 共查询到20条相似文献,搜索用时 31 毫秒
1.
A high-performance liquid chromatography (HPLC) system using a porous graphitic carbon (PGC) stationary phase interfaced with an electrospray ionization (ESI) source and a tandem mass spectrometer (MS/MS) for the analysis of cytarabine (ara-C) in mouse plasma samples has been developed in support of a pharmacodynamic study. The graphitized carbon column was adopted for the separation of ara-C and endogenous peaks from mouse plasma samples under the reversed-phase phase mode in liquid chromatography. The retention characteristics of the PGC column and the ionization efficiencies of all analytes based on the experimental factors such as the composition of mobile phases were investigated. The potential of ionization suppression resulting from the endogenous biological matrices on the PGC column during HPLC/ESI-MS/MS was investigated using post-column infusion. The concentrations of ara-C in mouse plasma obtained by using PGC-HPLC/MS/MS and ion-pairing HPLC/MS/MS were found to be in good agreement in terms of analytical accuracy.  相似文献   

2.
A method using zirconia-based column high-performance liquid chromatography (HPLC) interfaced with an atmospheric pressure photoionization (APPI) source and a tandem mass spectrometer (MS/MS) was developed for the quantitative determination of new chemical entities in rat plasma in support of pharmacokinetics studies. The ionization suppression resulting from endogenous components of the biological matrices on the quantitative zirconia-based column HPLC/APPI-MS/MS method was investigated using the post-column infusion technique. The analytical results for 'rapid rat pharmacokinetics' for 12 drug discovery compounds, obtained by both silica-based phase (S-phase) and zirconia-based phase (Z-phase) chromatographic separation, are in good agreement in terms of accuracy. The application of a Z-phase column for high-temperature fast HPLC/MS/MS methods was explored to reduce the analysis time from 3 min to 30 s for column temperatures of 25-110 degrees C, respectively. The chromatographic retention times and peak responses of all analytes were found to be reproducible under high-temperature conditions following 100 continuous injections, with %CV less than 0.4 and 5, respectively.  相似文献   

3.
A hydrophilic interaction chromatographic (HILIC) system interfaced with atmospheric pressure ionization (API) sources and a tandem mass spectrometer (MS/MS) was developed for the simultaneous determination of nicotinic acid (NiAc) and its metabolites in dog plasma in support of a pharmacokinetic study. A silica column was adapted for separation of NiAc and its two metabolites, nicotinamide (NiNH2) and nicotinuric acid (NiUAc), under HILIC conditions. The influence of experimental factors such as the composition of mobile phase on ionization efficiency and chromatographic performance of all analytes was investigated. The feasibility of the proposed HILIC/MS/MS methods was explored by comparing the plasma levels of NiAc, NiNH2, and NiUAc in dog obtained by using either electrospray ionization or atmospheric pressure chemical ionization interfaces in positive ion mode. The methods were partially validated in terms of inter-day accuracy and precision, extraction recovery, benchtop and freeze/thaw stability. Further, the potential of ionization suppression resulting from endogenous components of the biological matrixes on the HILIC/API-MS/MS methods were investigated using the post-column infusion technique.  相似文献   

4.
Ion-pairing high performance liquid chromatography (IP-HPLC) was utilized to monitor the composition changes of blue gel pen ink entries on paper stored in different light conditions and natural environment. The chromatographic conditions were optimized by comparing the separation efficiencies of the blue gel pen inks using a series of ion-pairing reagents, including ammonium carbonate, ammonium acetate, triethylamine acetate, tributylamine acetate, tetrabutylammonium bromide and dihexylammonium acetate. It has been found that tributylamine acetate was a suitable ion-pairing reagent for separation of the inks on the common C18 column. The analysis results of the ink entries on paper in different aging conditions showed that the tendency of composition change in natural aging condition was similar with those in fluorescent light and UV light conditions, respectively. One main component dye of the blue gel pen ink, Acid Blue 9, and its degradation products were identified by ion-pairing high performance liquid chromatography coupled with electrospray tandem mass spectrometry. The results showed that the main degradation products originated from the Acid Blue 9. It gave a reasonable explanation for the changing rules of the relative content of the dyes in the blue gel pen ink. The results obtained can provide scientific evidences for dating of the blue gel pen ink entries on documents.  相似文献   

