首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 203 毫秒
1.
Fullerence C60‐cryptand 22 was prepared and successfully applied as the electric carrier in the PVC electrode membrane of a bifunctional ion‐selective electrode for cations, e.g., Ag+ ions as well as anions, e.g., I? ions. The bifunctional ion‐selective electrode based on C60‐cryptand 22 can be applied as a Silver (Ag+) ion selective electrode with an internal electrode solution of 10?3 M AgNO3 in water (pH = 6.3), or as an Iodide (I?) ion selective electrode with an acidic internal electrode solution of 10?4 M KI(aq) (pH = 2) in which the cryptand 22 is protonated, and the C60‐cryptand 22 is changed to C60‐Cryptand22–H+ and becomes an anionic electro‐carrier to absorb the I? ion. The Ag+ ion selective electrode based on C60‐cryptand 22 gave a linear response with a near‐Nernstian slope (59.5 mV decade?1) within the concentration range 10?1‐10?3 M Ag+(aq). The Ag+ ion electrode exhibited comparatively good selectivity for silver ions, over other transition‐metal ions, alkali and alkaline earth metal ions. The Ag+ ion selective electrode with good stability and reproducibility was successfully used for the titration of Ag+(aq) with Cl? ions. The Iodide (I?) Ion selective electrode based on protonated C60–cryptand22‐H+ also showed a linear response with a nearly Nernstian slope (58.5 mV decade?1) within 10?1 ‐ 10?3 M I? (aq) and exhibited good selectivity for I? ions and had small selectivity coefficients (10?2–10?3) for most of other anions, e.g., F? , OH?, CH3COO?, SO42?, CO32?, CrO42?, Cr2O72? and PO43? ions.  相似文献   

2.
A fast, simple and sensitive square-wave voltammetric (SWV) method for the determination of trace amounts of furazolidone (FZ) in urine is reported. A three-electrode system containing stationary mercury dropping (SMDE) working electrode, Pt auxiliary electrode and Ag/AgCl reference electrode was used throughout. Briton-Rabinson buffer solution is used as both pH adjusting agent and supporting electrolyte. The calibration graph showed good linearity in the concentration range of 20–900 ng ml?1 of furazolidone with a regression coefficient of 0.9996. The equation Δ(i) = 0.0095CFZ + 0.234 was used for calculation of furazolidone concentration in the sample solution, where CFZ is the concentration of furazolidone in ng ml?1 and Δ(i) is the difference between voltammogram peak currents of sample and blank solution. The RSD for 8 replicate measurements of a 60 ng ml?1 solution and LOD of the proposed method were found to be 2.2% and 5.2 ng ml?1, respectively. The procedure was successfully applied to the determination of furazolidone in urine samples.  相似文献   

3.
A PVC (poly vinyl chloride) membrane electrode for lead ion based on 2-(((E)-2-((E)-1-(2-hydroxyphenyl)methyliden)hydrazono)metyl)phenol (HMHMP) as a membrane carrier was prepared. This electrode exhibited linear response with Nernstian slope of 29.2?±?0.2?mV per decade within the concentration range of 2.0?×?10?7–1.0?×?10?1?M lead ion. The limit of detection, as determined from the intersection of the extrapolated linear segments of the calibration plot, was 8.0?×?10?8 M. The electrode exhibited high selectivity for Pb (II). The response time of the electrode was about 5–10?s for different concentrations. The electrode is suitable for use in aqueous solutions in a pH range of 5.0–7.5. It was used as an indicator electrode in a titration of Pb (II) with chromate at constant pH. This electrode was used for the determination of lead in ore samples, and the results were in agreement with those obtained with an atomic absorption spectroscopy (AAS) method. Also lead selective electrode was used for monitoring of lead in spiked samples of the Zayanderud River and waste water by the potentiometry technique.  相似文献   

