首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 78 毫秒
1.
An effective electrochemical sensor was constructed using an unmodified boron-doped diamond electrode for determination of genistein by square-wave voltammetry. Cyclic voltammetric investigations of genistein with HClO4 solution indicated that irreversible behavior, adsorption-controlled and well-defined two oxidation peaks at about +0.92 (PA1) & +1.27 V (PA2). pH, as well as supporting electrolytes, are important in genistein oxidations. Quantification analyses of genistein were conducted using its two oxidation peaks. Using optimized experiments as well as instrumental conditions, the current response with genistein was proportionately linear in the concentrations range of 0.1 to 50.0 μg mL−1 (3.7×10−7−1.9×10−4 mol L−1), by the detection limit of 0.023 μg mL−1 (8.5×10−8 mol L−1) for PA1 and 0.028 μg mL−1 (1.1×10−7 mol L−1) for PA2 in 0.1 mol L−1 HClO4 solution (in the open circuit condition at 30 s accumulation time). Ultimately, the developed method was effectively applied to detect genistein in model human urine samples by using its second oxidation peak (PA2).  相似文献   

2.
The present work describes the individual, selective and simultaneous quantification of acetaminophen (ACP) and tramadol hydrochloride (TRA) using a modification‐free boron‐doped diamond (BDD) electrode. Cyclic voltammetric measurements revealed that the profile of the binary mixtures of ACP and TRA were manifested by two irreversible oxidation peaks at about +1.04 V (for ACP) and +1.61 V (for TRA) in Britton‐Robinson (BR) buffer pH 3.0. TRA oxidation peak was significantly improved in the presence of anionic surfactant, sodium dodecyl sulfate (SDS), while ACP signal did not change. By employing square‐wave stripping mode in BR buffer pH 3.0 containing 8×10?4 mol L?1 SDS after 30 s accumulation under open‐circuit voltage, the BDD electrode could be used for quantification of ACP and TRA simultaneously in the ranges 1.0–70 μg mL?1 (6.6×10?6–4.6×10?4 mol L?1) and 1.0–70 μg mL?1 (3.3×10?6–2.3×10?4 mol L?1), with detection limits of 0.11 μg mL?1 (7.3×10?7 mol L?1) and 0.13 μg mL?1 (4.3×10?7 mol L?1), respectively. The practical applicability of the proposed approach was tested for the individual and simultaneous quantification of ACP and/or TRA in the pharmaceutical dosage forms.  相似文献   

3.
《Electroanalysis》2017,29(4):1188-1196
In this work, one novel electrochemical sensor was prepared by alternative deposition of phosphomolybdic acid (PMoA) and poly(ethyleneimine) (PEI) on an indium tin oxide glass substrate through layer‐by‐layer assembly. The performance of as‐prepared electrode was evaluated with both of oxidizing compounds of iodate and H2O2 and reducing compounds of dopamine and ascorbic acid as models. The results showed that corresponding current response of redox peak increased linearly with the concentration of above compounds increasing in certain ranges, respectively. Limits of detection to them were in the range of 1.0×10−4 ‐ 4.3×10−4 mg mL−1 with cyclic voltammetry (CV) in 0.1 mol L−1 NaAc‐HAc buffer (pH 5.0). The electrode showed high stability and remained 95 % of its initial activity even after 100 cycles of CV scan. When applied in real samples of table salts, juice and human serum, high recoveries of 96.84 to 100.33 % were achieved with relative standard deviations of 1.11‐3.96 % (n=3) at three spiked levels. Moreover, it was also successfully applied for the simultaneous determination of dopamine and ascorbic acid in human serum with differential pulse voltammetry. The results indicated that PMoA/PEI multilayer modified electrode can be used as a universal electrochemical sensor for sensitive detection of redox compounds.  相似文献   

4.
A sequential online extraction, clean‐up and separation system for the determination of betaine, l ‐carnitine and choline in human urine using column‐switching ion chromatography with nonsuppressed conductivity detection was developed in this work. A self‐packed pretreatment column (50 × 4.6 mm, i.d.) was used for the extraction and clean‐up of betaine, l ‐carnitine and choline. The separation was achieved using self‐packed cationic exchange column (150 × 4.6 mm, i.d.), followed by nonsuppressed conductivity detection. Under optimized experimental conditions, the developed method presented good analytical performance, with excellent linearity in the range of 0.60–100 μg mL−1 for betaine, 0.75–100 μg mL−1 for l ‐carnitine and 0.50–100 μg mL−1 for choline, with all correlation coefficients (R2) >0.99 in urine. The limits of detection were 0.15 μg mL−1 for betaine, 0.20 μg mL−1 for l ‐carnitine and 0.09 μg mL−1 for choline. The intra‐ and inter‐day accuracy and precision for all quality controls were within ±10.32 and ±9.05%, respectively. Satisfactory recovery was observed between 92.8 and 102.0%. The validated method was successfully applied to the detection of urinary samples from 10 healthy people. The values detected in human urine using the proposed method showed good agreement with the measurement reported previously.  相似文献   

