首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 390 毫秒
1.
The utility of ion beam analysis (IBA) techniques to quantitatively determine impurities in carbon nanotubes (CNTs) over a wide range of atomic numbers is demonstrated. Such techniques have not previously been used to monitor impurities and their effects in this unique material. Despite the difficulty in mounting the samples (which generally are formed into a powdery aggregate rather in a thin film), it is shown that reliable and accurate measurements of impurity concentrations can be achieved. Particle-induced X-ray emission (PIXE) and elastic recoil detection (ERD) analyses were used to characterize both metallic and very light (e.g., hydrogen) impurities in CNTs. This paper reports the first direct measurement of hydrogen in CNTs using an IBA technique. This is significant because CNTs are being actively investigated for hydrogen storage technology for energy applications.  相似文献   

2.
The application of reflectance measurements to the determination of impurities in pesticides after separation by thin-layer chromatography has been investigated. The procedure is useful for direct, specific and quantitative determination of all impurities which are separable by thin-layer chromatography. For some examples detection limits, wave lengths of measurements and standard deviations have been calculated. Even impurities of only 0.1% may be detected quantitatively. Standard deviations are in the range of about 5% (1.1% impurity). The method is suitable for the determination of phytotoxic substances and such which may influence formulation properties, for example pH-value, colour, odour, solubility or stability.  相似文献   

3.
化学发光二维两点检测微流控芯片系统设计集成了一种可用于分离检测氨基酸、多肽和蛋白质等复杂样品的化学发光二维两点检测微流控芯片系统.该系统采用双检测器同时检测第一维和第二维的分离峰信息,可获得样品的二维分离谱图,满足了对多种复杂结构微流控芯片分离特性进行研究的要求.  相似文献   

4.
This paper presents a model that describes how liquid flow fills micro-fluidic components and networks. As an alternative to computational fluid dynamic (CFD) simulations, we use a constrained energy minimization approach. This approach is based on two assumptions that hold in many micro-fluidic devices: (i) The length scales are small, and we consider slow filling rates, hence fluid momentum and viscous terms are small compared to surface tension forces, consequently the liquid/gas interfaces can be viewed as a succession of quasi-steady equilibrium configurations. (ii) Any equilibrium configuration corresponds to a surface tension energy minima which is constrained by the device shape and the volume of liquid in the device. The model is developed for planar micro-fluidic devices, is based on a fundamental physical principle, and shows accurate agreement with experimental data. It takes us only a few minutes to evaluate the model for a planar component of any shape using the Surface Evolver software, and this is significantly less then the computer run time required for CFD simulations. Moreover, once a library of component models has been created (which takes less than an hour of computer time) it then takes only seconds to simulate different network architectures with thousands of components. This fast "reconfigure the network and simulate in seconds" capability is essential for the design of truly complex networks that will enable the next generation of passive, micro-fluidic, lab-on-a-chip systems.  相似文献   

5.
构建了一种新型香豆素-萘酰亚胺荧光/电子顺磁共振双功能探针CNNOH,并结合荧光光谱、电子顺磁共振(EPR)波谱和紫外-可见吸收光谱对其性能进行了研究.结果表明,该探针可结合荧光光谱的灵敏性和EPR波谱的特异性进行次氯酸的检测;由于香豆素与萘酰亚胺之间存在荧光共振能量转移(FRET)效应,探针分子具有较大的Stokes位移(135 nm),可有效避免由激发光导致的杂散光对检测的干扰.该双功能探针具有检出限低(0.214μmol/L)、反应速度快(~10 s)、检测范围宽(0~5 mmol/L)、选择性好及在生理条件下稳定的特点,预期在活体细胞检测方面有良好的应用前景.  相似文献   

6.
Ammonia-nitrogen feedstock streams, free of oxygen containing impurities, are essential reagents for fabricating low oxygen contaminated nitride films. An analytical method is described for determining part per billion levels of oxygen containing impurities, which are converted to nitric oxide (NO) through reaction with microwave discharge produced active nitrogen. Quantitative determinations are then based on detecting the resulting chemiluminescence of NO at characteristic wavelengths. This metastable transfer spectrometric method (MTES) provides direct measurements of oxygen impurities over the 14 to 500 ppb region and has dynamic range extending to 200 ppm. The method, unparalleled in its measurement sensitivity for oxygen impurities in flowing nitrogen gas streams, is calibrated with an NBS standard and applied to the determination of the purification efficiency of an on-line resin system for removal of O2, CO and NO from ammonia-nitrogen mixtures. Gaseous streams, doped deliberately in the 0.2 to 100 ppm level with either O2, CO or NO following purification were found to contain less than 10 ppb of the residual impurity. A commercially available 1% ammonia in nitrogen semiconductor grade reagent (99.999%) is shown by MTES to be contaminated with 470 ppb of oxygen impurities.  相似文献   

