首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 500 毫秒
1.
A kinetic-catalytic spectrophotometric flow-injection method was developed for the rapid and sensitive determination of trace amounts of copper(II). The method is based on the catalytic effect of copper(II) on the redox reaction of cysteine with iron(III). Iron(II) produced by the catalytic reaction reacts with 2,4,6-tris(2-pyridyl)-1,3,5-triazine (TPTZ) to form the iron(II)-TPTZ complex (lambda(max) = 593 nm). By measuring an absorbance of the complex, one could determine 0.05-8 ppb copper(II) with the relative standard deviations (n = 10) of 1.6%, 1.3%, and 0.8% for 0.5 ppb, 1 ppb, and 2 ppb copper(II), respectively. The limit of detection (S/N = 3) was 0.005 ppb. The sample throughput was 30 h(-1). The proposed method was successfully applied to the determination of copper in natural water and serum samples.  相似文献   

2.
Mudasir  Yoshioka N  Inoue H 《Talanta》1997,44(7):1195-1202
A reversed phase ion-paired chromatographic method that can be used to determine trace amounts of iron (II,III), nickel (II) and copper (II) was developed and applied to the determination of iron (II) and iron (III) levels in natural water. The separation of these metal ions as their 4,7-diphenyl-1,10-phenanthroline (bathophenanthroline) chelates on an Inertsil ODS column was investigated by using acetonitrile-water (80/20, v/v) containing 0.06 M perchloric acid as mobile phase and diode array spectrophotometric detection at 250-650 nm. Chromatographic parameters such as composition of mobile phase and concentration of perchloric acid in mobile phase were optimized. The calibration graphs of iron (II), nickel (II) and copper (II) ions were linear (r > 0.991) in the concentration range 0-0.5, 0-2.0 and 0-4.0 mug ml(-1), respectively. The detection limit of iron (II), nickel (II) and copper (II) were 2.67, 5.42 and 18.2 ng ml(-1) with relative standard deviation (n = 5) of 3.11, 5.81 and 7.16% at a concentration level of 10 ng ml(-1) for iron (II) and nickel (II) and 25 ng ml(-1) for copper (II), respectively. The proposed method was applied to the determination of iron(II) and iron(III) in tap water and sea water samples without any interference from other common metal ions.  相似文献   

3.
A catalytic method for the determination of copper, based on the catalysis of the hexacyano-ferrate(III)-cyanide redox reaction, is proposed. Experimental conditions to achieve the lowest detection limit are selected from the kinetics of both the catalysed and the uncatalysed reactions. The experimental measurements can be made at room temperature without close control. The rate-constant method is the most sensitive and precise, whereas the fixed-concentration and fixed-time methods appear to be the most rapid for routine analysis. A detection limit of 1.3 ng/ml and a coefficient of variation of about 3% for the determination of 63 ng/ml can be achieved. The catalytic effect of copper seems to be highly specific. Lead(II), bismuth (III), antimony (III), iron (II), iron(III), chromium(III), lanthanum(III), cerium(III), titanium(IV), zirconium(IV) and uranium(VI) interfere by precipitation. Species such as tin(II), cobalt(II), manganese(II), sulphite and thiosulphite cause serious interference because they react with hexacyanoferrate(III). Chromate interferes by its colour. Suitable methods to avoid the interferences from antimony(III), iron(III), chromium(III), titanium(IV), zirconium(IV), uranium(VI) and chromate are proposed.  相似文献   

4.
A novel fluorescence method determination for iron(II) with a high selectivity and sensitivity has been proposed, based on the enhancement of fluorescence signals resulting from specific redox reaction between synthesized spin fluorescence probe pyrene-tetramethylpiperidinyl (TEMPO) and iron(II). Under the experimental conditions, fluorescent probe displayed a rapid and linear response for iron(II) over the concentration range from 2.4 x 10(-7) to 3.6 x 10(-6) mol/L. The limit of detection was 4.0 x 10(-8) mol/L. The relative standard deviation of six replicate measurements was 1.90% for 3.0 x 10(-7) mol/L iron(II). Because of the specific redox reaction between developed spin fluorescence probe and iron(II), there are few interference by other ions, especially in the presence of relative high concentration iron(III). The method has been successfully applied for iron(II) determinations in two different kinds of real samples. Results determined by the proposed method agree favorably with those determined UV-vis spectrometry method with 1,10-phenanthroline.  相似文献   

