首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 388 毫秒
1.
The only relevant source for human exposure to dinitropyrenes is diesel engine emissions. Due to this specificity, dinitropyrenes may be used as biomarkers for monitoring human exposure to diesel engine emissions. Only few analytical methods have been described for the quantitation of dinitropyrenes and their metabolites, aminonitropyrenes, and diaminopyrenes. Therefore, for dinitropyrenes, aminonitropyrenes, and diaminopyrenes were selected as model compounds for the development of a sensitive HPLC-MS/MS method (high performance liquid chromatography coupled to triple quadrupole mass spectrometry) was to quantify polyaromatic amines and nitroarenes in biological matrices was developed optimal methods by comparing electrospray ionization (ESI), atmospheric pressure chemical ionization (APCI), and atmospheric pressure photoionization (APPI) sources. Dinitropyrene was not effectively ionized and diaminopyrene yielded mainly [M(.)](+) ions by electrospray ionization. With APCI and APPI, precursor ions of diaminopyrene and aminonitropyrene were [M + H](+) and [M(.)](-) for dinitropyrene. Precursor ions with [M - 30(.)](-) for dinitropyrene and [M - 30 + H](+) for aminonitropyrene were observed. Reversed and normal phase HPLC-MS/MS with ESI, APCI and APPI were optimized separately with respect to unequivocal analyte identification and sensitivity. Normal phase HPLC coupled to APPI-MS/MS gave the highest precision and sensitivity for aminonitropyrene (6%/0.2 pg on column) and dinitropyrene (9%/0.5 pg on column). The limit of detection in spiked rat plasma was 5 pg/100 microL for aminonitropyrene (accuracy 82%) and 10 pg/100 microL for dinitropyrene (accuracy 105%). In plasma of rats treated with dinitropyrene by oral administration, no detectable levels of dinitropyrene but higher aminonitropyrene levels compared with intratracheal instillation were observed. These findings clearly demonstrate that dinitropyrene was absorbed after oral and intratracheal application and that a reduction of nitro groups occurs to a high extent in the reductive environment of the intestine. To our knowledge, this is the first time that aminonitropyrene was observed in plasma after intratracheal or oral administration directly demonstrating the reductive metabolism of dinitropyrene in vivo.  相似文献   

2.
This article presents an analytical approach that used chemical derivatization to enhance mass spectrometric (MS) response in electrospray ionization (ESI) mode of 1-hydroxypyrene (1-OHP), a commonly used biomarker to monitor human exposure to polycyclic aromatic hydrocarbons (PAHs). The enhancement successfully enabled the desired detection of 50 pg/mL in human urine. The introduction of an MS-friendly dansyl group to 1-OHP enhanced both ionization efficiency in the ESI source and collision-activated dissociation (CAD) in the collision cell. The response increase was estimated to be at least 200-fold, and enabled the reduction of sample size to only 100 microL. The selective MS detection also facilitated a fast (run time 3 min) liquid chromatography (LC) method which successfully resolved the analyte and interferences. The sample processing procedure included enzymatic hydrolysis of glucuronide and sulfate conjugates, liquid-liquid extraction, derivatization with dansyl chloride and a final liquid-liquid extraction to generate clean extracts for LC/MS/MS analysis. This approach has been validated as sensitive, linear (50-1000 pg/mL), accurate and precise for the quantitation of 1-OHP in human urine. This is the first report of using chemical derivatization to enhance MS/MS detection with fast chromatography in the determination of 1-OHP in human urine.  相似文献   

3.
Rapid screening of clenbuterol in urine was performed by combining desorption electrospray ionization (DESI) and tandem mass spectrometry (MS/MS). Optimization experiments were carried out including the selection of substrates, spray solutions, nebulizing gas pressures, high-voltage power supplies and flow rates of spray solution. The limit of detection (LOD), defined as the lowest quantity that can be detected, was 5.0 pg for the pure compound. Using DESI coupled with solid-phase extraction (SPE), the linear response range was from 10 to 400 ng/mL (R(2) = 0.993) and the concentration LOD for urine sample was 2.0 ng/mL. The analysis for one spiked urine sample was achieved within 4 min. In addition to the fast analysis speed, MS/MS provided structural information for the confirmation of clenbuterol. Urine samples from different people were investigated and the recoveries were within 100 +/- 20%. The developed method can potentially be used for screening of clenbuterol in doping control.  相似文献   