7.
Ibuprofen arginate is a rapidly absorbed salt designed to promote more rapid onset of analgesia than commercially available forms of ibuprofen. Ibuprofen and arginine have very different polarities and this becomes in a chromatographic problem, further complicated with the determination of related compounds, which is necessary in stability assays of the pharmaceutical forms. The common solution is the employment of two separate methods, but this is time consuming. A LC method has been developed to determinate both compounds and related impurities in one run. Ibuprofen, arginine and three ibuprofen related impurities (B, E and J) have been baseline separated with isocratic conditions at pH 3.0 and run time under 20 min by employing a tandem combination of two different stationary phases: first a ZORBAX SB-C18 column from Agilent (250 mm x 4.6 mm and 5 microm) and downstream a SUPELCOSIL LC-NH2 column from Supelco (150 mm x 4.6 mm and 3 microm). The octadecyldiisobutylsilane column provides the separation of ibuprofen and its impurities by a hydrophobic mechanism, whereas aminopropyl column offers selective retention of arginine by dipolar interaction mechanism. Method has been successfully validated following ICH guidelines and it has been demonstrated to be reliable for arginine, ibuprofen and related impurities determination in sachets of two different dosages as pharmaceutical forms. Moreover, stress test has proved the selectivity of the method for degradation products, such as those that can emerge throughout long-term stability assays.  相似文献   

8.
Artificial cilia for active micro-fluidic mixing   总被引:2,自引:0,他引:2  
In lab-on-chip devices, on which complete (bio-)chemical analysis laboratories are miniaturized and integrated, it is essential to manipulate fluids in sub-millimetre channels and sub-microlitre chambers. A special challenge in these small micro-fluidic systems is to create good mixing flows, since it is almost impossible to generate turbulence. We propose an active micro-fluidic mixing concept inspired by nature, namely by micro-organisms that swim through a liquid by oscillating microscopic hairs, cilia, that cover their surface. We have fabricated artificial cilia consisting of electro-statically actuated polymer structures, and have integrated these in a micro-fluidic channel. Flow visualization experiments show that the cilia can generate substantial fluid velocities, up to 0.6 mm s(-1). In addition, very efficient mixing is obtained using specially designed geometrical cilia configurations in a micro-channel. Since the artificial cilia can be actively controlled using electrical signals, they have exciting applications in micro-fluidic devices.  相似文献   

9.
The capability of the helium ionization detector (HID) to operate in connection with capillary columns for trace gas analyses has been evaluated. Two different capillary columns were considered: a PLOT fused silica column with molecular sleve and a thick film WCOT glass column with PS-255. The determination of trace impurities in gases can be achieved with evident advantages over classical adsorption columns, even using a split injection system. Direct on-column injections also have been investigated with promising results.  相似文献   

10.
We explore the design and operation of an optical-tweezers electrophoresis apparatus to resolve polymer adsorption dynamics onto a single micro-sphere in a micro-fluidic environment. Our model system represents a broader class of micro-fluidic electrophoresis experiments for biosensing and fundamental colloid and surface science diagnostics. We track the adsorption of 100 kDa poly(ethylene oxide) homopolymer onto a colloidal silica sphere that is optically trapped in a crossed parallel-plate micro-channel. The adsorption dynamics are probed on the ~1 μm particle length scale with ~1 s temporal resolution. Because the particle electrophoretic mobility and channel electro-osmotic flow are exquisitely sensitive to the polymer layer hydrodynamic thickness, particle dynamics can be complicated by polymer adsorption onto the micro-channel walls. Nevertheless, using experiments and a theoretical model of electro-osmotic flow in channels with non-uniform wall ζ-potentials, we show that such influences can be mitigated by adopting a symmetrical flow configuration. The equilibrium hydrodynamic layer thickness of 100 kDa poly(ethylene oxide) on colloidal silica is ~10 nm at polymer concentrations ?10 ppm (weight percent), with the dynamics reflecting polymer solution concentration, flow rate, and polydispersity.  相似文献   