5.
A flow injection-photometric method has been developed for the determination of iron(II+III). The method is based on the catalytic effect of iron(III) on the hydrogen peroxide oxidation of 3,3',5,5'-tetramethylbenzidine to form a blue compound (lambda(max)=650 nm). In this catalyzed reaction, 1,10-phenanthroline acted as an effective activator. Iron(II) is also determined, being oxidized by hydrogen peroxide. Calibration graphs for iron(II) and iron(III) obtained under the optimized conditions were identical with each other and linear in the range 0.2-200 ng ml(-1) with a detection limit of 0.05 ng ml(-1) iron. The reproducibility was satisfactory with a relative S.D. of 1.0% for ten determinations of 5 ng ml(-1) iron(III). The proposed method was successfully applied to the determination of iron in river and lake water samples and can be determined free iron species.  相似文献   

6.
Lin J  Hobo T 《Talanta》1995,42(11):1619-1623
A novel chemiluminescent system, fluorescein-NH(2)OHOH(-), was developed for the determination of copper(II) in serum. A weak light emission arises from hydroxylamine in the presence of the organic reagent fluorescein in basic aqueous solution. Under the conditions of 1.2 x 10(-3) mol l(-1) NH(2)OH and 5 x 10(-3) mol l(-3) fluorescein, the light intensity is linearly dependent upon the concentration of copper(II) within the range 1-20 ppb. The relative standard deviation of the determination of copper(II) is 4.2% (n = 13) and the detection limit is 0.5 ppb. The system is highly selective for copper except in the presence of iron(II,III) and cobalt(II). In conjunction with potassium fluoride as masking agent, the method was successfully applied to the determination of microamounts of copper(II) in serum. A mechanistic study of the chemiluminescence reaction is also discussed.  相似文献   

7.
A flow injection procedure for the sequential spectrophotometric determination of iron(II) and iron(III) in pharmaceutical products is described. The method is based on the catalytic effect of iron(II) on the oxidation of iodide by bromate at pH = 4.0. The reaction was monitored spectrophotometrically by measuring the absorbance of produced triiodide ion at 352 nm. The activating effect for the catalysis of iron(II) was extremely exhibited in the presence of oxalate ions, while oxalate acted as a masking agent for iron(III). The iron(III) in a sample solution could be determined by passing through a Cd-Hg reductor column introduced in the FIA system to reduce iron(III) to iron(II), which allows total iron determination. Under the optimum conditions, iron(II) and iron(III) could be determined over the range of 0.05 - 5.0 and 0.10 - 5.0 microg ml(-1), respectively with a sampling rate of 17 +/- 5 h(-1). The experimental limits of detection were 0.03 and 0.04 microg ml(-1) for iron(II) and iron(III), respectively. The proposed method was successfully applied to the speciation of iron in pharmaceutical products.  相似文献   

8.
Singh HB  Agnihotri NK  Singh VK 《Talanta》1999,48(3):623-631
A sensitive derivative spectrophotometric method using 1-nitroso-2-naphthol has been developed for determination of trace amounts of cobalt in the presence of a neutral surfactant. Photometric parameters, viz., lambda(max), molar absorption coefficient and analytical sensitivity of the complex formed in micellar media are 420 nm, 3.18x10(4) l mol(-1) cm(-1) and 2.05 ng ml(-1), respectively. Beer's law holds from 0.20 to 3.0 mug ml(-1) of the analyte concentration. The method has a high sensitivity with a detection limit of 1.68 ng ml(-1). A selective determination of cobalt in presence of copper(II) or iron(III) using derivative spectral profiles and without any masking or pre-separation is also reported. Samples of drugs and standard alloys analysed by the proposed method yielded results comparable to those obtained using recommended procedures.  相似文献   