4.
Bisphosphonates are extremely hydrophilic and structurally similar to many endogenous phosphorylated compounds, making their selective extraction from serum or urine very challenging. Many bisphosphonates lack strong chromophores for sensitive UV or fluorescence detection. We report here the first general approach to enable sensitive and selective quantitation of N-containing bisphosphonates by liquid chromatography/tandem mass spectrometry (LC/MS/MS) following derivatization with diazomethane. The novelty of the strategy lies in performing the derivatization on silica-based anion-exchange sorbents as an integrated step in the sample purification by solid-phase extraction (SPE). The 'on-cartridge' reaction with diazomethane not only led to higher efficiency of derivatization, but also enabled a more discriminatory recovery of the drug's derivatives. The derivatized bisphosphonates demonstrated improved chromatographic separation and increased sensitivity of the detection. The general applicability of the approach was demonstrated by validation of bioanalytical methods for risedronate and alendronate in human serum and urine. Sensitivity was achieved at the pg/mL level with merely 100-200 microL of sample.  相似文献   

5.
In order to quantify 1,3-dinitropyrene (DNP), 1,6-DNP and 1,8-DNP in soil, we developed an efficient clean-up procedure and a sensitive determination method using fluorescence detection. DNP isomers were efficiently cleaned by three stages of fractionation, i.e., a silica gel open column chromatography using stepwise elution and two further purification steps by high-performance liquid chromatography (PPLC) using a monomeric-type octadecylsilyl (ODS) column and a polymeric-type ODS column. The recoveries of DNPs during the whole clean-up process were 94% or more. The fraction corresponding to DNPs was injected into an analytical polymeric-type ODS column for HPLC to separate DNP isomers. The effluent from the analytical ODS column was directly introduced to a catalyst column, which was packed with 5 microns alumina coated with platinum and rhodium (Pt-Rh), in order to reduce DNPs to diamino compounds, and then the fluorescence of diaminopyrenes was detected. The immediate detection of diaminopyrene isomers after on-line reduction afforded a sensitive detection of DNP isomers. The detection limits for DNPs were in the range of 0.7 to 4 pg. These developed methods were applied to four soil samples collected at parks in residential areas.  相似文献   

6.
A new, simple, sensitive and specific liquid chromatography/electrospray ionization tandem mass spectrometric (LC/ESI‐MS/MS) method in precursor ion scanning (PIS) mode has been developed for the rapid detection of methylprednisolone acetate (MPA) and its metabolites in rat urine. A suitable product ion specific for methylprednisolone (MP) and MPA was selected after a fragmentation study on 20 (cortico)steroids at different collision energies (5–40 eV). Urine samples were simply treated with acetonitrile then dried in a SpeedVac system. The method was validated and compared with other PIS methods for detecting corticosteroids in human urine. It was more sensitive, with limit of detection (LOD) and lower limit of quantitation (LLOQ), respectively, of 5 and 10 ng mL?1. The method was applied for the analysis of rat urine collected before and after (24, 48, 72 h) intra‐articular (IA) injection of a marketed formulation of MPA (Depo‐Medrol®). MS/MS acquisitions were taken at different collision energies for the precursor ions of interest, detected in PIS mode, to verify the MP‐related structure. Six different metabolites were detected in rat urine, and their chemical structures were assigned with a computational study. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

