1.
The oxidation of formaldehyde on a platinum (Pt)–palladium (Pd)–graphene nanocomposite glassy carbon electrode prepared by chemical reduction was characterized in 0.5?M sulfuric acid. The surface and morphology of the catalyst were characterized by transmission electron microscopy, Raman spectroscopy, and X-ray diffraction. Bimetallic Pt–Pd nanoparticles were uniformly dispersed on the graphene sheets. Energy-dispersed X-ray spectroscopy was used to characterize the metal composition of the nanocomposite. The electrocatalytical characteristics of the modified electrode were investigated by cyclic voltammetry. The results show that the electrode displayed high activity for the oxidation of formaldehyde in sulfuric acid with a linear relationship from 4.50?µM to 0.180?mM and a detection limit of 2.85?µM. The low detection limit, wide linear dynamic range, and high sensitivity of the modified electrode suggests further applications.  相似文献   

2.
The study presents a novel paracetamol (PA) sensor based on Pd nanoparticles (PdNPs) deposited on carboxylated graphene oxide (GO?COOH) and nafion (Nf) modified glassy carbon electrode (GCE). The morphologies of the as prepared composites were characterized using high resolution transmission electron microscopy (HRTEM), scanning electron microscopy (SEM), X‐ray diffraction (XRD), X‐ray photoelectron spectroscopy (XPS), and fourier transform infrared spectroscopy (FTIR). The experimental results demonstrated that Nf/GO?COOPd displayed excellent electrocatalytic response to the oxidation PA. The linear range was 0.04–800 μM for PA with limit of detection of 0.012 μM and excellent sensitivity of 232.89 μA mM?1 cm?2. By considering the excellent performance of Nf/GO?COOPd composite such as wider linear range, lower detection, better selectivity, repeatability, reproducibility, and storage stability, the prepared composite, especially GO?COOH support, with satisfactory electrocatalytic properties was a promising material for the modification of electrode material in electrochemical sensor and biosensor field.  相似文献   

3.
采用改进的Hummers法和硼氢化钠还原法制备Pd/石墨烯催化剂,并采用XRD、SEM、XPS、TEM等技术对其进行表征. 将该催化剂修饰于玻碳电极表面,制备出Pd/石墨烯/玻碳电极,使用循环伏安法研究了检测4-氯酚的最佳工作条件. 研究结果表明,所得石墨烯表面平整光滑,以零价态存在的Pd纳米颗粒均匀分散到石墨烯上,平均粒径为(6.5 ± 0.05) nm. 检测4-氯酚的最佳支持电解质为0.1 mol?L-1、pH = 6.8的磷酸-磷酸钠缓冲溶液(PBS),峰电流与扫描速率的平方根呈良好的线性关系(R2 = 0.992),该电极的线性范围为1 ~ 100 μmol?L-1 (R2 = 0.967),检测限为0.57 μmol?L-1 (S/N = 3),且具有良好的重现性和稳定性. 本文所研制的Pd/石墨烯/玻碳电极具有较高的催化活性,提供了一种简便快捷、重现性好的检测4-氯酚的方法.  相似文献   

4.
 A promising electrochemical sensor was fabricated by electrodeposition of Pd nanoparticles (PdNPs) on poly(thiophene-3-acetic acid) (PTAA)-modified glassy carbon electrode (GCE), forming a PdNPs/PTAA composites-modified GCE (PdNPs/PTAA/GCE). Scanning electron microscope (SEM) and electrochemical techniques were used for the characterization of these composites. It was found that the PdNPs/PTAA layer was very uniform. Electrochemical experiments showed that this proposed PdNPs/PTAA composites-modified electrode exhibited excellent electrocatalytic activity towards the oxidation of hydrazine. Under the optimum conditions, the proposed sensor can be applied to the quantification of hydrazine with a wide linear range from 8.0?10-9 mol/L to 1.0?10-5 mol/L with a low detection limit of 2.67?10-9 mol/L. The experiment results also showed that the sensor exhibited good reproducibility and long-term stability, as well as high selectivity with no interference from other potential competing species.  相似文献   

