首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 65 毫秒
1.
Summary The different methods for the determination of vitamin E in all types of biological materials are reviewed. The following subjects are dealt with: isolation of the vitamin from biological samples, foodstuffs and pharmaceuticals; instrumental aspects (injection, reversed-phase HPLC, straight-phase HPLC); standardization; detection limits.
Bestimmung von Vitamin E in verschiedenen biologischen Proben durch HPLC
Zusammenfassung Die Übersicht behandelt folgende Aspekte: Isolierung des Vitamins aus biologischem Material, Lebensmitteln und Pharmazeutica; instrumentelle Probleme (Injektion, reversed-phase und straight-phase HPLC); Standardisierung; Nachweisgrenzen.
  相似文献   

2.
Chromatographic analysis of tocol-derived lipid antioxidants   总被引:7,自引:0,他引:7  
This paper provides a comprehensive overview of existing chromatographic methods for the analysis of tocol-derived lipid antioxidants in various sample matrices. After a brief introductory discussion on biological and nutritional aspects of the vitamin E active compounds, the review focuses on various techniques for the isolation, purification, chromatographic separation, and detection of tocopherols and tocotrienols. Compiled published normal-phase (NP) and reversed-phase (RP) high-performance liquid chromatographic (HPLC) methods demonstrate general trends and analytical variability and versatility of HPLC methodology. The relative merits of the two HPLC methods are assessed. NP and RP elution characteristics are delineated to aid in the identification of antioxidant components. Technical novelty of certain analytical procedures for non-food samples warrants their inclusion in this review in light of the potential applicability in food assays.  相似文献   

3.
Abstract

A reversed phase high-performance liquid chromatography (HPLC) has been developed for the quanititive determination of retinol acetate (vitamin A-acetate) in pharmaceutical formulations and biological materials. The extraction of vitamin A-acetate from capsules and dragees and from blood is performed in a fully automated, electronically controlled extraction apparatus within 3–10 minutes. For reversed phase HPLC a column of LiChrosorb RP18 and methanol as eluent were used. Vitamin A-acetate was separated in less than 1 minute. The detection limit was 1-2 ng. The described methods were proved useful for extraction and determination of vitamin A-acetate in pharmaceutical preparations such as capsules and dragees and in blood, and can be well reproduced with a maximum coefficient of variation of <4%.  相似文献   

4.
The goal of this paper is to optimize the pressurized liquid extraction (PLE) of vitamin E from grape seed oil from residues of the wine industry. For this purpose an experimental planning to optimize the extraction of Brazilian grape seed oil by means of PLE with hexane as solvent was applied and the results are compared with conventional methods (Soxhlet and mechanical press extraction). Vitamin E was separated and analyzed using HPLC with UV detection. This study demonstrates the ability of the PLE in extracting grape seed oil rich in vitamin E.  相似文献   

5.
Abstract

A reversed phase high-performance liquid chromatographic method (HPLC) is described for separation and determination of colecalciferol (Vitamin D3) in Vitamin preparations and in biological materials. Vitamin D3 is extracted from the formulations and from the blood in a fully automated electronically controlled extraction apparatus. For HPLC a column of lichrosorb RP18 and methanol as eluent are used. The extraction, separation and determination of vitamin D3 needs about 10–20 minutes. The described extraction and HPLC methods allow the detection of 1–2 ng per injection and are well reproduced with a maximum coefficient of variation of < 3,5%. Vitamin A-acetate is used as internal standard.  相似文献   

6.
A high performance liquid chromatographic (HPLC) procedure has been developed for the analysis of ascorbic acid and dehydroascorbic acid in complex matrices. Separation is accomplished with an anion-exchange resin and fluorescent detection is achieved through post-column inline chemistry, involving oxidation of ascorbic acid to dehydroascorbic acid followed by reaction with o-phenylenediamine to form a fluorescent product. Lower limits of detection for both forms of vitamin C are well below the levels found in the usual food sources of this vitamin. The extraction procedures developed yield clean samples for analysis with minimal loss of the vitamers during the analytical procedures. Recoveries are in the range of 90-107%. The results obtained with this HPLC procedure agree well with those obtained with a modified version of the classical procedure of Deutsch and Weeks. A variety of foods including fruit juices, vegetables, and fruits were analyzed.  相似文献   

