首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
The use of stable isotope labelled glucose provides insight into glucose metabolism. The 13C‐isotopic enrichment of glucose is usually measured by gas chromatography/mass spectrometry (GC/MS) or gas chromatography/combustion/isotope ratio mass spectrometry (GC/C/IRMS). However, in both techniques the samples must be derivatized prior to analysis, which makes sample preparation more labour‐intensive and increases the uncertainty of the measured isotopic composition. A novel method for the determination of isotopic enrichment of glucose in human plasma using liquid chromatography/isotope ratio mass spectrometry (LC/IRMS) has been developed. Using this technique, for which hardly any sample preparation is needed, we showed that both the enrichment and the concentration could be measured with very high precision using only 20 µL of plasma. In addition, a comparison with GC/MS and GC/IRMS showed that the best performance was achieved with the LC/IRMS method making it the method of choice for the measurement of 13C‐isotopic enrichment in plasma samples. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

2.
The incorporation of stable isotopes improves the assessment of glucose metabolism and, with some researchers using two tracers, (2)H-glucose assessed by gas chromatography/mass spectrometry (GC/MS) and (13)C-glucose by gas chromatography/combustion/isotope ratio mass spectrometry (GC/C/IRMS), a common derivative for both is advantageous. The most commonly used derivatives for GC/MS are inappropriate for GC/C/IRMS as additional functional groups dilute the label. We therefore considered the suitability of six derivatives for both GC/MS and GC/C/IRMS. Glucose alkylboronates were prepared by adding the appropriate alkylboronic acid (butyl- or methylboronic acid) in pyridine to desiccated glucose. The derivatisation was completed by reacting this with either (a) acetic anhydride or trifluoroacetic anhydride (acetate derivatives) or (b) bis(trimethylsilyl)trifluoroacetamide BSTFA (TMS derivatives). All six derivatives were assessed using GC/MS and (13)C GC/C/IRMS.Neither TMS derivative exhibited any signal intensity in the molecular ion, although a M-15 ion showed good agreement between experimental and theoretical data and, whilst still low in intensity, could be suitable for isotope work. Similarly, none of the acetate derivatives showed any intensity at the molecular ion although three key fragmentation series were identified. The most attractive sequence, initiated by the loss of 1,2 cyclic boronate, resulted in the main fragment ion of interest, m/z 240, corresponding to the fluorinated methylboronate derivate. Minimal carbon and hydrogen atoms are added to this derivative making it an excellent choice for stable isotope work, while proving suitable for analysis by both GC/MS and GC/C/IRMS.  相似文献   

3.
Precise measurement of low enrichment of stable isotope labeled amino‐acid tracers in tissue samples is a prerequisite in measuring tissue protein synthesis rates. The challenge of this analysis is augmented when small sample size is a critical factor. Muscle samples from human participants following an 8 h intravenous infusion of L‐[ring‐13C6]phenylalanine and a bolus dose of L‐[ring‐13C6]phenylalanine in a mouse were utilized. Liquid chromatography tandem mass spectrometry (LC/MS/MS), gas chromatography (GC) MS/MS and GC/MS were compared to the GC‐combustion‐isotope ratio MS (GC/C/IRMS), to measure mixed muscle protein enrichment of [ring‐13C6]phenylalanine enrichment. The sample isotope enrichment ranged from 0.0091 to 0.1312 molar percent excess. As compared with GC/C/IRMS, LC/MS/MS, GC/MS/MS and GC/MS showed coefficients of determination of R2 = 0.9962 and R2 = 0.9942, and 0.9217 respectively. However, the precision of measurements (coefficients of variation) for intra‐assay are 13.0%, 1.7%, 6.3% and 13.5% and for inter‐assay are 9.2%, 3.2%, 10.2% and 25% for GC/C/IRMS, LC/MS/MS, GC/MS/MS and GC/MS, respectively. The muscle sample sizes required to obtain these results were 8 µg, 0.8 µg, 3 µg and 3 µg for GC/C/IRMS, LC/MS/MS, GC/MS/MS and GC/MS, respectively. We conclude that LC/MS/MS is optimally suited for precise measurements of L‐[ring‐13C6]phenylalanine tracer enrichment in low abundance and in small quantity samples. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

