首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
A simple and highly selective electrochemical method was developed for the simultaneous determination of aspartame and cyclamate in dietary products at a boron-doped diamond (BDD) electrode. In square-wave voltammetric (SWV) measurements, the BDD electrode was able to separate the oxidation peak potentials of aspartame and cyclamate present in binary mixtures by about 400 mV. The detection limit for aspartame in the presence of 3.0x10(-4) mol L(-1) cyclamate was 4.7x10(-7) mol L(-1), and the detection limit for cyclamate in the presence of 1.0x10(-4) mol L(-1) aspartame was 4.2x10(-6) mol L(-1). When simultaneously changing the concentration of both aspartame and cyclamate in a 0.5 mol L(-1) sulfuric acid solution, the corresponding detection limits were 3.5x10(-7) and 4.5x10(-6) mol L(-1), respectively. The relative standard deviation (R.S.D.) obtained was 1.3% for the 1.0x10(-4) mol L(-1) aspartame solution (n=5) and 1.1% for the 3.0x10(-3) mol L(-1) cyclamate solution. The proposed method was successfully applied in the determination of aspartame in several dietary products with results similar to those obtained using an HPLC method at 95% confidence level.  相似文献   

2.
流动注射化学发光抑制法测定抗坏血酸   总被引:22,自引:0,他引:22  
李峰  张文艳  朱果逸 《分析化学》2000,28(12):1523-1526
基于抗坏血酸对Luminol-KIO4-H2O2体系化学发光反应的抑制作用,建立了化学发光抑制快速测定抗坏血酸的新方法。该方法线性范围为1.0*10^-7-1.0*10^-5mol/L,检出限为6.0*10^-8mol/L,对8.0*10^-7mol/L抗坏血酸11次平行测定的相对标准偏差为1.0%。用于维生素C片剂及注射液中抗坏血酸含量的测定,结果令人满意。  相似文献   

3.
A pressurized CEC (pCEC) coupled with on-column chemiluminescence (CL) detection was developed for direct determination of amino acids, which was based on the principle of an enhanced effect of Cu(II)-amino acid complexes on the CL reaction between luminol and hydrogen peroxide in alkaline solution. The effects of some important factors on pCEC separation and CL intensity were systemically investigated. Baseline separation of amino acids including L-histidine (L-His), L-threonine (L-Thr), and L-tyrosine (L-Tyr) was achieved by using a monolithic column with a mobile phase of 5.0x10(-3) mol/L phosphate buffer at pH 8.0 that contained 25% v/v methanol and 5.0x10(-4) mol/L luminol and 1.0x10(-5) mol/L Cu(II) at an applied voltage of -5 kV. The calibration curves of the analytes by plotting the peak height against corresponding concentration were linear over the range of 3.2x10(-6)-3.2x10(-4) mol/L for L-His, 4.1x10(-6)-4.1x10(-4) mol/L for L-Thr, and 6.0x10(-7)-3.0x10(-4) mol/L for L-Tyr. The LODs for L-His, L-Thr, and L-Tyr were 6.4x10(-7), 8.4x10(-7), and 3.0x10(-7) mol/L (S/N = 2), respectively. The proposed method was applied to the analysis of amino acid injection sample with satisfactory results. Mean recoveries for three amino acids were from 84.3 to 89.6%.  相似文献   

4.
Araujo L  Wild J  Villa N  Camargo N  Cubillan D  Prieto A 《Talanta》2008,76(1):111-115
In this work, the reactions of various copper ions with 1,3,3-trimethyl-2-[5-(1,3,3-trimethyl-1,3-dihydro-indol-2-ylidene)-penta-1,3-dienyl]-3H-indolium--more commonly known as dimethylindodicarbocyanine polymethyne dye (DIDC)--as well as the application of the results obtained for the development of a spectrophotometric method for the determination of Cu(I), Cu(II) and Cu(III) are described. Cu(I) and Cu(II) in the presence of chloride ions and DIDC reagent are extractable by a variety of organic solvents. It is important to emphasize that Cu(I) was extracted under considerably different experimental conditions than Cu(II). The optimum conditions for the extraction of the Cu ion associates with DIDC by amyl acetate and the determination of Cu(I) and Cu(II) were found to be: pH 3-5 and pH 3-6 and chloride concentrations of 0.5-0.8 mol L(-1) and 3-6 mol L(-1) for Cu(I) and Cu(II), respectively. The molar absorptivities for Cu(I) and Cu(II) are 1.8x10(5) L mol(-1) cm(-1) and 1.2x10(5) L mol(-1) cm(-1), respectively. A reaction mechanism is suggested. Cu(III) does not extract in the presence of chloride ions. However, Cu(III) is a strong oxidative agent which can cause the decolourisation of the DIDC reagent. The optimum conditions for Cu(III) determination were found to be: 2x10(-5) mol L(-1) DIDC; pH 8; water:acetone 4:1 medium. The developed procedures were tested for the determination of Cu(I), Cu(II) and Cu(III) in semiconductor samples.  相似文献   

