首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
S M Farid 《Pramana》1985,25(1):29-41
The etch pit diameters of soda glass detector samples exposed to 54 132 Xe-ions of different energies are measured for different etching times after etching the detector in a ‘new etchant’ free of the adverse effect of the etch product layer. The dependence of track diameter on the energy and on the energy loss, dE/dx of 54 132 Xe-ion in soda glass has been presented. The energy resolution of soda glass and the critical angle for etching of fission fragment tracks in glass detectors have also been determined. The maximum etched track length of 54 132 Xe-ion in soda glass has been compared with the theoretical range. The effects of different annealing conditions on bulk etch rate of glass detector and on diameters of 54 132 Xe-ion tracks have been presented. Experimental results show that there is a decrease in track etch rate, etching efficiency and etchable range of 54 132 Xe-ions with annealing. The annealing of oblique tracks shows that the vertical tracks are more stable than the oblique tracks.  相似文献   

2.
S M Farid 《Pramana》1985,25(3):259-265
The effect of heat treatment on the latent tracks in cellulose nitrate plastic track detectors has been studied. The bulk etch rate increases with annealing temperature while the track diameters of different ions in cellulose nitrate decrease with increase in annealing time and temperature. Experimental results show that for heavier ions higher temperatures are needed for their complete erasure. The track length and track etch rate are decreased by the application of heat. Experiments reveal that annealing reduces track density. The vertical tracks are more stable than the oblique tracks and require higher temperature for their complete erasure.  相似文献   

3.
S M Farid 《Pramana》1986,26(5):419-425
The track etch rates of 10 20 Ne-ion in cellulose nitrate (LR-115) have been measured for different temperatures and the activation energy is determined. The experimental results show that both the track etch rate and the normalized track etch rate depend on the energy loss as well as on etching temperature. The maximum etched track length of 10 20 Ne-ion agrees with the theoretically computed range. The experimental results show that there is no sharp threshold, at least in CN(LR-115).  相似文献   

4.
5.
S M Farid 《Pramana》1984,23(2):187-198
Measurements of the dependence of track etch rate on the energy-loss of different ions have been presented. In this method, 18 40 Ar, 10 22 Ne, 8 16 O and 6 12 C-ions of different energies are used as energetic heavy ions for track formation in the detectors. The bulk etch rate and track etch rate are measured for different temperatures and hence the activation energies are determined. The variation ofV =V t /V b along the trajectory of the track has been shown for different temperatures. The maximum etched track length is compared with the theoretical range as well as with the range reported earlier. The experimental results indicate the absence of a well-defined threshold in the plastics studied.  相似文献   

6.
S M Farid  A P Sharma 《Pramana》1983,21(5):339-345
Makrofol polycarbonate plastic track detectors have been exposed to 54 132 Xe -ions of energy 1.1 MeV/N from the cyclotron beam. The bulk etch rate and track etch rate are measured for different temperatures and the activation energies are calculated. The maximum etched track length is compared with the theoretically computed range. The critical energy loss is (dE/dx) c =5 MeV cm2 mg−1 for this detector material.  相似文献   

7.
Latent damage tracks of energetic40Ar ions (18·56 MeV/u) have been recorded in Lexan polycarbonate detector. Bulk and track-etch parameters are evaluated under successive chemical etching. Our results show a linear correlation between the measured track-etch rate along the track and the corresponding total energy-loss rate and predict a threshold value of 5·0 MeV mg−1 cm2 for track registration. Maximum etchable track lengths of40Ar ions as a function of energies have also been measured and compared with three different sets of theoretical ranges.  相似文献   

8.
Track etch rate characteristics of CR-39 plastic detector exposed to 28Si ions of 670 MeV energy have been investigated. Experimental results were obtained in terms of frequency distribution of the track diameter, track density and bulk etching rate. A dependence of the mean track diameter on energy was found. The application of the radiation effect of heavy ions on CR-39 in the field of radiation detection and dosimetry are discussed. Results indicated that it is possible to produce etchable tracks of 28Si in this energy range in CR-39. We also report the etching characteristics of these tracks in the CR-39 detector.  相似文献   

