首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 234 毫秒
1.
ABSTRACT: Xylazine is an α2‐adrenoceptor agonist and it is widely used in veterinary anesthesia in combination with ketamine. There is limited information on the metabolism of xylazine. A quantitative method for the determination of xylazine by HPLC‐ESI/MS/MS was developed. The method consisted of a protein precipitation extraction followed by analysis using liquid chromatography electrospray tandem mass spectrometry. The chromatographic separation was achieved using a Thermo Betasil Phenyl 100 × 2 mm column combined with an isocratic mobile phase composed of acetonitrile, methanol, water and formic acid (60:20:20:0.4) at a flow rate of 300 μL/min. The mass spectrometer was operating in selected reaction monitoring mode and the analytical range was set at 0.05–50 μm . The precision (%CV) and accuracy (%NOM) observed were 2.3–7.2 and 88.2–96.4%. In vitro metabolism studies were performed in rat liver microsomes and results showed moderate cytochrome P450 affinity (Km = 10.1 μm ) and a low metabolic stability of xylazine with a half‐life of 4.1 min in rat liver microsomes. Five phase 1 metabolites were observed. The main metabolite observed was an oxidation of the thiazine moiety at m/z 235 and, to a lesser extent, we observed the formation of N‐(2,6‐dimethylphenyl)thiourea at m/z 181 and three distinctive hydroxylated metabolites at m/z 237. Further experiments with ketamine and ketoconazole strongly supported that the metabolism of xylazine to its main metabolite is mediated by CYP3A in rat liver microsomes. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

2.
Pharmacokinetics of [6]-gingerol after intravenous administration in rats   总被引:1,自引:0,他引:1  
A high-performance liquid chromatographic method to determine [6]-gingerol, a pungent constituent of ginger, in rat plasma was developed and a pharmacokinetic study was performed in rats. Quantitative analysis with high reproducibility was achieved for [6]-gingerol over the concentration range of 0.2-40 micrograms/ml. After bolus intravenous administration at a dose of 3 mg/kg, the plasma concentration-time curve was described by a two-compartment open model. [6]-Gingerol was rapidly cleared from plasma with a terminal half-life of 7.23 min and a total body clearance of 16.8 ml/min/kg. Serum protein binding of [6]-gingerol was 92.4%.  相似文献   

3.
4.
Capsazepine is an antagonist of the transient receptor potential channel vanilloid 1 (TRPV1), which is known to play an important role in the regulation of pain and inflammation. A selective and sensitive quantitative method for the determination of capsazepine by HPLC‐ESI/MS/MS was developed. The method consisted of a protein precipitation extraction followed by analysis using liquid chromatography electrospray quadrupole ion trap mass spectrometry. The chromatographic separation was achieved using a 100 × 2 mm C18 Waters Symmetry column combined with a gradient mobile phase composed of acetonitrile and 0.1% formic acid aqueous solution at a flow rate of 220 µL/min. The mass spectrometer was operating in full‐scan MS/MS mode using two‐segment analysis. An analytical range of 10–5000 ng/mL was used in the calibration curve constructed in rat plasma. The inter‐batch precision and accuracy observed were 10.1, 6.4 and 6.1% and 100.8, 98.5 and 106.2% at 50, 500 and 5 000 ng/mL, respectively. An in vitro metabolic stability using rat, dog or mouse liver microsomes was performed to determine the intrinsic clearance of capsazepine. The results suggest a very rapid degradation with T1/2 ranging from 2.6 to 4.3 min and a high clearance, suggesting that drug bioavailability is considerably reduced following extravascular administrations, consequently affecting drug response. Three metabolites were identified by HPLC‐MS/MS. S‐hydroxylation (M + 16), oxidative desulfuration (M − 16) and desulfuration (M − 32) metabolites of capsazepine were observed following exposure to rat, dog and mouse microsomes. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

5.
Paper spray ionization (PSI) is a direct, fast, and low‐cost ambient ionization technique which may have clinical utility for qualitative and quantitative analysis of therapeutic drugs and metabolites from patient specimens. We developed and validated a PSI‐mass spectrometry (PSI‐MS/MS) method according to the US‐FDA guidelines for bioanalytical studies to measure the prostate cancer drug abiraterone directly from patient plasma. The established linearity range was 3.1–156.8 ng/mL with a precision (%CV) and an accuracy (%) range of 0.5–10.7 and 93.5–103.2, respectively. The mean internal standard normalized matrix factor for abiraterone was just below 1 with highest %CV of 10.2 at the low‐level quality control. In benchmarking the performance of this assay against a published LC‐MS/MS assay, we showed they were mostly equivalent, with the exception of accuracy with clinical samples. We found the quantitative values observed for abiraterone measured directly from patient plasma using PSI‐MS/MS showed positive bias. Upon investigation, we concluded the increased values were due to summed quantitation of isomeric abiraterone conjugates and metabolites which are separable by LC‐MS/MS, but not with the current PSI‐MS/MS configuration. Despite demonstrating the utility of PSI‐MS/MS for rapid bioanalysis, this study also highlighted a limitation encountered with the direct analysis of abiraterone in clinical samples.  相似文献   

