首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
建立了胶束电动毛细管色谱结合电化学安培检测同时分析中药马齿苋中多巴胺和去甲肾上腺素的方法。考察了缓冲液的浓度、pH值、十二烷基硫酸钠(SDS)浓度以及工作电极电势对分离检测的影响。在优化的条件下,多巴胺和去甲肾上腺素在1.0×10-6~5 0×10-4mol/L范围内有良好线性,浓度检测限(S/N=3)分别为8 7×10-7mol/L和4 2×10-7mol/L,质量检测限分别为1 45fmol和0 41fmol。该方法组分定性可靠,不需要衍生处理,选择性好。将该法应用于中药马齿苋样品的分析,获得了较好的结果。  相似文献   

2.
Sun X  Jin W  Li D  Bai Z 《Electrophoresis》2004,25(12):1860-1866
A novel method for the determination of alkaline phosphatase (ALP) isoenzymes in individual fibroblast cells of mouse bone marrow was developed by combining capillary electrophoresis with an on-capillary enzyme-catalyzed reaction and electrochemical detection. In this method, a single an cell, followed by 5.0 x 10(-2) mol/L Na2B4O7- 3.0 x 10(-2) mol/L NaCl (pH 9.8) as cell lysis solution, was injected into the inlet of the separation capillary by electromigration. The cell was lysed by applying a voltage of 2 kV. The ALP isoenzymes in the cell were preseparated at 20 kV for 1 min, and then allowed to react for 30 min with disodium phenyl phosphate as enzyme substrate in the running buffer. ALP converted disodium phenyl phosphate into its product, phenol, at a relatively high reaction rate without consumption, with resultant amplification of the signal on prolonged reaction time, producing an adequate amount of product for final detection. A mass detection limit as low as 3.5 x 10(-21) mol/L (corresponding to 1.5 nU) was achieved. Finally, the two zones of products generated by ALP isoenzymes were detected at the outlet of the capillary by using the end-capillary amperometric detection at a carbon fiber microdisk bundle electrode with a constant potential.  相似文献   

3.
Capillary zone electrophoresis was employed for the determination of diclofenac sodium using an end-column amperometric detection with a carbon fiber microelectrode, at a constant potential of 0.83 V vs. saturated calomel electrode. The optimum conditions of separation and detection are 4.90 x 10(-3) mol/l Na2HPO4-3.10 x 10(-3) mol/l NaH2PO4 (pH 7.0) for the buffer solution, 10 kV for the separation voltage, 5 kV and 10 s for the injection voltage and the injection time, respectively. The limit of detection is 2.5 x 10(-6) mol/l or 5.2 fmol (S/N=2). The relative standard deviation is 0.8% for the migration time and 4.7% for the electrophoretic peak current. The method was applied to the determination of diclofenac sodium in human urine.  相似文献   

4.
A simple and sensitive capillary electrophoretic method was developed for the separation and determination of sodium methyldithiocarbamate (metham), manganese ethylenebisdithiocarbamate (maneb) and ethyl xanthate in boric acid buffer by direct UV absorbance detection at lambda = 254 nm. The separation is dependent on pH and nature of the buffer. The detection limits (S/N = 3) are 1.7 x 10(-6) mol/L for ethyl xanthate, 1.3 x 10(-6) mol/L for metham and 2.1 x 10(-6) mol/L for maneb. The method has been successfully applied to the analysis of wheat samples spiked with maneb and in a commercial sample.  相似文献   

5.
Guan Y  Chu Q  Fu L  Ye J 《Journal of chromatography. A》2005,1074(1-2):201-204
A new and efficient method for the determination of antioxidants [Propyl gallate (PG), tert-butylhydroquinone (TBHQ), butylated hydroxyanisole (BHA), and butylated hydroxytoluene (BHT)] in cosmetics has been established by using micellar electrokinetic capillary chromatography with electrochemical detection (MECC-ED). Under the optimum conditions of the method, all analytes were successfully separated within 13 min at the separation voltage of 18 kV in a 20 mmol/L borate running buffer (pH 7.4) containing 25 mmol/L sodium dodecyl sulfate. The excellent linearity was obtained in the concentration range from 5.0 x 10(-4) to 2.0 x 10(-6) mol/L and the detection limits (S/N = 3) of PG, TBHQ, BHA, and BHT range from 3 x 10(-7) to 3 x 10(-6) mol/L.  相似文献   