7.
Mass spectrometers equipped with atmospheric pressure ion sources (API-MS) have been designed to be interfaced with liquid chromatographs (LC) and have rarely been connected to gas chromatographs (GC). Recently, we introduced a heated nebulizer microchip and showed its potential to interface liquid microseparation techniques and GC with API-MS. This study demonstrates the feasibility of GC-microchip atmospheric pressure photoionization-tandem mass spectrometry (GC-μAPPI-MS/MS) in the analysis of underivatized anabolic steroids in urine. The APPI microchip provides high ionization efficiency and produces abundant protonated molecules or molecular ions with minimal fragmentation. The feasibility of GC-μAPPI-MS/MS in the analysis of six selected anabolic steroids in urine samples was studied with respect to intra-batch repeatability, linearity, linear range, and limit of detection (LOD). The method showed good sensitivity (LODs 0.2-1 ng/mL), repeatability (relative standard deviation<10%), and linearity (regression coefficient≥0.9995) and, therefore, high potential for the analysis of anabolic steroids. Quantitative performance of the method was tested with two authentic urine samples, and the results were in good agreement with those obtained with conventional GC-electron ionization-MS after derivatization.  相似文献   

8.
A simple alternative method with minimal sample pretreatment is investigated for screening of amphetamines in small volume (using only 20 microL) of urine sample. The method is sensitive and selective. The method uses gas chromatography (GC) direct sample introduction (DSI) for on-line derivatization (acylation) of amphetamines to improve sensitivity. Furan as chemical ionization (CI) reagent in conjunction with tandem mass spectrometry (MS/MS) is used to improve selectivity. Low background with sharp protonated molecular ion peaks of analytes is the evidence of improvement in sensitivity and selectivity. Blank urine samples spiked with known amounts of amphetamine, methamphetamine, 3,4-methylenedioxyamphetamine, 3,4-methylenedioxymethamphetamine and 3,4-methylenedioxyethylamphetamine is analyzed. Selected ion monitoring of the characteristic product ions (m/z 119+136+150+163) using furan CI-MS/MS in positive ion mode is used for quantification. Limits of detection (LOD) between 0.4 and 1.0 ng mL(-1) and limits of quantitation (LOQ) between 1.0 and 2.0 ng mL(-1) are established. Linear response over the range of 1-1000 ng mL(-1) (r(2)>0.997) is observed for all analytes, except for methamphetamine (2.0-1000 ng mL(-1)). Good accuracy between 86 and 113% and precision ranging from 4 to 18% is obtained. The method is also tested on real samples of urine from suspected drug abusers. This method could be used for screening and determination of amphetamines in urine samples, however needs additional work for full validation.  相似文献   

9.
建立丹磺酰氯柱前衍生-超高效液相色谱-串联质谱法测定人体尿样中环己胺的方法。冷冻样品经解冻、离心后,用丹磺酰氯衍生,固相萃取小柱净化。目标化合物采用 Waters ACQUITY CSHTM C18色谱柱(50 mm×2.1 mm,1.7μm)分离,以甲醇和0.002 mol/L乙酸铵溶液为流动相梯度洗脱,采用电喷雾离子源电离、正离子多反应监测模式质谱检测。环己胺在2.5~200μg/L浓度范围内有较好的线性关系,相关系数大于0.999,回收率为98.7%~102.3%,精密度为3.1%~5.2%,检出限和定量限分别为1.0和3.0μg/L。结果表明,本方法操作简单、准确可靠,可适用于人体尿液中环己胺的定量分析。应用本方法测定200份学生尿液样品,环己胺检出率为34.5%。  相似文献   

10.
A rapid, selective and sensitive method was developed for the determination of eugenol concentration using an off-line dansyl chloride derivatization step to enhance signal intensity. The method consisted of a protein precipitation extraction followed by derivatization with dansyl chloride and analysis by full scan liquid chromatography electrospray quadrupole ion trap mass spectrometry (LC-ESI-QIT). The separation was achieved using a 100 x 2 mm C(8) analytical column combined with an isocratic mobile phase composed of 75:25 acetonitrile: 0.1% formic acid in water set at a flow rate of 0.25 mL/min. Signal intensity of the eugenol-dansyl chloride derivative was increased up to 100-fold as compared with the underivatized eugenol in positive electrospray mode. An analytical range of 100-20,000 ng/mL was used in the calibration curve of plasma and blood samples. The LOD observed was 0.5 pg injected on column. The novel method met all requirements of specificity, sensitivity, linearity, precision, accuracy and stability. In conclusion, a rapid and sensitive LC-ESI/MS/MS method using a derivatization agent was developed to enhance signal intensity of eugenol.  相似文献   