6.
The pharmacokinetics of [6]-gingerol were investigated in rats with acute renal failure induced by bilateral nephrectomy, or those with acute hepatic failure induced by a single oral administration of carbon tetrachloride (CCl4), to clarify the contribution of the kidney and liver to the elimination process of [6]-gingerol. After bolus intravenous administration, a plasma concentration-time curve of [6]-gingerol was illustrated by a two-compartment open model. There was no significant difference in either the plasma concentration-time curve or any pharmacokinetic parameters between the control and nephrectomized rats. It is suggested, therefore, that renal excretion does not contribute at all to the disappearance of [6]-gingerol from plasma in rats. In contrast, hepatic intoxication with CCl4 elevated the plasma concentration of [6]-gingerol at the terminal phase. Its elimination half-life increased significantly, from 8.5 to 11.0 min, in CCl4-intoxicated rats. The extent of [6]-gingerol bound to serum protein was more than 90% and was affected very slightly by the CCl4-intoxication. These aspects indicate that [6]-gingerol is eliminated partly by the liver.  相似文献   

7.
A rapid, selective, and sensitive liquid chromatography coupled with tandem mass spectrometry (MS/MS) method was developed and validated for the quantitation of the novel CDK5 inhibitor ‘20–223' in mouse plasma. Separation of analytes was achieved by a reverse-phase ACE Excel C18 column (1.7 μm, 100 × 2.1 mm) with gradient elution using 0.1% formic acid (FA) in methanol and 0.1% FA as the mobile phase. Analytes were monitored by MS/MS with an electrospray ionization source in the positive multiple reaction monitoring mode. The MS/MS response was linear over the concentration range 0.2–500 ng/mL for 20–223. The within- and between-batch precision were within the acceptable limits as per Food and Drug Administration guidelines. The validated method was successfully applied to plasma protein binding and in vitro metabolism studies. Compound 20–223 was highly bound to mouse plasma proteins (>98% bound). Utilizing mouse S9 fractions, in vitro intrinsic clearance (CLint) was 24.68 ± 0.99 μL/min/mg protein. A total of 12 phase I and II metabolites were identified with hydroxylation found to be the major metabolic pathway. The validate method required a low sample volume, was linear from 0.2 to 500 ng/mL, and had acceptable accuracy and precision.  相似文献   

8.
A sensitive high‐performance liquid chromatography–positive ion electrospray tandem mass spectrometry (LC‐MS/MS) method was developed and validated for the quantification of methyllycaconitine (MLA) in rat plasma and brain tissue. Following acetonitrile protein precipitation, the analyte was separated using a gradient mobile phase on a reversed‐phase column and analyzed by MS/MS in the multiple reaction monitoring mode using the respective [M + H]+ ions, m/z 683–216 for MLA and m/z 260–116 for the internal standard. The assay exhibited a linear dynamic range of 0.5–250 ng/mL for MLA in rat plasma and brain tissue. The lower limit of quantification was 0.5 ng/mL. Acceptable precision (<12%) and accuracy (100 ± 6%) were obtained for concentrations over the standard curve range. The method was successfully applied to quantify MLA concentrations in a rodent pharmacokinetic and brain penetration study. Copyright © 2011 John Wiley & Sons, Ltd.  相似文献   

9.
A sensitive and specific method using high-performance liquid chromatography (LC)-tandem mass spectrometry (MS) for the analysis of total ribavirin in human red blood cells (RBC) is developed and validated. The method involves the addition of an internal standard and perchloric acid, the conversion of ribavirin phosphorylated metabolites to ribavirin, purification with a solid-phase exchange cartridge, and LC-MS-MS analysis. The MS-MS is selected to monitor m/z 245-113 for ribavirin and m/z 250-113 for [13C]ribavirin using positive electrospray ionization. The calibration curve is linear over a concentration of 100-10,000 ng/mL with a limit of quantitation of 100 ng/mL. Mean interassay accuracy for quality control (QC) at 100, 1000, and 10,000 ng/mL are 101.8%, 99.4%, and 98.8%, respectively. Mean interassay precision (%CV) for QC at 100, 1000, and 10,000 ng/mL are 5.0%, 5.0%, and 2.5%, respectively. Extractibility of total ribavirin from RBC is confirmed with RBC obtained from a [(14)C]ribavirin-dosed monkey. The method is used to determine the free and total ribavirin concentration in human RBC obtained from hepatitis C patients treated with ribavirin.  相似文献   