5.
《Electroanalysis》2017,29(10):2316-2322
A home‐made gold microelectrode (Au‐μE) was fabricated and its surface was modified with nanoporous gold structures via a facile electrochemical approach (anodization followed by electrochemical reduction method). The fabricated nanoporous Au microelectrode (NPG‐μE) was used as a sensor probe for the determination of As(III) in 1.0 mol L−1 HCl solution using square wave anodic stripping voltammetry (SWASV) technique. Field emission scanning electron microscopy (FE‐SEM) and cyclic voltammetry were used to characterize the surface morphology and assess the electrochemical surface area and the roughness factor of the NPG‐μE. SWASVs recorded with the NPG‐μE in As(III) solutions indicated linear behaviour in the concentration ranges of 10–200 μg L−1 and 2–30 μg L−1, with regression coefficients of 0.996 and 0.999 at a deposition time of 120 s, respectively. The limit of detection (LOD) was found to be 0.62 μg L−1 with high sensitivity of 29.75 μA (μg L−1)−1 cm−2. Repeatability and reproducibility were also examined and values were determined as 3.2 % and 9.0 %. Negligible interference from major interfering copper ion was noticed, revealing the excellent anti‐interference property of the proposed sensing platform. The developed NPG‐μE was successfully used for As(III) determination in tap water samples.  相似文献   

6.
《Electroanalysis》2018,30(9):1946-1955
In this paper, a rapid and sensitive modified electrode for the simultaneous determination of hydroquinone (HQ) and bisphenol A (BPA) is proposed. The simultaneous determination of these two compounds is extremely important since they can coexist in the same sample and are very harmful to plants, animals and the environment in general. A carbon paste electrode (CPE) was modified with silver nanoparticles (nAg) and polyvinylpyrrolidone (PVP). The PVP was used as a reducing and stabilizing agent of nAg from silver nitrate in aqueous media. The nAg‐PVP composite obtained was characterized by transmission electron microscopy and UV‐vis spectroscopy. The electrochemical behavior of HQ and BPA at the nAg‐PVP/CPE was investigated in 0.1 mol L−1 B−R buffer (pH 6.0) using cyclic voltammetry (CV) and square wave voltammetry (SWV). The results indicate that the electrochemical responses are improved significantly with the use of the modified electrode. The calibration curves obtained by SWV, under the optimized conditions, showed linear ranges of 0.09–2.00 μmol L−1 for HQ (limit of detection 0.088 μmol L−1) and 0.04–1.00 μmol L−1 for BPA (limit of detection 0.025 μmol L−1). The modified electrode was successfully applied in the analysis of water samples and the results were comparable to those obtained using UV‐vis spectroscopy.  相似文献   

7.
Simple and rapid voltammetric method for simultaneous determination of all-trans-retinyl acetate (RAc) or all-trans-retinyl palmitate (RPa) and α-tocopheryl acetate (α-TOAc) has been proposed. The respective method was based on the anodic oxidation of the compounds of interest by square-wave voltammetry in acetone with 0.1 mol L−1 LiClO4 at the glassy carbon electrode. The procedure was also beneficial with respect to simple dissolution of sample directly in the supporting electrolyte. The all-trans-retinyl acetate could be quantified in two linear ranges (3.1–140 μmol L−1 and 140–400 μmol L−1) and α-tocopheryl acetate in linear range 5.3–400 μmol L−1 with detection limits of 0.9 μmol L−1 RAc (or 0.8 μmol L−1 RPa) and of 1.6 μmol L−1 α-TOAc. Selected commercial cosmetic products were analysed achieving satisfactory recoveries.  相似文献   

