首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 62 毫秒
1.
Alzahrani E  Welham K 《The Analyst》2011,136(20):4321-4327
Sample pretreatment is a required step in proteomics in order to remove interferences and preconcentrate the samples. Much research in recent years has focused on porous monolithic materials since they are highly permeable to liquid flow and show high mass transport compared with more common packed beds. These features are due to the micro-structure within the monolithic silica column which contains both macropores that reduce the back pressure, and mesopores that give good interaction with analytes. The aim of this work was to fabricate a continuous porous silica monolithic rod inside a heat shrinkable tube and to compare this with the same material whose surface has been modified with a C(18) phase, in order to use them for preconcentration/extraction of proteins. The performance of the silica-based monolithic rod was evaluated using eight proteins; insulin, cytochrome C, lysozyme, myoglobin, β-lactoglobulin, ovalbumin, hemoglobin, and bovine serum albumin at a concentration of 60 μM. The results show that recovery of the proteins was achieved by both columns with variable yields; however, the C(18) modified silica monolith gave higher recoveries (92.7 to 109.7%) than the non-modified silica monolith (25.5 to 97.9%). Both silica monoliths can be used with very low back pressure indicating a promising approach for future fabrication of the silica monolith inside a microfluidic device for the extraction of proteins from biological media.  相似文献   

2.
A simple and sensitive liquid chromatographic method for the separation and quantification of mono- and disaccharides in raw- and processed-milk is described. Samples of cows’, buffalos’, sheeps’ and goats’ milk were analyzed upon clarification and appropriate dilution for the quantification of lactose, galactose, glucose and N-acetylglucosamine (GlcNAc). The separation was accomplished by high-performance anion-exchange chromatography with pulsed amperometric detection (HPAEC-PAD), using a gold working electrode and dilute alkaline eluents modified by a millimolar concentration of barium acetate. The eluent composition employed was designed to provide optimum separation with respect to the selected sample, without interference from the matrix components. The analytical method was successfully employed for the determination of mono- and disaccharides naturally occurring in dairy milk, mozzarella cheese and whey samples, with high sensitivity and accuracy.  相似文献   

3.
Proteins in commercial bovine milk have been separated by two-dimensional gel electrophoresis and examined by matrix-assisted laser desorption/ionisation mass spectrometry. Gel separation was conducted in two different pH gradients, 3-10 and 6-11; the latter range resulted in a higher spot resolution and favoured the basic proteins. We have limited the time-of-flight mass spectrometry analysis to the linear mode to examine the capability of reliable relative molecular masses of the intact proteins in their characterisation. The present study draws attention to the difficulty of identifying basic proteins with low molecular masses (below 12000 Da) that are commonly encountered in milk samples.  相似文献   

4.
Online solid phase extraction followed by liquid chromatography coupled to tandem mass spectrometry was used for the determination of 15 fluoroquinolones and one quinolone antibiotic in raw bovine and skimmed commercial milk. Milk samples were partially deproteinized and defatted by 15 min centrifugation and then subjected to online solid phase extraction. Chromatographic separation was achieved in less than 15 min. Identification and quantification of the compounds of interest were performed by selected reaction monitoring, using an electrospray ionization source. Relative recoveries were calculated for raw milk (at 0.5, 1 and 1.5 times the MRL, or assuming 30 ng/mL for non permitted compounds) and skimmed milk (at 30 ng/mL) and ranged between 65% and 123% (raw milk) or 78% and 109% (skimmed milk). Matrix interferences were also assessed and yielded significant suppression and enhancement effects, which, at the time of quantification, were corrected by the use of six isotopically labeled standards. Quality parameters of the method were established, and limits of detection of selected antibiotics in raw milk ranged from 0.01 to 1.93 ng/mL, while in skimmed milk from 0.03 to 4.23 ng/mL. The validation of the method has been carried out according to the requirements set by the 2002/657/EC regulation. Finally, the applicability of the method was tested by analysing 28 milk samples.  相似文献   