6.
Jin W  Xu Q  Li W 《Electrophoresis》2000,21(7):1415-1420
Capillary zone electrophoresis was employed for the determination of clozapine using an end-column amperometric detection at a carbon fiber array microdisk electrode with simplified capillary/electrode alignment. The optimum conditions of separation and detection are: Britton-Robinson buffer, pH 2.0 (1.3 x 10(-2) mol/L total concentration of acids, 3.2 x 10(-3) mol/L NaOH), 15 kV for separation voltage, 5 kV and 10 s for injection voltage and injection time, respectively. The limit of detection is 4.2 x 10(-7) mol/L or 1.2 fmole (signal to noise, S/N = 2). The relative standard deviation is 1.4% for the migration time and 2.5% for the electrophoretic peak current. The method was applied to the determination of clozapine in human blood. The recovery of the method is between 94-104%.  相似文献   

7.
A method based on capillary electrophoresis with electrochemical detection (CE-ED) has been developed for the determination of hesperidin (HP) and synephrine (SP) in the Chinese traditional herbal drug, Pericarpium Citri Reticulatae, the dried rind of the ripe fruits of Citrus reticulata Blanco (mandarin orange). The effects of some important factors such as the acidity and concentration of running buffer, separation voltage, and detection potential were investigated to determine the optimum conditions. The working electrode was a 300 microm diameter carbon disc electrode positioned opposite the outlet of the capillary. Both analytes could be well separated within 5 min in a 40 cm long capillary at a separation voltage of 12 kV in 50 mmol L(-1) borate buffer (pH 9.0). Excellent linearity was observed for the dependence of peak current on analyte concentration in the range from 2.5 x 10(-6) to 1.0 x 10(-3) mol L(-1) for SP and from 5.0 x 10(-6) to 1.0 x 10(-3) mol L(-1) for HP. The detection limits (S/N=3) for SP and HP were 4.96 x 10(-7) mol L(-1) and 6.54 x 10(-7) mol L(-1), respectively. This method has been successfully applied for the analysis of real samples, with satisfactory results.  相似文献   

8.
A sensitive method for the simultaneous determination of chromium(III) (Cr3+) and chromium(VI) (CrO4(2-)) using in-capillary reaction, capillary electrophoresis (CE) separation and chemiluminescence (CL) detection was developed. The chemiluminescence reaction was based on luminol oxidation by hydrogen peroxide in basic aqueous solution catalyzed by Cr3+ ion followed by capillary electrophoresis separation. Based on in-capillary reduction, chromium(VI) can be reduced by acidic sodium hydrogensulfite to form chromium(III) while the sample is running through the capillary. Before the electrophoresis procedure, the sample (Cr3+ and CrO4(2-)), buffer and acidic sodium hydrogensulfite solution segments were injected in that order into the capillary, followed by application of an appropriate running voltage between both ends. As both chromium species have opposite charges, Cr3+ ions migrate to the cathode, while CrO4(2-) ions, moving in the opposite direction toward the anode, react with acidic sodium hydrogensulfite which results in the formation of Cr3+ ions. Because of the migration time difference of both Cr3+ ions, Cr(III) and Cr(VI) could be separated. The running buffer was composed of 0.02 mol l(-1) acetate buffer (pH 4.7) with 1 x 10(-3) mol l(-1) EDTA. Parameters affecting CE-CL separation and detection, such as reductant (sodium hydrogensulfite) concentration, mixing mode of the analytes with CL reagent, CL reaction reagent pH and concentration, were optimized. The limits of detection (LODs) of Cr(III) and Cr(VI) were 6 x 10(-13) and 8 x 10(-12) mol l(-1) (S/N=3), respectively. The mass LODs for Cr(III) and Cr(VI) were 1.2 x 10(-20) mol (12 zmol) and 3.8 x 10(-19) mol (380 zmol), respectively.  相似文献   