5.
Currently available high-performance liquid chromatographic assays for cytosine arabinoside (ara-C) and its metabolites suffer from two major shortcomings: inability to resolve both ara-C and its nucleotides in a single chromatographic step and/or inadequate sensitivity to allow quantitation of intracellular cytosine arabinofuranoside-5'-triphosphate (ara-CTP) without the use of radiolabelled drug. In this paper, we describe a new ion-pairing high-performance liquid chromatographic assay for ara-C in biological samples that can separate ara-C from its nucleotides, metabolites, and naturally occurring ribonucleotides in a single chromatographic step with a lower limit of quantitation of 5 pmol for ara-C and 10 pmol for ara-CTP. Examples of the utility of this assay are shown in studies of intracellular pharmacokinetics of ara-C in cultured human breast cancer cells and in analysis of plasma nucleoside levels in patients receiving high-dose thymidine chemotherapy. We conclude that this assay provides a rapid and versatile system that can be applied to the study of both cellular and plasma nucleoside pharmacokinetics.  相似文献   

6.
A fast, simple and sensitive liquid chromatography/tandem mass spectrometry (LC/MS/MS) method was developed for the determination of acetylcholine in rat brain microdialysis samples. The chromatographic separation was achieved in 3 min on a reversed-phase column with isocratic conditions using a mobile phase containing 2% (v/v) of acetonitrile and 0.05% (v/v) of trifluoroacetic acid (TFA). A stable isotope-labeled internal standard was included in the analysis and detection was carried out with a linear ion trap mass spectrometer using selected reaction monitoring (SRM). Analyte ionization was performed with an atmospheric pressure chemical ionization (APCI) source without applying discharge current (atmospheric pressure spray ionization). This special ionization technique offered significant advantages over electrospray ionization for the analysis of acetylcholine with reversed-phase ion-pairing chromatography. The lower limit of quantification was 0.15 nM (1.5 fmol on-column) and linearity was maintained over the range of 0.15-73 nM, providing a concentration range that is significantly wider than that of the existing LC/MS methods. Good accuracy and precision were obtained for concentrations within the standard curve range. The method was validated and has been used extensively for the determination of acetylcholine in rat brain microdialysis samples.  相似文献   

7.
8.
An ultrafast bioanalytical method using monolithic column high-performance liquid chromatography/tandem mass spectrometry (HPLC/MS/MS) was evaluated for the simultaneous determination of a drug discovery compound and its metabolite in plasma. Baseline separation of the two compounds was achieved with run times of 24 or 30 s under isocratic or gradient conditions, respectively. The monolithic column HPLC/MS/MS system offers shorter chromatographic run times by increasing flow rate without sacrificing separation power for the drug candidate and its biotransformation product (metabolite). In this work, the necessity for adequate chromatographic resolution was demonstrated because the quantitative determination of the drug-related metabolism product was otherwise hampered by interference from the dosed drug compound. The chromatographic performance of a monolithic silica rod column as a function of HPLC flow rates was investigated with a mixture of the drug component and its synthetic metabolite. The assay reliability of the monolithic column HPLC/MS/MS system was checked for matrix ionization suppression using the post-column infusion technique. The proposed methods were successfully applied to the analysis of study rat plasma samples for the simultaneous quantitation of both the dosed drug and its metabolite. The analytical results obtained by the proposed monolithic column methods and the 'standard' silica particle-packed HPLC column method were in good agreement, within 10% error.  相似文献   

9.
黄永鹏  唐慧  宋云扬  陈博  钟辉 《色谱》2021,39(7):695-701
维库溴铵、罗库溴铵和泮库溴铵是一类广泛使用的非去极化肌松剂,使用过程中引起过敏反应甚至死亡的情况时有发生,快速检测血液中该类肌松剂的浓度,可为临床早期诊断提供有价值的信息。该类肌松剂为强极性的季铵盐类化合物,在反相色谱柱上难以保留,主要采用离子对色谱法进行分离。采用离子对色谱法时,加入的离子对试剂有离子抑制作用,可降低质谱灵敏度,还会污染质谱系统。该文建立了高效液相色谱-串联质谱(HPLC-MS/MS)同时检测血液中3种季铵盐类肌松剂的检测方法。血液样品经稀释、高速离心后,上清液过Bond Elut AL-N固相萃取柱净化,用0.45 μm的微孔滤膜过滤后检测。采用ZIC-cHILIC色谱柱(50 mm×2.1 mm, 3.0 μm)分离,以乙腈和0.1%甲酸水溶液为流动相,梯度洗脱,在ESI+、多反应检测(MRM)模式下检测。3种季铵盐类肌松剂在血液中的基质效应为88.1%~95.4%,在各自范围内线性关系良好,相关系数(R2)均大于0.996,检出限为0.2~0.8 ng/mL,定量限为0.5~2.0 ng/mL,加标回收率为92.8%~110.6%,相对标准偏差(RSD)为3.2%~9.4%。该方法灵敏度高,准确性好,操作简便,可用于血液样品中维库溴铵、罗库溴铵和泮库溴铵的快速检测。  相似文献   

