首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 23 毫秒
1.
A new chemically modified electrode is constructed based on carbon ceramic electrode incorporated with zeolite ZSM-5. Voltammetric behavior of piroxicam at the carbon ceramic zeolite modified electrode (CCZME) was investigated. The modified electrode exhibited catalytic activity toward the electrooxidation of piroxicam. Experimental parameters such as solution pH, scan rate, concentration of piroxicam and zeolite amount were studied. It has been shown that using the CCZME, piroxicam can be determined by differential pulse voltammetry (DPV) and hydrodynamic amperometry (HA). Under the optimized conditions the calibration plots are linear in the concentration ranges of 0.20–25.00 and 0.20–50.10 μM with limit of detections of 0.65 and 0.29 μM for DPV and HA, respectively. The modified electrode with DPV and HA methods was successfully applied for analysis of piroxicam in pharmaceutical formulations. The results were favorably compared to those obtained by the spiked method. The results of the analysis suggest that the proposed method has promise for the routine determination of piroxicam in the products examined.  相似文献   

2.
In this paper, a high‐sensitivity electrochemical sensor based on platinum (Pt) doped nickel oxide (NiO) nanoparticles and multi‐walled carbon nanotubes (MWCNTs) modified glassy carbon electrode (Pt?NiO/MWCNTs/GCE) has been developed to determine piroxicam (PIR) and amlodipine (AML) simultaneously. The electrochemical behavior of PIR and AML at the proposed sensor has been investigated by cyclic voltammetry (CV), differential pulse voltammetry (DPV) and chronoamperometry (CA) methods. Pt doped NiO nanoparticles were synthesized by the sol‐gel procedure and were investigated using X‐ray diffraction (XRD), energy dispersive X‐ray spectroscopy (EDX) and field emission scanning electron microscopy (FESEM) techniques. DPV responses of PIR and AML increased linearly with their concentration in wide linear dynamic ranges of 0.6–320.0 μM and 1.0–250.0 μM, respectively. The limits of detection were 0.061 μM for PIR and 0.092 μM for AML. The excellent analytical figure of merits of the proposed modified electrode leads to application of it promising electrochemical sensor to determine PIR and AML in human serum and urine with satisfactory results.  相似文献   

3.
《Electroanalysis》2017,29(2):423-432
In the present paper, a stable and selective non‐enzymatic sensor is reported for determination of glucose (Glc) by using a carbon paste electrode modified with multiwall carbon nanotubes and Ni(II)‐SHP complex as modifier in an alkaline solution. This modified electrode showed impressive activity for oxidation of glucose in NaOH solution. Herein, Ni(II)‐SHP acts as a suitable platform for oxidation of glucose to glucolactone on the surface of the modified electrode by decreasing the overpotential and increasing in the current of analyte. Under the optimum conditions, the rate constant and electron transfer coefficient between electrode and modifier, were calculated to be 1.04 s−1 and 0.64, respectively. The anodic peak currents indicated a linear dependency with the square root of scan rate and this behavior is the characteristic of a diffusion controlled process. So, the diffusion coefficient of glucose was found to be 3.12×10−6 cm2 s−1 due to the used number of transferred electron of 1. The obtained results revealed two linear ranges (5 to 190.0 μM (R2=0.997), 210.0 to 700.0 μM (R2=0.999)) and the detection limit of 1.3 μM for glucose was calculated by using differential pulse voltammetry (DPV) method. Also, the designed sensor was used for determination of glucose in the blood serum and urine samples. Some other advantages of Ni(II)‐SHP/CNT/CPE sensor are remarkable reproducibility, stability and selectivity which can be related to using nanomaterial of carbon nanotubes due to enhancement of electrode surface area.  相似文献   