9.
《Analytical letters》2012,45(7):1219-1230
Abstract

An indirect photometric method with a continuous-flow analysis is presented for the determination of trace amounts of vanadium(IV). It is based on the redox reaction of copper(II) with vanadium(1V) in the presence of neocuproine. In the presence of neocuproine, copper(I1) is reduced easily by vanadium(I V) to a copper(1)-neocuproine complex, which shows a n absorption maximum at 454 nm. By measuring t h e absorbance of the complex at this wavelength, vanadium(1V) in t h e range 2×10?6 - 8 × mol dm?5 mol dm?3 can be determined at a rate of 120 samples h?1. The fractional determination of vanadium(1V) and iron(I1) is also studied.  相似文献   

10.
The possibility of application was examined of a reaction between 2,2′-diquinoxalyl and tin(II) or titanium(III) to catalytic determination of copper and iron. The reaction parameters, the influence of the hydrogen peroxide concentration, the hydrochloric acid concentration, and the presence of strange ions on oxidation of the reduced form of 2,2′-diquinoxalyl were tested.The usefulness of the established method was proven for the determination of copper(II) and iron(III) ions in the spectrally pure salts, having the concentration range of those ions 10?4-10?5%. The sensitivity of the discussed method is of 0.04 μg/ml.  相似文献   

11.
A sensitive and simultaneous spectrophotometric flow injection method for the determination of vanadium(IV) and vanadium(V) is proposed. The method is based on the effect of ligands such as 2,4,6-tris(2-pyridyl)-1,3,5-triazine (TPTZ) and diphosphate on the conditional redox potential of iron(III)/iron(II) system. A four-channel flow system is assembled. In this flow system, diluted hydrochloric acid (1.0 x 10(-2) mol dm(-3)) as a carrier for standard/sample, acetate buffer (pH 5.5) as a carrier for diphosphate solution, an equimolar mixed solution of iron(III) and iron(II) and a TPTZ solution are delivered, so that the baseline absorbance can be established by forming a constant amount of iron(II)-TPTZ complex (lambda(max) = 593 nm). Vanadium(IV) and/or vanadium(V) (400 microL) and diphosphate (200 microL) solutions are simultaneously introduced into the flow system; in this system the diphosphate solution passes through a delay coil. The potential of the iron(III)/iron(II) system increases in the presence of TPTZ, and therefore vanadium(IV) is easily oxidized by iron(III) to vanadium(V) to produce an iron(II)-TPTZ complex (a positive peak for vanadium(IV) appears). On the other hand, the potential of the redox system decreases in the presence of diphosphate, so that vanadium(V) can be easily reduced by iron(II) to vanadium(IV). In this case, the amount of iron(II) decreases according to the amount of vanadium(V). As a result, the produced iron(II)-TPTZ complex decreases (a negative peak for vanadium(V) appears). In this manner, two peaks for vanadium(IV) and vanadium(V) can be alternately obtained. The limits of detection (S/N = 3) are 1.98 x 10(-7) and 2.97 x 10(-7) mol dm(-3) for vanadium(IV) and vanadium(V), respectively. The method is applied to the simultaneous determination of vanadium(IV) and vanadium(V) in commercial bottled mineral water samples.  相似文献   

12.
Toral MI  Richter P  Rodríguez C 《Talanta》1997,45(1):147-153
A highly sensitive and selective second derivative spectrophotometric method has been developed for the determination of copper and iron in mixtures. The method is based on the separation of the analytes by liquid-liquid extraction as picrate ion pairs. Iron-picrate, reacts in the organic phase of DCE with 5-phenyl-3-(4-phenyl-2-pyridinyl)-1,2,4-triazine (PPT). Similarly the copper-picrate reacts with 2,9-dimethyl-4,7-diphenyl-1,10-phenantroline (bathocuproine). The extracts were evaluated directly by derivative spectrophotometric measurement, using the zero-crossing approach for determination of copper and graphic method for iron. Iron and copper were thus determined in the ranges 8-120 ng ml(-1) and 8-125 ng ml(-1), respectively, in the presence of one another. The detection limits achieved (3sigma) were 2.9 ng ml(-1) of iron and 2.8 ng ml(-1) of copper. The relative standard deviations were in all instances less than 2.1%. The proposed method was applied to the determination of both analytes in river and tap water and the results were consistent with those provided by the AAS standard method.  相似文献   

