首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 140 毫秒
1.
A mixture of 14 polychlorinated biphenyl (PCB) isomers of various congeners, representing approximately 70% of all human milk PCBs reported in the literature, was made up to identify and approximate their residues in human milk. Individual isomer levels varied from 5 to 103 nanograms per gram of milkfat with the 2,2',4,4',5,5'-hexachlorobiphenyl isomer as the major PCB contaminant of human milk. PCB isomer numbers 74, 118, 153, 138 and 180 made up approximately 75% of all PCBs as measured by this mixture. There was close agreement of total PCB isomer content in breast milk between electron capture gas chromatography and gas chromatographic mass spectrometry determinations. A major interference was encountered however for PCB isomer no. 52, whose residue level in the breast milk was approximately 3 X higher by gas liquid chromatography than by mass spectrometry.  相似文献   

2.
An analytical method is presented for precise identification and quantitation of 29 specific polychlorinated biphenyl (PCB) congeners and 15 chlorinated pesticides in human serum. Analyte surrogates PCB 30, PCB 204, 2,2',4,4',5,5'-hexabromo-biphenyl, perthane, alpha-hexachlorocyclohexane, and dichlorobenzophenone were added to each sample. The serum was extracted with an organic solvent and separated by adsorption chromatography into 3 elution fractions for high-resolution gas chromatographic analysis. Each fraction was analyzed by dual-column capillary chromatography followed by electron capture detection. Two capillary columns, DB-5 and DB-1701, with different polarities were used to increase selectivity for each analyte. Quantitation was performed by selecting 2 sets of calibration standard mixtures and 1,2-dichloronaphthalene as an internal standard. Mean recoveries ranged from 39 to 126% for selected analytes and from 31 to 88% for surrogates. Detection limits for specific congeners and pesticides are reported. Typical chromatographic profiles of calibration standard mixtures, as well as a human sample, are illustrated. Verification of each analyte is assessed, and results of analyses of selected human samples and quality control criteria used to ensure data validity also are presented.  相似文献   

3.
将超声辅助碱液分解杂质与溶剂萃取相结合,采用气相色谱-电子捕获检测(GC-ECD)建立了一种快速高效净化、萃取海洋沉积物中8种常见多溴联苯醚(PBDEs)的分析方法。样品在2.00 mol/L NaOH甲醇溶液中超声30 min,经正己烷萃取、单层硅胶净化、正己烷洗脱、旋蒸浓缩后定容至100 μL,采用GC-ECD分析。结果表明,PBDEs各单体的加标回收率为63.6%~110.3%,相对标准偏差(RSD)为1.7%~15.5%(n=5);十溴联苯醚(BDE-209)的检出限为0.097 ng/g,其他7种单体的检出限为0.002~0.011 ng/g(信噪比为3)。该方法的准确度和精密度较高,稳定性和回收率良好,可满足沉积物中PBDEs的分析要求。利用建立的方法测定了渤海表层沉积物中PBDEs的含量,8种PBDEs总含量在1.566~6.760 ng/g之间,其中BDE-209的含量为1.461~6.438 ng/g,总体呈现出由近岸向远岸递减的趋势,表明人为活动、表层冲刷和陆地河流的输入对渤海地区PBDEs的含量有重要影响。  相似文献   

4.
A radioimmunoassay was developed capable of determining Aroclor 1260 in milk at levels of from 20 to 80 ppb and in blood from 2 to 16 ppb. The values obtained by radioimmunoassay correlate well with those determined by gas-liquid chromatography (r2 = 0.96 for milk and 0.99 for blood) but were lower. Antiserum was produced in rabbits and was specific for 2,2',4,4',5,5'-hexachlorobiphenyl. It cross-reacted with congeners and isomers in Aroclor 1254 and 1260 to the extent that a 20% decrease in binding was observed with 0.1 ng of either mixture. The method requires preliminary cleanup of the extract on alumina and utilizes 25% dimethyl sulfoxide in the assay medium to promote solubilization of the substrates.  相似文献   