11.
Early detection of any preeclampsia biomarkers may lower the risk of mortality, both for a mother and a child. Our study focuses on techniques for preeclampsia biomarker identification by comparing the results of a method using liquid chromatography mass spectrometry in multiple reaction monitoring mode (LC-MS/MS) with those by the enzyme-linked immunosorbent assay (ELISA) test, as well as by comparing the obtained results with clinical data. In the proposed LC-MS/MS method a tryptic digest peptide charge derivatization strategy was used as a tool for sensitive detection of podocin, i.e., a previously discovered preeclampsia biomarker present in urine samples from pregnant women. Urine samples from pregnant women with diagnosed preeclampsia were collected at different stages of pregnancy and from healthy subjects, and then were analyzed by ELISA test and the proposed method with LC-MS/MS. Charge derivatization of the ε amino group of C-terminal lysine residues in tryptic digests by 2,4,6-triphenylpyrylium salt was performed to increase the ionization efficiency in the LC-MS/MS mode. Podocin was identified at the early stage of pregnancy, while its detection using an ELISA test was not possible. The protocol for urine sample preparation was optimized. Our results show that the proposed method by LC-MS/MS in combination with peptide charge derivatization, provides an ultrasensitive tool for diagnosis of preeclampsia, and provides earlier detection than a clinical diagnosis or ELISA test. The proposed solution may revolutionize medical diagnostics.  相似文献   

12.
A new approach to the selective comparative metabolite profiling of carboxylic acids in rat urine was established using CE‐MS and a method for positively pre‐charged and 2H‐coded derivatization. Novel derivatizing reagents, N‐alkyl‐4‐aminomethyl‐pyridinum iodide (alkyl=butyl, butyl‐d9 or hexyl), containing quaternary amine and stable‐isotope atoms (deuterium), were introduced for the derivatization of carboxylic acids. CE separation in positive polarity showed high reproducibility (0.99–1.32% RSD of migration time) and eliminated problems with capillary coating known in CE‐MS anion analyses. Essentially complete ionization and increased hydrophobicity after the derivatization also enhanced MS detection sensitivity (e.g. formic acid was detected at 0.5 pg). Simultaneous derivatization of one sample using two structurally similar reagents, N‐butyl‐4‐aminomethyl‐pyridinum iodide (BAMP) and N‐hexyl‐4‐aminomethyl‐pyridinum iodide, provided additional information for recognizing a carboxylic acid in an unknown sample. Moreover, characteristic fragmentation acquired by online CE‐MS/MS allowed for identification and categorization of carboxylic acids. Applying this method on rat urine, we found 59 ions matching the characteristic patterns of carboxylic acids. From these 59, 32 ions were positively identified and confirmed with standards. For comparative analysis, 24 standard carboxylic acids were derivatized by chemically identical but isotopically distinct BAMP and N‐butyl‐d9‐4‐aminomethyl‐pyridinium iodide, and their derivatization limits and linearity ranges were determined. Comparative analysis was also performed on two individual urine samples derivatized with BAMP and N‐butyl‐d9‐4‐aminomethyl‐pyridinium iodide. The metabolite profiling variation between these two samples was clearly visualized.  相似文献   

13.
A simple and sensitive method has been developed and validated for determining ethyl methylphosphonic acid (EMPA), isopropyl methylphosphonic acid (IMPA), isobutyl methylphosphonic acid (iBuMPA), and pinacolyl methylphosphonic acid (PMPA) in human urine using gas chromatography-tandem mass spectrometry (GC-MS/MS) coupled with solid phase derivatization (SPD). These four alkyl methylphosphonic acids (AMPAs) are specific hydrolysis products and biomarkers of exposure to classic organophosphorus (OP) nerve agents VX, sarin, RVX, and soman. The AMPAs in urine samples were directly derivatized with pentafluorobenzyl bromide on a solid support and then extracted by liquid–liquid extraction. The analytes were quantified with isotope-dilution by negative chemical ionization (NCI) GC-MS/MS in a selected reaction monitoring (SRM) mode. This method is highly sensitive, with the limits of detection of 0.02 ng/mL for each compound in a 0.2 mL sample of human urine, and an excellent linearity from 0.1 to 50 ng/mL. It is proven to be very suitable for the qualitative and quantitative analyses of degradation markers of OP nerve agents in biomedical samples.  相似文献   