4.
A new sol‐gel derived electrocatalytic carbon ceramic electrode was prepared by incorporating copper(II) phthalocyanine (CuPc) in a carbon ceramic network. This electrode was used as a sensitive electrochemical sensor for determination of the insecticide Imidacloprid (1‐(6‐chloro‐3‐pyridylmethyl)‐N‐nitro‐imidazolidin‐2‐ylideneamine) by differential pulse voltammetry (DPV). The resulting modified electrode exhibits a cathodic peak potential shifted positively and an increasing in cathodic peak current in comparison with unmodified electrode. The redox properties of this modified electrode at various pH values and CuPc percentage were investigated. The catalytic current obtained from differential pulse voltammetry is linearly dependent on Imidacloprid concentration over the two linear ranges of 0.67‐17 μM and 17‐93 μM with correlation coefficient of R2 = 0.9999 and R2 = 0.990, respectively. The detection limit for Imidacloprid was found to be 0.28 μM according to lower linear range. Possible interferences from several common pesticides were also evaluated. The inherent stability, high sensitivity, low detection limit and low cost for each preparation are advantages of this sensor. Determination of Imidacloprid in commercial formulation and residual Imidacloprid in tomato grown in greenhouse (protected cultivation) was also conducted. The results obtained from commercial formulation were completely consistent with those obtained through the standard high‐performance liquid chromatography (HPLC) method.  相似文献   

5.
The present work demonstrates that simultaneous determination of adrenalin (AD) and paracetamol (PAR) can be performed on single‐walled carbon nanotube/chitosan/ionic liquid modified glassy carbon electrode (SWCNT‐CHIT‐IL/GCE). The electro‐oxidations of AD and PAR were investigated with cyclic voltammetry (CV), differential pulse voltammetry (DPV) and also chronoamperometry (CA) methods. DPV experiments showed that the oxidation peak currents of AD and PAR are proportional to the corresponding concentrations over the 1–580 μmol/L and 0.5–400 μmol/L ranges, respectively. The RSD at a concentration level of 15 μmol/L AD and 15 μmol/L PAR were 1.69% and 1.82%, respectively. Finally the modified electrode was used for simultaneous determination of AD and PAR in real samples with satisfactory results.  相似文献   

6.
A new carbon nanotubes modified electrode (poly‐Nq‐MWCNTs/GCE) was fabricated by electropolymerization of 1,2‐naphththoquinone to the surface of multi‐walled carbon nanotubes modified electrode by casting method. The morphology of the nanocomposite was characterized by scanning electron microscopy. Cyclic voltammetry and chronoamperometry were applied to investigate the electrochemical properties of the poly‐Nq‐MWCNTs nanocomposite modified electrode. The result of electrochemical experiments showed that such modified electrode had a favorable catalytic ability to oxidation of β‐nicotinamide adenine dinucleotide (NADH). The resulted sensor was sensitiveness to NADH and achieved 95β of the steady‐state current within 5s. Furthermore, the anodic peak current was linear to the concentration of NADH for the range from 1.0 μM to 0.14 mM. The linear equation was: I(μA) = 0.3987 + 0.1035c (μmol/L), the correlation coefficient r = 0.9962, the detect limit is down to 1 × 10?7 M (S/N = 3) and the sensitivity is 0.1035 μA/mmol. The well catalytic activity of the sensor was ascribed to the synergistic effect role played by MWCNTs and poly‐Nq. Moreover, the based sensor possesses good stability and reproducibility.  相似文献   

7.
A new chemically modified electrode is constructed based on multiwalled carbon nanotube/chitosan modified glassy carbon electrode (MWCNTs‐CHT/GCE) for simultaneous determination of acetaminophen (ACT) and mefenamic acid (MEF) in aqueous buffered media. The measurements were carried out by application of differential pulse voltammetry (DPV), cyclic voltammetry (CV) and chronoamperometry (CA) methods. Application of DPV method showed that the linear relationship between oxidation peak current and concentration of ACT and MEF were 1 μM to 145 μM, and 4 μM to 200 μM, respectively. The analytical performance of this sensor has been evaluated for detection of ACT and MEF in human serum, human urine and a pharmaceutical preparation with satisfactory results.  相似文献   