5.
《Analytical letters》2012,45(14):2290-2301
A novel and robust phenyl-functionalized MSU-1 (Ph-MSU) coated fiber for solid-phase microextraction (SPME) coupled to high performance liquid chromatography (HPLC) was developed for the preconcentration and the determination of 2,4,4′-trichlorobiphenyl (PCB 28), 2,4′,5-trichlorobiphenyl (PCB 31), 2,2′,5,5′-tetrachlorobiphenyl (PCB 52), 2,2′,4,5,5′-pentachlorobiphenyl (PCB 101), 2,3′,4,4′,5-pentachlorobiphenyl (PCB 118), 2,2′,3,4,4′,5′-hexachlorobiphenyl (PCB 138), 2,2′,4,4′,5,5′-hexachlorobiphenyl (PCB 153), and 2,2′,3,4,4′,5,5′-heptachlorobiphenyl (PCB 180) in environmental water samples. Experimental conditions affecting SPME were examined in detail. The Ph-MSU coating provided large porosity and short-range mesostructures necessary for high extraction capacity and rapid mass transfer of PCBs. The Ph-MSU coated fiber exhibited selectivity for PCB 28, PCB 31, PCB 118, and PCB 138 in a limited extraction time. Good linearity for all PCBs was obtained with correlation coefficients from 0.9987 to 0.9994. The recoveries were within 94.3% to 103% for the spiked water with 300 ng · L?1 per PCB. The relative standard deviations (RSDs) ranged from 3.10% to 6.23% and the limits of detection (LODs) were between 8.73 ng · L?1 and 13.8 ng · L?1. The proposed method was applied for the determination of PCBs in real river water and rainwater samples. The median recoveries ranged from 85.6% to 118% with RSDs between 4.23% and 8.78%. The experimental results demonstrated that the Ph-MSU fiber coating could be reused for over 250 times without loss of the extraction efficiency. These results clearly indicate that the Ph-MSU coated fiber was rapid, sensitive, and suitable for the preconcentration and determination of trace PCBs in environmental water samples.  相似文献   

6.
A method has been devised combining alkali digestion, carbon chromatography and high-resolution gas chromatography for the determination of 3,3',4,4'-tetra, 3,3',4,4',5-penta, and 3,3',4,4',5,5'-hexachlorobiphenyl, the biologically active congeners of PCBs and approximate isostereomers of 2,3,7,8-TCDD. This method permits determinations of parts-per-trillion levels of these toxic residues in biological samples. Interference both from biogenic and from xenobiotic substances was reduced to extremely low levels. Using this method, 13.5 ng of 3,3'4,4'-tetrachlorobiphenyl/g, 0.89 ng of 3,3'4,4',5-pentachlorobiphenyl/g and 0.64 ng of 3,3',4,4'5,5'-hexachlorobiphenyl/g were detected on wet weight basis in the blubber of a finless porpoise. To our knowledge this is the first report on the three toxic non-ortho chlorine substituted PCB residues detected in a higher mammal in the wilderness.  相似文献   

7.
PCB patterns in a new pigment brand are characterized using GC-MS in the single ion monitoring (SIM) mode. Specific PCBs are then used as external standards for GC-ECD quantification. The following PCB isomers or groups of isomers have to be determined (CB = chlorobiphenyl): total diCBs, 3,3′ diCB, 2,4,5-triCB, 2,2′,4,4′-tetraCB, 2,2′,5,5′-tetraCB, total pentaCB, total hexaCB. Capillary gas chromatography is performed on preseparated solutions (LC) of pigment. An electron caputure detector (ECD) is used for PCB detection and quantification. Calibration is based on the peak areas of external standards and the PCB isomers in the samples, all normalized for internal standard peak areas. Total concentrations of diCB, hexaCB, or pentaCB in a sample are calculated by summing the individual PCB isomer concentrations within the correcsponding elution ranges. Determination limits lie in the range of 1 mg/PCB-isomer/kg pigment.  相似文献   

