions, concentrations of Sb(III) and hydrochloric acid, effects of different supporting electrolyte salts, and plating potential were optimized. It was found that the antimony-film deposition on glassy carbon substrate in a sample solution consisting of 750 μg L−1 Sb(III), 0.5 mol L−1 HCl at −1.5 V (vs. Ag/AgCl/3 mol L−1 KCl) yielded a modified electrode suitable for the determination of Pb(II) and Cd(II) at the μg L−1 level. The reproducibility of the analytical signals was characterized by a relative standard deviation lower than 2.8%, and the calculated values of detection limits were 1.2 μg L−1 for Pb(II) and 1.4 μg L−1 for Cd(II). The presence of KSCN in the sample solution offers the possibility of detecting ions with more negative oxidation potentials like Zn(II), Mn(II) or Cr(III). The developed SIA-ASV procedure was compared with the commonly used batch method, and its applicability was tested on a spiked tap water sample.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号