5.
《Electroanalysis》2017,29(5):1258-1266
The nanoporous graphene papers (NGPs) was prepared by the hard‐template method. The Pt−Pd modified NGPs hybrid was prepared by the self‐assembly method. Then a glassy carbon electrode (GCE) modified with Pt−Pd bimetallic nanoparticles‐functionalized nanoporous graphene composite has been prepared for the electrochemical determination of Xanthine (XA). The Pt−Pd/NGPs hybrid was characterized by transmission electron microscopy, scanning electron microscope and X‐ray diffraction. The electrochemical behavior of XA on Pt−Pd/NGPs/GCE was investigated by cyclic voltammetry and amperometric i‐t. The Pt−Pd/NGPs modified electrode exhibited remarkably electrocatalytic activity towards the oxidation reaction of XA in phosphate buffer solution (pH=5.5). Under the optimal conditions, the determination of XA was accomplished by using amperometric i‐t, the linear response range from 1.0×10−5∼1.2×10−4 M. The detection limit was 3.0×10−6 M (S/N=3). The proposed modified electrode showed good sensitivity, selectivity, and stability with applied to determine XA in human urine.  相似文献   

6.
Carbon-supported palladium nanostructures have had a recent rise in their use for ethanol oxidation applications. In this work, we present the use of unsupported palladium nanoparticles (PdNPs), synthesized by sodium borohydride chemical reduction method, for ethanol electrochemical sensing. The unsupported PdNPs were studied for ethanol oxidation in alkaline media by cyclic voltammetry, and additionally were characterized using transmission electron microscopy, and x-ray photoelectron spectroscopy. The performance of unsupported PdNP-modified glassy carbon electrodes for the electrochemical ethanol oxidation in 1.0 M potassium hydroxide (KOH) solution was studied by cyclic voltammetry. These electrochemical results demonstrated that the unsupported PdNPs have very promising catalytic activity towards the oxidation of ethanol in alkaline media with good detection performance in the concentration range of 2304 to 288 ppm (i.e., 50.00 to 6.25 mM). The detection limit and linear correlation coefficient were 49.3 ppm (1.10 mM) and 0.9998, respectively. The unsupported PdNP-modified glassy carbon electrodes presented good cyclic voltammetric stability for ethanol sensing application in alkaline media.  相似文献   

7.
We report on the electrodeposition of palladium nanoparticles (PdNPs) on a glassy carbon electrode (GCE) and onto a poly‐CoTAPc‐GCE (CoTAPc=cobalt tetraamino phthalocyanine) surface. The electrodes are denoted as PdNPs‐GCE and PdNPs/poly‐CoTAPc‐GCE, respectively. PdNPs/poly‐CoTAPc‐GCE showed the best activity for the oxidation of hydrazine at the lowest potential of ?0.28 V and with the highest currents. The results were further supported by electrochemical impedance spectroscopy (EIS) which showed that there was less resistance to charge transfer for PdNPs/poly‐CoTAPc‐GCE compared to PdNPs‐GCE. The catalytic rate constant for hydrazine oxidation was 6.12×108 cm3 mol?1 s?1 using PdNPs/poly‐CoTAPc‐GCE.  相似文献   

8.
The graphene oxide (GO) nanosheets were produced by chemical conversion of graphite, and were characterized by transmission electron microscope (TEM), Fourier transform infrared spectroscopy (FT-IR). An electrochemical sensor based on Ni/graphene (GR) composite film was developed by incorporating Ni2+ into the graphene oxide film modified glassy carbon electrode (Ni/GO/GCE) through the electrostatic interactions with negatively charged graphene oxide. The Ni2+/graphene modified glassy carbon electrode (Ni/GR/GCE) was prepared by cyclic voltammetric scanning of Ni/GO/GCE in the potential range from ?1.5 to 0.2 V at 50 mV s?1 for 5 cycles. The electrochemical activity of Ni/GR/GCE was illustrated in 0.10 M NaOH using cyclic voltammetry. The Ni/GR/GCE exhibits the characteristic of improved reversibility and enhanced current responses of the Ni(III)/Ni(II) couple. The introduction of conductive graphene not only greatly facilitates the electron transfer of Ni2+, but also dramatically improves the long-term stability of the sensor by providing the electrostatic interactions. Ni/GR/GCE also shows good electrocatalytic activity toward the oxidation of glucose. The Ni/GR/GCE gives a good linear range over 10 to 2700 μM with a detection limit of 5 μM towards the determination of glucose by amperometry. This sensor keeps over 85% activity towards 0.1 mM glucose after being stored in air for a month, respectively. Furthermore, the modified sensor was successfully applied to the sensitive determination of glucose in blood samples.  相似文献   