7.
Using a two-step sample preparation with Extrelut and silica gel extraction in Pasteur pipettes it is possible to quantify all tocopherols in human serum samples by means of normal-phase HPLC with fluorescence detection (lambda(ex) 295 nm, lambda(em) 330 nm) or by GC-MS of their trimethylsilyl (TMS) derivatives. The method has been used in pharmacoepidemiological studies concerning the exposition with vitamin E-containing drugs in Germany. The recovery for all tocopherols is 98% and the limit of detection is 50 pg for alpha-tocopherol in the HPLC and 40 pg for all TMS-tocopherols in the GC-MS method using the selected ion monitoring mode with a well-tuned GCQ system. Linearity of calibration is excellent for both methods over the full physiological relevant range. Due to the low sample amount needed, the method is suitable for epidemiological and paediatric research.  相似文献   

8.
This study reports the optimization of a method for the determination of vitamin E and carotenoids in shells of Chionoecetes opilio samples by online HPLC coupled with UV-vis and fluorescence detectors. The carotenoids were determined with diode-array detector (lambda 450 nm) and vitamin E with fluorescence detection (lambda(ex) 288, lambda(em) 331 nm). Two extractions methods were compared, saponification followed by an extraction step and a simple extraction with acetone. The last one was selected because allows to determine all compounds. Linearity, precisions and recoveries achieved for all compounds were satisfactory. Mean concentrations (mg per 100 g dry weight) were; 23.3 for vitamin E, 9.49 for astaxanthin and 0.2 mg for beta-carotene.  相似文献   

9.
The role of high-performance liquid chromatography (HPLC) in methods of analysis for anabolic compounds in biological samples is reviewed. Special attention is given to both the separation and detection of anabolic compounds. A distinction is made between on-line detection systems, such as ultraviolet detection and diode-array detection, and off-line detection methods with special emphasis on immunochemical detection methods using non-isotopic labels. A number of applications are given to elucidate the possibilities of HPLC in the analysis of anabolic compounds.  相似文献   

10.
A simple, rapid, and reproducible reversed-phase high-performance liquid chromatographic (HPLC) method is applied to the routine assay of vitamin E acid succinate in biodegradable microspheres. Vitamin E acid-succinate-containing poly-(D,L-lactic-co-glycolic acid) microspheres are prepared by the solvent evaporation method. The starting drug-polymer ratio is 1:10 (w/w) and the total amount of drug and polymer processed is always 440 mg. The content of vitamin E acid succinate in the microspheres is evaluated by HPLC. Chromatography is carried out isocratically at 25 degrees C +/- 0.5 degrees C on an Extrasil ODS-2 column with a mobile phase composed of methanol-water (97:3, v/v) (pH 5.6) at a flow rate of 2 mL/min and UV detection at 284 nm. Parameters such as linearity, limits of quantitation (LOQ) and detection (LOD), precision, accuracy, recovery, specificity, and ruggedness are studied as reported in the International Conference on Harmonization guidelines. The stability of vitamin E acid succinate is also studied with satisfactory results after 48 h at 25 degrees C. The method is selective and linear for drug concentrations in the range 15-210 micro g/mL. The LOQ and LOD are 15 and 3 micro g/mL, respectively. The results for accuracy studies are good. Values for coefficient of variation for intra- and interassay are 2.08% and 2.32%, respectively. The mean percentage of vitamin E acid succinate in the recovery studies is 99.52% +/- 0.81%. The mean loading efficiency for microspheres is 96.53% +/- 1.31%.  相似文献   