8.
A cobalt oxide nanoparticles (Co3O4NPs) and multi walled carbon nanotubes (MWCNTs) modified carbon paste electrodes were used to study the electrochemical behavior of linagliptin and empagliflozin in Britton Robinson buffer solution of pH 8.0 using cyclic and square wave voltammetry. The above mentioned modified electrodes showed highly sensitive sensing and gave an excellent anodic response for both drugs. The peak current varied linearly over the concentration ranges: 3.98×10?5–1.53×10?3 mol L?1 (18.82–723.00 μg/mL) and 7.94×10?6–1.07×10?4 mol L?1 (3.65–48.25 μg/mL) with determination coefficients of 0.9999 and 0.9998 for linagliptin and empagliflozin, respectively. The recoveries and relative standard deviations were found in the following ranges: 98.80 %–102.00 % and 0.23 %–1.90 % for linagliptin and 98.30 %–101.80 % and 0.11 %–1.86 % for empagliflozin. The detection and quantification limits were 1.13×10?5 and 3.76×10?5 mol L?1 (5.34and17.77 μg/mL) for linagliptin, 1.71×10?6and 5.68×10?6 mol L?1 (0.77 and 2.56 μg/mL) for empagliflozin. The proposed sensors have been successfully applied for the determination of the drugs in bulk, pharmaceutical formulations and biological fluids.  相似文献   

9.
The voltammetric behavior of 3‐nitrofluoranthene and 3‐aminofluoranthene was investigated in mixed methanol‐water solutions by differential pulse voltammetry (DPV) at boron doped diamond thin‐film electrode (BDDE). Optimum conditions have been found for determination of 3‐nitrofluoranthene in the concentration range of 2×10?8–1×10?6 mol L?1, and for determination 3‐aminofluorathnene in the concentration range of 2×10?7–1×10?5 mol L?1, respectively. Limits of determination were 3×10?8 mol L?1 (3‐nitrofluoranthene) and 2×10?7 mol L?1 (3‐aminofluoranthene).  相似文献   

10.
The electrochemical reduction of carbamazepine in acetonitrile (ACN) and dimethylformamide (DMF) using a glassy carbon electrode and microelectrodes has been studied. The reduction process is consistent with an electrochemical‐chemical mechanism (EC) involving a two electron transfer followed by a first order reaction, as shown by the cyclic voltammetry (CV) and differential pulse voltammetry (DPV). Half‐wave potential, number of electron transferred, diffusion coefficient and rate constant of the associated chemical reaction are reported. Limits of detection (LOD) for DPV are 0.92 and 0.76 µg mL?1 (3.89×10?6 mol L?1 and 3.21×10?6 mol L?1) in ACN and DMF, respectively. Precision (%RSD) and recovery (%) values when pharmaceutical compounds (200mg carbamazepine tablets) and spiked plasma samples were tested ranged from 1.09 to 9.04 % and % recoveries ranged from 96 to 104.1 %.  相似文献   

11.
《Electroanalysis》2018,30(1):154-161
Trace amount of arsenate in the presence of arsenite was determined directly on pencil graphite electrode modified by graphene oxide and zirconium (Zr−G−PGE). The layer‐by‐layer modification of PGE was characterized by scanning electron microscopy (SEM), X‐ray photoelectron spectroscopy (XPS) and cyclic voltammetry (CV). Key point of the developed method was quick adsorption of arsenate than arsenite on the Zr−G−PGE. In optimal conditions, the Zr−G−PGE was applied for determination of arsenate using differential pulse voltammetry in a linear range 0.10–40.0 μg L−1 with a limit of determination of 0.12±0.01 μg L−1. The sensitivity of the electrode was 1.36±0.07 μA/μg L−1. The modified electrode was used to measure the concentration of arsenate in the river water. A recovery test was performed by introducing 10 μg L−1 arsenate into the rivers water in order and acceptable data of average recovery of 101.2 % was obtained. From the experimental results, the as‐prepared electrode can provide a satisfactory method for direct determination of arsenate in real samples.  相似文献   

12.
Glyceline, reline, or ethaline deep eutectic solvents and carbon black nanoparticles within a crosslinked chitosan film are investigated as glassy carbon electrode modifiers for the first time. The selected 5 mg mL−1 glyceline modified GCE was characterized by cyclic voltammetry, electrochemical impedance spectroscopy, and scanning electron microscopy. Simultaneous determination of acetaminophen and diclofenac by differential pulse adsorptive stripping voltammetry (DPAdSV) presented limits of detection of 2.6×10−8 and 5.2×10−8 mol L−1 for acetaminophen and diclofenac, respectively, in pharmaceutical and biological samples. The obtained results were compared with those obtained by HPLC at a confidence level of 95 %.  相似文献   