14.
Eleven phenothiazine derivatives with heavy side-chains were found to be extractable from human whole blood and urine samples by solid-phase microextraction (SPME) with a polyacrylate-coated fiber. The fiber was then injected into the desorption chamber of an SPME-liquid chromatography (LC) interface for LC/tandem mass spectrometry (MS/MS) with positive ion electrospray (ES) ionization. All compounds formed base peaks due to [M + 1](+) ions by LC/ES-MS/MS. By use of LC/ES-MS/MS, the product ions produced from each [M + 1](+) ion showed base peaks due to side-chain liberation. Selected reaction monitoring (SRM) and selected ion monitoring (SIM) were compared for the detection of the 11 phenothiazine derivatives from human whole blood and urine. SRM showed much higher sensitivity than SIM for both types of sample. Therefore, a detailed procedure for the detection of drugs by SRM with SPME-LC/MS/MS was established and carefully validated. The extraction efficiencies of the 11 phenothiazine derivatives spiked into whole blood and urine were 0. 0002-0.12 and 2.6-39.8%, respectively. The regression equations for the 11 phenothiazine derivatives showed excellent linearity with detection limits of 0.2-200 ng ml(-1) for whole blood and 4-22 pg ml(-1) for urine. The intra- and inter-day precisions for whole blood and urine samples were not greater than 15.1%. The data obtained after oral administration of perazine or flupentixol to a male subject are presented.  相似文献   

15.
叶能胜  王小波  王继芬  谷学新 《应用化学》2010,27(10):1221-1224
建立了尿样中可卡因(COC)及其代谢物爱冈宁甲基酯(EME)的气相色谱检测方法。 采用液液萃取法提取尿样中可卡因和爱冈宁甲基酯,考察了萃取剂种类和用量、试样pH值以及萃取时间等因素对提取效果的影响。 结果表明,尿样中COC和EME的最佳液液萃取条件是:以V(氯仿)∶V(异丙醇)=9∶1为提取溶剂,调节样品溶液pH=9.5,在40 ℃ 水浴振荡提取6 min。 COC和EME日内精密度分别为1.73%和1.44%,日间精密度分别为2.57%和2.89%,最低检出限(LOD)为0.040 mg/L。 此法无需衍生化、快速、准确、灵敏度高,可同时检测尿样中COC和EME的含量。  相似文献   

16.
For the detection of anabolic steroid residues in bovine urine, a highly sensitive liquid chromatographic/electrospray ionization tandem mass spectrometric (LC/ESI-MS/MS) method was developed using both positive and negative ionization. For four compounds the ESI mode was not sensitive enough and gas chromatographic/mass spectrometric GC/MS detection was therefore still necessary as a complementary method. The sample clean-up consisted of solid-phase extraction (SPE) on a C(18) column followed by enzymatic hydrolysis and a second solid-phase extraction on a combination of a C(18) and a NH(2) column. After this last SPE clean-up, the eluate was split into two equal aliquots. One aliquot was further purified and after derivatization used for GC/MS analysis. The other aliquot was analyzed with LC/MS/MS in both ESI+ and ESI- modes. The method was validated according to the European Commission Decision 2002/657/EC. Decision limits (CCalpha) were between 0.16 and 1 ng ml(-1) for the compounds detected with the LC/MS/MS method. The developed method is used in routine analysis in our laboratory.  相似文献   

17.
A selective and sensitive electrospray ionization (ESI) mass spectrometry based method for detection of brassinosteroids (BS) in plant samples was developed. The limit of detection (LOD) was dramatically reduced over existing analytical methods using a microbore (1.00 mm) C18 column and chemical derivatization of free BS to dansyl-3-aminophenylboronates. The LOD in the selected-ion monitoring (SIM) mode for derivatized BS was 125 attomole (signal-to-noise ratio 3). The practical utility of the method is documented in Arabidopsis thaliana plant transformation of castasterone to brassinolide using a deuterium-labeled precursor. The method could be very useful for the detection of native BS in plant tissue and biosynthetic studies.  相似文献   

