首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Hao Z  Chen H  Zhu X  Li J  Liu C 《Journal of chromatography. A》2008,1209(1-2):246-252
Amorphous poly(ethylene terephthalate) (PET), which possess a low softening temperature (T(s)=75 degrees C), was exploited to fabricate the electrophoresis chip with an integrated gold electrode for amperometric detection, with emphases being focused on the PET surface modification via UV light and air plasma. Both UV irradiation and plasma treatment were found to be able to improve the surface wettability, enhance the supported electroosmotic flow (EOF), and increase thermal bonding strength of PET sheets, with the latter being more efficient and less time-consuming than the former in the surface modification. Upon treated with plasma for 2 min, the PET sheets could be thermally bonded at 65 degrees C. T-peer test showed that the bonding strength increased from 10 g/cm for native PET sheets to 1250 g/cm for the plasma treated sheets when chips were bonded at the softening point, Attenuated-total-internal-reflection spectrum showed that, after being exposed to the UV light, carboxylic groups site-selectively formed in the UV-exposed region on PET surface. These UV-induced carboxylic groups were further utilized as the scaffold for preparation of micro-gold electrode via electroless gold plating. By using this established UV-directed electroless plating and the plasma-assisted thermal bonding techniques, the full PET electrophoresis chip with an integrated micro-gold electrode could be fabricated in common chemistry laboratory without the need of clean rooms. The fabricated PET chips were demonstrated for separation and detection of model analytes of dopamine (DA) and catechol (CA). Satisfactory resolution of the two analytes was achieved within 40s, and detection limits of 0.87 microM and 1.28 microM for DA and CA were obtained, respectively.  相似文献   

2.
Kong Y  Chen H  Wang Y  Soper SA 《Electrophoresis》2006,27(14):2940-2950
A novel method of photoresist-free micropatterning coupled with electroless gold plating is described for the fabrication of an integrated gold electrode for electrochemical detection (ED) on a polycarbonate (PC) electrophoresis microchip. The microelectrode layout was photochemically patterned onto the surface of a PC plate by selective exposure of the surface coated without photoresist to 254 nm UV light through a chromium/quartz photomask. Thus, the PC plate was selectively sensitized by formation of reactive chemical moieties in the exposed areas. After a series of wet chemistry reactions, the UV-exposed area was activated with a layer of gold nanoparticles that served as a seed to catalyze the electroless plating. The gold microelectrode was then selectively plated onto the activated area by using an electroless gold plating bath. Nonselective gold deposition on the unwanted areas was eliminated by sonication of the activated PC plate in a KSCN solution before electroless plating, and the adhesion of the plated electrodes to the PC surface was strengthened with thermal annealing. Compared with the previously reported electroless plating technique for fabrication of microelectrodes on a microchip, the present method avoided the use of a membrane stencil with an electrode pattern to restrict the area to be wet-chemically sensitized. The CE with integrated ED (CE-ED) microchip was assembled by thermal bonding an electrode-plated PC cover plate to a microchannel-embossed PC substrate. The novel method allows one to fabricate low-cost, electrode-integrated, complete PC CE-ED chips with no need of a clean room. The fabricated CE-ED microchip was demonstrated for separation and detection of model analytes, including dopamine (DA) and catechol (CA). Detection limits of 0.65 and 1.03 microM were achieved for DA and CA, respectively, and theoretical plate number of 1.4 x 10(4) was obtained for DA. The plated gold electrode can be used for about 4 h, bearing usually more than 100 runs before complete failure.  相似文献   