5.
Yang Y  Li C  Lee KH  Craighead HG 《Electrophoresis》2005,26(19):3622-3630
We report the integration of solid-phase extraction (SPE) with mass spectrometry (MS) through an on-chip electrospray tip for sample precleaning and preconcentration. An in situ polymerized alkylacrylate-based monolithic column was used as the stationary phase for the on-chip SPE. Each microchip consists of two sets of microchannels and their respective integrated electrospray tips, with a common gold electrode. After the microchip was fabricated from cycloolefin polymer by hot embossing, thermal bonding, and annealing steps, a mixture of monomers and porogenic solvents was pumped into the microchannels and certain areas of the main microchannels were exposed to UV irradiation through a mask. The resulting porous monolithic beds that were polymerized from different compositions of the mixture were characterized by scanning electron microscopy. The microchip containing the monolithic column was then interfaced to an ion trap (IT) mass spectrometer by modifying a commercially available interfacing system. Makeup solution from the side channel was infused concurrently with the solution flowing into the main channel, and the mixture of these two solutions was sprayed into the MS orifice. Both the adsorption and elution of a pharmaceutical test compound, imipramine, to and from the on-chip SPE columns were monitored by MS. The potential application of this device for sample cleanup was demonstrated by pretreatment of urine samples spiked with imipramine.  相似文献   

6.
The present report describes the design and application of a dual sprayer system for high-throughput proteome analysis. This system comprises parallel solid-phase extraction cartridges used for preconcentration and desalting of proteolytic digests prior to nanoelectrospray mass spectrometry analyses. Tryptic peptides from in-gel digest of protein bands/spots are first adsorbed on styrene divinyl benzene membrane and subsequently eluted with a short plug of organic buffer prior to infusion to the mass spectrometer at a flow rate of typically 500 nL/min. Tryptic peptide eluting from the membrane are analyzed by the mass spectrometer by moving in turn each sprayer in front of the sampling orifice. Sequential injection, preconcentration and analyses of tryptic digests are typically achieved with a throughput of up to 3.5 min/sample and a detection limit of approximately 8-80 fmol per injection. Replicate injections of peptide mixtures indicated that reproducibility of peak areas ranged from relative standard deviations (RSD) of 1.1% to 4.5%. The application of this device is demonstrated for digests of gel-isolated proteins obtained from sodium dodecyl sulfate-polyacrylamide gel electrophoresis (SDS-PAGE) separation of rat liver plasma membrane and from two-dimensional gel electrophoresis of total cell lysate extracts from human prostatic cancer cell.  相似文献   

7.
Monolithic columns based on poly-(styrene-divinylbenzene) (PS-DVB) were utilized both for preconcentration (in 10 mm x 0.20 mm I.D. format) and analytical separation (in 60 mm x 0.20 and 0.10 mm I.D. format) of peptides and proteins in column switching micro-scale high-performance liquid chromatography. A special holder for short monolithic preconcentration columns was designed and pressure durability tests approved long-term stability up to 400 bar. An 11-20% decrease in the average peak widths of nine peptides was obtained upon combining a preconcentration column with an analytical column as compared with a setup using an analytical column only. Trapping efficiency, especially for small and hydrophilic peptides, was optimized by using 0.10% heptafluorobutyric acid instead of 0.050% trifluoroacetic acid as solvent additive during sample loading. Using a 10 mm x 0.20 mm I.D. preconcentration column, loadabilities between 0.5 and 1.6 microg were determined by frontal analysis of proteins and bioactive peptides, respectively. A 100-fold concentration followed by direct on-line intact mass determination is demonstrated for diluted (3 micromolL(-1)) protein solutions. The applicability of the monolithic preconcentration column for multidimensional chromatography was tested by off-line two-dimensional separation, combining strong cation-exchange chromatography and ion-pair reversed-phase chromatography. Peptide identification data from digested protein mixtures demonstrated reproducibilities of 46-75% in triplicate analyses, and confident peptide identifications of low abundant peptides even in the presence of a 650-fold molar excess of high abundant peptides.  相似文献   