13.
《Electroanalysis》2005,17(24):2246-2253
Coated‐wire (CW) and tubular (Tu) type membrane sensors for creatinine are developed. These consist of creatinine tungstophosphate(CTP), creatinine molybdophosphate (CMP) and creatinine picrolonate (CPC) ion‐pair complexes as electroactive materials dispersed in plasticized poly(vinyl chloride) matrix membranes. Electrochemical evaluation of these sensors under static (batch) mode of operation reveals near‐Nernstian response with slopes of 62.9, 58.1, and 55.2 mV decade?1 over the concentration range 1×10?2–5.0×10?6, 1×10?2–7.5×10?5, and 1×10?2?3.1×10?5 mol L?1. The lower detection limits are 0.39, 3.49, and 2.20 μg mL?1 creatinine with CTP, CMP and CPC membrane based sensors plasticized with o‐NPOE, respectively. Tubular and coated wire CTP membrane sensors are incorporated in flow‐through cells and used as detectors for flow injection analysis (FIA) of creatinine. The intrinsic characteristics of the detectors under hydrodynamic mode of operation in a low dispersion manifold are determined and compared with data obtained under static mode of operation. With 10?2 mol L?1 phosphate buffer of pH 4.5 as a carrier solution, the tubular and coated wire CTP detectors exhibit rapid response of 58.9 and 50.7 mV decade?1 over the concentration range 1×10?2–1×10?5 mol L?1 and detection limits of 0.39 μg mL?1 and 0.85 μg mL?1, respectively. Validation of the assay methods with the proposed sensors by measuring the lower detection limit, range, accuracy, precision, repeatability and between‐day‐variability reveals good performance characteristics confirming applicability for continuous determination of creatinine. The sensors are used for determining creatinine in human blood serum at an input rate of 40 samples per hour. No interferences are caused by creatine, most common anions, cations and organic species normally present in biological fluids. The results favorably compare with data obtained using the standard spectrophotometric method.  相似文献   

14.
《Electroanalysis》2018,30(1):101-108
The present work describes the evaluation of microfluidic electroanalytical devices constructed by a 3D printer using ABS (acrylonitrile butadiene styrene) polymer combined with cotton threads as microchannels. Screen‐printed carbon electrodes (SPCEs) were used as electrochemical detector for amperometric determination of gallic and caffeic acid in wine samples. Using optimal experimental conditions (flow rate of 0.71 μL s−1, applied potential of +0.30 V and volume of injection of 2.0 μL) the proposed method presented a linear response for a concentration range of 5.0×10−6 to 1.0×10−3 mol L−1. The detection limits for gallic and caffeic acid were found to 1.5×10−6 mol L−1 and 8.0×10−7 mol L−1, respectively, with a sample throughput of 43 h−1. The achieved results are in agreement with those found using the official Folin‐Ciocaulteu method.  相似文献   

15.
A cathodically pretreated boron‐doped diamond electrode was used for the simultaneous anodic determination of ascorbic acid (AA) and caffeine (CAF) by differential pulse voltammetry. Linear calibration curves (r=0.999) were obtained from 1.9×10?5 to 2.1×10?4 mol L?1 for AA and from 9.7×10?6 to 1.1×10?4 mol L?1 for CAF, with detection limits of 19 μmol L?1 and 7.0 μmol L?1, respectively. This method was successfully applied for the determination of AA and CAF in pharmaceutical formulations, with results equal to those obtained using a HPLC reference method.  相似文献   

16.
《Electroanalysis》2017,29(3):835-842
A novel electrochemically activated doped Ta2O5 particles modified carbon paste electrode (EA‐Ta2O5‐CPE) was prepared and applied for selective and sensitive determination of chrysin. X‐ray diffraction (XRD), scanning electron microscopy (SEM), electrochemical impedance spectroscopy (EIS) techniques and cyclic voltammetry (CV) were used to characterize the Ta2O5 particles and investigate the electrochemical response of the sensor. Compared with bare CPE, the doped Ta2O5 modified electrode got much more porous by electrochemical treatment and exhibited larger effective surface area, more reactive site and excellent electrochemical catalytic activity toward the oxidation of chrysin. Under optimum conditions by LSV, the oxidation peak currents responded to chrysin linearly over a concentration range from 5.0×10−8 to 7.0×10−6 mol L−1 with a detection limit of 2.0×10−8 mol L−1 (5.08 ng mL−1). The fabricated sensor showed anti‐interference ability against the biological common interferents (i.e. baicalein, baicalin) and provided to be reliable for the determination of chrysin in Chinese medicinal herb Oroxylum indicum and chrysin capsules samples with satisfactory results.  相似文献   