8.
This study presents the atmospheric pressure photoionization (APPI) of high‐chlorinated (five or more chlorine atoms) polychlorinated biphenyls (PCBs) using toluene as dopant, after liquid chromatographic separation. Mass spectra of PCB 101, 118, 138, 153, 180, 199, 206 and 209 were recorded by using liquid chromatography‐APPI‐tandem mass spectrometry (LC‐APPI‐MS/MS) in negative ion full scan mode. Intense peaks appeared at m/z that correspond to [M ? Cl + O]? ions, where M is the analyte molecule. Furthermore, a detailed strategy, which includes designs of experiments, for the development and optimization of LC‐APPI‐MS/MS methods is described. Following this strategy, a sensitive and accurate method with low instrumental limits of detection, ranging from 0.29 pg for PCB 209 to 8.3 pg for PCB 101 on column, was developed. For the separation of the analytes, a Waters XSELECT HSS T3 (100 mm × 2.1 mm, 2.5 µm) column was used with methanol/water as elution system. This method was applied for the determination of the above PCBs in water samples (surface water, tap water and treated wastewater). For the extraction of PCBs from water samples, a simple liquid–liquid extraction with dichloromethane was used. Method limits of quantification, ranged from 4.8 ng l?1, for PCB 199, to 9.4 ng l?1, for PCB 180, and the recoveries ranged from 73%, for PCB 101, to 96%, for PCB 199. The estimated analytical figures were appropriate for trace analysis of high‐chlorinated PCBs in real samples. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

9.
The rapid determination of three benzophenone‐type UV filters: 2‐hydroxy‐4‐methoxy‐benzophenone (BP‐3), 2,4‐dihydroxybenzophenone (BP‐1) and 2,2′‐dihydroxy‐4‐methoxy‐benzophenone (BP‐8), in aqueous samples is described. The method involved the extraction of an aqueous sample using an Oasis HLB solid‐phase extraction (SPE) cartridge, followed by on‐line derivatization gas chromatography ‐ tandem mass spectrometry (GC‐MS/MS) with a trimethylsilylating (TMS) reagent. This eco‐friendly, injection‐port derivatization method, is sensitive, rapid, and provides reproducible results for these hydroxylated benzophenones in aqueous samples. The limits of quantitation (LOQs) were determined to be 1.0 to 2.5 ng/L for samples in 100 mL of water. The precision for these analytes, as indicated by relative standard deviations (RSDs), proved to be less than 11% for both intra‐ and inter‐day analysis. Accuracy, expressed as the mean extraction yield, was between 80 and 106%. The method was then applied to some environmental water samples, river water and samples of effluents from a wastewater treatment plant (WWTP), having the potential to contain BP‐3 and BP‐1.  相似文献   

10.
This work reports the preparation of molecularly imprinted polymer particles for the selective extraction and determination of four benzophenones from aqueous media. The polymer was prepared by using 4‐vinylpridine as functional monomer, ethylene glycol dimethacrylate as cross‐linker, acetonitrile as porogenic solvent and 2,2’,4,4’‐tetrehydroxybenzophenone as template. Good specific adsorption capacity (Qmax = 27.90 μmol/g) for 2,2’,4,4’‐tetrehydroxybenzophenone was obtained in the sorption experiment and good class selectivity for 2,2’,4,4’‐tetrehydroxybenzophenone, 2,4‐dihydroxybenzophenone, 2,2’‐dihydroxy‐4‐methoxybenzophenone, 2,2’‐dehydroxy‐4,4’‐dimethoxybenzophenone was demonstrated by the chromatographic evaluation experiment. Factors affecting the extraction efficiency of the molecularly imprinted solid‐phase extraction procedure were investigated systematically. An accurate and sensitive analytical method based on the molecularly imprinted solid‐phase extraction coupled with high‐performance liquid chromatography and diode array detection has been successfully developed for the simultaneous determination of four benzophenones from tap water and river water with method detection limits of 0.25–0.72 ng/mL. The recoveries of benzophenones for water samples at two spiking levels (500 and 5000 ng/mL for each benzophenone) were in the range of 86.9–103.3% with relative standard deviations (n = 3) below 9.2%.  相似文献   

