1.
Ultrasound parameters (attenuation, phase velocity, and backscatter), bone mineral density (BMD), and microarchitectural features were measured on 29 human cancellous calcaneus samples in vitro. Regression analysis was performed to predict ultrasound parameters from BMD and microarchitectural features. The best univariate predictors of the ultrasound parameters were the indexes of bone quantity: BMD and bone volume fraction (BV/TV). The most predictive univariate models for attenuation, phase velocity, and backscatter coefficient yielded adjusted squared correlation coefficients of 0.69-0.73. Multiple regression models yielded adjusted correlation coefficients of 0.74-0.83. Therefore attenuation, phase velocity, and backscatter are primarily determined by bone quantity, but multiple regression models based on bone quantity plus microarchitectural features achieve slightly better predictive performance than models based on bone quantity alone.  相似文献   

2.
Ultrasound contrast agents (UCAs) are used clinically to aid detection and diagnosis of abnormal blood flow or perfusion. Characterization of UCAs can aid in the optimization of ultrasound parameters for enhanced image contrast. In this study echogenic liposomes (ELIPs) were characterized acoustically by measuring the frequency-dependent attenuation and backscatter coefficients at frequencies between 3 and 30 MHz using a broadband pulse-echo technique. The experimental methods were initially validated by comparing the attenuation and backscatter coefficients measured from 50-μm and 100-μm polystyrene microspheres with theoretical values. The size distribution of the ELIPs was measured and found to be polydisperse, ranging in size from 40 nm to 6 μm in diameter, with the highest number observed at 65 nm. The ELIP attenuation coefficients ranged from 3.7 ± 1.0 to 8.0 ± 3.3 dB/cm between 3 and 25 MHz. The backscatter coefficients were 0.011 ± 0.006 (cm str)(-1) between 6 and 9 MHz and 0.023?±?0.006 (cm str)(-1) between 13 and 30 MHz. The measured scattering-to-attenuation ratio ranged from 8% to 22% between 6 and 25 MHz. Thus ELIPs can provide enhanced contrast over a broad range of frequencies and the scattering properties are suitable for various ultrasound imaging applications including diagnostic and intravascular ultrasound.  相似文献   

3.
The frequency-dependent attenuation and backscatter coefficients were measured in 25 bovine femoral trabecular bone samples from 0.2 to 1.2 MHz. When the average attenuation coefficient was fitted to a nonlinear power law α(f)=α(0)+α(1)f(n), the exponent n was found to be 1.65. In contrast, the average backscatter coefficient was fitted to a power law η(f)=η(1)f(n) and the exponent n was measured as 3.25. The apparent bone density was significantly correlated with the parameter α(1) (0.2-0.7 MHz: r = 0.852, 0.6-1.2 MHz: r = 0.832) as well as the backscatter coefficient (0.5 MHz: r = 0.751, 1.0 MHz: r = 0.808).  相似文献   

4.
Omari E  Lee H  Varghese T 《Ultrasonics》2011,51(6):758-767
Quantitative ultrasound features such as the attenuation slope, sound speed and scatterer size, have been utilized to evaluate pathological variations in soft tissues such as the liver and breast. However, the impact of variations in the sound speed and backscatter due to underlying fat content or fibrotic changes, on the attenuation slope has not been addressed. Both numerical and acoustically uniform tissue-mimicking experimental phantoms are used to demonstrate the impact of sound speed variations on attenuation slope using clinical real-time ultrasound scanners equipped with linear array transducers. Radiofrequency data at center frequencies of 4 and 5 MHz are acquired for the experimental and numerical phantoms respectively. Numerical phantom sound speeds between 1480 and 1600 m/s in increments of 20 m/s for attenuation coefficients of 0.3, 0.4, 0.5, 0.6, and 0.7 dB/cm/MHz are simulated. Variations in the attenuation slope when the backscatter intensity of the sample is equal, 3 dB higher, and 3 dB lower than the reference is also evaluated. The sound speed for the experimental tissue-mimicking phantoms were 1500, 1540, 1560 and 1580 m/s respectively, with an attenuation coefficient of 0.5 dB/cm/MHz. Radiofrequency data is processed using three different attenuation estimation algorithms, i.e. the reference phantom, centroid downshift, and a hybrid method. In both numerical and experimental phantoms our results indicate a bias in attenuation slope estimates when the reference phantom sound speed is higher (overestimation) or lower (underestimation) than that of the sample. This bias is introduced via a small spectral shift in the normalized power spectra of the reference and sample with different sound speeds. The hybrid method provides the best estimation performance, especially for sample attenuation coefficient values lower than that of the reference phantom. The performance of all the methods deteriorates when the attenuation coefficient of the reference phantom is lower than that of the sample. In addition, the hybrid method is the least sensitive to sample backscatter intensity variations.  相似文献   