10.
A higher-throughput bioanalytical method based on fast-gradient (1 min run time) high-performance liquid chromatography (HPLC) coupled with tandem mass spectrometry (MS/MS) was developed for screen-type analyses of plasma samples from early drug discovery studies in support of exploratory pharmacodynamic studies. The HPLC system equipped with minibore column was interfaced with either atmospheric pressure chemical ionization (APCI) or electrospray (ESI) ionization techniques. The matrix ion suppression effect of both quantitative HPLC/MS/MS analyses was compared using the post-column infusion system. The use of the described methods provided advantages such as a shorter chromatographic region of ion suppression, less solvent consumption and shorter run times in comparison with standard analytical column HPLC/MS/MS methods. The analytical results obtained by both HPLC/MS/MS methods were in good agreement (within 15% of error) and displayed a good correlation with the pharmacodynamic outcome.  相似文献   

11.
Ultra‐performance hydrophilic interaction liquid chromatography (UPHILIC) interfaced with the electrospray ionization (ESI) source of a tandem mass spectrometer (MS/MS) was developed for the simultaneous determination of everolimus in mouse plasma samples. UPHILIC was performed on a sub‐2 µm bare silica particle packing with the column pressure under traditional high‐performance liquid chromatography (HPLC) to allow fast separation of pharmaceutical compounds within a chromatographic analysis time of 1 min. This UPHILIC technology is comparable with reversed‐phase ultra‐performance liquid chromatography (RPUPLC) in terms of chromatographic efficiency but demands neither expensive ultra‐high‐pressure instrumentation nor new laboratory protocols. With the ESI source, multiple reaction monitoring (MRM) of the ammoniated adduct ions of the analyte was used for tandem mass spectrometric detection. The retention mechanism profiles of the test compounds under HILIC conditions were explored. The influences of experimental factors such as the compositions of mobile phases on the chromatographic performance and the ionization efficiency of the test compounds in positive ion mode were investigated. A UPHILIC/MS/MS approach following a protein precipitation procedure was applied for the quantitative determination of everolimus at the low ng/mL region in support of a pharmacodynamic study. The analytical results obtained by the UPHILIC/MS/MS approach were fond to be in good agreement with those obtained by the RPUPLC/MS/MS method in terms of assay sample throughput, sensitivity and accuracy. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

12.
Ionization efficiency (IE) in mass spectrometry (MS) has been studied for many different compounds, and different IE scales have been constructed in order to quantitatively characterize IE. In the case of MS, derivatization has been used to increase the sensitivity of the method and to lower the limits of detection. However, the influence of derivatization on IE across different compounds and different derivatization reagents has not been thoroughly researched, so that practitioners do not have information on the IE‐enhancing abilities of different derivatization reagents. Moreover, measuring IE via direct infusion of compounds cannot be considered fully adequate. Since derivatized compounds are in complex mixtures, a chromatographic method is needed to separate these compounds to minimize potential matrix effects. In this work, an IE measurement system with a chromatographic column was developed for mainly amino acids and some biogenic amines. IE measurements with liquid chromatography electrospray ionization mass spectrometry (LC/ESI/MS) were carried out, and IE scales were constructed with a calibration curve for compounds with and without derivatization reagent diethyl ethoxymethylenemalonate. Additionally, eluent composition effects on ionization were investigated. Results showed that derivatization increases IE for most of the compounds (by average 0.9 and up to 2‐2.5 logIE units) and derivatized compounds have more similar logIE values than without derivatization. Mobile phase composition effects on ionization efficiencies were negligible. It was also noted that the use of chromatographic separation instead of flow injection mode slightly increases IE. In this work, for the first time, IE enhancement of derivatization reagents was quantified under real LC/ESI/MS conditions and obtained logIE values of derivatized compounds were linked with the existing scale.  相似文献   