8.
《Electroanalysis》2005,17(10):873-879
A highly sensitive and fast responding sensor for the determination of morphine is described. The multiwall carbon nanotubes immobilize on preheated glassy carbon electrode (5 min at 50 °C) by gently rubbing of electrode surface on a filter paper supporting the carbon nanotubes.The results indicated that carbon nanotubes(CNTs) modified glassy carbon electrode exhibited efficiently electrocatalytic oxidation for morphine with relatively high sensitivity, stability and long life. Under conditions of cyclic voltammetry, the potential for oxidation of morphine is lowered by approximately 100 mV and the current is enhanced significantly (10 times) in comparison to the bare glassy carbon electrode at wide pH range (2–9). The electrocatalytic behavior is further exploited as a sensitive detection scheme for morphine determination by hydrodynamic amperometry. Under the optimized conditions the calibration plots are linear in the concentration range 0.5–150 μM with the calculated detection limit (S/N=3) of 0.2 μM and sensitivity of 10 nA/μM and a relative standard deviation (RSD) of 2.5% (n=10). The amperometric response is extremely stable, with no loss in sensitivity over a continual 30 min operation. Such attractive ability of multiwall carbon nanotubes (MWCNTs) modified GC electrode, suggests great promise for a morphine amperometric sensor. Finally the ability of the modified electrode was evaluated for simultaneous determination of morphine and codeine.  相似文献   

9.
Single‐wall carbon nanotubes (SWCNTs) were used as an immobilization matrix to incorporate [Ir(ppy)2(phen‐dione)](PF6) complex onto a glassy carbon electrode for the study of electrocatalytic reduction of periodate ion. Detailed preliminary electrochemical data for the Ir(III)‐complex in acetonitrile solution and for the modified GCE/SWCNTs/[Ir(ppy)2(phen‐dione)](PF6)/CGE are presented. The modified electrode was applied to selective amperometric detection of periodate through its electrocatalytic reduction to iodide at 0.200 V and pH 2.0. The use of amperometry resulted in two calibration plots over the concentration ranges of 1‐20 μM and 20‐450 μM, with a detection limit of 0.6 μM and sensitivity of 198 nA μM?1.  相似文献   

10.
The electrooxidation of epinephrine (EPI) and piroxicam (PRX) has been investigated by application of nickel hydroxide nanoparticles/multiwalled carbon nanotubes composite electrode (MWCNTs‐NHNPs/GCE) using cyclic voltammetry (CV), differential pulse voltammetry (DPV) and chronoamperometry (CA) methods. The modified electrode showed suitable electrochemical responses for EPI and PRX determination. Under the optimum conditions the electrode provides a linear response versus EPI and PRX concentrations in the range of 1–220 µM and 0.7–75 µM, respectively using the DPV method. Linear responses versus EPI and PRX concentrations in the range of 1–1000 µM and 1–800 µM, respectively, were obtained using the CA method. The modified electrode was used for determination of EPI and PRX in human urine with satisfactory results.  相似文献   

11.
The electrocatalytic oxidation of rapamycin, one of the most studied immunosuppressant, cancer-preventing drug, is investigated for the first time on the surface of the modified carbon paste electrode prepared by incorporating multi-walled carbon nanotubes (MWCNTs) and conductive polymer pyrrole using differential pulse voltammetry (DPV). Rapamycin exhibited a well-defined oxidation peak at +1.1 V (versus Ag/AgCl) in Briton Robinson buffer solution with a pH 4.0. Effect of the most important experimental parameters was optimized and obtained signals are linear to the concentration of rapamycin in the range from 0.1 to 20 μM with 0.06 μM limit of detection. The repeatability is calculated as ±2 % and the reproducibility as ±5 %. The possible interfering compounds were tested showing negligible effect and the sensor was successfully applied for the determination of rapamycin in commercial pharmaceutical formulations with obtained recoveries in the range from 98 % to 102 %.  相似文献   

12.
The electrochemical properties of hydrazine studied at the surface of a carbon paste electrode spiked with p‐bromanil (tetrabromo‐p‐benzoquinone) using cyclic voltammetry (CV), double potential‐step chronoamperometry and differential pulse voltammetry (DPV) in aqueous media. The results show this quinone derivative modified carbon paste electrode, can catalyze the hydrazine oxidation in an aqueous buffered solution. It has been found that under the optimum conditions (pH 10.00), the oxidation of hydrazine at the surface of this carbon paste modified electrode occurs at a potential of about 550 mV less positive than that of a bar carbon paste electrode. The electrocatalytic oxidation peak current of hydrazine showed a linear dependent on the hydrazine concentrations and linear analytical curves were obtained in the ranges of 6.00×10?5 M–8.00×10?3 M and 7.00×10?6 M–8.00×10?4 M of hydrazine concentration with CV and differential pulse voltammetry (DPV) methods, respectively. The detection limits (3σ) were determined as 3.6×10?5 M and 5.2×10?6 M by CV and DPV methods. This method was also used for the determination of hydrazine in the real sample (waste water of the Mazandaran wood and paper factory) by standard addition method.  相似文献   