5.
Nicotinamide (NA) yields a polarographic catalytic wave with a peak potential -1.38 V (vs. SCE) in 0.1 mol/L HAc-NaAc (pH 4.7)/4 x 10(-3) mol/L KIO3 buffer solution. The sensitivity of the catalytic wave increased in one order of magnitude as compared to that of the responding reduction wave without KIO3. Based on this observation, a new method for the determination of NA was recommended. The second order derivative peak current was proportional to the NA concentration in the range of 5 x 10(-8)- 6 x 10(-7) mol/L. 0.11-fold vitamin B1, 0.13-fold B2, 0.14-fold B6 and 8-fold nicotinic acid amounts do not interfere the determination of 1 x 10(-6) mol/L NA. The proposed method was used to determine the NA content in multivitamin tablets, with good agreement to the declared amount.  相似文献   

6.
The quadruple complex formed by terbium with 4-chlorosalicylic acid (CSA), EDTA and cetyltrimethylammonium bromide (CTMAB) has been used for the sensitive spectrofluorometric determination of terbium in mixed rare earths. The effect of the experimental conditions on the fluorescence intensity was defined. Under the optimum conditions selected, the fluorescence intensity was linear with the terbium concentration in the range of 3.0 x 10(-8)-1.0 x 10(-5) mol/L with a detection limit of 8.0 x 10(-9) mol/L (S/N = 3). It has been satisfactory for the determination of terbium in mixed rare earths with good recovery.  相似文献   

7.
Terbium sensitized fluorescence was used to develop a sensitive and simple spectrofluorimetric method for the determination of the anthranilic acid derivatives furosemide and mefenamic and tolfenamic acids. The method makes use of radiative energy transfer from anthranilates to terbium ions in alkaline methanolic solutions. Optimum conditions for the formation of the anthranilate-Tb3+ complexes were investigated. Under optimized conditions, the detection limits are 6 x 10(-9), 1.4 x 10(-8) and 9.0 x 10(-9) mol l-1 for furosemide, mefenamic acids and tolfenamic acid, respectively. The range of application is 2.5 x 10(-8)-5.0 x 10(-5) mol l-1 for all three drugs. The method was successfully applied to the determination of furosemide and mefenamic and tolfenamic acids in serum after extraction of the samples with ethyl acetate, evaporation of the organic layer under a stream of nitrogen at 40 degrees C and reconstitution of the residue with alkaline methanolic terbium solution prior to instrumental measurement. The mean recoveries from serum samples spiked with furosemide (5.0 x 10(-7), 2.0 x 10(-6) and 8.0 x 10(-6) mol l-1), mefenamic acid (3.0 x 10(-6), 9.0 x 10(-6) and 3.0 x 10(-5) mol l-1) and tolfenamic acid (3.1 x 10(-6), 12.5 x 10(-6) and 2.5 x 10(-5) mol l-1) were 96 +/- 8, 101 +/- 5 and 98 +/- 7%, respectively. The within-run precision (RSD) for the method for two serum samples of each drug varied from 2 to 8% and the day-to-day precision for two concentration levels varied from 2 to 13%.  相似文献   