4.
Under most physiological conditions, glucose, or carbohydrate (CHO), homeostasis is tightly regulated. In order to mechanistically appraise the origin of circulating glucose (e.g. via either gluconeogenesis, glycogenolysis or oral glucose intake), and its regulation and oxidation, the use of stable isotope tracers is now a well-accepted analytical technique. Methodologically, liquid chromatography coupled to isotope ratio mass spectrometry (LC/IRMS) can replace gas chromatography coupled to combustion-isotope ratio mass spectrometry (GC/C/IRMS) for carrying out compound-specific (13)C isotopic analysis. The LC/IRMS approach is well suited for studying glucose metabolism, since the plasma glucose concentration is relatively high and the glucose can readily undergo chromatography in an aqueous mobile phase. Herewith, we report two main methodological approaches in a single instrument: (1) the ability to measure the isotopic enrichment of plasma glucose to assess the efficacy of CHO-based treatment (cocoa-enriched) during cycling exercise with healthy subjects, and (2) the capacity to carry out bulk isotopic analysis of labeled solutions, which is generally performed with an elemental analyzer coupled to IRMS. For plasma samples measured by LC/IRMS the data show a isotopic precision SD(δ(13)C) and SD(APE) of 0.7 ‰ and 0.001, respectively, with δ(13)C and APE values of -25.48 ‰ and 0.06, respectively, being generated before and after tracer administration. For bulk isotopic measurements, the data show that the presence of organic compounds in the blank slightly affects the δ(13)C values. Despite some analytical limitations, we clearly demonstrate the usefulness of the LC/IRMS especially when (13)C-glucose is required during whole-body human nutritional studies.  相似文献   

5.
A reference method to accurately define kinetics in response to the ingestion of glucose in terms of total, exogenous and endogenous glucose is to use stable‐isotope‐labelled compounds such as 2H and 13C glucose followed by gas chromatography/mass spectrometry (GC/MS) and gas chromatography/combustion/isotope ratio mass spectrometry (GC/C/IRMS) analysis. The use of the usual pentaacetyl (5Ac) derivative generates difficulties in obtaining accurate and reproducible results due to the two chromatographic peaks for the syn and anti isomers, and to the isotopic effect occurring during acetylation. Therefore, the pentaacetylaldononitrile derivative (Aldo) was validated for both isotopes, and compared with the 5Ac derivative. A correction factor including carbon atom dilution (stoichiometric equation) and the kinetic isotopic effect (KIE) was determined. Analytical validation results for the 2H GC/MS and 13C GC/C/IRMS measurements produced acceptable results with both derivatives. When 2H enrichments of plasma samples were ≤1 mol % excess (MPE), the repeatability (RSDAldo Intra assay and Intra day <0.94%, RSD5Ac Intra assay and Intra day <3.29%), accuracy (Aldo <3.4%, 5Ac <29.0%), and stability of the derivatized samples were significantly better when the Aldo derivatives of the plasma samples were used (p < 0.05). When the glucose kinetics were assessed in nine human subjects, after glucose ingestion, the plasma glucose 2H enrichments were identical with both derivatives, whereas the 13C enrichments needed a correction factor to fit together. Due to KIE variation, this correction factor was not constant and had to be calculated for each batch of analyses, to obtain satisfactory results. Mean quantities of exogenous glucose exhibit marked difference (20.9 ± 1.3g (5Ac) vs. 26.7 ± 2.5g (Aldo)) when calculated with stoichiometric correction, but fit perfectly when calculated after application of the correction factor (22.1 ± 1.3g (5Ac) vs. 22.9 ± 1.9g (Aldo)). Finally, the pentaacetylaldononitrile derivative, used here in GC/C/IRMS for the first time, enables measurement of 2H and 13C enrichments in plasma glucose with a single sample preparation. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