11.
A simple and rapid gradient elution high-performance liquid chromatographic method using photodiode array and electrospray ionization mass spectrometric detectors was developed for separation and determination of the process-related substances and photodegradation products of stilbenesulfonic acids, viz. 4,4'-dinitrostilbene-2,2'-disulfonic acid (DNSDA), 4-amino-4'-nitrostilbene-2,2'-disulfonic acid (ANSDA), and 4,4'-diaminostilbene-2,2'-disulfonic acid (DASDA) in industrial waste waters. Gradient elution was carried out using ammonium acetate and acetonitrile as mobile phase and an Inertsil-ODS 3V column for separation. The negative-ion electrospray ionization mass spectra containing [M-H]- ions of sulfonic acids allowed molecular mass determination of unknowns and the structures were proposed on the basis of the fragment ions in the MS/MS spectra.  相似文献   

12.
In this work, solid-phase microextraction (SPME) has been applied as an alternative for the selective extraction of 3 polybrominated diphenyl ethers (PBDEs), 2,2',4,4'-tetrabromodiphenyl ether (PBDE-47); 2,2',4,4',5-pentabromodiphenyl ether (PBDE-99); and 2,2',4,4',6-pentabromodiphenyl ether (PBDE-100), and 2 alkylphenols, 4-tert-OP and 4-NP, prior to their analysis by gas chromatography/mass spectrometry (GC/MS). The advantages of this technique are mainly its simplicity, cost-effectiveness, and time-saving sample preparation, as well as being a solvent-free technique. With the aim of optimizing the conditions for an efficient extraction of the studied compounds, different fiber coatings and the main parameters affecting the extraction procedure have been evaluated. The results obtained showed a good linearity in the range of concentrations investigated, and adequate relative standard deviation values were found according to the range accepted for SPME. Recovery values were in the range of 78-108%, and good detection and quantitation limits at ppt levels were obtained for both methods, allowing the determination of the selected compounds in samples at trace levels. The results obtained clearly show the potential of SPME for efficient concentration of the target compounds and also demonstrate the reliability of this extraction technique for their GC/MS analysis.  相似文献   

13.

A method for determination of trace concentrations of individual PCB congeners in human milk was validated. The analytical procedure included the following steps: acetone : hexane extraction, clean-up of extracts with concentrated sulfuric acid and solid phase extraction (SPE) on Florisil. The identification and quantification of analytes in purified extracts were carried out by high-resolution gas chromatography (HRGC) with electron capture detection (ECD) and/or with low-resolution mass spectrometry (LRMS). Recoveries of 14 PCB congeners from spiked cow milk samples, based on HRGC-ECD were between 87.3 and 93.6%. The precision of analyte determination was established as close to or less than 10%. The detection limits ranged between 0.14 and 0.26 ng/g fat and the quantification limits between 0.57 and 0.86 ng/g fat. The method was linear and characterized by good correlation coefficients (>0.99) for most of the compounds studied. The quality of the method under validation was verified by the analysis of Standard Reference Material (CRM-450) and interlaboratory exercise.  相似文献   