3.
This paper presents a capillary electrophoresis poly(methyl methacrylate) (PMMA) based microchip for electrochemical detection applications featuring embedded gold nanoelectrode ensemble (GNEE) working and decoupler electrodes. In fabricating the microchip, the GNEE films are pressed directly onto the metallic electrode structures using a hot embossing technique, and the microfluidic channels are then sealed using a low-temperature azeotropic solvent bonding method. The detection performance of the microchip is evaluated using dopamine and catechol analytes for illustration purposes. The experimental results show that the GNEE working electrode provides a significantly higher signal response than that obtained from a bulk gold electrode when applied to the detection of dopamine analyte. Compared to a conventional bulk palladium decoupler electrode, the GNEE decoupler electrode reduces both the amplitude of the charge current (3.5 nA vs. 18.7 nA) and the baseline drift at higher separation voltages. The measured baseline current drift for the microchip equipped the proposed GNEE decoupler electrode is around three times smaller than the microchip with the palladium decoupler electrode under the applied separation electric field from 40 V/cm to 240 V/cm. Finally, when detecting a mixture of 1mM dopamine and 1mM catechol, the calculated signal response of the microchip with a GNEE decoupler electrode is approximately five times higher than that obtained from a microchip with a bulk Pd decoupler electrode, resulting in the detection limit of 1 microM for the proposed GNEE-based microchip device. Overall, the results indicate that the proposed capillary electrophoresis-electrochemical detection (CE-ED) microchip with embedded GNEE working and decoupler electrodes provides an ideal solution for sample detection in lab-on-a-chip and micro total analysis applications.  相似文献   

4.
Our efforts have been focused on developing a self-contained and transportable microfabricated electrophoresis (CE) system with integrated electrochemical detection (ED). The current prototype includes all necessary electrodes “on-chip” and utilizes miniaturized CE and ED supporting electronics custom designed for this purpose. State-of-the-art design/modeling tools and novel microfabrication procedures were used to create recessed platinum electrodes with complex geometries and the CE/ED device from two patterned ultra-flat glass substrates. The electrodes in the bottom substrate were formed by a self-aligned etch and deposition technique followed by a photolithographic lift-off process. The microchannels (20 μm deep×65 μm wide (average)) were chemically etched into the top substrate followed by thermal bonding to complete the microchip device. CE/ED experiments were performed using 0.02 M phosphate buffer (pH 6), an analyte/buffer solution (2.2 mM dopamine, 2.3 mM catechol) and varying separation voltages (0-500 V) with a custom electronics unit interfaced to a laptop computer for data acquisition. Detection limits (S/N=3) were found to be at the micromolar level and a linear detection response was observed up to millimolar concentrations for dopamine and catechol. The microchip CE/ED system injected 50 pl volumes of sample, which corresponded to mass detection limits on the order of 200 amol. For the first time, an integrated “on-chip” multi-electrode array CE/ED device was successfully designed, fabricated and tested. The majority of the electrodes (six out of eight) in the array were capable of detecting dopamine with the amplitude of the signal (i.e., peak heights) decreasing as the electrode distance from the channel exit increased.  相似文献   

5.
A new SU-8 based microchip capillary electrophoresis (MCE) device has been developed for the first time with integrated electrochemical detection. Embedded electrophoretic microchannels have been fabricated with a multilayer technology based on bonding and releasing steps of stacked SU-8 films. This technology has allowed the monolithic integration in the device of the electrochemical detection system based on platinum electrodes. The fabrication of the chips presented in this work is totally compatible with reel-to-reel techniques, which guarantee a low cost and high reliability production. The influence of relevant experimental variables, such as the separation voltage and detection potential, has been studied on the SU-8 microchip with an attractive analytical performance. Thus, the effective electrical isolation of the end-channel amperometric detector has been also demonstrated. The good performance of the SU-8 device has been proven for separation and detection of the neurotransmitters, dopamine (DA) and epinephrine (EP). High efficiency (30,000-80,000 N/m), excellent precision, good detection limit (450 nM) and resolution (0.90-1.30) has been achieved on the SU-8 microchip. These SU-8 devices have shown a better performance than commercial Topas (thermoplastic olefin polymer of amorphous structure) microchips. The low cost and versatile SU-8 microchip with integrated platinum film electrochemical detector holds great promise for high-volume production of disposable microfluidic analytical devices.  相似文献   