6.
Volatile fatty acids (VFAs) are produced in the human colon by the bacterial breakdown of carbohydrates that escape digestion and absorption in the small intestine. They have important local and systemic effects on gastrointestinal and nutritional functions. Measuring their production is difficult because of inaccessibility of sampling sites and low circulating concentrations. Stable isotope tracer techniques are a way to measure VFA production but require measurement of isotope dilution in blood and other biological fluids. We have developed a streamlined and robust method to measure the concentration and enrichment of [(2)H]-labelled VFAs by gas chromatography/mass spectrometry (GC/MS) and [(13)C]-labelled VFAs by gas chromatography/combustion/isotope ratio mass spectrometry (GC/C/IRMS). Both types of analysis were carried out on the same samples allowing multiple tracer studies to be conducted. Good accuracy and repeatability were found for GC/MS analysis of [(2)H]-labelled VFAs. Careful handling of the background contribution, especially acetate, allowed quantitation of concentration and enrichment within the analysis. GC/C/IRMS analysis of [(13)C] VFAs was also achieved with good accuracy and repeatability. This methodology was used to determine whole-body acetate production in two subjects using multiple tracers ([(2)H(3)]- and [1-(13)C]acetate) and blood and urine sampling. Whole-body acetate flux was similar when measured either with [(2)H(3)]- or [1-(13)C]acetate, and when flux was determined from plasma or urine tracer enrichment. This new method will permit rapid and accurate measurement of VFA flux using [(2)H]- and/or [(13)C]-labelled VFAs as tracers. Measurements of the contribution of colonic VFA production to whole-body VFA flux are now possible.  相似文献   

7.
Compound-specific stable isotope analysis (CSIA) using gas chromatography-isotope ratio mass spectrometry (GC/IRMS) has developed into a mature analytical method in many application areas over the last decade. This is in particular true for carbon isotope analysis, whereas measurements of the other elements amenable to CSIA (hydrogen, nitrogen, oxygen) are much less routine. In environmental sciences, successful applications to date include (i) the allocation of contaminant sources on a local, regional, and global scale, (ii) the identification and quantification of (bio)transformation reactions on scales ranging from batch experiments to contaminated field sites, and (iii) the characterization of elementary reaction mechanisms that govern product formation. These three application areas are discussed in detail. The investigated spectrum of compounds comprises mainly n-alkanes, monoaromatics such as benzene and toluene, methyl tert-butyl ether (MTBE), polycyclic aromatic hydrocarbons (PAHs), and chlorinated hydrocarbons such as tetrachloromethane, trichloroethylene, and polychlorinated biphenyls (PCBs). Future research directions are primarily set by the state of the art in analytical instrumentation and method development. Approaches to utilize HPLC separation in CSIA, the enhancement of sensitivity of CSIA to allow field investigations in the µg L–1 range, and the development of methods for CSIA of other elements are reviewed. Furthermore, an alternative scheme to evaluate isotope data is outlined that would enable estimates of position-specific kinetic isotope effects and, thus, allow one to extract mechanistic chemical and biochemical information.Abbreviations BTEX benzene, toluene, ethylbenzene, xylenes - MTBE methyl tert-butyl ether - PAHs polycyclic aromatic hydrocarbons - VOCs volatile compounds - PCBs polychlorinated biphenyls - CSIA compound-specific (stable) isotope (ratio) analysis - GC-IRMS, GC/IRMS or GCIRMS gas chromatography-isotope ratio mass spectrometry - GC-C-IRMS, GC/C/IRMS or GCC-IRMS gas chromatography-combustion-isotope ratio mass spectrometry - irmGC/MS isotope ratio monitoring gas chromatograph-mass spectrometry - GC/P/IRMS gas chromatography-pyrolysis-isotope ratio mass spectrometry (used for D/H) - KIE kinetic isotope effect - PSIA position-specific isotope analysis (for intramolecular isotope distribution) - SNIF-NMR site-specific natural isotopic fractionation by nuclear magnetic resonance spectroscopy  相似文献   

8.
We have investigated a novel application of gas chromatography/combustion/isotope ratio mass spectrometry (GC/C/IRMS) for the quantitative analysis of the isoflavones in food matrices. Previous methods have been hampered by the lack of analytical standards to introduce early enough in the extraction procedure to allow compensations for losses at all stages of the procedure. In this work we have produced standard materials that can be added at the initial extraction, by intrinsically labelling soya plants by growing them in an atmosphere enriched in the stable isotope of carbon in CO(2). On analysis these plants were shown to contain phytoestrogens at a high (up to 20%) level of enrichment. The dried plant material has been used to estimate the isoflavone concentrations of a set of spiked flours. For daidzein the methodology was shown to produce results comparable to those achieved by GC/MS techniques. The method was less successful for genistein, possibly due to the greater fragility of this compound under the conditions required for the analysis.  相似文献   