14.
A robust analytical method is presented for the direct determination of polychlorinated biphenyls in soil samples by thermal desorption/gas chromatography/mass spectrometry. The method is simple to perform (thermal desorption and analysis are performed in-line employing a limited amount of sample, 2?mg) and eliminates the need for any solvent and time-consuming extraction. The analytical procedure was optimized using a soil sample spiked with Aroclor 1254 and Aroclor 1260 and validated with a certified industrial soil sample for which the concentration of thirteen PCB congeners are known. Limits of detection were sensitive to matrix effects and varied substantially among analytes. The matrix effect resulted in a reduction of the limits of detection by 1.5–10 times. However, it was found that the matrix effect is not due to ion suppression but to the increase of the noise of selected ion monitoring (SIM) traces, indicating that no limitation exists with using a single surrogate standard. By employing a 13C-labelled PCB internal standard, limits of detection in the range of 0.8 to 10?µg?g?1 of soil were obtained. The obtained experimental results demonstrated that the proposed analytical method can be conveniently applied for screening a large number of heavily contaminated soil samples thus avoiding the employment of harmful solvents and time-consuming extraction procedures.  相似文献   

15.
A QuEChERS method has been developed for the determination of 14 organochlorine pesticides in 14 soils from different Portuguese regions with wide range composition. The extracts were analysed by GC-ECD (where GC-ECD is gas chromatography-electron-capture detector) and confirmed by GC-MS/MS (where MS/MS is tandem mass spectrometry). The organic matter content is a key factor in the process efficiency. An optimization was carried out according to soils organic carbon level, divided in two groups: HS (organic carbon >2.3%) and LS (organic carbon <2.3%). The method was validated through linearity, recovery, precision and accuracy studies. The quantification was carried out using a matrix-matched calibration to minimize the existence of the matrix effect. Acceptable recoveries were obtained (70-120%) with a relative standard deviation of ≤16% for the three levels of contamination. The ranges of the limits of detection and of the limits of quantification in soils HS were from 3.42 to 23.77 μg kg(-1) and from 11.41 to 79.23 μg kg(-1), respectively. For LS soils, the limits of detection ranged from 6.11 to 14.78 μg kg(-1) and the limits of quantification from 20.37 to 49.27 μg kg(-1) . In the 14 collected soil samples only one showed a residue of dieldrin (45.36 μg kg(-1) ) above the limit of quantification. This methodology combines the advantages of QuEChERS, GC-ECD detection and GC-MS/MS confirmation producing a very rapid, sensitive and reliable procedure which can be applied in routine analytical laboratories.  相似文献   

16.
1‐Triacontanol (TA), a member of long chain fatty alcohol, has recently been received great attention owing to its antitumor activity. In this study, an accurate, sensitive and selective gas chromatography–tandem mass spectrometry method was developed and validated for the quantification of TA in beagle plasma using 1‐octacosanal as the internal standard (IS) for the first time. With temperature programming, chromatographic separation was carried out on an HP‐5MS column, using helium as carrier gas and argon as collision gas, both at a flow rate of 1 mL/min. TA was analyzed using positive ion electrospray ionization in multiple‐reaction monitoring mode, with the precursor to product ion transitions of m/z 495.6 → 97.0 and m/z 467.5 → 97.0 for TA and the IS, respectively. The lower limit of quantitation, linearity, intra‐ and interday precision, accuracy, stability, extraction recovery and matrix effect of TA were within the acceptable limits. The validated method was successfully applied to a pharmacokinetic study of TA in beagles. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

17.
An LC-MS method for the determination of picric acid (2,4,6-trinitrophenol), its reductive transformation products picramic acid (2-amino-4,6-dinitrophenol) and iso-picramic acid (4-amino-2,6-dinitrophenol) and hexyl (2,2',4,4',6,6'-hexanitrodiphenylamine) has been developed. The analytes were separated using ion-pairing chromatography with a volatile ion-pairing reagent suitable for subsequent MS detection. The performance of an atmospheric pressure chemical ionisation (APCI) and an electrospray ionisation (ESI) interface was compared. ESI-MS is more sensitive for the analytes, especially for hexyl and picric acid, APCI-MS delivered more fragments necessary for unequivocal identification. With LC-ESI-MS limits of detection using single ion monitoring (SIM) mode are 4 ng (iso-picramic acid), 800 pg (picramic acid), 400 pg (picric acid) and 80 pg (hexyl). For quantification, 15N-picric acid was used as an internal standard. Using this new method, the degradation of picric acid in soil was monitored in a laboratory study. Furthermore, the presence of picramic acid was for the first time verified in soil samples from a former ammunition plant.  相似文献   