11.
Terrestrial solar ultraviolet (UV) radiation has significant implications for human health and increasing levels are a key concern regarding the impact of climate change. Monitoring solar UV radiation at the earth's surface is therefore of increasing importance. A new prototype portable CCD (charge‐coupled device) spectrometer‐based system has been developed that monitors UV radiation (280–400 nm) levels at the earth's surface. It has the ability to deliver this information to the public in real time. Since the instrument can operate autonomously, it is called the Autonomous Portable Solar Ultraviolet Spectroradiometer (APSUS). This instrument incorporates an Ocean Optics QE65000 spectrometer which is contained within a robust environmental housing. The APSUS system can gather reliable solar UV spectral data from approximately April to October inclusive (depending on ambient temperature) in the UK. In this study the new APSUS unit and APSUS system are presented. Example solar UV spectra and diurnal UV Index values as measured by the APSUS system in London and Weymouth in the UK in summer 2012 are shown.  相似文献   

12.
13.
Ultra-sharp nano-probes and customized atomic force microscopy (AFM) have previously been developed in our laboratory for in situ sub-cellular probing of electrochemical phenomena in living plant cells during their photosynthesis. However, this AFM-based electrochemical probing still has numerous engineering challenges such as immobilization of the live cells, compatibility of the immobilization procedure with AFM manipulation of the probe, maintenance of biological activity of the cells for an extended time while performing the measurements, and minimization of electrochemical noise. Thus, we have developed an open micro-fluidic channel system (OMFC) in which individual cells can be immobilized in micro-traps by capillary flow. This system affords easy AFM access and allows for maintenance of the cells in a well-defined chemical environment, which sustains their biological activity. The use of micro-channels for making the electrochemical measurements significantly reduces parasitic electrical capacitances and allows for current detection in the sub-pico-ampere range at high signal bandwidths. The OMFC was further studied using simulation packages for optimal design conditions. This system was successfully used to measure light-dependent oxidation currents of a few pico-amperes from the green alga Chlamydomonas reinhardtii.  相似文献   

14.
This review critically summarises recent novel and advanced achievements in the application of monolithic materials and related porous polymer gels in micro-fluidic devices appearing within the literature over the period of the last 5 years (2005-2010). The range of monolithic materials has developed rapidly over the past decade, with a diverse and highly versatile class of materials now available, with each exhibiting distinct porosities, pore sizes, and a wide variety of surface functionalities. A major advantage of these materials is their ease of preparation in micro-fluidic channels by in situ polymerisation, leading to monolithic materials being increasingly utilised for a larger variety of purposes in micro-fluidic platforms. Applications of porous polymer monoliths, silica-based monoliths and related homogeneous porous polymer gels in the preparation of separation columns, ion-permeable membranes, preconcentrators, extractors, electrospray emitters, micro-valves, electrokinetic pumps, micro-reactors and micro-mixers in micro-fluidic devices are discussed herein. Procedures used in the preparation of monolithic materials in micro-channels, as well as some practical aspects of the micro-fluidic chip fabrication are addressed. Recent analytical/bioanalytical and catalytic applications of the final micro-fluidic devices incorporating monolithic materials are also reviewed.  相似文献   

15.
Iminium salts can provide high selectivity and high efficiency when used as organocatalysts for asymmetric epoxidation. For this purpose, they are normally used in conjunction with Oxone as the stoichiometric oxidant. Oxone, however, has limited stability, is insoluble in most organic solvents, is atom-inefficient, and produces considerable inorganic residue as the by-product of oxidation. In this paper we report for the first time the development of a reaction system driven by sodium hypochlorite as the stoichiometric oxidant.  相似文献   

16.
A planar lipid bilayer which is widely used for the electrophysiological study of membrane proteins in laboratories is reconstituted using a micro-fluidic system, in a manner that is suitable for automated processing. We fabricated micro-channels on both sides of the substrate, which are connected through a 100-200 microm aperture, and showed that the bilayer can be formed at the aperture by flowing the lipid solution and buffer, alternately. Parylene coating is found to be suitable for both bilayer formation and electric noise reduction. Future applications include a high-sensitivity ion sensor chip and a high-throughput drug screening device.  相似文献   