10.
Topiramate (Topamax®) is an antiepileptic medication used as adjunctive and monotherapy in patients with epilepsy and for migraine prophylaxis. A GC‐MS assay was developed that was capable of detecting topiramate plasma concentrations following a single rectal or oral dose administration. Topiramate plasma samples were prepared by solid‐phase extraction and were quantified by GC‐MS analysis. The topiramate standard curves were split from 0.1 to 4 µg/mL and from 4 to 40 µg/mL in order to give a more accurate determination of the topiramate concentration. The accuracy of the standards ranged from 94.6 to 107.3% and the precision (%CV) ranged from 1.0 to 5.3% for both curves at all concentrations. The %CV for quality controls was <7.6%. The assay is both accurate and precise and will be used to complete future pharmacokinetic studies. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

11.
Capsaicin is the most abundant pungent molecule present in red peppers and it is widely used for food flavoring, in pepper spray in self-defense devices and more recently in ointments for the relief of neuropathic pain. Capsaicin is a selective agonist of transient receptor potential channel, vanilloid subfamily member 1. A selective and sensitive quantitative method for the determination of capsaicin by LC-ESI/MS/MS was developed. The method consisted of a protein precipitation extraction followed by analysis using liquid chromatography electrospray quadrupole ion trap mass spectrometry. The chromatographic separation was achieved using a 100 x 2 mm C(18) Waters Symmetry column combined with a gradient mobile phase composed of acetonitrile and 0.1% formic acid aqueous solution at a flow rate of 220 microL/min. The mass spectrometer was operating in full-scan MS/MS mode using two-segment analysis. An analytical range of 10-5000 ng/mL was used in the calibration curve constructed in rat plasma. The interbatch precision and accuracy observed were 6.5, 6.7, 5.3 and 101.2, 102.7, 103.5% at 50, 500 and 5000 ng/mL, respectively. An in vitro metabolic stability study was performed in rat, dog and mouse liver microsomes and the novel analytical method was adapted and used to determine intrinsic clearance of capsaicin. Results suggest very rapid degradation with T(1/2) ranging from 2.3 to 4.1 min and high clearance values suggesting that drug bioavailability will be considerably reduced, consequently affecting drug response and efficacy.  相似文献   

12.
A sensitive and accurate High-Performance TLC (HPTLC) method has been developed to determine the quantity of 6-gingerol in rhizomes of Zingiber officinale (family: Zingiberaceae), commonly known as ginger. Methanol extracts of rhizomes from three different sources were used for HPTLC, n-hexane, and diethyl ether (40:60 v/v) as the mobile phase. The Rf of 6-gingerol was found to be 0.40. The calibration plot was linear in the range of 250-1200 ng of 6-gingerol and the correlation coefficient of 0.9997 was indicative of good linear dependence of peak area on concentration. The mean quantity of 6-gingerol was found to be 60.44+/-2.53 mg/g of ginger extract. The method permits reliable quantification of 6-gingerol and good resolution and separation of 6-gingerol from other constituents of ginger. To study the accuracy and precision of the method, recovery studies were performed by the method of standard addition. Recovery values from 99.79 to 99.84% showed the excellent reliability and reproducibility of the method. The proposed HPTLC method for quantitative monitoring of 6-gingerol in ginger can be used for routine quality testing of ginger extracts.  相似文献   