9.
磺胺类人工合成甜味剂的毛细管电泳/电导法分离检测   总被引:3,自引:0,他引:3  
采用15 mmol/L Tris-10 mmol/L H3BO3-0.2 mmol/L EDTA为电泳运行液,0.2%四乙烯五胺为电渗流抑制剂,融硅石英毛细管(45 cm×50 μm),负高压分离(-15 kV),柱端接触式电导检测,建立了磺胺类人工合成甜味剂(糖精钠、安赛蜜、甜蜜素)的高效毛细管电泳/电导法分离检测方法.糖精钠、安赛蜜、甜蜜素的线性检测范围分别为0.8 ~120、1.1 ~120、1.5 ~120 μmol/L,检出限分别为0.3、0.4、0.6 μmol/L.详细讨论了电泳运行液的组成、浓度以及进样方式对灵敏度和分离度的影响.该法用于市售饮料中3种甜味剂的分离检测,结果满意.  相似文献   

10.
周建忠  廖杰  钱小红  董芳霆 《色谱》1997,15(2):159-160
建立了用毛细管胶束电动色谱法(MEKC)分离19种PTH氨基酸的方法,并探讨了电压、pH值、温度、胶束浓度对氨基酸迁移时间的影响。方法具有速度快、灵敏度高、样品用量少的优点。  相似文献   

11.
Cao W  Liu J  Yang X  Wang E 《Electrophoresis》2002,23(21):3683-3691
A new end-column electrochemiluminescence (ECL) detection technique coupling to capillary electrophoresis (CE) is characterized. A 300 microm diameter Pt working electrode was used to directly couple with a 75 microm inner diameter separation capillary without an electric field decoupler. The hydrodynamic cyclic voltammogram (CV) of Ru(bpy) 3 2+ showed that electrophoretic current did not affect the ECL reaction. The presence of high-voltage (HV) field only resulted in the shift of the ECL detection potential. The distance of capillary to electrode was an important parameter for optimizing detection performance as it determined the characteristics of mass transport toward the electrode and the actual concentration of Ru(bpy) 3 2+ in the detection region. The optimum distance of capillary to electrode was decided by the inner diameter of the capillary, too. For a 75 microm capillary, the working electrode should be placed away from the capillary outlet at a distance within the range of 220-260 microm. The effects of pH value of ECL solution and molecular structure of analytes on peak height and theoretical plate numbers were discussed. Using the 75 microm capillary, under the optimum conditions, the method provided a linear range for tripropylamine (TPA) between 1 x 10(-10) and 1 x 10(-5) mol/L with correlation coefficient of 0.998. The detection limit (signal-to-noise ratio S/N = 3) was 5.0 x 10(-11) mol/L. The relative standard deviation in peak height for eight consecutive injections was 5.6%. By this new technique lidocaine spiked in a urine sample was determined. The method exhibited the linear range for lidocaine from 5.0 x 10(-8) to 1.0 x 10(-5) mol/L with correlation efficient of 0.998. The limit of detection (S/N = 3) was 2.0 x 10(-8) mol/L.  相似文献   

12.
Zhou J  Chen Y  Cassidy R 《Electrophoresis》2000,21(7):1349-1353
Separation and determination of erythromycin, spiramycin and oleandomycin by capillary zone electrophoresis coupled with fast reductive voltammetric detection using an Hg-film electrode was investigated in a simple aqueous phosphate buffer system. The influence of pH, concentration of phosphate, applied voltage, capillary length and dimension on the separation was examined and optimized. The entire separation of erythromycin, spiramycin, and oleandomycin was achieved in a 0.2 mol/L phosphate buffer system without organic modifiers. The electrochemical detection parameters, such as electrode material, applied waveform, scan rate, preconcentration potentials and preconcentration times, were investigated and discussed. This approach provides high separation efficiency and high sensitivity for all compounds, with detection limits (3 x peak-to-peak baseline noise) of 7.5 x 10(-8) mol/L for spiramycin, and 3 x 10(-7) mol/ L for erythromycin and oleandomycin. The calibration plot of peak areas for each separated peak vs. concentration of analyte was found to be linear over three orders of magnitude.  相似文献   