8.
Hydroxyl radicals were generated in the Fenton reaction at pH 4 (Fe(2+) + H(2)O(2) --> Fe(3+) + .OH + OH-, k approximately equal to 60 L mol(-1) s(-1)) and by pulse radiolysis (for the determination of kinetic data). They react rapidly with 1,3-dimethyluracil, 1,3-DMU (k = 6 x 10(9) L mol(-1) s(-1)). With H(2)O(2) in excess and in the absence of O(2), 1,3-DMU consumption is 3.3 mol per mol Fe(2+). 1,3-DMUglycol is the major product (2.95 mol per mol Fe(2+)). Dimers, prominent products of .OH-induced reactions in the absence of Fe(2+)/Fe(3+) (Al-Sheikhly, M.; von Sonntag, C. Z. Naturforsch. 1983, 31b, 1622) are not formed. Addition of .OH to the C(5)-C(6) double bond of 1,3-DMU yields reducing C(6)-yl 1 and oxidizing C(5)-yl radicals 2 in a 4:1 ratio. The yield of reducing radicals was determined with tetranitromethane by following the buildup of nitroform anion. Reaction of 1 with Fe(3+) that builds up during the reaction or with H(2)O(2) gives rise to a short-chain reaction that is terminated by the reaction of Fe(2+) with 2, which re-forms 1,3-DMU. In the presence of O(2), 1.1 mol of 1,3-DMU and 0.6 mol of O(2) are consumed per mol Fe(2+) while 0.16 mol of 1,3-DMU-glycol and 0.17 mol of organic hydroperoxides (besides further unidentified products) are formed. In the presence of O(2), 1 and 2 are rapidly converted into the corresponding peroxyl radicals (k = 9.1 x 10(8) L mol(-1) s(-1)). Their bimolecular decay (2k = 1.1 x 10(9) L mol(-1) s(-1)) yields approximately 22% HO(2)./O(2).(-) in the course of fragmentation reactions involving the C(5)-C(6) bond. Reduction of Fe(3+) by O(2).(-) leads to an increase in .OH production that is partially offset by a consumption of Fe(2+) in its reaction with the peroxyl radicals (formation of organic hydroperoxides, k approximately 3 x 10(5) L mol(-1) s(-1); value derived by computer simulation).  相似文献   

9.
Nanqin G  Ruxiu C  Zhixin L  Lirong S 《The Analyst》2003,128(3):301-305
This paper reports a new method for detection of ROS scavengers including superoxide dismutase, ascorbic acid and glutathione based on a 'probe' of peroxidase-oxidase biochemical oscillator. The oscillation period and amplitude change with different concentrations of scavengers. The linear ranges of superoxide dismutase, ascorbic acid and glutathione are respectively 1.56 x 10(-4)-1.56 x 10(-3) mg mL(-1), 1.75 x 10(-7)-1.75 x 10(-5) mol L(-1) and 9.38 x 10(-7)-7.5 x 10(-5) mol L(-1). The selectivity, linearity and precision for superoxide dismutase, ascorbic acid, and glutathione are presented and discussed. The results compared well with other standard methods for determination of superoxide dismutase, ascorbic acid and glutathione. Some possible steps in the overall reaction mechanisms are discussed.  相似文献   

10.
The determination of iron(II) with 1,10-phenanthroline in aqueous solutions was carried out exemplarily by thermal lens spectrometry. The peculiarities of analytical reactions at the nanogram level of reactants can be studied using this method. Under the conditions of the competing reaction of ligand protonation, the overall stability constant for iron(II) chelate with 1,10-phenanthroline was determined at a level of n x 10(-7) mol L(-1), logbeta3 = 21.3+/-0.1. The rates of formation and dissociation of iron(II) tris-(1,10-phenanthrolinate) at a level of n x 10(-8) mol L(-1) were found to be (2.05+/-0.05) x 10(-2) min(-1) and (3.0+/-0.1) x 10(-3) min(-1), respectively. The conditions for the determination of iron(II) with 1,10-phenanthroline by thermal lensing were reconsidered, and ascorbic acid was shown to be the best reducing agent, which provided minimum and reproducible sample pretreatment. Changes in the conditions at the nanogram level improved both the selectivity and sensitivity of determination. The optimum measurement conditions for thermal lensing were determined not only by the absorption of the analyte and reagents, but also by the background absorption of the solvent. The limits of detection and quantification of iron(II) at 488.0 nm (excitation beam power 140 mW) are 1 x 10(-9) and 6 x 10(-9) mol L(-1), respectively; the reproducibility RSD for the range n x 10(-8)-n x 10(-6) mol L(-1) is 2-5%.  相似文献   