13.
In this study, a simple and reliable LC–MS/MS method was first proposed for the simultaneous determination of TUG-891 and its metabolites TUG-891-alcohol, TUG-891-aldehyde, and TUG-891-acid in rat plasma. The analytes and fasiglifam (internal standard) were extracted from plasma samples with acetonitrile and separated using an Acquity BEH C18 column (1.7 μm, 2.1 × 50 mm) with water containing 0.05% ammonium hydroxide and acetonitrile containing 0.05% ammonium hydroxide as the mobile phase. A Q-Exactive Orbitrap mass spectrometer in full-scan mode was used for mass detection, and the data analysis was obtained using a mass extraction window of 5 ppm. The calibration curves exhibited excellent linearity (correlation coefficient > 0.9981) in the concentration range of 0.5–1000 ng/mL. The lower limit of quantification was 0.5 ng/mL for all analytes. The intra- and inter-day precision was less than 11.31%, and the accuracy ranged from −11.50 to 9.50%. The extraction recovery of the analytes from rat plasma was greater than 82.31%, and no obvious matrix effect was found. The established method was further applied to the pharmacokinetic study of TUG-891, TUG-891-alcohol, TUG-891-aldehyde, and TUG-891-acid in rat after a single dose of 5-mg/kg treatment of TUG-891. The results demonstrated that TUG-891 was rapidly metabolized into its metabolites and the systemic exposures of the metabolites were much higher than those of TUG-891.  相似文献   

14.
In the early stage of drug discovery, thousands of new chemical entities (NCEs) may be screened before a single drug candidate can be identified for development. In order to accelerate the drug discovery process, we have developed higher-throughput enzyme assays to evaluate the inhibition of cytochrome P450 isoforms 2D6 (CYP2D6) and 3A4 (CYP3A4) in human liver microsomes. The assays are based on high-performance liquid chromatography/tandem mass spectrometry (LC/MS/MS) techniques. The analysis time for each sample was reduced from approximately 20 minutes for the conventional HPLC assay to 30 seconds for the LC/MS/MS assay. For both LC/MS/MS assays, the linearity (r(2) > 0.99), precision (%CV < 15%) and accuracy (% bias <15%) for both inter- and intraday validations were satisfactory. Since the implementation of the LC/MS/MS assays, our sample throughput has increased by over 40-fold.  相似文献   

15.
A mass spectrometry based method for the simultaneous determination of an in vivo Greenford-Ware or 'GW cocktail' of CYP450 probe substrates and their metabolites in both human plasma and urine is described. The probe substrates, caffeine, diclofenac, mephenytoin, debrisoquine, chlorzoxazone and midazolam, together with their respective metabolites and stable isotope labelled internal standards, are simultaneously extracted from the biological matrix using solid phase extraction in 96-well microtitre plate format, automated by means of a custom built Zymark robotic system. The extracts are analysed by fast gradient high performance liquid chromatography (HPLC) with detection by tandem mass spectrometry (MS/MS) using thermally and pneumatically assisted electrospray ionisation in both positive and negative ion modes and selected reaction monitoring. The methods are specific, accurate and precise with intra- and inter-assay precision (%CV) of less than 15% for all analytes.  相似文献   

16.
A simple plasma extraction method coupled with liquid chromatography–tandem mass spectrometry (LC/MS/MS) detection was developed and validated for the analysis of endogenous mevalonic acid (MVA), a biomarker indicative of the rate of cholesterol biosynthesis, in human plasma samples. The analyte was extracted from the plasma matrix using a straightforward liquid–liquid sample preparation procedure. The extract supernatants were evaporated, reconstituted in aqueous solvent and injected into the LC/MS/MS system without further processing. The chromatographic separation was achieved on a reverse‐phase high‐performance liquid chromatography column. The accuracy and precision of the method was determined over the concentration range 0.25–25 ng/mL MVA from human plasma extracts in three validation batch runs. Inter‐assay precision (%CV) and accuracy (%RE) of the quality control samples were ≤7.00% (at lower limit quality control) and ≤6.10%, respectively. The sensitivity and throughput of this assay was significantly improved relative to previously published methods, resulting in smaller sample requirements and shorter analysis time. Assay results from a clinical study following the oral administration of an exploratory statin demonstrate that this procedure could potentially be used in the investigation of therapies associated with hypercholesterolemia. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

17.
We aimed to investigate the pharmacokinetics, bioavailability and urinary excretion of scopolin and its metabolite scopoletin in rats. An LC–tandem mass spectrometry (MS/MS) method for simultaneous determination of scopolin and scopoletin in rat biomatrices was developed and validated over a plasma and urine concentration range of 5.0–2000 ng/mL. Chromatographic separation was performed on a Hypersil GOLD C18 column with acetonitrile and 0.1% formic acid in water as mobile phase with gradient elution. Detection was performed in the positive ionization and selected reaction monitoring mode. The intra‐ and inter‐batch precision and accuracy, extraction recovery and matrix effect and stability of scopolin and scopoletin were well within the acceptable limits of variation. There was no gender‐related difference in the pharmacokinetic profiles of scopolin. There were significant differences in total area under the concentration–time curve (AUC), time required to achieve a maximal concentration (Tmax) and apparent clearance from plasma (Cl/F) of scopoletin between the male and female rats (p < .05). The bioavailability (F) of scopolin was exceptionally low. The maximal excretion rates were 7.61 μg/h and 7.15 μg/h for scopolin and 31.68 μg/h and 25.58 μg/h for scopoletin in male and female rats, respectively. The LC–MS/MS method was successfully applied to the pharmacokinetic, bioavailability and urinary excretion studies of scopolin and its metabolite scopoletin following a single administration of scopolin to rats.  相似文献   