18.
The major octabromo isomer of technical octabromo diphenyl ether mixture (technical octaBDE) DE-79 was isolated by RP-HPLC. Three serially coupled columns (each 250 mm long) enabled a good separation of the target compound from other congeners using 100% ACN as eluent. Approximately 100 microg of the target compound was isolated with a purity of >90% and investigated by MS for confirmation of the degree of bromination. 1H-NMR and 2-D 1H-13C correlation NMR spectra unequivocally clarified that the octaBDE in question is 2,2',3,3',4,4',6,6'-octabromodiphenyl ether (BDE 197). Based on annual production rates of technical BDE products (1999/2001), approximately 380 tons of BDE 197 were annually produced which, on the long term, may enter the environment. Compared with other individual BDE congeners, BDE 197 has the seventh highest application rate. Reductive debromination of BDE 197 can lead to four hepta-, 15 hexa-, 23 penta-, and 28 tetra-BDE isomers, respectively. This variety includes all known major BDEs of environmental concern (BDE 47, 85, 99, 100, 153, 154, and 183). The identification of BDE 197 in technical octaBDE DE-79 strongly suggests that research on the environmental fate of BDEs should include this key-BDE congener.  相似文献   

19.
Environmental toxicants that interfere with thyroid hormone (TH) signaling can impact growth and development in animals and humans. Zebrafish represent a model to study chemically induced TH disruption, prompting the need for sensitive detection of THs. Simultaneous quantification of 3,3′,5‐triiodo‐l ‐thyronine (T3), thyroxine (T4), 3,3′,5′‐triiodo‐l ‐thyronine (rT3), 3,5‐diiodo‐l ‐thyronine (3,5‐T2) and 3,3′‐diiodo‐l ‐thyronine (3,3′‐T2) in zebrafish larvae was achieved by ultra‐performance liquid chromatography–tandem mass spectrometry in positive ion mode. Solid‐phase extraction with SampliQ cartridges and derivatization with 3 m hydrochloric acid in n‐butanol reduced matrix effects. Derivatized compounds were separated on an Acquity UPLC BEH C18 column with mobile phases consisting of 0.1% acetic acid in deionized water and 0.1% acetic acid in methanol. The limits of detection ranged from 0.5 to 0.6 pg injected on column. The method was validated by evaluating recovery (77.1–117.2%), accuracy (87.3–123.9%) and precision (0.5–12.4%) using diluted homogenized zebrafish embryos spiked with all target compounds. This method was then applied to zebrafish larvae collected after 114 h of exposure to polychlorinated biphenyls (PCBs), including PCB 28, PCB 66 and PCB 95, or the technical mixture Aroclor 1254. Exposure to PCB 28 and PCB 95 increased the T4:T3 ratio and decreased the T3:rT3 ratio, demonstrating that this method can effectively detect PCB‐induced alterations in THs.  相似文献   

20.
A novel series of 2,2-dialkyl-1'-(N-substituted aminoalkyl)-spiro-[chroman-4,4' -imidazolidine]-2',5'-diones was synthesized and evaluated for antiarrhythmic activity in chloroform- or/and aconitine-induced ventricular arrhythmia in mice. Among these compounds, (-)-6-chloro-2,2-dimethyl-1'-[3-(4-hydroxypiperidino)propyl] -spiro-[chroman-4,4'-imidazolidine]-2',5' -dione was found to be more effective than reference agents and was selected for further development.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号