13.
A rapid, sensitive, and simple gas chromatographic method with flame ionization detection is developed for the simultaneous determination of tetramethylpyrazine phosphate (TMPP) and borneol in mouse plasma and brain tissue. Sample preparations are carried out by deproteinization with an internal standard solution in methanol. The analytes and internal standard (dimethyl sulfoxide) are well-separated on an HP-5 MS capillary column. The analytical curves are linear over a wide concentration range of 0.02-40 microg/mL for both TMPP and borneol in plasma and brain tissue, with the intra- and inter-day precision (the relative standard deviation values) at less than 15%. TMPP and borneol are both stable under different conditions. The method described is successfully applied to the pharmacokinetic study of mouse plasma and brain tissue after oral administration of the Fufang TMPP and TMPP tablets to mice.  相似文献   

14.
Seventy-six molecules of biological interest for the diagnosis of inherited disorders of amino acids (AA) metabolism have previously been demonstrated to be detectable in electrospray ionization tandem mass spectrometry (ESI-MS/MS) positive mode without derivatization. Reversed-phase liquid chromatography (RPLC) separation on different C18 columns using various perfluorinated carboxylic acids as ion-pairing agents has been found suitable for coupling with MS/MS, and for the separation of AA. A new procedure was optimized in order to replace the usual ion-exchange chromatographic, post-column ninhydrin derivatization, time-consuming routine method. This procedure allowed an adequate separation of all the molecules from other known interfering compounds, and a throughput of two samples per hour. Quantification limits for each molecule were found to be compatible with their measurement in plasma and urine. We validated the qualitative part of the method by analyzing plasma and urine samples from patients affected with several inherited disorders of AA metabolism. We validated the quantification of 16 AA using their stable isotopes as internal standard. The calibration curves were linear over the range 0-3 mM. The quantitative results obtained with the new method on 105 plasma and 99 urine samples were in good agreement with those obtained by the established routine method. Spiking experiments and precision results were also satisfactory.  相似文献   

15.
Hydrophilic interaction liquid chromatography (HILIC) interfaced with atmospheric pressure ionization (API) sources and a tandem mass spectrometer (MS/MS) was developed for the simultaneous determination of dasatinib, imatinib and nilotinib in mouse plasma samples. The retention profiles of all analytes on several silica stationary phases under HILIC conditions were explored. The influences of experimental factors such as the compositions of mobile phases on the chromatographic performance and the ionization efficiency of all analytes in positive ion mode were investigated. The applicability of the proposed HILIC/MS/MS approach following a protein precipitation procedure for the quantitative determination of dasatinib, imatinib and nilotinib at low nano‐mole levels was examined with respect to assay specificity and linearity. The analytical results obtained by various HILIC/MS/MS approaches were found to be in good agreement with those obtained by reversed‐phase liquid chromatography/tandem mass spectrometry (RPLC/MS/MS) methods in terms of assay sample throughputs, sensitivity and accuracy. Furthermore, the potential of matrix ionization suppression on the proposed HILIC/MS/MS systems was investigated using the post‐column infusion technique. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

16.
The analytical performances of two triple-quadrupole instruments, which differ in their atmospheric-pressure sources, were evaluated for native amino acid analysis. The Applied Biosystems/Sciex API 300 instrument was equipped with a turboIon Spray source and a curtain gas interface while the Waters/Micromass Quattro Ultima instrument was characterized by its Z-spray source. Liquid chromatography/mass spectrometry analysis of native amino acids requires volatile ion-pairing mobile phase additives (mainly perfluorinated carboxylic acids). The effects of the structure and concentration of the ion-pairing reagents as well as the organic modifier percentage on the electrospray response of amino acids were studied in detail. The most favourable chromatographic conditions depend strongly on the mass spectrometer used. Several instrumental parameters were also studied, including spray voltage, transmission lens voltages, temperature of desolvation and auxiliary gas flow rates. The results show substantial qualitative differences depending on the instrument geometry. The quantitative performances of the two triple-quadrupole mass spectrometers were evaluated in terms of limits of detection and quantification. The effects of the matrix on the analyte ionization were also examined, and the long-term stability of the electrospray performance was studied over 12 h using a mobile phase containing the perfluorinated ion-pairing reagents. The study provides information on the robustness of the MS instrument and its detection sensitivity towards native amino acid analysis. It appears that each instrument has its good and bad points since one provides higher sensitivity while another is more robust.  相似文献   