6.
A simple method to fabricate cylindrical carbon electrodes for use in capillary electrophoresis (CE) microchips is described. The electrodes were fabricated using a metallic wire coated with carbon ink. Several experimental variables were studied in order to establish the best conditions to fabricate the electrode. Finally, the electrodes were integrated in a poly(dimethylsiloxane) microchip and used for the analysis of phenolic compounds. Using the optimum conditions, the analysis of a mixture of dopamine, epinephrine, catechol, and 4-aminophenol was achieved in less than 240 s, showing good linear responses (R2 = 0.999) in the 0.1-190 μM range, and limits of detection (without the use of stacking or a decoupler) of 140 and 105 nM for dopamine and epinephrine, respectively.  相似文献   

7.
Chen G  Zhang L  Wang J 《Talanta》2004,64(4):1018-1023
Multi-walled carbon nanotube (CNT) was mixed with epoxy to fabricate microdisc electrode used as a detector for a specially designed miniaturized capillary electrophoresis (CE)-amperometric detection system for the separation and detection of several bioactive thiols. The end-channel CNT amperometric detector offers favourable signal-to-noise characteristics at a relatively low potential (0.8 V) for detecting thiol compounds. Factors influencing the separation and detection processes were examined and optimized. Four thiols (homocysteine, cysteine, glutathione, and N-acetylcysteine) have been separated within 130 s at a separation voltage of 2000 V using a 20 mM phosphate running buffer (pH 7.8). Highly linear response is obtained for homocysteine, cysteine, glutathione, and N-acetylcysteine over the range of 5-50 μM with detection limits of 0.75, 0.8, 2.9, and 3.3 μM, respectively. Good stability and reproducibility (R.S.D. < 5%) are obtained reflecting the minimal adsorption of thiols at the CNT electrode surface. The new microchip protocol should find a wide range of bioanalytical applications involving assays of thiol compounds.  相似文献   

8.
A simple, rapid and portable electrochemical microchip sensing platform has been successfully constructed for chromium(VI) determination. Gold–silver–platinum (Au–Ag–Pt) three-material electrodes (gold as working electrode, silver as reference electrode and platinum as counter electrode) were integrated on one poly(methyl methacrylate) (PMMA) substrate by polymer compatible photolithography process. The three-electrode microchip sensing platform was used for Cr(VI) determination for the first time, and exhibited high sensitivity and good reproducibility. A wide linear range from 2 to 200 μM with a good linear correlation (R2 = 0.998) was obtained, and the detection limit was 0.9 μM. In addition, the practical analytical application of the sensing micro-platform was assessed by determination of Cr(VI) in real water samples with satisfactory results. Armed with the remarkable advantages, such as ease of use, low analyte consumption, inexpensive cost and fast response time, the microchip sensing platform may hold great potential for the high-throughput and in-field environmental monitoring Cr(VI) pollutant.  相似文献   

9.
Integrated solid-phase extraction-zone electrophoresis (SPE-ZE) device has been designed and fabricated on microchip. The structures were fabricated by using multiple layers of SU-8 polymer with a novel technique that enables easy alignment and high yield of the chips. SU-8 adhesive bonding has two major advantages: it enables bonding of high aspect ratio pillars and it results in fully SU-8 microchannels with uniform electrokinetic flow properties. The SPE-ZE device has a fluidic reservoir with 15:1 high aspect ratio pillars for bead filters that act as a SPE part in the chip structure. The separation unit is a 25 mm long electrophoresis channel starting from the outlet of SPE reservoir. Argon laser-induced fluorescence (LIF) detector was used to monitor simultaneously the SPE reservoir and the detection site at the end of the electrophoresis channel. Flow characteristics and electric field distributions were simulated with Femlab software. Fluorescein was used as the analyte for detecting the operational performance of the chip. Adsorption, bead rinsing, elution and detection were tested to verify functioning of the chip design.  相似文献   