9.
Pulmonary surfactant is a complex mixture of phospholipids and proteins which lowers surface tension and maintains alveolar expansion at end expiration. Developmental and genetic disruption of pulmonary surfactant metabolism leads to respiratory distress in newborns. Stable isotope labeling of metabolic precursors of disaturated phospholipids, the most abundant and specific component of pulmonary surfactant, permits the measurement of the kinetics of surfactant metabolism in vivo. We measured [U-(13)C(6)]glucose incorporation into palmitic acid derived from disaturated surfactant phospholipids. A 24 h infusion of [U-(13)C(6)]glucose (140 mg kg(-1)) was administered to a premature infant who required mechanical ventilation for respiratory distress syndrome; tracheal aspirate samples were obtained at the start of the infusion and at regular intervals for the next 70 h. Each tracheal aspirate sample was incubated with osmium tetroxide to isolate disaturated surfactant phospholipids. Methyl esters of the fatty acids in the disaturated phospholipids were prepared and the enrichment of [(13)C]methyl palmitate was measured by gas chromatography/mass spectrometry (GC/MS) and gas chromatography/combination/isotope ratio mass spectrometry (GC/C/IRMS). Mass isotopomer distribution analysis (MIDA) was used to calculate the fractional synthetic rate (FSR) of palmitate synthesized from acetate. With both GC/MS and GC/C/IRMS, palmitate (13)C enrichment was first detected 12.3 h after the start of the tracer infusion. The enrichment increased in a linear fashion, reached a peak at 47 h and remained constant in the remainder of the samples. The FSR of palmitate from acetate was 5.2% per day. Stable isotope techniques and MIDA will provide insights into the kinetics of surfactant metabolism in newborns with respiratory dysfunction.  相似文献   

10.
The depletion of glutathione (GSH) reported in very-low-birth-weight infants is implicated in several pathologies, especially if deficiency occurs during foetal development. The cause of this depletion is suggested to be modification of GSH turnover. To probe the role of GSH, a reliable non-invasive method adapted to very-low-birth-weight infants is required. In this paper, we report the preparation of the N,S-ethoxycarbonyl methyl ester derivatives of GSH and glycine and their application to the measurement of (13)C/(12)C ratios at natural abundance in erythrocyte samples by gas chromatography/combustion/isotope ratio mass spectrometry (GC/C/IRMS). The technique allowed the determination of (13)C/(12)C ratios at natural abundance with a precision <3% and within-day and between-day variabilities both <4%. The method is able to determine accurately low (13)C-enrichments in GSH (0.00241 to 0.00753 Atom Percent Excess) in erythrocyte extracts following incubation with (13)C-glycine at low specific enrichment (approx. 1.5 atom %). Excellent agreement was obtained between the calculated GSH fractional synthesis rate (FSR) in human adult blood (approx. 300% day(-1)) using the low-enrichment (13)C-glycine/GC/C/IRMS protocol and that using highly enriched (13)C-glycine (99 atom %)/GC/MS with the same derivative. The GC/C/IRMS method was shown to be suitable to measure the in vitro GSH FSR (200-660% day(-1)) in human venous and arterial blood from the umbilical cord. This approach provides a good tool for studying the turnover of GSH in vitro in infants, allowing both the use of minimal amounts of tracer and negligible perturbation of endogenous precursor pools.  相似文献   