17.
An automated high-throughput HPLC/MS/MS method was developed for the quantitative determination of pantoprazole in human plasma. Only 100 microL plasma was placed in 2.2 mL 96 deep-well plates, and both pantoprazole and omeprazole (IS) were extracted from human plasma by liquid-liquid extraction, using diethyl ether-dichloromethane (70:30, v/v) as the organic solvent. Robotic liquid-handling workstations were used for all liquid transfer and solution preparation steps and resulted in a short sample preparation time. After vortexing, centrifugation, and freezing, the supernatant organic solvent was evaporated and reconstituted in a small volume of reconstitution solution. Sample analysis was performed by utilizing the combination of RP-HPLC/MS/MS, with positive-ion electrospray ionization and multiple reaction monitoring detection. The chromatographic run time was set at 1.8 min with a flow rate of 0.6 mL/min on a Nucleosil octylsilyl (C8) analytical column. The method was proven to be sensitive, specific, accurate, and precise for the determination of pantoprazole in human plasma. The method was applied to a bioequivalence study after per os administration of a 40 mg pantoprazole gastric retentive tablet.  相似文献   

18.
For the detection of anabolic steroid residues in bovine urine, a highly sensitive liquid chromatographic/electrospray ionization tandem mass spectrometric (LC/ESI-MS/MS) method was developed using both positive and negative ionization. For four compounds the ESI mode was not sensitive enough and gas chromatographic/mass spectrometric GC/MS detection was therefore still necessary as a complementary method. The sample clean-up consisted of solid-phase extraction (SPE) on a C(18) column followed by enzymatic hydrolysis and a second solid-phase extraction on a combination of a C(18) and a NH(2) column. After this last SPE clean-up, the eluate was split into two equal aliquots. One aliquot was further purified and after derivatization used for GC/MS analysis. The other aliquot was analyzed with LC/MS/MS in both ESI+ and ESI- modes. The method was validated according to the European Commission Decision 2002/657/EC. Decision limits (CCalpha) were between 0.16 and 1 ng ml(-1) for the compounds detected with the LC/MS/MS method. The developed method is used in routine analysis in our laboratory.  相似文献   

19.
A liquid chromatography/tandem mass spectrometry (LC/MS/MS) method was developed and validated to determine the concentrations of adefovir [9-(2-phosphonylmethoxyethyl)adenine, PMEA] in human plasma. After one-step protein precipitation of plasma samples by methanol, adefovir was analyzed by LC/MS/MS using positive electrospray ionization. Chromatography was performed on a C18 column. The extraction recoveries of adefovir were found to be 85.1-89.3%. Adefovir was stable under routine laboratory conditions. A minimal matrix effect resulting in a slight ionization enhancement of adefovir (<10.9%) was observed, which did not markedly affect the behavior of the calibrations curves and accuracy and precision data. The method had a chromatographic run time of 7.8 min and a linear calibration curve over the concentration range 1.5-90 ng/mL for adefovir. The lower limit of quantification of the method was 1.5 ng/mL. The intra- and inter-day precision was less than 8.4%. These results indicated that this LC/MS/MS method has high selectivity and efficiency, and acceptable accuracy, precision and sensitivity. The validated LC/MS/MS method has been successfully used in a pharmacokinetic study in healthy volunteers treated with oral adefovir dipivoxil at 10 and 20 mg.  相似文献   

20.
A detailed analytical study on ethephon residue determination in water, making use of ion-pairing liquid chromatography coupled to electrospray tandem mass spectrometry (LC/MS/MS), has been carried out. Ethephon is a plant growth regulator, highly polar, which is typically present in aqueous solution in anionic form due to its acid character. Both its extraction and pre-concentration from water samples and its chromatographic retention are difficult. Several approaches for sample pretreatment have been tested including direct injection into the chromatographic system, on-line solid phase extraction (SPE) and off-line SPE, with the best results being obtained after off-line SPE, using Oasis MAX cartridges (mixed-mode strong anion-exchange). After testing several ion-pairing reagents, tetrabuthylammonium acetate (TBA) was selected. This was added to the samples before LC/MS/MS analysis to facilitate ethephon chromatographic retention. The acquisition of several specific MS/MS transitions together with the evaluation of their relative intensity ratios allowed the reliable confirmation of the analyte in samples. The optimised approach was tested in low-salinity water spiked at 0.1?µg?L?1 level with satisfactory recovery, and a limit of detection of 0.02?µg?L?1. To this purpose, the water sample was partially de-ionised in an initial stage, in order to remove major ions that would have interfered in analyses. The application of this methodology to more saline/complex water samples, as surface or wastewater, was problematic and a thorough optimisation of the de-ionisation conditions would be required.  相似文献   