5.
The current work deals with the use of high-frequency quantitative backscatter acoustic microscopy for the evaluation of the biointegration of microporous polymer implants used as support of artificial cornea. A three-dimensional (3-D) 80 MHz ultrasound microscope (25 microns axial resolution at focus) was used for the imaging and characterization of the progressive biointegration of polymers implanted in rabbit cornea. In-vitro and in-vivo studies were performed. Quantitative assessment of the structural changes in the biomaterial was performed using the spectral analysis of the radio frequency signal and the estimation of acoustic parameters in the 10-65 MHz frequency bandwidth. Correlation of in-vitro ultrasound data with histologic findings has shown that attenuation and backscatter coefficients are sensitive to the changes in the polymer pore content with time. Our results obtained in vivo demonstrated that 3-D 80 MHz echography coupled with quantitative characterization provide a unique tool for the non-invasive and objective follow-up of the implant biointegration and should contribute to clinical management of artificial cornea.  相似文献   

6.
The goal of this work was to determine whether the frequency dependence of apparent backscatter coefficient (not corrected for attenuation within the myocardium) could differentiate completed, remote infarction from acute myocardial injury in vivo. Myocardial infarcts were produced in six dogs by coronary artery occlusion. One to 12 months later, acute ischemic injury was induced in each dog by ligation of a coronary artery that supplied a region of myocardium adjacent to the established infarct. Infarct, ischemic, and normal regions were interrogated with a 5-MHz, circular, 0.5-in. diam, broadband, focused, piezoelectric transducer mounted in a water-filled stand-off device placed against the exposed, beating heart. Apparent backscatter coefficients were measured over the range of frequencies from 3-7 MHz. The frequency dependence was obtained from the slope of log apparent backscatter coefficient versus log frequency. No significant difference in frequency dependence was found between normal and acutely ischemic myocardium for periods of up to 2 h of ischemia. In contrast, frequency dependence in regions of remote infarct (1.8 +/- 0.1, mean +/- standard error) was significantly lower than that in acutely ischemic or nonischemic regions (2.3 +/- 0.1) (p less than 0.01). These results suggest that remote myocardial infarction can be differentiated from acutely injured but still potentially salvageable myocardium in vivo on the basis of the frequency dependence of backscatter.  相似文献   

7.
在超声背散射骨质评价中,不同测量感兴趣区域(ROI)的超声背散射信号会有波动,致使诊断准确度降低。该文目的是研究超声背散射信号随测量区域的变化规律。采用空间扫描方法离体测量了35块骨样本,将超声背散射参数从空间域变换到空间频率域。结果表明,超声背散射参数的主要空间频率成分集中于低频部分;空间频率域超声背散射参量最大值(MASF)与骨矿密度等参数具有中高度显著相关性(R2=0.45~0.83,p0.001);空间频率域超声背散射参量衰减系数(AC)也与松质骨密度及结构特征有显著相关性(R2=0.41~0.72,p0.001)。研究表明空间频率域变换方法有助于明确超声背散射信号随测量ROI的变化规律,空间频率域的超声背散射相关新参量评价松质骨状况具有可行性。  相似文献   

8.
The use of ultrasonic acoustic technology to measure the concentration of fine suspended sediments has the potential to greatly increase the temporal and spatial resolution of sediment measurements while reducing the need for personnel to be present at gauging stations during storm events. The conversion of high-frequency attenuation and backscatter amplitudes to suspended silt and clay concentration has received relatively little attention in the literature. In order to improve the state of knowledge, a laboratory investigation was undertaken by the National Center for Physical Acoustics in cooperation with the USDA-ARS National Sedimentation Laboratory. In these experiments, two immersion transducers were used to measure attenuation and backscatter from 20 MHz acoustic signals propagated through suspended clay (smectite and kaolinite) and silt particles. The resulting data includes attenuation values for a wide range of concentrations (0.3–14 g/L) and particle sizes (0.03–14 μm diameter). Attenuation curves for each particle were compared to the theoretical attenuation curves developed by Urick (1948) and Sheng and Hay (1988) for scattering as presented by Landers (2010) [5,11,12]. In addition, it was found that the backscatter signal could be used to discriminate between suspensions dominated by clay or silt.  相似文献   