17.
Caustic regeneration procedures are often used in chromatographic purification processes of peptides and proteins to remove irreversibly bound impurities from the stationary phase. Silica-based materials are the most commonly used materials in reversed phase chromatography of peptides. Their limited chemical stability at high pH can be, however, problematic when high pH column regeneration (i.e. cleaning in place) is required. The effect of cleaning in place on the surface chemistry of the stationary phase has been investigated using the Tanaka test. It has been shown that the high pH treatment does not significantly affect the hydrophobicity of the material, but it strongly increases its silanol activity. A representative peptide purification process has been used to investigate the impact of cleaning in place on the separation performance. It has been shown that the caustic regeneration increases the peptide retention at high pH (pH 6.5), due to the interactions between the peptide and the negatively charged silanol groups. These unwanted interactions reduce the separation performances by decreasing the selectivity between the late eluting impurities and the main peptide. However, it has been shown that the effect of the silanol groups on the peptide adsorption and on the separation performance can be minimized by carrying out the purification process at low pH (pH ∼ 2). In this case, the silanol groups are protonated and their electrostatic interactions with the positively charged analyte (i.e. peptides) are suppressed. In these conditions, the peptide adsorption and the impurity selectivity is not changing upon high pH column regeneration and the separation performance is not affected.  相似文献   

18.
Purification of pyridine by zone fractional crystallization reduces the concentration of prewave-producing contaminant below polarographic detection limits, i.e., 0.01 mM. A qualitative test based on the stability of the free radical diphenylpicrylhydrazyl has shown the method to be capable of reducing the concentration of proton-releasing impurities. Water is also removed. Investigation of the effect of the contaminants in normal reagent-grade pyridine on the electrocapillary curves and polarograms of pyridine solutions containing lithium perchlorate and tetraethylammonium perchlorate as background electrolytes in the presence and absence of oxygen, has indicated that the impurities are capable of changing the mechanism for the electrochemical reduction of oxygen in pyridine.  相似文献   

19.
Hydrodynamic and colloidal interactions are explored in concentrated, charge-stabilized colloidal dispersions by measuring the dependence of rheology (e.g., low and high-shear viscosity, high-frequency viscosity, and modulus) and self-diffusivity on salt content, particle size, and concentration. Model, sulfonated polystyrene lactices of varying diameter are prepared and investigated by shear rheology, high-frequency torsional resonance, electrophoresis, titration, and dynamic light scattering. The high-frequency and high-shear viscosity both are dominated by hydrodynamic interactions, but are shown not to be identical, due to the microstructure distortion resulting from high shear rates. The short-time self-diffusion is also shown to be insensitive to direct particle interactions, but has a different concentration dependence than the high-frequency viscosity, further illustrating a predicted violation of a generalized Stokes-Einstein relationship for these properties. The apparent colloidal surface charge is extracted from the high-frequency elastic modulus measurements on concentrated dispersions. The surface charge is in good agreement with results from critical coagulation concentration measurements and perturbation theories, but disagrees with electrophoretic mobility experiments. This indicates that the effective surface charge determined by torsional high-frequency measurements is a more reliable predicter of the salt stability of charge-stabilized dispersions, in comparison to zeta-potentials determined from electrophoretic mobilities. Further, we demonstrate by direct comparison that measurements of the apparent plateau modulus by rotational rheometry underestimate the true, high-frequency modulus and provide unreliable estimates for the surface charge. Copyright 2000 Academic Press.  相似文献   

20.
孙春艳  纪颖鹤  秦昆明  高珣  赵龙山 《色谱》2019,37(12):1297-1304
建立了一种同时测定吉非替尼中4种基因毒性杂质3-氯-4-氟苯胺、3,4-二氟苯胺、3-氟-4-氯苯胺和3,4-二氯苯胺的高效液相色谱-串联质谱(HPLC-MS/MS)方法。用Inertsil ODS-3柱(100 mm×3.0 mm,3μm)为色谱柱,以0.1%(体积分数,下同)甲酸水溶液-0.1%甲酸乙腈溶液为流动相,在电喷雾正离子模式下进行测定。该方法在特异性、线性、精密度、准确性、稳定性和耐用性方面得到了验证。4种基因毒性杂质在0.6~96.0μg/L范围内与峰面积呈良好线性关系。检测限和定量限分别为0.2~2.0μg/L和0.6~6.0μg/L。所有杂质的回收率为91.0%~98.5%。检测后,在批号16052301和R16052501-1样品中仅检测到3-氯-4-氟苯胺,但低于杂质限度(6 mg/L)。该方法简便可靠,可用于吉非替尼中4种基因毒性杂质的测定,并为质量控制提供参考。  相似文献   