13.
Single‐walled carbon nanotubes(SWCNTs) were dispersed into DMSO, and a SWCNTs‐film coated glassy carbon electrode was achieved via evaporating the solvent. The results indicated that CNT modified glassy carbon electrode exhibited efficiently electrocatalytic reduction for ranitidine and metronidazole with relatively high sensitivity, stability and life time. Under conditions of cyclic voltammetry, the potential for reduction of selected analytes is lowered by approximately 150 mV and current is enhanced significantly (7 times) in comparison to the bare glassy carbon electrode. The electrocatalytic behavior is further exploited as a sensitive detection scheme for these analytes determinations by hydrodynamic amperometry. Under optimized condition in amperometric method the concentration calibration range, detection limit and sensitivity were about, 0.1–200 μM, detection limit (S/N=3) 6.3×10?8 mol L?1 and sensitivity 40 nA/μM for metronidazole and 0.3–270 μM 7.73×10?8 mol L?1 and 25 nA/μM for ranitidine. In addition, the ability of the modified electrode for simultaneous determination of ranitidine and metronidazole was evaluated. The proposed method was successfully applied to ranitidine and metronidazole determination in tablets. The analytical performance of this sensor has been evaluated for detection of these analytes in serum as a real sample.  相似文献   

14.
Increasing attention has been paid to layered double hydroxide (LDH) film modified electrode attributing to its desirable properties for fabrication of electrochemical sensor. In this paper, the Zn‐Al LDH film modified glassy carbon electrode was characterized by electrochemical methods. The enhanced electrocatalytic currents and well‐separated potentials for epinephrine (EP) and uric acid (UA) were observed at the as‐prepared electrode. Under selected condition, the differential pulse voltammetry response of the modified electrode to EP (or UA) shows a linear concentration range of 0.5 μM to 0.3 mM (or 2 μM to 0.4 mM) in the presence of 10.0 μM UA (or 20.0 μM EP). At a signal‐to‐noise ratio of 3, the calculated limits of detection are 0.13 μM and 0.66 μM, respectively. The proposed method has been performed to successfully detect EP and UA in analysis of real samples, such as in EP injection solution and human urine samples.  相似文献   

15.
Carbon nanotube, graphene and carbon black, as electrode modifiers, were compared and evaluated for the electrochemical determination of vancomycin. Among them, the best results were obtained at the graphene‐modified electrode. Additions of vancomycin using square wave voltammetry at the graphene‐modified electrode showed a linear range from 0.70 μM to 50 μM and a detection limit of 0.20 μM was obtained. To control the correct dose of vancomycin and reduce its side effects, its accurate determination in blood plasma is very important. Therefore, the method was applied for the vancomycin determination in spiked human plasma samples and satisfactory recoveries were observed. The developed method exhibited fast analysis, high sensitivity, good repeatability and freedom from other interfering species.  相似文献   

16.
Electrochemical oxidation of vanillin (VAN) in the presence of caffeine (CAF) was studied on a gold (Au) electrode modified with 3‐amino‐1,2,4‐triazole‐5‐thiol (ATT) film by using differential pulse voltammetry (DPV) and cyclic voltammetry (CV) method. The formation of the ATT film on the Au electrode surface was characterized by the CV, fourier transform infrared spectroscopy (FTIR) and impedance spectroscopy (EIS) methods. A single irreversible oxidation peak of the VAN was obtained by using the CV method. The determination of VAN in the presence of CAF was carried out at pH 4 in Britton Robinson buffer (BR) by the DPV method. Under the optimal conditions, the oxidation peak current was proportional to the concentration of VAN in the range of 1.1 μM to 76.4 μM in the presence of CAF with the correlation coefficient of 0.997 and the detection limit of 0.19 μM (S/N=3). The selective determination of VAN in a commercial coffee sample was carried out with satisfactory results on the ATT‐Au modified electrode.  相似文献   