10.
Liu AL  He FY  Hu YL  Xia XH 《Talanta》2006,68(4):1303-1308
Rapid separation and determination of acetaminophen and its hydrolysate with end-channel electrochemical (EC) detection integrated on a plastified poly(ethylene terephthalate) (PET)-toner microchip capillary electrophoresis (CE) system was investigated. In this separation and detection system, a Pt ultramicroelectrode integrated on a three-dimensional adjustor was used as working electrode. Factors influencing the separation and detection were investigated and optimized. Results show that acetaminophen and p-aminophenol can be well separated within 84 s with R.S.D. < 1% for migration time and R.S.D. < 3.6% for detection current for both analytes. Detection limits for both analytes are determined to be 5.0 μM (S/N = 3). This method has been successfully applied to the detection of trace p-aminophenol in paracetamol tablets. The results demonstrate that the PET-toner microchips can obtain better performance than PDMS microfluidic devices but at much lower cost.  相似文献   

11.
Mecker LC  Filla LA  Martin RS 《Electroanalysis》2010,22(19):2141-2146
In this communication, we demonstrate that a carbon ink microelectrode array, where the electrodes are held at the same potential, affords significant signal enhancement in microchip electrophoresis with amperometric detection. The ability to fabricate an array of carbon ink microelectrodes with a palladium decoupler was demonstrated and the resulting electrodes were integrated with a valving microchip design. The use of an 8 electrode array led to a significant improvement in the limits of detection at the expense of separation resolution due to the increased detection zone size. It is also shown that microdialysis sampling can be integrated with the microchip device and a multi-analyte separation achieved.  相似文献   

12.
Wu Y  Lin JM  Su R  Qu F  Cai Z 《Talanta》2004,64(2):338-344
An end-channel amperometric detector with a guide tube for working electrode was designed and integrated on a home-made glass microchip. The guide tube was directly patterned and fabricated at the end of the detection reservoir, which made the fixation and alignment of working electrode relatively easy. The fabrication was carried out in a two-step etching process. A 30 μm carbon fiber microdisk electrode and Pt cathode were also integrated onto the amperometric detector. The characteristics and primary performance of the home-made microchip capillary electrophoresis (MCCE) were investigated with neurotransmitters. The baseline separation of dopamine (DA), catechol (CA) and epinephrine (EP) was achieved within 80 s. Separation parameters such as injection time, buffer components, pH of the buffer were studied. Relative standard deviations of not more than 6.0% were obtained for both peak currents and migration times. Under the selected separation conditions, the response for DA was linear from 5 to 200 μM and from 20 to 800 μM for CA. The limits of detection of DA and CA were 0.51 and 2.9 μM, respectively (S/N=3).  相似文献   

13.
Ruecha N  Siangproh W  Chailapakul O 《Talanta》2011,84(5):1323-1328
In this work, the rapid detection of cholesterol using poly(dimethylsiloxane) microchip capillary electrophoresis, based on the coupling of enzymatic assays and electrochemical detection, was developed. Direct amperometric detection for poly(dimethylsiloxane) (PDMS) microchip capillary electrophoresis was successfully applied to quantify cholesterol levels. Factors influencing the performance of the method (such as the concentration and pH value of buffer electrolyte, concentration of cholesterol oxidase enzyme (ChOx), effect of solvent on the cholesterol solubility, and interferences) were carefully investigated and optimized. The migration time of hydrogen peroxide, product of the reaction, was less than 100 s when using 40 mM phosphate buffer at pH 7.0 as the running buffer, a concentration of 0.68 U/mL of the ChOx, a separation voltage of +1.6 kV, an injection time of 20 s, and a detection potential of +0.5 V. PDMS microchip capillary electrophoresis showed linearity between 38.7 μg/dL (1 μM) and 270.6 mg/dL (7 mM) for the cholesterol standard; the detection limit was determined as 38.7 ng/dL (1 nM). To demonstrate the potential of this assay, the proposed method was applied to quantify cholesterol in bovine serum. The percentages of recoveries were assessed over the range of 98.9-101.8%. The sample throughput was found to be 60 samples per hour. Therefore, PDMS microchip capillary electrophoresis, based on the coupling of enzymatic assays and electrochemical detection, is very rapid, accurate and sensitive method for the determination of cholesterol levels.  相似文献   