9.
《Electroanalysis》2017,29(11):2591-2601
In present work, reduced graphene oxide nanosheets (rGO) decorated with trimetallic three‐dimensional (3D) Pt−Pd−Co porous nanostructures was fabricated on glassy carbon electrode (Pt−Pd−Co/rGO/GCE). First, GO suspension was drop‐casted on the electrode surface, then GO film reduction was carried out by cycling the potential in negative direction to form the rGO film modified GCE (rGO/GCE). Then, electrodeposition of the cobalt nanoparticles (CoNPs) as sacrificial seeds was performed onto the rGO/GCE by using cyclic voltammetry. Afterward, Pt−Pd−Co 3D porous nanostructures fabrication occurs through galvanic replacement (GR) method based on a spontaneous redox process between PtCl2, PdCl2, and CoNPs. The morphology and structure of the Pt−Pd−Co/rGO porous nanostructure film was characterized by scanning electron microscopy, energy dispersive spectroscopy and X‐ray diffraction method. The performance of the prepared electrode was investigated by various electrochemical methods including, cyclic voltammetry and electrochemical impedance spectroscopy. The electrocatalytic activity of the as‐prepared modified electrode with high surface areas was evaluated in anodic oxidation of ethylene glycol. The study on electrocatalytic performances revealed that, in comparison to various metal combinations in modified electrodes, trimetallic Pt−Pd−Co/rGO/GCE exhibit a lower onset potential, significantly higher peak current density, high durability and stability for the anodic oxidation of ethylene glycol. The excellent performances are attributed to the rGO as catalysts support and resulting synergistic effects of the trimetallic and appropriate characteristics of the resulted 3D porous nanostructures. Moreover, the influence of various concentrations of ethylene glycol, the potential scan rate and switching potential on the electrode reaction, in addition, long‐term stability have been studied by chronoamperometric and cyclic voltammetric methods.  相似文献   

10.
This work reports the preparation, characterization, and electrocatalytic characteristics of a new metallic nanocatalyst. The catalyst, Pt black–graphene oxide (Pt-GO), was prepared by deposition of Pt black on the surface of graphene oxide nanosheet and characterized by transmission electron microscopy (TEM), energy-dispersive spectroscopy (EDS), and voltammetry. The Pt-graphene (Pt-GR) composite modified glassy carbon electrode (Pt-GR/GCE) was prepared with cyclic voltammetric scanning of Pt-GO/GCE in the potential range from ?1.5 to 0.2 in 0.1 M phosphate buffer solution at 50 mV·s?1 for 5 cycles. The electrocatalytic properties of the Pt-GR/GCE for methanol (CH3OH) oxidation have been investigated by cyclic voltammetry (CV); high electrocatalytic activity of the Pt-GR/GCE can be observed. This may be attributed to the high dispersion of Pt catalyst and the particular properties of GR support. The long-term stability of Pt-GR composite was investigated in 0.05 M CH3OH in 0.1 M H2SO4 solution. It can be observed that the peak current decreases gradually with the successive scans. The loss may result from the consumption of methanol during the CV scan. It also may be due to the poisoning organic compounds. The results imply that the Pt-GR composite has good potential applications in fuel cells.  相似文献   

11.
This work presents a sensitive voltammetric method for determination of the flavonoid baicalein by using a thermally reduced graphene oxide (TRGO) modified glassy carbon electrode (GCE) in 100 mM KCl‐10 mM sodium phosphate buffer solution (pH 7.40). The surface morphology and structure of TRGO investigated by atomic force microscopy, FT‐IR spectroscopy and Raman spectroscopy reveal that the TRGO prepared maintained as single or bilayer sheets and with significant edge‐plane‐like defect sites. The TRGO/GCE modified electrode shows more favorable electron transfer kinetics for potassium ferricyanide and potassium ferrocyanide probe molecules, which are important electroactive compounds, compared with bare GCE and GO/GCE electrodes. The electrochemical behaviors of baicalein at the TRGO/GCE were investigated by cyclic voltammetry, suggesting that the TRGO/GCE exhibits excellent electrocatalytic activity to baicalein. Under physiological conditions, the modified electrode showed linear voltammetric response from 10 nM to 10 µM for baicalein, with a detection limit of 6.0 nM. This work demonstrates that the graphene‐modified electrode is a promising tool for electrochemical determination of flavonoid drugs.  相似文献   