11.
A universal extraction procedure is described for fat-soluble vitamins in human serum. Methods are presented for routine quantitative analysis by isocratic straight phase HPLC with UV-detection of (alpha + beta)-carotene, vitamin E (alpha-tocopherol) and vitamin A (all-trans-retinol) in one single run, and of vitamin K1 (trans-phylloquinone) and 25-hydroxy vitamin D3 after sample clean-up using disposable reversed-phase cartridges. The limits of detection, precisions and selectivities of the developed assays are shown to be satisfactory after more than three years' experience. The routine clinical determination of fat-soluble vitamins can be performed in less than 5 mL of serum. Analyses of external quality control and randomly taken outpatient samples are shown to be of great value in assessing laboratory performance.  相似文献   

12.
New methods are presented for measuring total vitamin C and the ascorbic acid/dehydroascorbic acid ratio in gastric juice. Extracts are prepared from a gastric juice which are suitable for direct injection onto a Waters Nova-pak C18 Radial-pak cartridge for high performance liquid chromatography (HPLC) using ultraviolet absorbance at 270 nm for detection. Both enable removal of interfering mucus and mucopolysaccharide breakdown products in a novel way. The first uses mini-columns of Sephadex G-50, run in acidic conditions to remove large molecular weight material while maintaining the ascorbic acid/dehydroascorbic acid ratio as it was in the fresh sample. Addition of dithiothreitol converts the dehydroascorbic acid quantitatively to ascorbic acid, thus enabling measurement of both components. The second method converts all the dehydroascorbic acid to ascorbic acid at the outset. A perchloric acid extract is neutralized and passed through a Sep-Pak C18. A new internal standard, reductic acid, is introduced for ascorbic acid analysis which behaves identically on Sep-Pak C18. Samples are analysed by ion-pair chromatography using 0.02 M NH4H2PO4 buffer (pH 7.1): methanol (80:20 v/v) containing 0.62 g/L tetrapentylammonium bromide. The detection limit was 1 ng ascorbic acid, and chromatography was completed in 5 min. The values obtained by the two independent HPLC methods were in good agreement with each other and with those obtained by the 2,4-dinitrophenylhydrazine colorimetric method.  相似文献   

13.
A novel method for the determination of vitamin B12 by high-performance liquid chromatography with fluorescence detection is reported. The method was simple and highly sensitive with good precision. Vitamin B12 was analyzed by HPLC on a muBondapak C18 column (300x3.9 mm, 10 microm) with methanol-water (30:70) as mobile phase and fluorescence detection at 305 nm (with excitation at 275 nm). The calibration graph was linear from 1.000 to 100.0 ng ml(-1) for vitamin B12 with a correlation coefficient of 0.998 (n=6). The detection limit was 0.1 ng ml(-1). The method was successfully applied to the determination of vitamin B12 in vitamin B12 tablets, multivitamin tablets and fermentation medium. The recovery was from 94 to 102% and the relative standard deviation was in the range of 1.8 to 4.1%.  相似文献   

14.
HPLC using fluorescence detection has already become the most accepted method for the determination of aflatoxins due to its several advantages over other analytical methods. Both normal- and reversed-phase HPLC can be used. However the reversed-phase HPLC methods are more popular. Liquid chromatographic determination of aflatoxins using fluorescence detection and its application in food analysis is reviewed in this article.  相似文献   

15.
A method is proposed for the determination of vitamin K1 concentration in blood serum using HPLC on a Gemini C18 (250 mm × 4.6 mm ID, 5 μm) column and elution with a methanol–acetonitrile–dichloromethane (45 : 50 : 5, v/v) mobile phase at a flow rate of 1 mL/min and detection at 248 nm. The limit of detection for the vitamin is 0.5 ng/mL and relative error is 19%. The volume of sample in the column is 100 μL. The method has been applied to the evaluation of vitamin K1 deficit in a human body in medical practice.  相似文献   