14.
A new SWCNT modified gold detector for microchip capillary electrophoresis–electrochemistry is described. SWCNT modified gold electrode displays greatly improved sensitivity and separation resolution compared to bare gold electrode, reflecting the electrocatalytic activity of SWCNT. The SWCNT/Au electrode exhibits low background noise levels. Parameters such as separation voltage and detection potential of the microchip electrophoresis–electrochemistry with SWCNT modified gold electrode were optimized.  相似文献   

15.
In this work, a repeatable assembling and disassembling electrochemical aptamer cytosensor was proposed for the sensitive detection of human liver hepatocellular carcinoma cells (HepG2) based on a dual recognition and signal amplification strategy. A high-affinity thiolated TLS11a aptamer, covalently attached to a gold electrode through Au–thiol interactions, was adopted to recognize and capture the target HepG2 cells. Meanwhile, the G-quadruplex/hemin/aptamer and horseradish peroxidase (HRP) modified gold nanoparticles (G-quadruplex/hemin/aptamer–AuNPs–HRP) nanoprobe was designed. It could be used for electrochemical cytosensing with specific recognition and enzymatic signal amplification of HRP and G-quadruplex/hemin HRP-mimicking DNAzyme. With the nanoprobes as recognizing probes, the HepG2 cancer cells were captured to fabricate an aptamer-cell-nanoprobes sandwich-like superstructure on a gold electrode surface. The proposed electrochemical cytosensor delivered a wide detection range from 1 × 102 to 1 × 107 cells mL−1 and high sensitivity with a low detection limit of 30 cells mL−1. Furthermore, after the electrochemical detection, the activation potential of −0.9 to −1.7 V was performed to break Au–thiol bond and regenerate a bare gold electrode surface, while maintaining the good characteristic of being used repeatedly. The changes of gold electrode behavior after assembling and desorption processes were investigated by electrochemical impedance spectroscopy and cyclic voltammetry techniques. These results indicate that the cytosensor has great potential in disease diagnostic of cancers and opens new insight into the reusable gold electrode with repeatable assembling and disassembling in the electrochemical sensing.  相似文献   

16.
We describe the integration of a cyclo-olefin polymer based microchip with a sheathless capillary tip for electrospray ionization-mass spectrometry (ESI-MS). The microchip was fabricated by hot embossing and thermal bonding. Its design includes a side channel for adjusting the composition of the electrospray solution so that analytes in 100% water can be analyzed. The fused silica capillaries, used for sample introduction, and the electrospray tips for MS coupling were directly inserted into the microchannel before thermal bonding of the device. A microfabricated on-chip gold microelectrode was used to apply the electrospray voltage. Annealing the device after thermal bonding increased the pressure resistance of the microchip. The cross section of the microchannel was imaged by scanning electron microscopy to estimate the effects of the annealing step. The relationship between the applied electrospray voltages and MS signal was measured at different flow rates by coupling the device to an ion trap mass spectrometer. The performance of the microchip was evaluated by MS analysis of imipramine in ammonium acetate buffer solution by direct infusion. An alkylacrylate based monolith polymer bed for on-chip sample pretreatment and separation was polymerized in the microchannel and tested for ESI-MS applications.  相似文献   