9.
降雨对C波段散射计测风的影响及其校正   总被引:1,自引:0,他引:1       下载免费PDF全文
周旋  杨晓峰  李紫薇  于旸  马胜 《物理学报》2012,61(14):149202-149202
传统观点认为C波段散射计工作波长大于雨滴直径,受降雨散射衰减的影响很小, 因此往往忽略降雨对C波段散射计测风的影响.本文基于降雨引起C波段散射计信号的衰减、 后向体散射及雨滴落入海面后的扰动作用,推导了降雨条件下的雷达方程, 构建了2010年全年的ASCAT散射计、降雨雷达和欧洲中期天气预报中心数值预报的匹配数据集, 定量分析了降雨对C波段散射计测风的影响,发现其信号衰减随降雨强度和入射角的增大而增强; 后向体散射和雨表面扰动作用随降雨强度的增大而增强、随入射角的增大而减小, 其中雨表面扰动作用对散射计测风的影响大于后向体散射.另外, 利用降雨条件下的雷达方程和匹配数据集,本文建立了降雨条件下的C波段主动微波辐射传输模型, 实验表明,该模型能够改善降雨条件下C波段散射计测风的精度.  相似文献   

10.
The ability to enhance specific molecular markers of pathology with ultrasound has been previously demonstrated by our group employing a nanoparticle contrast agent [Lanza et al., Invest. Radiol. 35, 227-234 (2000); Ultrasound Med. Biol. 23, 863-870 (1997)]. One of the advantages of this agent is very low echogenicity in the blood pool that allows increased contrast between the blood pool and the bound, site-targeted agent. We measured acoustic backscatter and attenuation coefficient as a function of the contrast agent concentration, ambient pressure, peak acoustic pressure, and as an effect of duty cycle and wave form shape. Measurements were performed while the nanoparticles were suspended in either whole porcine blood or plasma. The nanoparticles were only detectable when insonified within plasma devoid of red blood cells and were shown to exhibit backscatter levels more than 30 dB below the backscatter from whole blood. Attenuation of nanoparticles in whole porcine blood was not measurably different from that of whole blood alone over a range of concentrations up to eight times the maximum in vivo dose. The resulting data provide upper bounds on blood pool attenuation coefficient and backscatter and will be needed to more precisely define levels of molecular contrast enhancement that may be obtained in vivo.  相似文献   

11.
This paper presents a new approach that has been developed to identify individual aerosol species using polarization lidar measurements. Individual aerosols can be identified based on their distinct ratios of extinction to backscatter, which are related to the depolarization ratio profile. Aerosol backscatter coefficients can be obtained from these ratios. Differential aerosol backscatter coefficients are proportional to the variation of the ratio of extinction to backscatter coefficient, and the coefficients increase, reach a peak value, and then decrease again, with increasing range.  相似文献   

12.
A weak scattering model was proposed for the ultrasonic frequency-dependent backscatter in dense bovine cancellous bone, using two autocorrelation functions to describe the medium: one with discrete homogeneities (spherical distribution of equal spheres) and another, which considers tissue as an inhomogeneous continuum (densely populated medium). The inverse problem to estimate trabecular thickness of bone tissue has been addressed. A combination of the two autocorrelation functions was required to closely approximate the backscatter from bovine bone with various microarchitecture, given that the shape of trabeculae ranges from a rodlike to a platelike shape. Because of the large variation in trabecular thickness, both at an intraspecimen and an interspecimen level, thickness distributions for individual trabeculae for each bone specimen were obtained, and dominant trabecular sizes were determined. Comparison of backscatter measurements to theoretical predictions indicated that there were more than one dominant trabecular sizes that scatter sound for most specimens. Linear regression, performed between dominant trabecular thickness and estimated correlation length, showed significant linear correlation (R(2)=0.81). Attenuation due to scattering by a continuous distribution of scatterers was predicted to be linear over a frequency range from 0.3 to 0.9 MHz, suggesting a possibility that scattering may be a significant source of attenuation.  相似文献   