9.
To analyze the micro-track structure of heavy ions in a polymer material,parameters including bulk etch rate,track etch rate,etch rate ratio,and track core size were measured.The pieces of CR-39 were exposed to 100 MeV Si ions with normal incidence and were etched in 6.25N NaOH solution at 70 C.Bulk etch rate was read out by a profilemeter after several hours of etching.The other parameters were obtained by using an atomic force microscope(AFM)after a short time of etching.We have measured the second etch pits and minute etch pits to obtain the track growth curve and three dimension track structures to track the core size and etch rate measurements.The local dose of the track core was calculated by theδ-ray theory.In our study,we figure out that the bulk etch rate Vb=(1.58±0.022)μm/h,the track etch rate Vt=(2.90±0.529)μm/h,the etch rate ratio V=1.84±0.031,and the track core radii r≈4.65 nm.In the meantime,we find that the micro-track development violates the traditional track-growth model.For this reason,a scenario is carried out to provide an explanation.  相似文献   

10.
The polymer Lexan was irradiated to 80MeV O6+ ion beam using the 15UD pelletron at Inter University Accelerator Centre, New Delhi. The ion fluence ranging from 1011 to 3 × 1012 ions/cm2 has been used to study the dose effects of irradiation on Lexan. By using the etching technique, it is observed that the bulk etch rate of the sample increases with increasing the ion influence, while the activation energy associated with it show a decreasing trend which can be explained on the basis of polymer degradation.   相似文献   

11.
The effect of the properties of PADC nuclear track detectors after exposure to high doses of gamma absorbed doses up to 5×105 Gray (50 Mrad) were studied. The gamma source was a 9.03 PBq (244 KCi), Co-60 source. Results indicate that each of the bulk etch rate (Vb), the tracks etch rate (Vt) and the sensitivity (V) of the detectors increases with the high gamma absorbed dose, but there is a drop in these parameters at the low gamma absorbed dose. Signs of surface roughness were observed by increasing the gamma absorbed doses and changes in color observed for doses larger than 2×105 Gray. The temperature of detectors during irradiation time reached 41°C. The fission fragment tracks (from Cf-252 source) disappeared quickly within the etching time (minutes) for total absorbed doses greater than 3×105 Gray due to their high bulk etch rate.  相似文献   

12.
Abstract

Thermal annealing of latent tracks caused by the passage of heavy ions, viz. Pb208 (13.8 MeV/n) and Ni58 (15.37 MeV/n), in muscovite mica is investigated. The activation energy for track annealing, determined using different annealing models, is compared. The effect of thermal annealing on size and energy resolution of heavy ions in mica, based on the track etch rate and track length reduction, is discussed.  相似文献   

13.
A review is given about nuclear track formation in plastic track detectors. The radiation damage of heavy ions around the latent tracks is studied using measurements of radial track etch rates in Å-dimensions.  相似文献   

14.
R K Jain  S K Bose  K K Dwivedi 《Pramana》1991,37(5):431-436
Triafol-TN plastic detector foils have been irradiated with238U ions of energy 16.34 MeV/u and the tracks produced have been observed using the chemical etching technique. The bulk etch rate and track etch rate are determined under successive chemical etching. In our case, the validity of Arrhenius’s law is confirmed by the fact that the same value ofE a obtained for these different concentrations, within experimental errors. The results show a linear correlation between the measured track etch rate along the track and the corresponding total energy loss rate and a threshold value of ~ 5.0 MeV/(mg/cm2) for track registration was obtained. The maximum etched track length of238U-ion in triafol-TN has been compared with the theoretically computed range.  相似文献   

15.
In the present work a comparative study of track registration response of 40Ar ions in different types of Makrofol polycarbonates viz. Makrofol-KG, KL & N have been done. The etched track parameters viz. bulk etch rate, track etch rate, etch rate ratio, cone angle and etching efficiency were calculated. The variation of etching rates with temperature were found to be exponential and follow the Arrhenius equation. The values of activation energy for bulk and track etching were also calculated. Maximum etchable track length/range were also obtained and compared with the theoretical values obtained from computer program RANGE. From the results it is found that the polycarbonates having same chemical composition manufactured by different chemical processes have slightly different behavior.  相似文献   