4.
Cyclic voltammetry was used to investigate the electrochemical behaviour of ascorbic acid at a carbon—epoxy composite electrode modified with the electron mediator cobalt phthalocyanine. The modified electrode reduced the overpotential necessary for the oxidation of the vitamin by approximately 150 mV to 0.21 V vs. The saturated calomel electrode; the process was dependent on the pH of the supporting electrolyte, but independent of ionic strength over the range studied. The relative standard deviation (r.s.d.) of the peak heights of the cyclic voltammograms was 0.81% for a 1 × 10?4 M ascorbic acid solution (n = 7). The optimum supporting electrolyte was found to be 0.05 M phosphate buffer (pH 5).Amperometry in stirred solutions was then done at an applied potential of +0.25 V. The limit of detection was 0.65 ng ml?1 and the calibration graph was linear in the range 175 ng ml?1?50 μg ml?1. The method was used to determine ascorbic acid concentrations in single- and multivitamin preparations; the recovery was 97.86% for the vitamin added to one preparation. The r.s.d. for the analyses in these samples was about 5%. For comparison, the vitamin was also determined in these tablets using LC with UV detection at 254 nm; the correlation coefficient for the levels determined was 0.9989 (p = 0.0007).  相似文献   

5.
This work presents a new ultra‐sensitive method of Al(III) as Al‐cupferron complex voltammetric determination, in 0.04 M ammonium sulfate of pH=6.1 and 0.003 M cupferron by environmentally friendly and durable Bismuth Bulk Annular Band Electrode (BiABE). The optimal measuring parameters include: potential window from ?700 to ?1250 mV versus Ag|AgCl, preconcentration time and potential of 120 s, ?700 mV, respectively. The electrode surface can be activated by fast in situ method: applying short conditioning by the potential of ?1300 mV. The best obtained analytical parameters are: range of linearity 0.2–1.2 μg L?1 with high sensitivity of 1.333 μA/μg L?1, limit of detection 0.04 μg L?1 and repeatability below 2.3 %. The described procedure was verified using various CRMs, i. e. surface waters, waste waters and tea leaves. Satisfactory recovery values were obtained in the interval 99.2–103.5 %. Developed DPV procedure was used to determine Al in tap and natural waters in aspect of recovery of aluminum, which was added to the samples. For the first time, we tested also Al removal efficiency from water by the water filters mounted in the trip bottle.  相似文献   

6.
A method is described for the routine determination of gold as its chloride or cyanide complex by anodic stripping voltammetry at a glassy carbon electrode coupled to a microprocessor-controlled voltammeter. The preferred supporting electrolyte is 0.1 M HCl/0.32 M HNO3, with plating at ?200 mV or ?1200 mV (vs. Ag/AgCl). The stripping peak potentials range from 830 to 1150 mV (vs. Ag/AgCl) depending on concentration and plating time. Precision (percent relative standard deviation) is better than 5 % for a range of concentrations between 5 μg l?1 and 1000 μg l?1. The detection limit is about 5 μg l?1 for a 5-min plating period. Interferences from Cu, Hg, Ag and other electroactive species are overcome by preliminary extraction with diethyl ether.  相似文献   

7.
The fluoroquinolone antibacterial agent ofloxacin was studied by adsorptive stripping voltammetry. Controlled interfecial accumulation of ofloxacin on a static mercury drop electrode in the hanging mercury drop mode provides high sensitivity. The linear concentration range was 0.079–197.5 μg ml?1 when using a 60-s preconcentration at ?1 V vs. Ag/AgCl in Britton-Robinson buffer of pH 6.00. The detection limit of ofloxacin was 1 ng ml?1. The precision is excellent with a relative standard deviation of ca. 0.75% at a concentration of 0.848 μg ml?1.  相似文献   

8.
《Analytical letters》2012,45(15):2683-2697
Abstract

Two flow-injection methods for the determination of 4-aminobiphenyl by amperometry (glassy carbon electrode) and spectrophotometry are proposed. A sample volume of 200 or 400 μl containing an analyte concentration of 0.1–1.0 μg ml?1 or 0.8–24.0 μg ml?1 for amperometric or spectrophotometric detection, respectively, is injected into a carrier stream containing 0.04 or 0.02 M Britton-Robinson buffer at pH 10.0 or 8.0, respectively.

The throughput thus achieved is 200 (amperometry) and 240 samples/h (spectrophotometry) and the relative standard deviation less than 2.5% and 4.2% respectively.