17.
This paper describes the use of epoxy-encapsulated electrodes to integrate microchip-based electrophoresis with electrochemical detection. Devices with various electrode combinations can easily be developed. This includes a palladium decoupler with a downstream working electrode material of either gold, mercury/gold, platinum, glassy carbon, or a carbon fiber bundle. Additional device components such as the platinum wires for the electrophoresis separation and the counter electrode for detection can also be integrated into the epoxy base. The effect of the decoupler configuration was studied in terms of the separation performance, detector noise, and the ability to analyze samples of a high ionic strength. The ability of both glassy carbon and carbon fiber bundle electrodes to analyze a complex mixture was demonstrated. It was also shown that a PDMS-based valving microchip can be used along with the epoxy-embedded electrodes to integrate microdialysis sampling with microchip electrophoresis and electrochemical detection, with the microdialysis tubing also being embedded in the epoxy substrate. This approach enables one to vary the detection electrode material as desired in a manner where the electrodes can be polished and modified as is done with electrochemical flow cells used in liquid chromatography.  相似文献   

18.
Amperometric detector designs for capillary electrophoresis microchips   总被引:1,自引:0,他引:1  
Electrochemical (EC) detection is a sensitive and miniaturisable detection mode for capillary electrophoresis (CE) microchips. Detection cell design is very important in order to ensure electrical isolation from the high separation voltage. Amperometric detectors with different designs have been developed for coupling EC detection to CE-microchips. Different working electrode alignment: in-channel or end-channel has been tested in conjunction with several materials: gold, platinum or carbon. The end-channel detector was based on a platinum or gold wire manually aligned at the exit of the separation channel. Thick- (screen-printed carbon electrode) and thin-film (sputtered gold film) electrodes have also been employed with this configuration, but with a different design that allowed the rapid replacement of the electrode. The in-channel detector was based on a gold film within the separation channel. A gold-based dual electrode detector, which combined for the first time in- and end-channel detection, has been also tested. These amperometric detectors have been evaluated in combination to poly(methylmethacrylate) (PMMA) and Topas (thermoplastic olefin polymer of amorphous structure) CE-microchips. Topas is a new and promising cyclic olefin copolymer with high chemical resistance. Relevant parameters of the polymer microchip separation such as precision, efficiency or resolution and amperometric detection were studied with the different detector designs using p-aminophenol and L-ascorbic acid as model analytes in Tris-based buffer pH 9.0.  相似文献   

19.
We proposed herein a novel approach for fabricating nanoband microelectrodes for electrochemical detection on an electrophoresis microchip. The metal films were first obtained via region-selective electroless deposition of gold or copper films on PDMS substrates by selective region plasma oxidation through shadow masking. Both metal films show uniform surfaces with the thickness at the level of 100 nm. By casting another PDMS layer on the metal films, the cross section of the sandwich structures can be used as nanoband microelectrodes, which can be renewed just by cutting. These nanoband microelectrodes are successfully used as electrochemical detectors in microchip electrophoresis for the detection of amino acids, proteins and neurotransmitter molecules. Moreover, integrating an Au-Cu double-metal detector with a double-channel electrophoresis system, we can easily distinguish electroactive amino acids from that of non-electroactive amino acids.  相似文献   

20.
As an important phthalate plasticizer, dibutyl phthalate (DBP) was employed to decrease the bonding temperature of poly(methyl methacrylate) (PMMA) microfluidic chips in this work based on the fact that it can lower the glass transition temperature of PMMA. The channel plates of the PMMA microchips were fabricated by the UV-initiated polymerization of prepolymerized methyl methacrylate between a silicon template and a PMMA plate. Prior to bonding, DBP solution in isopropanol was coated on PMMA covers. When isopropanol in the coating was allowed to evaporate in air, DBP was left on the PMMA covers. Subsequently, the DBP-coated covers were bonded to the PMMA channel plates at 90 °C for 10 min under pressure. The channels in the complete microchips had been examined by optical microscope and scanning electron microscope. The results indicated that high quality bonding was achieved below the glass transition temperature of PMMA (∼105 °C). The performance of the PMMA microfluidic chips sealed by plasticizer-assisted bonding has been demonstrated by separating and detecting ionic species by capillary electrophoresis in connection with contactless conductivity detection.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号