13.
Thakur M  Deb MK 《Talanta》1999,49(3):561-569
A simple and sensitive field detection and spectrophotometric method for determination of copper described herewith is based on the formation of a red coloured species of copper(II) with 1-[pyridyl-(2)-azo]-naphthol-(2) (PAN), TX-100 and N,N'-diphenylbenzamidine (DPBA) at pH range 7.8-9.4. The red coloured Cu(II)-PAN-(TX-100)-DPBA complex in chloroform shows maximum absorbance at 520 nm with molar absorptivity value of 1.14x10(5) l mol(-1) cm(-1). The detection limit of the method is 2 ng ml(-1) organic phase. The system obeys Beer's law up to 0.6 mug Cu(II) ml(-1) in organic solution. Most of the common metal ions generally found associated with copper do not interfere. The repeatability of the method was checked by finding relative standard deviation (RSD) (n=10) value for solutions each containing 0.2 mug ml(-1) of Cu(II) and the RSD value of the method was found to be 1.5%. The validity of the method has been satisfactorily examined for the determination of copper in soil and airborne dust particulate samples.  相似文献   

14.
在乙酸-乙酸钠缓冲溶液(pH4.4)中,以Cu(Ⅱ)催化抗坏血酸还原三氯偶氮胂褪色为指示反应,建立了测定痕量Cu(Ⅱ)的新方法.测定了反应级数和表观活化能.在70℃水浴中加热6min,测定的灵敏度为3.1×10~(-12)g·ml~(-1),线性范围为0~70ng/25ml.用于测定几种中草药样品中的铜,结果满意,相对标准偏差小于3%.  相似文献   

15.
Costa AC  Ferreira SL  Andrade MG  Lobo IP 《Talanta》1993,40(8):1267-1271
The reaction of nickel (II) with Br-PADAP, in the presence of tergitol NPX surfactant, forms a complex with absorption peaks at 520 and 560 nm. The iron(II)-Br-PADAP system at the same conditions forms a chelate with absorption peaks at 560 and 748 nm. This allows the simultaneous spectrophotometric determination of nickel and iron by measuring the absorbance at 560 and 748 nm. The proposed method, at ph 4.0-5.7, shows a molar absorptivity of 1.22 x 10(5)l . mole(-1) . cm(-1) for nickel at 560 nm and 8.20 x 10(4)l . mole(-1) . cm(-1) at 560 nm and 3.35 x 10(4)l . mole(-1) . cm(-1) at 748 nm for iron(II). Beer's law is obeyed up to 0.40 mu/ml of nickel(II) and up to 0.65 mu/ml of iron(II). Thiosulphate as masking agent allows the simultaneous determination of iron and nickel in the presence of high concentrations of copper. The ethylene glycol 2-(2-amino-ethyl) tetracetic acid provides the elimination of many other interferences. The method has been applied successfully to the simultaneous determination of nickel and iron in reference samples.  相似文献   

16.
Yu ZY  Teshima N  Nakano S  Kawashima T 《Talanta》1996,43(9):1519-1525
A catalytic flow-injection photometric method was developed for the determination of levels of cobalt as low as 10(-10) mol 1(-1). The method is based on the catalytic action of cobalt(II) on the oxidative coupling of 3-methyl-2-benzothiazolinone hydrazone with N,N-dimethylaniline to form a colored dye (lambda(max) = 590 nm) in the presence of hydrogen peroxide. The extremely activating effect was obtained in the presence of 1,2-dihydroxybenzene-3,5-disulfonate (Tiron) and sodium hydrogencarbonate as activators. Furthermore, the sensitivity of the method was enhanced by adding sodium dodecylsulfate as a surfactant. Linear calibration graphs were obtained over the range 0.04-0.2 ng ml(-1) and 0.1-0.5 ng ml(-1) cobalt(II). respectively, at a sampling rate of 30 per hour. The detection limit (signal/noise = 3) was 5 pg ml(-1) and the relative standard deviations for 0.1 and 0.04 ng ml(-1) cobalt (n = 10) were 1.0 and 2.3%, respectively. The method was applied to the determination of cobalt in pepperbush.  相似文献   