Both methods were applied to the determination of 4-aminobiphenyl in commercially available, legally permitted food colouring additive.  相似文献   

9.
《Analytical letters》2012,45(5):891-903
ABSTRACT

Melatonin forms a 1:1 inclusion complex with methyl-β-cyclodextrin with an association constant of 139 ? 30 M?1 at 20 °C. The effect of several cyclodextrins and derivatives on the fluorescence spectra of melatonin was studied with a great increase of fluorescence signal when methyl-β-cyclodextrin was employed. Optimal conditions of the method were: [methyl-β-cyclodextrin] = 0.01 M and temperature 20 °C; the pH does not affect the luminescence emission. The linear dynamic range (LDR) was 50-3000 ng ml?1 and a limit of detection of 10 ng ml?1 of melatonin was obtained with a relative standard deviation (RSD) of 0.77% (at 0.3 μg ml?1 level). This simple method was satisfactorily applied to the determination of melatonin in pharmaceutical preparations and urine.  相似文献   

10.
A novel copper(II)-selective electrode based on graphite oxide/imprinted polymer composite was developed for the electrochemical monitoring of copper(II) (Cu2+) ions. The electrode exhibited highly selective potentiometric response to Cu2+ with respect to common alkaline, alkaline earth and heavy metal cations. The composite composition studies indicated that the most suitable composite composition performing the most promising potentiometric properties was 20.0% ionophore (Cu2+-ion imprinted polymer), 10.0% paraffin oil, 5.0% multiwalled carbon nanotubes, and 65.0% graphite oxide. The fabricated electrode exhibited a linear response to Cu2+ over the concentration range of 1.0?×?10??6–1.0?×?10??1?M (correlation coefficient of 0.9998) with a sensitivity of 26.1?±?0.9?mV decade??1. The detection limit of the fabricated electrode was determined to be 4.0?×?10??7?M. The electrode worked well in the pH range of 4.0–8.0. The electrode had stable, reversible and fast potentiometric response (3?s). In addition, the electrode had a lifetime of more than 1 year. The analytical applications of the proposed electrode were performed using as an indicator electrode for the potentiometric titration of Cu2+ with ethylene diamine tetraacetic acid solution and for the determination of Cu2+ of spiked river, dam, and tap water samples. The obtained results for potentiometric titration and water samples were satisfactory.  相似文献   

11.
The organometallic compounds triphenyltinsalicylate (TPTS) and triphenylsiliconsalicylate (TPSS) were found to be trypanocidal against culture forms of Trypanosoma congolense. Both compounds at 0.4–5 µmol ml?1 completely killed the parasites in vitro within 3‐8 min after incubation. A dosage of 1.5 µmol ml?1 TPTS killed at least 50% of the parasite population, which was preceded by a cluster effect as observed under phase contrast microscopy. Also, 3.5 µg ml?1 of TPSS was required to kill 50% of the T. congolense cells. At a low dosage of 2–10 µg ml?1, it was feasible to monitor the effect and mode of action of the organometallic compounds. There was a 50% reduction in the amount of synthesized cholesterols in the presence of 6 µg ml?1 and 10 µg ml?1 of TPTS and TPSS respectively. TPTS and TPSS also non‐competitively inhibited pyrophosphatase from lysed T. congolense with Ki values of 3.6 µM and 8.5 µM respectively. In the in vivo experiments, TPTS cured T. congolense infected mice at a dosage of 2–10 mg kg day?1 for 4 days. TPSS was, however, completely inactive in vivo. The use of organometallic compounds in the design of trypanocides is discussed. Copyright © 2002 John Wiley & Sons, Ltd.  相似文献   

12.
A new PVC-membrane electrode for Co2+ ions based on N,N′-di(thiazol-2-yl)formimidamide (TF) as membrane carrier has been developed. The electrode resulted in Nernstian response (29.5?±?0.4?mV decade?1) for Co2+ ion over a wide concentration range (2.5?×?10?7 ?1.0?×?10?1?M) with a detection limit of 6.1?×?10?8?M. The sensor has a response time of about 10?s, and can be used for at least 2 months without observing any deviation from the Nernstain response. The electrode revealed good selectivity towards cobalt(II) ion over a wide variety of alkali, alkaline earth, transition, and heavy metal ions and could be used in the pH range 2.0–7.0. The electrode was used for determination of Co2+ in real samples.  相似文献   