13.
The objective of this study was to measure the backscatter coefficient of formalin-fixed myocardial tissue as a function of angle of insonification relative to the myocardial fiber direction. Backscatter measurements were performed on eight cylindrical formalin-fixed lamb myocardial specimens and compensated for attenuation and diffraction effects to determine the backscatter coefficient. The backscatter coefficient at 5 MHz was found to be maximum for insonification perpendicular to the predominant myofiber orientation and minimum for parallel insonification, with values of (17+/-14) and (1.2+/-0.7) x 10(-4) cm(-1) sr(-1) (mean+/-standard deviation), respectively.  相似文献   

14.
骨小梁材料特性对超声背散射信号的影响   总被引:1,自引:0,他引:1       下载免费PDF全文
基于时域有限差分法(FDTD)建立了松质骨的超声背散射仿真系统,研究了骨小梁材料特性对超声背散射信号的影响。首次得到松质骨中的超声背散射系数(BSC)和积分背散射系数(IBC)随骨小梁材料参数(密度、拉梅常数、黏度系数及声阻抗系数)的变化关系。研究结果表明,IBC随骨小梁密度的增加而增加;BSC和IBC随拉梅常数的增加而增加、随第一黏度系数的增加而近似线性地减小,第二黏度的变化对背散射信号的影响很小;背散射参数随阻抗系数的增加而减小。说明松质骨中的超声背散射特性不仅受骨矿密度(BMD)和骨微结构的影响,还与骨小梁的材料参数密切相关。研究结果有利于理解松质骨中超声的背散射特性,对松质骨骨质状况的评价有一定帮助。   相似文献   

15.
Although bone sonometry has been demonstrated to be useful in the diagnosis of osteoporosis, much remains to be learned about the processes governing the interactions between ultrasound and bone. In order to investigate these processes, ultrasonic attenuation and backscatter in two orientations were measured in 43 human calcaneal specimens in vitro at 500 kHz. In the mediolateral (ML) orientation, the ultrasound propagation direction is approximately perpendicular to the trabecular axes. In the anteroposterior (AP) orientation, a wide range of angles between the ultrasound propagation direction and trabecular axes is encountered. Average attenuation slope was 18% greater while average backscatter coefficient was 50% lower in the AP orientation compared with the ML orientation. Backscatter coefficient in both orientations approximately conformed to a cubic dependence on frequency, consistent with a previously reported model. These results support the idea that absorption is a greater component of attenuation than scattering in human calcaneal trabecular bone.  相似文献   

16.
Padilla F  Jenson F  Laugier P 《Ultrasonics》2006,44(Z1):e57-e60
The goal of this study is to propose a model for the ultrasonic frequency-dependent backscatter coefficient in femoral cancellous bone. This model has been developed with success to predict backscatter in human calcaneal bone [Jenson, Ultr. Med. Biol. 2003]. A weak scattering model is used and the backscatter coefficient is expressed in terms of a Gaussian autocorrelation function of the medium. The backscatter coefficient is computed and comparison is made with experimental data for 37 specimens and for frequency ranging from 0.4 to 1.2 MHz. An excellent agreement between experimental data and predictions is found for both the magnitude and the frequency-dependence of the backscatter coefficient. Then, a nonlinear regression is performed for each specimen, and the mean trabecular thickness is estimated. Experimental data and theoretical predictions are averaged over the 37 specimens. We also find a close agreement between theoretical predictions obtained using the Gaussian autocorrelation function (scatterer size=134+/-15 microm) and the mean trabecular thickness (Tb.Th=132+/-12 microm) derived from the analysis of bone 3-D micro-architecture using high-resolution micro-tomography. However, the correlation between individual experimental and estimated Tb.Th values is moderate (R(2)=0.44). The performance of the estimator are limited mainly by two factors: interference noise due to random positioning of the scatterers and attenuation. We show that the fundamental limitation of our estimator due to the speckle noise is around 5 microm for trabecular thickness estimation. This limitation is lower than the observed biological variability which is around 30 microm and should not be a limiting factor for individual prediction. A second limitation is the tremendous attenuation encountered in highly scattering media such as cancellous bone, which results in highly damped backscatter signals. The compensation for attenuation is difficult to perform, and it may be a critical point that limits the precision of the estimator.  相似文献   