17.
A catalytic photometric method was developed for the determination of sub-nanogram levels of cobalt. The method is based on the catalytic effect of cobalt(II) on the oxidative coupling of 3-methyl-2-benzothiazolinone hydrazone with N-ethyl-N-(2-hydroxy-3-sulfopropyl)-3,5-dimethoxyaniline (DAOS) to form a colored dye (λmax=525 nm) in the presence of hydrogen peroxide. In this reaction system, 1,2-dihydroxybenzene-3,5-disulfonate (Tiron) acted as an effective activator for the catalysis of cobalt(II). Variation of reaction time between 5 and 10 min allows the determination range to be extended from 0.01 to 1.0 ng ml−1. The reaction system can also be successfully adapted to flow-injection analysis (FIA). The dynamic range of the proposed flow-injection method was 0.01–1.0 ng ml−1 and detection limit (signal/noise, S/N=3) was 5 pg ml−1 at a sampling rate of 30 h−1. Manual and flow-injection methods were applied to the direct determination of cobalt in pepperbush as a standard material.  相似文献   

18.
Tabata M  Morita H 《Talanta》1997,44(2):151-157
A simple, fast and sensitive flow-injection method is proposed for the determination of nanomolar amounts of ascorbic acid in tea, urine and blood. The procedure is based on the accelerating effect of a nanomolar level of ascorbic acid on the reaction of cooper(II) with 5,10,15,20-tetrakis(1-methylpyridinium-4-yl)porphyrin, H(2)tmpyp(4+). Ascorbic acid reduces Cu(II) to Cu(I) which catalyzes the incorporation of Cu(II) into H(2)tmpyp(4+) to form Cu(II)(tmpyp)(4+). In this method two solutions, one containing ascorbic acid and H(2)tmpyp(4+) and the other containing copper(II) and acetate buffer (pH 5.0), were injected into two flowing streams of water through two sample injectors of 120 mu1 sample volume. The mixture was allowed to react in a 2 m reaction coil and the colored solution of Cu(II)(tmpyp)(4+) was monitored at 550 nm (epsilon = 2.01 x 10(4)M(-1)cm(-1)). The present method was applied to the determination of ascorbic acid in tea, urea and blood. Reducing agents such as sugars and vitamins B(1), B(2), B(6) and B(12) did not give serious errors at a concentration of 10(-6) M for the determination of 1.0 x 10(-8)M ascrobic acid. The relative standard deviation of the present method was 2.8% for the determination of 1.0 x 10(-8)M ascorbic acid. The reaction mechanism was clarified from the kinetic results of the formation of Cu(II)(tmpyp)(4+) in the presence of various concentrations of ascorbic acid, copper(II) and hydrogen ion.  相似文献   

19.
A flow injection-catalytic spectrophotometric method using a serial flow cell was proposed for the successive determination of trace amounts of copper and iron. This method is based on the oxidation coupling of p-anisidine with N,N-dimethylaniline in the presence of hydrogen peroxide to form a dye, which has an absorption maximum at 740 nm. In this indicator reaction, ligands such as 1,10-phenanthroline (phen) and diphosphate were achieved to improve the sensitivity and selectivity. Under the optimal experimental conditions, the determinable ranges were 0.05-5 ppb for copper and 0.5 - 100 ppb for iron, respectively. The RSDs (n = 10) were 0.78% for 0.5 ppb copper(II) and 0.5% for 200 ppb iron(III). The sample throughput was 30 h(-1). The present flow-injection method was applied to the determination of copper and iron in standard river water, tap water, and other natural water samples, and also to the analysis of labile and inert complexes in synthesized samples containing humic acid with copper(II) or iron(III).  相似文献   

20.
A flow injection method for the sequential determination of iron(II) and iron(III) was developed. It is based on the differential reaction kinetics of iron(II) and iron(III) with Tiron in a double-injection FI system. The proposed method employs the accelerating action of copper(II) for the oxidation of iron(II) in the presence of Tiron. A linear calibration graph is obtained for iron (II) and iron(III) in the concentration range 1.8 × 10–5– 1.8 × 10–4 mol/L; the throughput of samples is 30 injections/h.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