16.
Determination of small amounts of vitamin K1 (0.8 microg/g) in nutritional supplements with high fat content (20 mg/g) was performed by solid-phase extraction and high-performance liquid chromatography (HPLC) with fluorescence detection after reduction on a platinum oxide catalyst. The concentration ratio of plant oils to vitamin K1 (0.8 microg/g) was about 25,000:1. A sample solution was applied to a solid-phase extraction cartridge and vitamin K1 was eluted with ethanol, followed by HPLC. The proposed method was simple, rapid (analysis time: ca. 12 min), sensitive [detection limit: ca. 0.1 pg per injection (100 microl) at a signal-to-noise ratio of 3:1], highly selective and reproducible [relative standard deviation: ca. 1.3%. (n=5)]. The calibration graph of vitamin K1 was linear in the range of 0-2 pg per injection (100 microl). Recovery of vitamin K1 was over 90% by the standard addition method.  相似文献   

17.
Summary The application of HPLC to environmental analysis is often hindered by difficulty not experienced in other areas of analysis. Usually the components being determined are at parts per million levels or less and are usually in sample matrices that can yield many interferences. In order to develop successful methodology the prime requirements for an HPLC system are column efficiency and the sensitivity and selectivity of the detection system. In this presentation, examples are given to illustrate how HPLC can be used to advantage by comparing it to gas chromatographic (GC) methods and even TLC methods. For many classes of compounds, such as halogenated hydrocarbons (pesticides, PCB’s, dioxins), the GC methods may be preferred. However, for polycyclic aromatic hydrocarbons (PAH) HPLC with fluorescence detection has proven to be excellent for trace environmental analysis. Comparisons of HPLC with TLC for aflatoxins and with bioassays for paralytic shellfish toxins are made. Novel combinations such as headspace-HPLC analyses for SO2 and HPLC-AA for organometallic compounds are discussed.  相似文献   

18.
高效液相色谱法测定氨基酸的研究进展   总被引:1,自引:0,他引:1  
氨基酸是构成生物体的基础物质,氨基酸分析是生命科学研究中最重要的领域之一。高效液相色谱法因分析速度快、操作简便、检测灵敏、适用范围广等优点而广泛应用于食品工业、制药工业、生命科学研究等领域。该文综述了高效液相色谱分析氨基酸的方法,包括柱后衍生法、柱前衍生法、高效阴离子交换色谱-积分脉冲安培检测法和高效液相色谱-蒸发光散射检测法。并对上述方法进行了比较,为日常的氨基酸分析提供了参考。  相似文献   

19.
Retinol palmitate (vitamin A, 73.3 microg/g) in an emulsified nutritional supplement was determined by solid-phase extraction (SPE) and high-performance liquid chromatography (HPLC) with fluorescence detection (excitation 350 nm, emission 480 nm) using monosodium L-glutamate as a dissolving agent to obtain higher recovery of vitamin A from the emulsified sample solution. A Bond Elut C2 cartridge (500 mg) was chosen for SPE after comparison with 16 other types. A sample solution was applied to a conditioned Bond Elut C2 cartridge and then vitamin A was eluted with ethanol followed by HPLC. The proposed method was simple, rapid (sample preparation time by SPE: ca. 8 min, retention time: ca. 8 min), sensitive [detection limit: ca. 0.1 pg/injection (100 microl) at a signal-to-noise ratio of 3:1], highly selective and reproducible (relative standard deviation (RSD): ca. 2.9% (n = 5), between-day RSD ca. 3.7 (5 days). The recovery of vitamin A was over 90% by the standard addition method.  相似文献   

20.
For the determination of vitamin B6 vitamers (pyridoxal phosphate, pyridoxamine phosphate, pyridoxal, pyridoxine, pyridoxamine) and 4-pyridoxic acid in biological samples such as plasma, cerebrospinal fluid and rat brain regions, a sensitive micromethod using high-performance liquid chromatography (HPLC) with fluorescence detection in combination with post-column derivatization is described. Metaphosphoric acid tissue extracts with deoxypyridoxine as an internal standard were injected into the HPLC system with a binary gradient elution at a flow-rate of 1.2 ml/min. The excitation wavelength of the fluorescence detector was set at 328 nm and the emission wavelength at 393 nm with a 15-nm slit width for the photocell. This method allows the assay of vitamin B6 vitamers within 30 min in one chromatographic run. The present method has been applied extensively for the measurement of vitamin B6 vitamer levels in discrete brain regions of small animals, cells in culture and biopsy samples.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号