11.
Soft‐ionization methods are currently at the forefront of developing novel methods for analysing degraded archaeological organic residues. Here, we present little‐used soft ionization method of matrix assisted laser desorption/ionization‐Fourier transform‐ion cyclotron resonance‐mass spectrometry (MALDI‐FT‐ICR‐MS) for the identification of archaeological lipid residues. It is a high‐resolution and sensitive method with low limits of detection capable of identifying lipid compounds in small concentrations, thus providing a highly potential new technique for the analysis of degraded lipid components. A thorough methodology development for analysing cooked and degraded food remains from ceramic vessels was carried out, and the most efficient sample preparation protocol is described. The identified components, also controlled by independent parallel analysis by gas chromatography‐mass spectrometry (GC‐MS) and gas chromatography‐combustion‐isotope ratio mass spectrometry (GC‐C‐IRMS), demonstrate its capability of identifying very different food residues including dairy, adipose fats as well as lipids of aquatic origin. The results obtained from experimentally cooked and original archaeological samples prove the suitability of MALDI‐FT‐ICR‐MS for analysing archaeological organic residues. Sample preparation protocol and identification of compounds provide future reference for analysing various aged and degraded lipid residues in different organic and mineral matrices.  相似文献   

12.
In the present study, different MS methods for the determination of human muscle protein fractional synthesis rate (FSR) using [ring‐13C6]phenylalanine as a tracer were evaluated. Because the turnover rate of human skeletal muscle is slow, only minute quantities of the stable isotopically labeled amino acid will be incorporated within the few hours of a typical laboratory experiment. GC combustion isotope ratio MS (GC‐C‐IRMS) has thus far been considered the ‘gold’ standard for the precise measurements of these low enrichment levels. However, advances in liquid chromatography‐tandem MS (LC‐MS/MS) and GC‐tandem MS (GC‐MS/MS) have made these techniques an option for human muscle FSR measurements. Human muscle biopsies were freeze dried, cleaned, and hydrolyzed, and the amino acids derivatized using either N‐acetyl‐n‐propyl, phenylisothiocyanate, or N‐methyl‐N‐(tert‐butyldimethylsilyl)trifluoroacetamide (MTBSTFA) for GC‐C‐IRMS, LC‐MS/MS, and GC‐MS/MS analysis, respectively. A second derivative, heptafluorobutyric acid (HFBA), was also used for GC‐MS/MS analysis as an alternative for MTBSTFA. The machine reproducibility or the coefficients of variation for delta tracer‐tracee‐ratio measurements (delta tracer‐tracee‐ratio values around 0.0002) were 2.6%, 4.1%, and 10.9% for GC‐C‐IRMS, LC‐MS/MS, and GC‐MS/MS (MTBSTFA), respectively. FSR determined with LC‐MS/MS compared well with GC‐C‐IRMS and so did the GC‐MS/MS when using the HFBA derivative (linear fit Y = 1.08 ± 0.10, X + 0.0049 ± 0.0061, r = 0.89 ± 0.01, P < 0.0001). In conclusion, (1) IRMS still offers the most precise measurement of human muscle FSR, (2) LC‐MS/MS comes quite close and is a good alternative when tissue quantities are too small for GC‐C‐IRMS, and (3) If GC‐MS/MS is to be used, then the HFBA derivative should be used instead of MTBSTFA, which gave unacceptably high variability. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

13.
To study carbohydrate digestion and glucose absorption, time-dependent (13)C enrichment in plasma glucose is measured after oral administration of naturally occurring (13)C-enriched carbohydrates. The isotope enrichment of the administered carbohydrate is low (APE <0.1%) and plasma (13)C glucose measurements are routinely determined with gas chromatography/combustion/isotope ratio mass spectrometry (GC/C/IRMS) or liquid chromatography/combustion/isotope ratio mass spectrometry (LC/C/IRMS). In this study, plasma glucose was converted into CO(2) by an in-tube reaction with yeast permitting direct measurement of (13)CO(2) in the headspace. Saccharomyces cerevisiae incubated under anaerobic conditions was able to convert sufficient glucose into CO(2) to produce a consistent CO(2) peak in IRMS with little variation in peak area and precise delta(13)C(PDB) values for corn glucose: -11.40 +/- 0.16 per thousand, potato glucose: -25.17 +/- 0.13 per thousand, and plasma glucose: -26.29 +/- 0.05 per thousand. The measurement showed high linearity (R(2) = 0.999) and selectivity and was not affected by the glucose concentration in the tested range of 5-15 mM. Comparison with GC/C/IRMS showed a good correlation of enrichment data: R(2) > 0.98 for both sources of glucose and plasma samples. Commercially available, instant dried baker's yeast was qualitatively and quantitatively comparable with freshly prepared yeast: R(2) > 0.96, slope 1.03 and 1.08 for glucose solutions and plasma, respectively. Thus, yeast conversion of plasma glucose into CO(2) and (13)C measurement applying a breath (13)CO(2) analyzer is an inexpensive, simple and equally accurate alternative to the more expensive and laborious GC/C/IRMS and LC/C/IRMS measurements.  相似文献   