12.
Three reduced graphene oxide nanocomposites were employed to achieve the simultaneous electrochemical determination of multi-drugs including acetaminophen (ACTM), carbendazim (CB) and ciprofloxacin (CFX). All nanocomposite modified electrodes showed improved current responses for three drugs. Notably cauliflower-like platinum nanoparticles decorated reduced graphene oxide modified electrode (or Pt−RGO/GCE) exhibited the best performance in terms of electrochemical stability. Using Pt−RGO/GCE, the linear detect ranges of 30–120 μM, 25–115 μM and 10–25 μM, and detection limit values of 3.49, 2.96, and 1.53 μM were achieved for ACTM, CB and CFX respectively. The electrode was further used for the successful determination of above drugs in tap and river water using differential pulse voltammetry. From the obtained results, we believe that Pt-RGO/GCE is highly promising for the fabrication of robust electrochemical sensors for simultaneously determining ACTM, CB and CFX or similar types of drugs in the future.  相似文献   

13.
A novel and useful method to catalyze the electro‐oxidation of nicotinamide adenine dinucleotide (NADH) over a glassy carbon electrode (GCE) modified with graphene oxide (GO) is presented. Based on the presence of oxygen moieties in GO, which can be easily reduced, an in situ electrochemical generation of reduced graphene oxide (denoted as erGO) applying a sufficient negative potential. A potential of ?1.000 V was selected to generate the erGO/GCE as a pretreatment potential before the detection of NADH. The in situ generated erGO/GCE system produces a decrease in the overpotential of NADH oxidation from +0.720 V to +0.230 V compared with GCE. The process also produced an important increase in current signals. The modified electrode was characterized by scanning electron (SEM) and electrochemical microscopies (SECM), cyclic voltammetry and by Raman spectroscopy. Amperometric detection of NADH via this straightforward electrocatalytic method provides a wide linear range between 10 and 100 μM, a lower detection limit of 0.36 μM and an excellent sensitivity of (1.47±0.09) μA mM?1.  相似文献   

14.
Pristine palladium nanoparticles were decorated on graphene nanosheets for the development of a low-cost, nonenzymatic ethanol sensor. The nanocomposite was characterized by ultraviolet–visible absorbance spectroscopy, infrared spectroscopy, and field emission scanning electron microscopy equipped with energy dispersive X-ray spectroscopy. Cyclic voltammetry and chronoamperometry were used to quantify ethanol in alkaline media. A graphene palladium nanocomposite-modified glassy carbon electrode provided a detection limit of 2?mM with a linear dynamic range of 2–210?mM for ethanol determination. The nanocomposite exhibited excellent stability for 100 cyclic voltammetry scans. Ethanol oxidation was performed across a range of temperatures, unlike enzymatic based sensors. Moreover, the catalytic material showed a low activation energy and low onset potentials for the oxidation of ethanol. Interference studies with congeners of ethanol in fermentation chambers showed good selectivity for the analyte. The enhanced catalytic activity for ethanol detection involves the combination of pristine palladium nanoparticles with the enhanced conductivity of graphene.  相似文献   

15.
In this study, a 3Au? 1Pd alloy nanoparticles/graphene composite (3Au? 1Pd alloy NPs/GN) with carboxyl groups and hydroxyl groups was prepared facilely by co‐reduction of graphene oxide (GO), HAuCl4, K2PdCl4, with an Au? Pd alloy molar ratio of 3 : 1. The composite modified glass carbon electrode (GCE) showed a good performance for detecting bisphenol A (BPA) due to the enhanced electron transfer kinetics and large active surface area. The effective enrichment of BPA is attributed to the carboxyl groups and hydroxyl groups on the composite. According to the results of differential pulse voltammetry (DPV), the BPA oxidation current is linear to its concentration in the range of 10 nM–5.0 µM (R=0.998), and the detection limit is found to be 4.0 nM (S/N=3).  相似文献   

16.
This work presents a sensitive voltammetric method for determination of curcumin by using a electrochemically reduced graphene oxide (ERGO) modified glass carbon electrode (GCE) in 100 mM KCl‐10 mM sodium phosphate buffer solution (pH 7.40). The electrochemical behaviors of curcumin at ERGO/GCE were investigated by cyclic voltammetry, suggesting that the ERGO/GCE exhibits excellent electrocatalytic activity towards curcumin, compared with bare GCE and GO/GCE electrodes. The electrochemical reaction mechanisms of curcumin, demethoxycurcumin and bisdemethoxycurcumin at the ERGO/GCE were also investigated and discussed systematically. Under physiological condition, the modified electrode showed linear voltammetric response from 0.2 μM to 60.0 μM for curcumin, with the detection limit of 0.1 μm. This work demonstrates that the graphene‐modified electrode is a promising strategy for electrochemical determination of biological important phenolic compounds.  相似文献   