17.
In this study, glassy carbon electrode modified with nano gold‐crystal violet film has been used to detect arsenite (As (III)) in a model system and in groundwater samples. The modified electrode was characterized by scanning electrochemical microscopy (SECM) and electrochemical impedance spectroscopy (EIS). Using voltammetric measuring technique, linear response was obtained in a concentration range of 2.0–22.0 μM. The arsenite concentrations in groundwater samples varied between 2.4 μM to 4.8 μM. The sensitivity of the modified electrode for As (III) detection was 5.6 μA/μM cm2 and 0.8 μM concentration was found as lower limit of detection (LOD). The accuracy of the method was checked with standard method anodic stripping voltammetry (ASV). Groundwater samples were characterized with dynamic (DLS) and electrophoretic (ELS) light scattering measurements which have shown that particles present in different samples differ in size distribution and zeta potential which did not interfere with As (III) detection.  相似文献   

18.
A sensitive electroanalytical method for determination of gemifloxacin in pharmaceutical formulation has been investigated on the basis of the enhanced electrochemical response at multi-walled carbon nanotubes modified glassy carbon electrode in the presence of CTAB. Solubilized system of different surfactants including SDS, Tween-20 and CTAB were taken for the study of electrochemical behaviour of gemifloxacin at modified electrode. The reduction peak current increases in the presence of CTAB while other surfactants show opposite effect. The modified electrode exhibits catalytic activity, high sensitivity, stability and is applicable over wide range of concentration for the determination of gemifloxacin. The mechanism of electrochemical reduction of gemifloxacin has been proposed on the basis of CV, SWV, DPV and coulometeric techniques. The proposed squarewave voltammetric method shows linearity over the concentration range 2.47-15.5 μg/mL. The achieved limits of detection (LOD) and quantification (LOQ) are 0.90 ng/mL and 3.0 ng/mL respectively.  相似文献   

19.
A sodium dodecyl sulfate (SDS) functionalized multiwalled carbon nanotubes (MWNTs) electrode (SDS/MWNTs) was successfully constructed in this study. The electrochemical property of the SDS/MWNTs electrode has been characterized by electrochemical impedance spectroscopy (EIS), cyclic voltammetry (CV) and differential pulse voltammetry (DPV). Nyquist plots suggest that the immersion time of SDS affects the resistances of the MWNTs electrodes. The thickness of adsorbed SDS on MWNTs surface is estimated to be 1.23 nm, which is close to the value of SDS monolayer. CV results demonstrate a 5‐fold enhanced response for dopamine (DA) at the SDS/MWNTs electrode compared to the bare MWNTs one. DPV results illustrate that DA can be selectively determined in the presence of high concentration ascorbic acid (AA) with a linear range from 20 μM to 0.20 mM and a sensitivity of 0.024 μA μM?1 at the SDS/MWNTs electrode.  相似文献   

20.
An organic‐inorganic composite electrode was prepared by the sol‐gel method. For this purpose the carbon composite electrode (CCE) was modified with copper hexacyanoferrate (CuHCF). The CuHCF‐CCE was prepared by two methods. In one method CCE was prepared in one step and in another method the electrode was prepared in a two‐step process. The electrochemical behavior of the CuHCF modified electrode was studied by cyclic voltammetry; the modified electrode shows a pair of peaks with a surface‐confined characteristic in a 0.1 M phosphate buffer (pH 7) with K+ cation, as a supporting electrolyte. The CuHCF‐CCE showed electrocatalytic activity toward oxidation of Dopamine (DA). The kinetics of the catalytic reaction was investigated by using chronoamperometry. The average value of the rate constant for catalytic reaction and the diffusion coefficient were calculated. At a 0.85 V potential under hydrodynamic conditions (stirred solution), the oxidation current is proportional to the dopamine concentration, and the calibration plot was linear over the concentration range of 5‐85 μM.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号