18.
A method has been developed to quantify chlorpyrifos (O,O-diethyl-O-[3,5,6,-trichloro-2-pyridyl] phosphorothionate) and its metabolites chlorpyrifos-oxon (O,O-diethyl-O-[3,5,6,trichloro-2-pyridinyl] phosphate) and TCP (3,5,6,-trichloro-2-pyridinol) in rat brain tissue by coupled-column liquid chromatography/electrospray ionization tandem mass spectrometry (LC/LC/ESI-MS/MS). Rat brains were homogenized and treated by protein precipitation using ice-cold acetonitrile. The supernatant was directly injected onto the coupled-column system. Sample clean-up was achieved on a Zorbax Extend-C(18) column (2.1 x 50 mm, 5 microm) using a mobile phase of acetonitrile/water with 0.0025% formic acid (40:60, v/v). The compounds were separated isocratically on a Zorbax Eclipse XDB C(8) column (2.0 x 150 mm, 5 microm) using a mobile phase of acetonitrile/water with 0.0025% formic acid (75:25, v/v). Chlorpyrifos and chlorpyrifos-oxon were detected in positive ion mode using multiple reaction monitoring (MRM). TCP was detected in negative ion mode using precursor-to-precursor transition monitoring. The method was validated and the specificity, linearity, limit of quantitation (LOQ), precision, accuracy, stability, and recoveries were determined. Calibration curves for all three analytes yielded correlation coefficients of 0.993 or greater. The LOQs were 25.3 ng/g for chlorpyrifos and 6.3 ng/g for chlorpyrifos-oxon and TCP. All precision relative standard deviations (RSDs) were less than 16% for the LOQ and less than 11% for the other QC samples. This method was successfully applied to six rats that were injected subcutaneously with chlorpyrifos.  相似文献   

19.
A method using zirconia-based column high-performance liquid chromatography (HPLC) interfaced with an atmospheric pressure photoionization (APPI) source and a tandem mass spectrometer (MS/MS) was developed for the quantitative determination of new chemical entities in rat plasma in support of pharmacokinetics studies. The ionization suppression resulting from endogenous components of the biological matrices on the quantitative zirconia-based column HPLC/APPI-MS/MS method was investigated using the post-column infusion technique. The analytical results for 'rapid rat pharmacokinetics' for 12 drug discovery compounds, obtained by both silica-based phase (S-phase) and zirconia-based phase (Z-phase) chromatographic separation, are in good agreement in terms of accuracy. The application of a Z-phase column for high-temperature fast HPLC/MS/MS methods was explored to reduce the analysis time from 3 min to 30 s for column temperatures of 25-110 degrees C, respectively. The chromatographic retention times and peak responses of all analytes were found to be reproducible under high-temperature conditions following 100 continuous injections, with %CV less than 0.4 and 5, respectively.  相似文献   

20.
A liquid chromatography–tandem mass spectrometric (LC‐MS/MS) method was developed and validated for the determination of GDC‐0152 in human plasma to support clinical development. The method consisted of a solid‐phase extraction for sample preparation and LC‐MS/MS analysis in the positive ion mode using TurboIonSprayTM for analysis. d7‐GDC‐0152 was used as the internal standard. A linear regression (weighted 1/concentration2) was used to fit calibration curves over the concentration range of 0.02–10.0 ng/mL for GDC‐0152. There were no endogenous interference components in the blank human plasma tested. The accuracy at the lower limit of quantitation was 99.3% with a precision (%CV) of 13.9%. For quality control samples at 0.0600, 2.00 and 8.00 ng/mL, the between‐run %CV was ≤8.64. Between‐run percentage accuracy ranged from 98.2 to 99.6%. GDC‐0152 was stable in human plasma for 363 days at ?20°C and for 659 days at ?70°C storage. GDC‐0152 was stable in human plasma at room temperature for up to 25 h and through three freeze–thaw cycles. In whole blood, GDC‐0152 was stable for 12 h at 4°C and at ambient temperature. This validated LC‐MS/MS method for determination of GDC‐0152 was used to support clinical studies. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号