8.
A method was developed for the quantification of cow milk adulteration in goat milk, based on solvent separation of whey proteins followed by high-performance liquid chromatography with electrospray ionization mass spectrometry (HPLC/ESI-MS). The presence of cow milk was determined using beta-lactoglobulin whey protein as the molecular marker. The adulterants were identified using both retention time and molecular mass derived from multiply charged molecular ions. Standard solutions containing cow and goat milk in different volume ratios were prepared and analyzed. Good linearity covering cow milk content from 5% and above was obtained. The proposed method identifies the adulterants using accurate molecular masses for protein identification and detects the addition of cow milk to goat milk at levels as low as 5%.  相似文献   

9.
A unique approach of automating the integration of monolithic capillary HPLC-based protein separation and on-plate digestion for subsequent MALDI-MS analysis has been developed. All liquid-handling procedures were performed using a robotic module. This automated high-throughput method minimizes the amount of time and extensive labor required for traditional in-solution digestion followed by exhaustive sample cleanup and analysis. Also, precise positioning of the droplet from the capillary HPLC separation onto the MALDI plate allows for preconcentration effects of analytes for improved sensitivity. Proteins from primary esophageal Barrett's adenocarcinoma tissue were prefractionated by chromatofocusing and analyzed successfully by this automated configuration, obtaining rapid protein identifications through PMF and sequencing analyses with high sequence coverage. Additionally, intact protein molecular weight values were obtained as a means to further confirm protein identification and also to identify potential sequence modifications of proteins. This simple and rapid method is a highly versatile and robust approach for the analysis of complex proteomes.  相似文献   

10.
The application of microfabricated devices coupled to a quadrupole time-of-flight mass spectrometer (Qq-TOF-MS) is presented for the analysis of trace level digests of gel-isolated proteins. In order to enhance the sample loading for proteomics analyses, two different on-chip sample preconcentration techniques were evaluated. First, a sample stacking procedure that used polarity switching to remove the sample buffer prior to zone electrophoresis was easily integrated on the microfabricated devices. With the present chip design, this preconcentration technique provided up to 70 nL sample injection with sub-nM detection limits for most peptide standards. For applications requiring larger sample loading, a disposable adsorption preconcentrator using a C18 membrane is incorporated outside the chip. This preconcentration method yielded lower peptide recoveries than that obtainable with sample stacking, and provided a convenient means of injecting several microL of sample with detection limits of typically 2.5 nM for hydrophobic peptides. The analytical merits of both sample enrichment approaches are described for the identification of bands isolated from two-dimensional (2-D) gel separation of protein extracts from Haemophilus influenzae. Accurate molecular mass measurements (< 5 ppm) in peptide mapping experiments is obtained by introducing an internal standard via a post-separation channel. Rapid identification of trace level peptides is also demonstrated using on-line tandem mass spectrometry and database searching with peptide sequence tags.  相似文献   

11.
The porosity of a monolithic capillary column having a structure optimized for gas chromatographic analysis was investigated by means of hydrodynamic and size-exclusion chromatography. It was found that the total porosity of the column exceeded 90%, and the column had a bimodal pore structure with a micropore diameter of about 1.5 nm and a macropore diameter of about 1.2 μm. The column separated with good selectivity high molecular mass polystyrene standards with molecular masses higher than 100 kDa and low molecular mass solutes of up to 500 Da. The structure of monolithic column has to be optimized for application in hydrodynamic chromatography with an aim to provide selectivity on separation of polymers with molecular mass from 1 to 100 kDa.  相似文献   