17.
《Electroanalysis》2018,30(8):1837-1846
This study reports a highly sensitive electrochemical sensor based on Bi film modified glassy carbon electrode (BiF/GCE) for total determination and speciation trace concentrations of copper(II) ions in environmental water samples. Square wave‐adsorptive anodic stripping voltammetric (SW‐ASV) experiment was performed for monitoring selective accumulation of copper(II) with reagent 3‐[(2‐mercapto‐vinyl)‐hydrazono]‐1,3‐dihydro‐indol‐2‐one (MHDI) at pH 9–10. The mechanism of the electrode reaction of Cu2+‐MHDI complex was safely assigned. The sensor exhibited a wide linear range (3.22×10−9–2.0×10−7 mol L−1) with lower limits of detection (LOD) and quantitation (LOQ) of 9.6×1−10 and 3.22×10−9 mol L−1, respectively (R2=0.9993). The proposed sensor exhibited interference from active metal ions e. g. Cd, Hg. The performance of the proposed method was compared successfully with most of the reported methods and comparable efficiencies were obtained. The analytical utility of the proposed SW‐ASV method has been successfully validated for trace analysis of copper(II) in environmental water samples. The method offers a precise, accurate approach with good reproducibility, robustness, ruggedness, and cost effectiveness.  相似文献   

18.
《Electroanalysis》2017,29(2):506-513
A simple and highly sensitive sensor has been used for the determination of oxomemazine hydrochloride (OXO) in presence of paracetamol (PAR) and guaifenesin (GU). Carbon paste electrode was modified with multiwalled carbon nanotube (MWCNT), alizarine red S (AZ) and chitosan (CH). Scanning electron microscopy (SEM), electrochemical impedance spectroscopy (EIS), cyclic voltammetry (CV) and differential pulse voltammetry (DPV) were used to characterize the nanostructure and performance of the sensor. Under the optimized experimental conditions OXO gave linear response over the range of 2.00×10−6–1.00×10−4 mol L−1. The detection limit was found to be 4.35×10−7 mol L−1. The practical application of the modified electrode was demonstrated by measuring the concentration of OXO in pharmaceutical samples and urine. This revealed that suggested sensor shows excellent analytical performance for the determination of OXO in terms of a very low detection limit, high sensitivity and selectivity.  相似文献   

19.
《Electroanalysis》2017,29(3):907-916
A porous electrode material combining the features of vertically aligned multi‐walled carbon nanotubes (VAMWCNT) and diamond‐like carbon films (DLC) have been developed for a highly sensitive electrochemical sensor. For working electrode preparation, DLC has been grown onto VAMWCNT, forming a porous, conductive and stable composite. The electrochemical performance of this DLC:VAMWCNT electrode has been investigated toward detection and analysis of three well‐known molecules, namely paracetamol, codeine and caffeine. A ternary mixture of these analytes was simultaneously determined under optimum experimental conditions using square‐wave voltammetry. Wide linear concentration ranges and the limits of detection of 3.34×10−7 mol L−1, 1.57×10−7 mol L−1 and 3.67×10−7 mol L−1 were obtained for paracetamol, codeine and caffeine, respectively. We conclude that the proposed voltammetric method and the DLC:VAMWCNT electrode comprise a reliable methodology for simultaneous determination of paracetamol, codeine and caffeine in biological matrix samples.  相似文献   

20.
ABSTRACT

This work was focused in to develop an electroanalytical method based on a direct modification of a glassy carbon electrode (GCE) by the deposition of successive aliquots of diluted dispersions of functionalised carbon nanotubes (MWCNT-COOH) in ethanol (0.1 mg.mL?1) aiming the determination of Diuron into seawater samples, a common antifouling substance, using differential pulse voltammetry as electroanalytical technique. The GCE/MWCNT-COOH showed a sensitivity of 2.20 μA/μmol L?1 about 10 times higher than the unmodified counterpart (GCE) which showed a sensitivity of 0.192 μA/μmol L?1. The limits of detection and quantificationwere 6.88 × 10?8 and 2.29 × 10?7 mol L?1 for GCE/MWCNT-COOH while for GCE were 7.87 × 10?7 and 2.62 × 10?6 mol L?1, respectively. The applicability was evaluated with spiked detectable amounts of Diuron into seawater samples. The recovery results were between 76% and 119%.  相似文献   