13.
A simple, reliable and reproducible method, based on capillary zone electrophoresis with amperometric detection, has been developed for the determination of idarubicin in human urine. A carbon disk electrode was used as working electrode. The optimal conditions of separation and detection were pH 5.6 phosphate buffer (0.20 mol/L), 22 kV for the separation voltage and 1.00 V (vs. Ag/AgCl, 3 mol/L KCl) for the detection potential. The linear range was from 4.0 x 10(-7) to 2.0 x 10(-5) mol/L with a regression coefficient of 0.9986, and the detection limit was 8.0 x 10(-8) mol/L. The method was directly applied to the determination of idarubicin in spiked human urine without any other sample pretreatment except filtration, and the assay results were satisfactory.  相似文献   

14.
The separation of three common anabolic steroids (methyltestosterone, methandrostenolone and testosterone) was performed for the first time by capillary EKC. Different charged CD derivatives and bile salts were tested as dispersed phases in order to achieve the separation. A mixture of 10 mmol/L succinylated-beta-CD with 1 mmol/L beta-CD in a 50 mmol/L borate buffer (pH 9) enabled the separation of the three anabolic steroids in less than 9 min. Concentration LODs, obtained for these compounds with low absorption of UV light, were approximately 5 x 10(-5) mol/L. The use of online reverse migrating sample stacking with large-volume injection (the effective length of the capillary) enabled to improve the detection sensitivity. Sensitivity enhancement factors (SEFs) ranging from 95 (for testosterone) to 149 (for methyltestosterone) were achieved by single stacking preconcentration. Then, the possibilities of multistep stacking to improve the sensitivity for these analytes were investigated. SEFs obtained by double stacking preconcentration ranged from 138 to 185, enabling concentration LODs of 2.79 x 10(-7) mol/L (for methyltestosterone), 3.47 x 10(-7) mol/L (for testosterone) and 3.56 x 10(-7) mol/L (for methandrostenolone). Although online triple stacking preconcentration was achieved, its repeatability was very poor and SEFs for the studied analytes were not calculated.  相似文献   

15.
A universal detector based on backscatter interferometry has been developed to perform nanoliter volume refractive index measurements for on-chip sodium dodecyl sulfate (SDS) gel based (polyethylene oxide gel) separations and quantification label-free proteins. The on-chip interferometric backscatter detector (OCIBD) system consists of a simple, folded optical train based on the interaction of a laser beam with an etched channel in the shape of half cylinder in a fused-silica plate. The backscattered light from the channel takes on the form of a high-contrast interference pattern that contains information related to the bulk properties of the fluid located within the probe or detection volume of 2.32 x 10(-9) L. Depending on capillary electrophoresis (CE) injection method, the positional changes of the interference pattern extrema (fringes) allow for the quantification of unlabeled proteins at levels ranging from 11 to 310 amol (2.7 x 10(-8)mol/L) with a linear dynamic range of 2.5 decades (egg albumin). Using OCIBD microchannel-based SDS capillary gel electrophoresis (SDS/CGE), separation and detection of five label-free proteins was achieved in less than 100 seconds with detection limits ranging from 0.95 pg (1.1 x 10(-16)mol or 2.5 x 10(-7)mol/L) of calmodulin to 7.0 pg (1.0 x 10(-16)mol or 2.4 x 10(-7)mol/L) for bovine serum albumin (BSA) without signal filtering or active thermal control. This development shows that a universal detector based on backscatter interferometry can be used effectively for on-chip label-free solute analysis.  相似文献   

16.
程宏英  曹玉华 《色谱》2007,25(5):681-685
采用毛细管电泳-电化学检测方法,以对羟基苯甲酸为自由基捕捉剂,测定了硫酸铜-维生素C反应体系(pH 7.4)中生成的羟基自由基。研究了电极电位、运行液的pH值、电泳电压及进样时间对体系中反应物和产物分离的影响,得到了最优化的测定条件;讨论了体系中各反应物浓度和反应时间对产物浓度的影响。以直径为300 μm的碳圆盘电极为检测电极,工作电极电位为0.95 V(vs.SCE),目标产物3,4-二羟基苯甲酸在1.5×10-4~6.0×10-6 mol/L范围内线性关系良好,检测限(S/N=3)为1.5×10-6 mol/L。应用该方法,研究测定了不同品种菊花的抗氧化活性。  相似文献   