12.
The purpose of the work described in this paper was to develop an easy and quick in-vitro method for comparing the bioavailability of selenium in cows’ milk after different cow feed. The study focuses on bioavailability differences resulting from the use of different selenium species (organic selenium as selenised yeast and sodium selenite) for supplementation of forage. A procedure for determination of selenium in cows’ milk and dialysates, by hydride-generation atomic-fluorescence spectrometry (HG-AFS) after microwave-assisted acid digestion, was optimised. The results show it is possible to obtain cows’ milk enriched with selenium at different concentration without altering the original composition of the milk. The bioavailability was statistically greater for cows’ milk obtained after supplementation of forage with organic selenium at levels of 0.4 and 0.5 μg Se g−1 than for that obtained after supplementation with inorganic and organic selenium at levels of 0.2 and 0.3 μg Se g−1.  相似文献   

13.
A simple and sensitive method for the simultaneous extraction and determination of six aminoglycosides in honey and milk samples was developed using multiple monolithic fiber solid‐phase microextraction and liquid chromatography with tandem mass spectrometry. The multiple monolithic fibers based on poly(methacrylic acid‐co‐ethylenedimethacrylate) monolith as the extraction medium was used to concentrate target analytes. Because there were abundant carboxyl groups in the monolith, the monolithic fibers could extract aminoglycosides effectively through cation‐exchange and hydrophobic interactions. To obtain optimum extraction performance, several extraction parameters including desorption solvent, adsorption and desorption time, pH value and ionic strength in sample matrix, were investigated in detail. Under the optimized extraction conditions, the limits of detection of the proposed method were 0.10–0.30 and 0.23–0.59 μg/kg for honey and milk samples, respectively. Satisfactory linearity was achieved for analytes with the coefficients of determination above 0.99. At the same time, the developed method showed acceptable method repeatability and reproducibility. Finally, the proposed method was successfully applied to the determination of aminoglycosides in real honey and milk samples. Recoveries obtained for the determination of six target analytes in spiking samples ranged from 67.9 to 110%, and the relative standard deviations were in the range of 1.2–11%.  相似文献   

14.
A rapid screening and determination of 150 veterinary drugs of various classes in milk by UHPLC–high-resolution quadrupole time-of-flight mass spectrometry is proposed. One gram of milk was used for the analysis; the precipitation of proteins and extraction were performed with acetonitrile; the extract was analyzed without purification or preconcentration. Veterinary drugs were identified by accurate masses of analyte ions produced by electrospray ionization, their retention time, and the pattern of ion isotope distribution (mSigma). The quantitative analysis of the detected analytes was carried out by the standard addition method. The limits of detection were 0.1–0.5 ng/g; the analytical ranges were (0.1)1–500 ng/g; the duration of screening was 20–30 min; and the analysis time was 30–40 min. The relative standard deviation of the results for all analytes did not exceed 15%.  相似文献   

15.
This review is focused on planar chromatography hyphenated with mass‐spectrometric detection for analysis of low‐molecular‐mass solutes. Various kinds of hyphenations are discussed with attention paid to the preparation of thin layer plates suited both for the mass‐spectrometric detection of the resolved solutes direct from thin‐layer plates and for indirect mass‐spectrometric detection of the resolved solutes, performed by scraping, extracting, purifying, and concentrating the analyte from the thin‐layer chromatography plate. Plates with monolithic layers are relatively new for thin‐layer chromatography but they can successfully be combined with mass‐spectrometric technique in a pursuit of comprehensive local sample composition information. Preparation of monolithic layers of different porosity and structure based on organic, inorganic, and composite materials is illustrated together with examples of successful separation and detection of low‐molecular‐mass solutes by means of matrix‐assisted and surface‐assisted laser desorption mass spectrometry.  相似文献   