17.
Alloxan is a toxic reagent that strongly induces the diabetes by destroying insulin‐producing β‐cells in the pancreas of living organisms. The reduction product of alloxan is dialuric acid, which is responsible for the intracellular generation of ROS to enhance the stress in living cells to cause kidney disease or diabetic nephropathy. Herein, we studied for the first time the electrochemical properties of alloxan on reduced graphene oxide modified glassy carbon electrode (rGO/GCE) in 0.1 M phosphate buffer solution (PBS) at pH 7. The obtained results were compared with graphene oxide modified GCE (GO/GCE) and bare GCE surfaces. The modified rGO/GCE showed well defined redox couple with 10 fold increase in both reduction as well as oxidation peak current for alloxan than that of GO/GCE and bare GCE. Differential pulse voltammetry (DPV) technique shows the linear increase in both oxidation and reduction peak current of alloxan in the range of 30 μM to 3 mM with LOD of 1.2 μM. An amperometric signal of alloxan is also increases with respect to each addition of 50 μM of alloxan on rGO/GCE at constant potential of ?0.05 V. The linear range of alloxan is observed between 50 μM to 750 μM (S/N=3). This kind of rGO/GCE surface is more suitable platform or sensor matrix for estimating unknown concentration of alloxan molecule in the real biological systems.  相似文献   

18.
Over the past years, the development of electrochemical sensing platforms for the sensitive detection of drug molecules have received great interests. In this research study, we introduced cauliflower‐like platinum particles decorated reduced graphene oxide modified glassy carbon electrode (Pt?RGO/GCE) as an electrochemical sensing platform for highly sensitive determination of acetaminophen (ACTM). The sensor was prepared via a simple and environmentally friendly two‐step electrodeposition method at room temperature. The combination of conductive RGO nanosheets and unique structured Pt particles (average 232 nm in diameter) provided an efficient interface with large effective surface area which greatly facilitated the electron transfer of ACTM. The experimental conditions that might affect the drug detection were studied in detail and optimized for best performance. The Pt?RGO/GCE was able to detect ACTM up to the limit of 2.2 nM with a linear concentration range from 0.01 to 350 μM. With its high reproducibility, excellent stability and selectivity, the as‐fabricated sensor was successfully applied to the ACTM content measurement in commercial tablets.  相似文献   

19.
In this study, a novel material, palladium nanoparticles-carboxylic functional carbon nanotubes (PdNPs-CFCNTs), based on PdNPs supported on CFCNTs was synthesized by a facile spontaneous redox method. The material reveals high electrochemical activity and excellent catalytic characteristic for alcohol electrooxidation on a glassy carbon electrode (GCE) in an alkaline medium. The preparation mechanism was studied by the galvanic cell effect between PdCl42− and functional defect sites on CFCNTs. Results from UV-visible absorption spectroscopy and electrochemical impedance spectroscopy revealed that the reduction of PdCl42− to metallic Pd was successfully achieved. Morphologies of PdNPs supporting on CFCNTs (PdNPs-CFCNTs) were also characterized by transmission electron micrograph. PdNPs-CFCNTs with the best electrocatalytic characteristics were obtained under the condition as: the weight ratio of Pd to CFCNTs was kept at 2:1, the temperature was kept at 70 °C in the synthesis, and the scan rate of the applied potential was selected at 60 mV s−1. The results indicate that PdNPs-CFCNTs could be a great potential material in direct ethanol fuel cells and ethanol sensors.  相似文献   

20.
该文以氧化石墨烯和氯铂酸混合液为前驱体,采用一步电沉积法制备了纳米铂/还原氧化石墨烯修饰电极(Pt/E-rGO/GCE),通过差分脉冲伏安法对1-羟基芘进行原位富集检测。结果表明,当溶液pH 2.0,制备Pt/E-rGO/GCE的电沉积圈数为5圈时,在50~700 nmol/L范围内,1-羟基芘浓度与还原峰电流呈线性关系,相关系数(r)为0.976,检出限(S/N=3)为12.1 nmol/L。该方法的稳定性、重现性及抗干扰能力良好,将其应用于尿样的检测,回收率为99.7%~108%,相对标准偏差为3.2%~4.2%。Pt/E-rGO/GCE的良好性能对电化学传感器的构建具有一定的实用价值。  相似文献   