14.
Compound-specific stable carbon isotope analysis of amino acids by gas chromatography/combustion/isotope ratio mass spectrometry (GC/C/IRMS) is a highly selective and sensitive method for probing the biosynthetic/diagenetic pathways, pool size and turnover rates of proteins, previously intractable to bulk isotope analyses. However, amino acids are polyfunctional, non-volatile compounds which require derivatisation prior to GC analysis. While a wide range of derivatives exist for the GC analysis of amino acids only a handful have been utilised for their GC/C/IRMS analysis. Significantly, none of those derivatives currently employed appear completely satisfactory and a thorough assessment of their relative utility is lacking. Seven derivatives (three previously reported and four novel) for obtaining delta(13)C values of amino acids via GC/C/IRMS analysis were compared. More specifically, standard mixtures of 15 protein amino acids were converted into N-acetylmethyl (NACME) esters, N-acetyl n-propyl (NANP) esters, N-acetyl i-propyl (NAIP) esters, N-trifluoroacetyl-i-propyl (TFA-IP) esters, N-pivaloyl methyl (NPME) esters, N-pivaloyl n-propyl (NPNP) esters and N-pivaloyl i-propyl (NPIP) esters. Each derivative was assessed with respect to its applicability to carbon isotope determinations of all the common alpha-amino acids, reaction yield, chromatographic resolution, stability, analyte-to-derivative carbon ratio, kinetic isotope effects and errors associated with their carbon isotope determinations. The NACME derivative was concluded to be the preferred derivative mainly due to the highest analyte-to-derivative carbon ratio being achieved, resulting in the lowest analytical errors for amino acid delta(13)C value determinations, ranging from +/-0.6 per thousand for phenylalanine, leucine and isoleucine to +/-1.1 per thousand for serine and glycine.  相似文献   

15.
A new analytical method is described for the determination of the physiological concentration and low-level enrichment of (13)C-short-chain volatile organic acids (SCVAs) (e.g. (13)C-acetate and (13)C-butyrate) in human plasma. This two-step method involves solid-phase microextraction (SPME) coupled to gas chromatography/combustion/isotope ratio mass spectrometry (GC/C/IRMS) without any organic solvents or derivatizing agents. Two SCVA extraction methods were compared using a carboxen/polydimethylsiloxane fiber: headspace sampling (HS) and liquid sampling (LS) SPME. The influences of extraction temperature and time were tested to optimize the adsorption of SCVAs onto the fiber. The comparison of the peak area responses of the acids in the two adsorption methods showed better sensitivity in the human physiological concentration range in the LS mode than in the HS mode.The accuracy of isotopic enrichment measurement was determined using plasma spiked with (13)C-acetate and (13)C-butyrate solution from 0 to 1 mol percent excess (MPE). The linearity and repeatability (RSD < 5%) were measured in LS mode. Plasma SCVA concentrations were also determined relative to 3-methylvalerate (internal standard). Linearity and repeatability were observed from 0 to 400 microM for acetate, from 0 to 20 microM for propionate, and from 0 to 10 microM for butyrate. This method was also used to determine plasma acetate production obtained from lactulose (an undigestible disaccharide) fermentation in one healthy volunteer over 3 h. The acetate concentration increased twofold, 2 h after oral lactulose intake. These results are in agreement with the data obtained by GC/MS in healthy volunteers and obese adults following a lactulose intake by using higher amounts of labelled tracers.SPME coupled with GC/C/IRMS can be used to analyze (13)C-SCVAs at low enrichment (<0.5 MPE) within the physiological concentration measured in human plasma.  相似文献   