11.
For detection of phenolic compounds in environmental water samples we propose an amperometric biosensor based on tyrosinase immobilized in titania sol-gel. The analytical characteristics toward catechol, p-cresol, phenol, p-chlorophenol, and p-methylcatechol were determined. The linear range for catechol determination was 2.2 x 10(-7)-1.3 x 10(-5) mol L(-1) with a limit of detection of 9 x 10(-8) mol L(-1) and sensitivity 2.0 x 10(3) mA mol(-1) L. The influence of sample matrix components on the electrode response was studied according to Plackett-Burman experimental design. The potential interferents Mg(2+), Ca(2+), HCO3(-), SO4(2-), and Cl(-), which are usually encountered in waters, were taken into account in the examination. Cu(2+) was also taken into account, because CuSO(4) is sometimes added to a water sample, as a preservative, before determination of phenolic compounds. It was found that among the ions tested only Mg(2+) and Ca(2+) did not directly affect the electrode response. The developed biosensor was used for determination of catechol in spring and surface water samples using the standard addition method.  相似文献   

12.
Jin W  Li W  Xu Q  Dong Q 《Electrophoresis》2000,21(7):1409-1414
Capillary zone electrophoresis was employed for the determination of metronidazole using end-column amperometric detection with a gold microelectrode at a constant potential of -0.52V vs. saturated calomel electrode. To overcome interference of oxygen in the solution, a deaeration injector and a deaeration protector at the detection cell were used. The optimum conditions of separation and detection are 1.0 x 10(-3) mol/L potassium dihydrogen citrate (KH2C6H5O7) for the buffer solution, 20 kV for the separation voltage, and 5 kV and 10 S for injection voltage and injection time, respectively. The limit of detection is 6.0 x 10(7) mol/L or 0.78 fmole (S/N = 3). The relative standard deviation is 3.9% for the electrophoretic peak current. The method was applied to the determination of metronidazole in human urine.  相似文献   

13.
A fluorophotometric method for the determination of anionic surfactant sodium dodecyl sulphate (SDS) was proposed. The method is based on the quenching effect of SDS on the fluorescence of near-infrared (NIR) hydrophobic dye, 2-[4'chloro-7'(3'hexadecyl-2'benzothiazolinylidene)-3',5'-(1',3'-propanediyl)-1',3',5'-heptatriene-1'-yl]-3-ethylbenzothiazolium iodide (dye I) in the presence of Triton X-100. The calibration graph is linear in the concentration range from 0 to 2 x 10(-6) mol L(-1) of SDS with a detection limit (LOD) of 8.3 x 10(-8) mol L(-1). The relative standard deviation for the determination of 7 x 10(-7) mol L(-1) SDS was 4.1%. Recoveries of 95.3-110.3% were found for the addition to 1.0 x 10(-6) mol L(-1) SDS in the analysis of environmental water samples. Preliminary research shows that the fluorescence quenching is due to the formation of dye aggregate facilitated by SDS.  相似文献   

14.
A rapid and sensitive flow-injection chemiluminescence method is described for the determination of dichloro- and trichloroisocyanuric acids based on the chemiluminescence produced during their reaction with luminol in alkaline medium. The effects of analytical and flow-injection variables on these chemiluminescence systems and determination of both oxidants are discussed. The optimized method yielded 3sigma detection limits of 8x10(-8) and 5x10(-8) mol L(-1) for the sodium dichloroisocyanurate and trichloroisocyanuric acid, respectively. The optimum conditions were found to be as follows: NaOH, 1x10(-1) mol L(-1); luminol, 5x10(-3) mol L(-1); KI, 2x10(-3) mol L(-1) and flow rate, 3.5 mL min(-1).  相似文献   

15.
Jin W  Xu Q  Li W 《Electrophoresis》2000,21(7):1415-1420
Capillary zone electrophoresis was employed for the determination of clozapine using an end-column amperometric detection at a carbon fiber array microdisk electrode with simplified capillary/electrode alignment. The optimum conditions of separation and detection are: Britton-Robinson buffer, pH 2.0 (1.3 x 10(-2) mol/L total concentration of acids, 3.2 x 10(-3) mol/L NaOH), 15 kV for separation voltage, 5 kV and 10 s for injection voltage and injection time, respectively. The limit of detection is 4.2 x 10(-7) mol/L or 1.2 fmole (signal to noise, S/N = 2). The relative standard deviation is 1.4% for the migration time and 2.5% for the electrophoretic peak current. The method was applied to the determination of clozapine in human blood. The recovery of the method is between 94-104%.  相似文献   