17.
pH-mediated dual-cloud point extraction (dCPE) technique for capillary electrophoresis (CE) determination of phenol and m-nitrophenol is proposed in this paper. This technique for the preconcentration and clean-up of the two analytes includes two steps through simple pH-mediation. The analytes are transferred into surfactant-rich phase in the first step (under acidic condition) with Triton X-114 as the extractant because the two analytes become hydrophobic in acidic solution. They were back-extracted into alkaline aqueous phase in the second cloud point step. Because the concentration of Triton X-114 in the final aqueous solution after dCPE is only around critical micelle concentration, its adsorption on the inner wall of capillary and its possible influence on electrophoretic separation are eliminated. Baseline separation of phenol and m-nitrophenol is realized in a 60 cm x 75 microm i.d. capillary at 18 kV using 50 mM boric acid solution (pH 9.5). The preconcentration factors are 24.0 for phenol and 22.5 for m-nitrophenol. The detection limits of phenol and m-nitrophenol are 2.0 x 10(-6) mol L(-1) and 2.5 x 10(-6) mol L(-1), respectively. The proposed method was successfully applied to the determination of two analytes in spiked natural water samples.  相似文献   

18.
Huang Y  Duan J  Chen Q  Chen G 《Electrophoresis》2004,25(7-8):1051-1057
Eight enkephalin-related peptides were derivatized using fluorescein isothiocyanate (FITC), and the derivatization products were separated and detected by capillary electrophoresis with laser-induced fluorescence detection. The optimum molar ratio of FITC and peptide for derivatization was found to be 40:1, and 5 mmol/L sodium borate buffer (pH 9.2) was selected as derivatization media in order to get the high efficiency. Enkephalin-related peptides were completely separated in the pH range of 10.51-10.60 in a running buffer consisting of 100 mmol/L sodium borate and 60 mmol/L sodium dodecyl sulfate (SDS). The detection limit for these eight enkephalins ranged from 0.18 to 2.25 nmol/L, and the linear response range was 1.0 x 10(-6) to 1.0 x 10(-9) mol/L with correlation coefficients between 0.9947-0.9988. A separation efficiency as high as 380000 theoretical plates could be obtained for these analytes.  相似文献   

19.
Jin W  Dong Q  Yu D  Ye X 《Electrophoresis》2000,21(8):1535-1539
Capillary zone electrophoresis was employed for the determination of myoglobin in human urine using end-column amperometric detection with a carbon fiber microelectrode at a constant potential of 1.80 V vs. saturated calomel electrode (SCF). The optimum conditions of separation and detection are: 3.73 x 10-4 mol/L sodium diethyl malonyl urea (barbitone sodium), 1.34 x 10-4 mol/L HCl for the buffer solution, 20 kV for separation voltage, 5 kV and 5 s for injection voltage and injection time, respectively. The limit of detection is 4.4 x 10-8 mol/L or 84 amole signal to noise (S/N = 2). The relative standard deviation is 2.9% for the migration time and 2.5% for the electrophoretic peak current. The method can be used for the determination of myoglobin in human urine. The samples can be directly injected and need no pretreatment. The method is also rapid, less than 2 min, and has a recovery rate of 94-106%.  相似文献   

20.
Fang L  Kang J  Yin XB  Yang X  Wang E 《Electrophoresis》2006,27(22):4516-4522
CE with electrochemiluminescence (ECL) detection technique was successfully applied for the chiral separation of a kind of class IA antiarrhythmic racemic drug. To the best of our knowledge, this is the first report of ECL detection used in chiral CE. To get better detection sensitivity and good enantioresolution at the same time, the conditions of capillary inlet and outlet buffer were systematically optimized. Unlike the traditional chiral separation method, the buffers we used in the capillary inlet and outlet differed from each other in terms of buffer pH, ionic strength, type of BGE as well as buffer composition. Under the optimum conditions, baseline enantioseparation and highly sensitive detection of the enantiomers were achieved. Wide linear relationship of each enantiomer was achieved in the range of 5 x 10(-7) to 2 x 10(-5) mol/L with relative coefficients of 0.996 and 0.997, respectively. The detection limits were estimated to be 8 x 10(-8) and 1.0 x 10(-7) mol/L (S/N = 3) for the enantiomers, respectively. In addition, a successful application of this new method to the chiral separation of the racemic drug in spiked plasma samples confirmed the validity and applicability of the chiral CE-ECL method.  相似文献   