16.
At the beginning of the etching process a constant track etch rate can be assumed. In deeper detector layers, however, the etch rate varies drastically along the particle trajectories. Consequently, the indirect determination of the track etch rate by measuring the etch pit diameters on the detector surface does not yield correct results. Therefore, a method for the direct measurement of the track etch rate as a function of the depth within the detector was developed. Applying this method, the relationship between the track etch rate and the energy loss in CR-39/PATRAS could be derived.  相似文献   

17.
The thermal annealing of amorphous tracks of nanometer-size diameter generated in lithium niobate (LiNbO3) by Bromine ions at 45 MeV, i.e., in the electronic stopping regime, has been investigated by RBS/C spectrometry in the temperature range from 250°C to 350°C. Relatively low fluences have been used (<1012 cm−2) to produce isolated tracks. However, the possible effect of track overlapping has been investigated by varying the fluence between 3×1011 cm−2 and 1012 cm−2. The annealing process follows a two-step kinetics. In a first stage (I) the track radius decreases linearly with the annealing time. It obeys an Arrhenius-type dependence on annealing temperature with activation energy around 1.5 eV. The second stage (II) operates after the track radius has decreased down to around 2.5 nm and shows a much lower radial velocity. The data for stage I appear consistent with a solid-phase epitaxial process that yields a constant recrystallization rate at the amorphous-crystalline boundary. HRTEM has been used to monitor the existence and the size of the annealed isolated tracks in the second stage. On the other hand, the thermal annealing of homogeneous (buried) amorphous layers has been investigated within the same temperature range, on samples irradiated with Fluorine at 20 MeV and fluences of ∼1014 cm−2. Optical techniques are very suitable for this case and have been used to monitor the recrystallization of the layers. The annealing process induces a displacement of the crystalline-amorphous boundary that is also linear with annealing time, and the recrystallization rates are consistent with those measured for tracks. The comparison of these data with those previously obtained for the heavily damaged (amorphous) layers produced by elastic nuclear collisions is summarily discussed.  相似文献   

18.
The effect of post exposure annealing on the track registeration characteristics of CR-39 (Pershore) Solid State Nuclear Track Detectors has been studied. The changes introduced in the bulk etch rates, track diameter, and the track density have been observed. The results indicate that the bulk etch rate of the detectors and the size of the tracks are considerably changed due to annealing. Variations in the track density are, however, not serious in the presently studied temperature range.  相似文献   

19.
Sample of cellulose nitrate (Russian) is exposed to 18 40 Ar ions. The bulk etch rate has been studied at different etching temperatures and the activation energy for bulk etch rate has been calculated. The etched track lengths are measured for different etching times. The energy loss rate and range of 18 40 Ar ions in CN(R) is also calculated. The critical threshold value for etchable track in CN(R) is determined by comparing the theoretical and experimental values of track length. The response curve of CN(R) is also presented.  相似文献   

20.
An experimental study of the mechanism for chemical etching of fission fragment tracks in the natural mineral fluorite is described. A systematic search showed that a 3:1 mixture by volume of sulphuric to hydrochloric acids was a most appropriate etchant. Experiments directed at determining the etching efficiency as a function of solvent temperature are also discussed. The preferential track etch ratioVt/Vg, the track length and the track density all depend upon the time and temperature of annealing.

It is variations of the fission track density in fluorite, with etching time and annealing temperature, which make possible an overall geophysical interpretation of annealing data for the mineral in terms of the paleoisotherm of its intrinsic fission track clock.

An interactive image analysis system INTIMAN, assembled for the swift and automatic readout of fission fragment track measurements, in both crystalline and non-crystalline materials, is described. Normal procedures for measuring and analyzing tracks are outlined.  相似文献   