17.
为实现水平非均匀分布的低层大气气溶胶光学特性的遥感探测,提出一种基于双扫描激光雷达的气溶胶精细探测方法.该方法以扫描激光雷达为遥感探测工具,通过双激光雷达相向交叉扫描工作模式,实现对同一空域近地表气溶胶全视野剖面的交叉探测,从而提供双激光雷达方程组以精确求解气溶胶消光和后向散射系数.在数据反演过程中,通过对交叉扫描区域进行坐标化和网格化处理、网格像素单元的初值预设,以及双扫描激光雷达方程组的数值逼近反演得到气溶胶消光.利用长距离扫描激光雷达的数据对该方法进行验证,结果表明,该方法与多角度方法反演所得到的结果随高度变化的趋势具有高度的一致性;同时双扫描激光雷达可提供交叉扫描区域剖面的气溶胶浓度分布,相比于单条廓线具有较大的优势.  相似文献   

18.
Results of experiments performed in several laboratories indicate that contracting myocardium exhibits a cyclic variation of the magnitude of ultrasonic backscatter, with maxima occurring at end-diastole and minima at end-systole. The mechanisms responsible for this variation are not well understood. The purpose of the present study was to determine whether the frequency dependence of backscatter exhibits systematic variation throughout the cardiac cycle, analysis of which may facilitate improved understanding of biologic factors responsible for the cyclic variation of the magnitude of backscatter. In this study, the myocardial backscatter coefficient, as a function of frequency, was measured throughout the cardiac cycle in nine open-chest dogs. The frequency dependence of the backscatter coefficient was computed from a least-squares linear fit to log backscatter coefficient versus log frequency data. A cyclic variation of frequency dependence of backscatter was found with maximum near end-diastole (f2.6 +/- 0.1) and minimum near end-systole (f2.2 +/- 0.1), a significant variation (p less than 0.01). These results suggest that mechanisms responsible for the cyclic variation of backscatter may include changes in the effective size of the dominant scatterers throughout the cardiac cycle. An alternative explanation for the observed variation is an increase in the myocardial attenuation coefficient during systole followed by a decrease in diastole.  相似文献   

19.
In this study, ultrasonic backscattering signals in cancellous bones were obtained by finite difference time domain (FDTD) simulations, and the effect of trabecular material properties on these signals was analyzed. The backscatter coefficient (BSC) and integrated backscatter coefficient (IBC) were numerically investigated for varying trabecular bone material properties, including density, Lame coefficients, viscosities, and resistance coefficients. The results show that the BSC is a complex function of trabecular bone density, and the IBC increases as density increases. The BSC and IBC increase with the first and second Lame coefficients. While not very sensitive to the second viscosity of the trabeculae, the BSC and IBC decrease as the first viscosity and resistance coefficients increase. The results demonstrate that, in addition to bone mineral density (BMD) and microarchitecture, trabecular material properties significantly influence ultrasonic backseattering signals in cancellous bones. This research furthers the understanding of ultrasonic backscattering in cancellous bones and the characterization of cancellous bone status.  相似文献   

20.
An experimental model which can simulate physical changes that occur during aging was developed in order to evaluate the effects of change of mineral content and microstructure on ultrasonic properties of bovine cancellous bone. Timed immersion in hydrochloric acid was used to selectively alter the mineral content. Scanning electron microscopy and histological staining of the acid-treated trabeculae demonstrated a heterogeneous structure consisting of a mineralized core and a demineralized layer. The presence of organic matrix contributed very little to normalized broadband ultrasound attenuation (nBUA) and speed of sound. All three ultrasonic parameters, speed of sound, nBUA and backscatter coefficient, were sensitive to changes in apparent density of bovine cancellous bone. A two-component model utilizing a combination of two autocorrelation functions (a densely populated model and a spherical distribution) was used to approximate the backscatter coefficient. The predicted attenuation due to scattering constituted a significant part of the measured total attenuation (due to both scattering and absorption mechanisms) for bovine cancellous bone. Linear regression, performed between trabecular thickness values and estimated from the model correlation lengths, showed significant linear correlation, with R(2)=0.81 before and R(2)=0.80 after demineralization. The accuracy of estimation was found to increase with trabecular thickness.  相似文献   