16.
Glycine was covalently grafted on to a glassy carbon electrode (GCE) by amine cation radical formation in electrooxidation of the amino-containing compound. X-ray photoelectron spectroscopy (XPS) and cyclic voltammetry proved the immobilization of glycine on the GCE. The modified electrode reduced the overpotentials of dopamine (DA) and ascorbic acid (AA) by approximately 0.15 V and 0.23 V, respectively, and resolved the overlapping voltammetric response of DA and AA into two well-defined voltammetric peaks in cyclic voltammetry (CV) or differential pulse voltammetry (DPV), unlike the unmodified GCE; this can be used for the simultaneous determination of these species in a mixture. The differential pulse peak current was linearly dependent on DA and AA concentration in the range 5 x 10(-6)-8 x 10(-4) mol L(-1) and 6 x 10(-5)-4 x 10(-3) mol L(-1), with correlation coefficients of 0.996 and 0.994, respectively. The detection limits (3delta) for DA and AA were 1.8 x 10(-6) mol L(-1) and 2.1 x 10(-5) mol L(-1), respectively. The modified electrode is very sensitive, selective and stable, and has been applied to the determination of DA and AA simultaneously in samples with satisfactory results.  相似文献   

17.
Guan Y  Chu Q  Fu L  Ye J 《Journal of chromatography. A》2005,1074(1-2):201-204
A new and efficient method for the determination of antioxidants [Propyl gallate (PG), tert-butylhydroquinone (TBHQ), butylated hydroxyanisole (BHA), and butylated hydroxytoluene (BHT)] in cosmetics has been established by using micellar electrokinetic capillary chromatography with electrochemical detection (MECC-ED). Under the optimum conditions of the method, all analytes were successfully separated within 13 min at the separation voltage of 18 kV in a 20 mmol/L borate running buffer (pH 7.4) containing 25 mmol/L sodium dodecyl sulfate. The excellent linearity was obtained in the concentration range from 5.0 x 10(-4) to 2.0 x 10(-6) mol/L and the detection limits (S/N = 3) of PG, TBHQ, BHA, and BHT range from 3 x 10(-7) to 3 x 10(-6) mol/L.  相似文献   

18.
A simple, rapid and sensitive spectrophotometric procedure for the determination of platinum has been elaborated. Pt traces were determined in the form of the PtCl(6)(2-) complex in hydrochloric acid solution whose concentration varies from 0.01 to 2 mol L(-1) by measuring the absorbance at 260 nm. The detection limit is 4.7 x 10(-7) mol L(-1), the linearity range from 2 x 10(-6) mol L(-1) to 7 x 10(-6) mol L(-1), and the correlation coefficient is r=0.9990. No significant interferences were observed from a majority of the investigated ions, such as Zn(II), Pb(II), Mn(II), Cd(II), Co(II) and Ni(II) with the exception of Cu(II), Sb(III), Fe(III), Pd(II), Sn(II) and I(-) ions. The method was successfully applied for the determination of Pt traces in different solid samples and the recovery from inorganic materials was studied.  相似文献   

19.
Rao Z  Zhang X  Baeyens WR 《Talanta》2002,57(5):993-998
A new chemiluminescence (CL) flow-injection method is proposed for the determination of 1,3-dichloro-5,5-dimethylhydantoin (DDH). The method is based on the chemiluminescent reaction of DDH and luminol-H(2)O(2) in an alkaline medium (pH 12.0-12.5). The concentration of the analyte shows a good linear relationship with the produced luminescence intensity in the range of 3.0x10(-8) to 8.0x10(-6) mol l(-1). The detection limit of the proposed method is 1.0x10(-8) mol l(-1) and the relative standard deviation (R.S.D.) is 4.7% (n=5) at 5.0x10(-7) mol l(-1). This method was successfully applied to the determination of trace amounts of this disinfectant in water samples obtained from five different swimming pools. Satisfying recovery values were also obtained.  相似文献   

20.
Capillary zone electrophoresis was employed for the determination of histamine using end-column amperometric detection with a carbon fiber microelectrode, at a constant potential. The optimum conditions of separation and detection were 10 mmol/L phosphate buffer, pH 5.6 for the buffer solution, 15 kV for the separation voltage, and 1.35 V (versus SCE) for the detection potential. The linear range was from 6.3 x 10(-7) to 1.5 x 1(-5) mol/L with the regression coefficient of 0.9997, and the detection limit was 4.0 x 10(-7) mol/L (S/N = 3). The proposed method was successfully applied to the direct determination of histamine in the beer samples without any sample clean-up procedures.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号