13.
Magnetic solid phase extraction (MSPE) based on cetyltrimethylammonium bromide (CTAB)-coated magnetic iron oxide nanoparticles (C-MIONPs) was investigated for the separation, preconcentration and determination of Rose Bengal (RB) in aqueous solutions. The influences of different analytical parameters such as pH, temperature, ionic strength, volume of desorbent solvent, amount of adsorbent and interfering ions in the adsorption of RB on C-MIONPs were investigated. The RB adsorption on C-MIONPs follows Langmuir isotherm. The sizes of C-MIONPs were in the range of 20–80 nm. The method was capable of determining RB concentration in the range of 0.01–1.20 μg ml?1. The limit of detection (LOD) of RB based on three times the standard deviation of the blank (3Sb) was found to be 5.91 × 10–3 μg ml?1 (n = 8). The relative standard deviation (RSD) for 0.3 μg ml?1 and 0.8 μg ml?1 of RB were 4.1% and 1.1%, respectively. The proposed method was applied to the determination of RB in Brucella Antigen solution and water samples from the Karoon River.  相似文献   

14.
New amineptine hydrochloride (Am-Cl) ion-selective electrodes (conventional type) based on amineptinium-tetraphenylborate (I) and amineptinium-phosphomolybdate (II) were prepared. The electrodes exhibited mean slopes of calibration graphs of 57.9?mV and 53.8?mV per decade of (Am-Cl) concentration at 25?°C for electrodes (I) and (II), respectively. The electrodes can be used within the concentration range 3.16×10?5?10?2?M (Am-Cl) at a pH range of 2.0–3.9 for both electrodes. The standard electrode potentials were determined at different temperatures and used to calculate the isothermal coefficients of the electrodes, which were 0.00172?V?°C?1 and 0.00091 V?°C?1 for (I) and (II) electrodes, respectively. The electrodes showed a very good selectivity for (Am-Cl) with respect to a number of inorganic cations and sugars. The standard addition method is successfully applied to determine (Am-Cl) in pure solutions and in amineptine-containing tablets.  相似文献   

15.
《Analytical letters》2012,45(12):2515-2531
ABSTRACT

Propofol is coupled with 2, 6-dichloroquinone-4-chlorimide (DCQ) in a reaction buffered at pH 9.6 to give a colored product having an analytically useful maximum at 635 nm. The factors affecting the color generation were optimized and incorporated in the procedure. The reacted propofol has a molar absorptivity of 3.9 × 10?4 L mol?1 cm?1, and Beer's law is obeyed for concentrations 1-5 μg ml?1 with detection limit 0.25 μg ml?1. The method was found applicable to biological fluids (plasma and urine) spiked with propofol at concentration levels 1-5 μg ml?1 for plasma and 1-5 μg 0.5 ml?1 urine (less sensitivity is obtained with urine volumes above 0.5 ml) with detection limits 0.28 μg ml?1 for plasma and 0.4 μg 0.5 ml?1 urine. The average recovery for the commercial preparation (1% w/v propofol emulsion intravenous injection for infusion) was 99.54% with an RSD of 1.05%. The method was validated by an adopted HPLC method. The results obtained by the HPLC method for the commercial preparation were statistically compared with the proposed method and evaluated at the 95% confidence limits.  相似文献   

16.
A differential pulse polarographic method for the determination of the herbicide thiazopyr has been developed. The polarographic study of thiazopyr exhibited two well-defined cathodic peaks within the pH range of 1.0 to 8.0. The variation of pH and polarographic parameters indicated that the optimum conditions under which thiazopyr could be reduced were a pH 7.0 BR buffer solution, a reduction peak potential of ?1270 mV (vs. SCE), scan rate of 5 mV s?1, pulse amplitude of 50 mV with pulse duration of 50 ms at an ambient temperature of 25 ± 3°C. The main reduction peak was characterised by cyclic voltammetry as being irreversible and diffusion-controlled. A linear relationship between the peak current and the concentration of thiazopyr was obtained in the range of 0.43–38.6 µg mL?1, with a detection limit of 0.127 µg mL?1. The proposed method was successfully applied to the determination of thiazopyr in spiked fruit juice and soil samples. The mean recoveries of the 19.8 µg g?1 and 3.96 µg mL?1 thiazopyr spiked to soil and orange juice were 20.2 ± 1.0 µg g?1 and 3.84 ± 0.12 µg mL?1, at 95% confidence level, respectively. The sufficiently good recoveries and low relative standard deviation (RSD) data confirm the high accuracy and precision of the proposed method. The interferences effects of several commonly used pesticides and inorganic species were also studied. Interfering effects were eliminated either by providing selectivity with pH, or using EDTA as complexing agent.  相似文献   