18.
Clenbuterol (CBL) is a potent beta(2)-adrenoceptor agonist used for the management of respiratory disorders in the horse. The detection and quantification of CBL can pose a problem due to its potency, the relatively low dose administered to the horse, its slow clearance and low plasma concentrations. Thus, a sensitive method for the quantification and confirmation of CBL in racehorses is required to study its distribution and elimination. A sensitive and fast method was developed for quantification and confirmation of the presence of CBL in equine plasma, urine and tissue samples. The method involved liquid-liquid extraction (LLE), separation by liquid chromatography (LC) on a short cyano column, and pseudo multiple reaction monitoring (pseudo-MRM) by electrospray ionization quadrupole time-of-flight tandem mass spectrometry (ESI-QTOF-MS/MS). At very low concentrations (picograms of CBL/mL), LLE produced better extraction efficiency and calibration curves than solid-phase extraction (SPE). The operating parameters for electrospray QTOF and yield of the product ion in MRM were optimized to enhance sensitivity for the detection and quantification of CBL. The quantification range of the method was 0.013-10 ng of CBL/mL plasma, 0.05-20 ng/0.1 mL of urine, and 0.025-10 ng/g tissue. The detection limit of the method was 13 pg/mL of plasma, 50 pg/0.1 mL of urine, and 25 pg/g of tissue. The method was successfully applied to the analysis of CBL in plasma, urine and various tissue samples, and in pharmacokinetic (PK) studies of CBL in the horse. CBL was quantified for 96 h in plasma and 288 h in urine post-administration of CLB (1.6 micro g/kg, 2 x daily x 7 days). This method is useful for the detection and quantification of very low concentrations of CBL in urine, plasma and tissue samples.  相似文献   

19.
A new derivatization and extraction technique termed as dispersive derivatization liquid-liquid extraction (DDLLE) speeds up the analysis process by removing the requirement for drying of the sample. The derivatization process takes place at the interface between the analyte containing aqueous phase and derivatization agent laden organic phase. The organic phase is highly dispersed using disperser solvent so that the total surface area is large. The derivatizing agent used is 1-(heptafluorobutyryl)imidazole and the resulting heptafluorobutyryl (HFB) derivatized analytes are partitioned into the organic phase. In addition to reduced sample preparation time, for some of the analytes, the HFB derivatives provide better spectral differentiation between isomers than conventional trimethylsilyl (TMS) derivatives. Method parameters for the DDLLE, such as extraction, and disperser solvent and their volume, type and amount of base, amount of heptafluorobutyrylimidazole and extraction time were optimized on diisopropylaminoethanol (DiPAE), ethyldiethanolamine (EDEA), triethanolamine (TEA) and thiodiglycol (TDG). The DDLLE was also used on various real world samples, which also includes few OPCW organized proficiency test and a spiked urine sample. The observed limit of detection (LOD) with 1mL of sample for DDLLE in full scan with AMDIS was 10ng/mL and with methane chemical ionization, multiple reaction monitoring (MRM) was 100pg/mL, i.e., 100fg on-column.  相似文献   

20.
建立了QuEChERS前处理结合气相色谱-质谱快速测定职业工人尿液中8种多溴联苯醚同系物的分析方法。尿液样在氯化钠和无水硫酸镁的脱水与盐析作用下以正己烷-丙酮混合液提取,采用C18去除提取液中的杂质,并采用气相色谱-负化学源质谱法在选择离子监测模式下测定,内标法定量。三至七溴联苯醚在1~100 pg/μL(十溴联苯醚为10~1 000 pg/μL)范围内线性关系良好,相关系数均大于0.999。待测物在3个加标水平下的平均回收率为91.7%~110.2%,相对标准偏差(RSD)小于10%。多溴联苯醚的检出限为0.3~36 pg/m L。该方法简单快速,灵敏度和选择性较高,适合职业工人体内污染物暴露水平监测。  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号