16.
17.
Stable isotope analysis of cellulose is an increasingly important aspect of ecological and palaeoenvironmental research. Since these techniques are very costly, any methodological development which can provide simultaneous measurement of stable carbon and oxygen isotope ratios in cellulose deserves further exploration. A large number (3074) of tree-ring α-cellulose samples are used to compare the stable carbon isotope ratios (δ(13)C) produced by high-temperature (1400°C) pyrolysis/gas chromatography (GC)/isotope ratio mass spectrometry (IRMS) with those produced by combustion GC/IRMS. Although the two data sets are very strongly correlated, the pyrolysis results display reduced variance and are strongly biased towards the mean. The low carbon isotope ratios of tree-ring cellulose during the last century, reflecting anthropogenic disturbance of atmospheric carbon dioxide, are thus overestimated. The likely explanation is that a proportion of the oxygen atoms are bonding with residual carbon in the reaction chamber to form carbon monoxide. The 'pyrolysis adjustment', proposed here, is based on combusting a stratified sub-sample of the pyrolysis results, across the full range of carbon isotope ratios, and using the paired results to define a regression equation that can be used to adjust all the pyrolysis measurements. In this study, subsamples of 30 combustion measurements produced adjusted chronologies statistically indistinguishable from those produced by combusting every sample. This methodology allows simultaneous measurement of the stable isotopes of carbon and oxygen using high-temperature pyrolysis, reducing the amount of sample required and the analytical costs of measuring them separately.  相似文献   

18.
Two new procedures for wine ethanol 13C/12C isotope ratio determination, using high-performance liquid chromatography and gas chromatography isotope ratio mass spectrometry (HPLC/IRMS and GC/IRMS), have been developed to improve isotopic methods dedicated to the study of wine authenticity. Parameters influencing separation of ethanol from wine matrix such as column, temperature, mobile phase, flow rates and injection mode were investigated. Twenty-three wine samples from various origins were analyzed for validation of the procedures. The analytical precision was better than 0.15 per thousand, and no significant isotopic fractionation was observed employing both separative techniques coupled to IRMS. No significant differences and a very strong correlation (r = 0.99) were observed between the 13C/12C ratios obtained by the official method (elemental analyzer/isotope ratio mass spectrometry) and the proposed new methodology. The potential advantages of the developed methods over the traditional one are speed (reducing time required from hours to minutes) and simplicity. In addition, these are the first isotopic methods that allow 13C/12C determination directly from a liquid sample with no previous ethanol isolation, overcoming technical difficulties associated with sample treatment.  相似文献   

19.
This study summarizes the results obtained from the doping control analysis during the period of the XXVIII summer Olympic Games (30 July-29 August 2004). The analysis of all doping control samples was performed at the Doping Control Laboratory (DCL)—the World Anti-Doping Agency (WADA) Accredited Laboratory of Athens. Three thousand six hundred and seventeen tests were conducted in total throughout the games. In 23 specimens the presence of a prohibited substance was confirmed. Sixteen of those were related to anabolic agents. The screened results were confirmed with various mass spectrometry analytical techniques, such as gas chromatography/high resolution mass spectrometry (GC/HRMS), gas chromatography/mass spectrometry (GC/MS), gas chromatography/combustion/isotope ratio mass spectrometry (GC/C/IRMS) and liquid chromatography/mass spectrometry (ion trap) (LC/MS). The results of the first time applied screening and confirmatory procedures for the detection of recombinant human growth hormone in serum were also presented. Besides, 107 therapeutic use exemptions (TUE) were verified for glucocorticosteroid and beta2-agonist use.  相似文献   

20.
Applied gas chromatography coupled to isotope ratio mass spectrometry.   总被引:6,自引:0,他引:6  
Compound-specific isotope analysis (CSIA) by isotope ratio mass spectrometry (IRMS) following on-line combustion (C) of compounds separated by gas chromatography (GC) is a relatively young analytical method. Due to its ability to measure isotope distribution at natural abundance level with great accuracy and high precision, GC-C-IRMS has increasingly become the method of choice in authenticity control of foodstuffs and determination of origin in archaeology, geochemistry, and environmental chemistry. In combination with stable isotope labelled compounds, GC-C-IRMS is also used more and more in biochemical and biomedical application as it offers a reliable and risk-free alternative to the use of radioactive tracers. The literature on these topics is reviewed from the advent of commercial GC-C-IRMS systems in 1990 up to the beginning of 1998. Demands on sample preparation and quality of GC separation for GC-C-IRMS are discussed also.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