17.
《Analytical letters》2012,45(5):837-852
Abstract

A simple, rapid, sensitive, and reproducible procedure for assaying norfloxacin (NOR), ciprofloxacin (CIP), and ofloxacin (OFL) was investigated. The procedure is based on the reaction of selected drugs with Sudan II (I), Congo red (II), and Gentian violet (III) in universal buffer to give soluble ion‐pair complexes. The effects of various parameters have been studied. Beer's law plots were obeyed in the concentration ranges 0.5–11 µg ml?1, whereas Ringbom optimum ranges were 0.7–9.5 µg ml?1. The apparent molar absorptivity (6.4×104 L mol?1 cm?1), Sandell sensitivity (4.99 ng cm?2), detection (0.13 µg ml?1), and quantification (0.44 µg ml?1) limits were calculated. The relative standard deviation for ten determinations, for samples containing 4.0 µg ml?1, was found to be 1.40%. The influence of commonly employed excipients in the determination of the studied drugs was examined. There was no interference from degradate product results from thermal and hydrolytic treatments. The results obtained by the proposed procedure were statistically validated. The developed procedure was successfully applied to the determination of the studied drugs in dosage forms and biological fluids.  相似文献   

18.
A sensitive, simple and reproducible square-wave cathodic adsorptive stripping voltammetric method is developed for the determination of 2-mercaptobenzimidazole (MBIM) in different water samples using a static mercury drop electrode (SMDE) as a working electrode. The solution conditions and instrumental parameters were optimized for the determination of MBIM by square-wave cathodic adsorptive stripping voltammetry. This method is based on a sensitive adsorptive reduction peak of the MBIM at ?0.532 V vs. Ag/AgCl reference electrode in a Britton-Robinson buffer at pH 10.0. The linear concentration range was 20–600 ng ml?1 when using 0.0 V as the accumulation potential. The detection limit of the method was calculated to be 8.41 ng ml?1. The precision was excellent with relative standard deviations (n = 20) of 2.30%, 1.71%, 2.25% and 1.33% at MBIM concentrations of 40, 90, 200 and 500 ng ml?1, respectively. The proposed voltammetric method is used for the determination of MBIM in different spiked water samples.  相似文献   

19.
《Electroanalysis》2003,15(2):108-114
An imprinted polymer modified hanging mercury drop electrode (HMDE) in Model 303A system in conjunction with a PAR Model 264A Polarographic Analyzer/Stripping Voltammeter has been used for the selective analysis of a diquat herbicide viz., 5,6‐dihydropyrazino[1,2,3,4‐[lmn]‐1,10‐phenanthrolinium dichlorides in differential pulse cathodic stripping voltammetry mode. Complex aqueous samples (drinking water and agricultural soil suspension), spiked with a diquat herbicide, were directly analyzed by the adsorptive accumulation of the analyte over the working electrode (accumulation potential ?0.8 V (vs. Ag/AgCl), accumulation time 120 s, pH 7.0, supporting electrolyte 0.1 M KCl, scan rate 10 mV s?1, pulse amplitude 25 mV). The limit of detection for diquat herbicide was found to be 0.34 nmol L?1 (0.1 ppb, RSD 2%, S/N=2).  相似文献   

20.
A method is described for the determination of arsenic involving hydride generation and atomic absorption spectrometry with an improved long graphite-tube furnace capable of considerably higher temperatures than the conventional quartz-tube heaters. Arsine is generated with sodium tetrahydroborate, held in a nitrogen-cooled trap and then swept with helium into an alumina tube (19 cm long) placed within the graphite furnace. The optimum conditions for determination of arsenic are given. The detection limit is 0.2 ng ml?1 with RSD of 2–3%. Results for various NBS Standard Reference Materials agreed well with expected values and were as follows: orchard leaves, 10 ± 1 μg g?1; tomato leaves, 0.28 ± 0.03 μg g?1; bovine liver, 0.046 ± 0.005 μg g?1.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号