16.
Summary A simple and rapid procedure based on solid phase disk extraction (SPDE), adsorption chromatography on acidified silica gel and GC-MS analysis was developed for the determination of 8 organochlorine pesticides and 19 PCB congeners in human milk. By using the SPDE procedure, a high throughput and parallel sample processing could be achieved. Method variables were optimized on whole cow's milk (3.5% fat) fortified at levels close to concentrations found in human milk. Recoveries of target analytes were acceptable and ranged from 69 to 102% and 86 to 120% for whole and skimmed milk, respectively. By the use of two stage clean-up and narrow bore capillary columns, detection limits as low as 20 pg mL−1 could be obtained. The method was used for the determination of organochlorine pollutants in human milk from 19 individuals from Romania. The concentrations of PCBs were low, whereas those of organochlorine pesticides were higher than the values reported from other European countries.  相似文献   

17.
We have prepared molecularly imprinted beads with molecular recognition capability for target molecules containing the penicillanic acid substructure. They were prepared by (a) grafting mesoporous silica beads with 6-aminopenicillanic acid as the mimic template, (b) filling the pores with a polymerized mixture of methacrylic acid and trimethylolpropane trimethacrylate, and (c) removing the silica support with ammonium fluoride. The resulting imprinted beads showed good molecular recognition capability for various penicillanic species, while antibiotics such as cephalosporins or chloramphenicol were poorly recognized. The imprinted beads were used to extract penicillin V, nafcillin, oxacillin, cloxacillin and dicloxacillin from skimmed and deproteinized milk in the concentration range of 5–100 μg·L?1. The extracts were then analyzed by micellar electrokinetic chromatography by applying reverse polarity staking as an in-capillary preconcentration step, and this resulted in a fast and affordable method within the MRL levels, characterized by minimal pretreatment steps and recoveries of 64–90 %.
Figure
Penicillanic acid-imprinted beads prepared in preformed porous silica by an imprinting & etching approach show selectivity towards β-lactams antibiotics. Molecularly imprinted solid phase extraction/micellar electrokinetic chromatography coupled with in-capillary preconcentration resulted in a fast and affordable method for penicillins in milk at MRL levels.  相似文献   

18.
Batch treatment with Chelex-100 resin was investigated for preconcentration of trace metals in sea water followed by determination by inductively-coupled plasma atomic emission spectrometry. The preconcentration conditions such as resin weight, stirring time, and amount of ammonium acetate buffer solution were carefully examined for effective multi-element preconcentration from sea water. The resin weight could be decreased to 0.5 g (dry weight) for 1 l of sea water, which was much less than that required in the column method, and a preconcentration factor of 100 was achieved. Al, Ti, V, Mn, Fe, Co, Ni, Cu, Zn, Y, Mo, Cd and Pb in sea water were measured with good precision. The detection limits ranged from 6 to 180 ng l?1. The time required for one sample by the batch method was only 3 h.  相似文献   

19.
Bones J  Thomas K  Nesterenko PN  Paull B 《Talanta》2006,70(5):1117-1128
A simplified preconcentration method for a range of ultra-trace level pharmaceuticals in natural waters has been developed. Solid phase extraction was performed on-line using a micro-reversed-phase monolithic silica column, allowing for very rapid trace enrichment from large volume (500 ml) samples with minimal sample handling. Acceptable recoveries of >70% were obtained for the majority of compounds investigated and the monolithic columns could be washed and conditioned on-line with no sample carryover and used reproducibly for up to eight extractions each. The on-line SPE-LC-UV method was coupled to electrospray ionisation ion trap mass spectrometry (ESI-MS) to increase both selectivity and specificity. Detection limits were determined in spiked river and tap water samples and found to lie in the low ng/l region using sample volumes of 500 ml, loaded at a flow rate of 10 ml/min, and therefore, were suitable for ultra trace analysis.  相似文献   

20.
A novel sugar constituent was isolated from the heteropolysaccharide excreted by Streptococcus thermophilus 8 S when grown in skimmed milk. The structure and absolute configuration were determined by means of chemical analysis, mass spectrometry, NMR spectroscopy, along with molecular dynamics simulations, and was shown to be 6-O-(3',9'-dideoxy-D-threo-D-altro-nononic acid-2'-yl)-D-glucopyranose.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号