首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 93 毫秒
1.
This study evaluates solid-phase micro-extraction (SPME) coupled with gas chromatography–mass spectrometry (GC–MS) to determine trace levels of bis-phenol A in water and leached from plastic containers. In our study, we used very thin composite membranes prepared in the laboratory. The extraction using headspace post-derivatization with bis(trimethylsilyl) trifluoroacetamide (BSTFA), containing 1 % trimethylchlorosilane (TMCS) vapor, following SPME was compared with extraction without derivatization. The SPME experimental procedures to extract bis-phenol A in water were optimized with a relatively polar polyacrylate (PA)-coated fiber, an extraction time of 50 min, and desorption at 300 °C for 2 min. Headspace derivatization following SPME was performed using 7 μL of BSTFA with 1 % TMCS at 65 °C for 30 s. The precision was 5.2 % without derivatization and 9.0 % headspace derivatization. The detection limit was determined to be at the nanogram per liter level. When SPME was used following headspace derivatization, the detection limit was one order of magnitude better than that achieved without derivatization. The results of this study reveal the adequacy of the SPME–GC–MS method for analyzing bisphenol A leached from plastic containers. The concentrations of bisphenol A leached from plastic containers into water ranged from 0.7 to 78.5 μg L?1.  相似文献   

2.
Matrix-assisted laser desorption/ionization mass spectrometry (MALDI-MS) has been a major approach for glycan analysis. However, the preferential cleavage of the sialic acid moiety by in- and post-source decay influences the determination of sialylated glycans by MALDI-MS. Many chemical derivatization methods were introduced to stabilize the sialylated glycan during MALDI-MS. Among current derivatization methods, methylamidation is a promising means for simultaneous analysis of natural sialylated glycans regardless of their sialic acid linkage types. Here, a novel derivatization method was developed, in which proteins were conjugated on the solid-phase support in order to stabilize the sialic acids by methylamidation and to reduce sample loss and contamination during the derivatization process. This derivatization strategy was used to investigate N-glycans from fetuin, a glycoprotein containing different types of complex N-glycans. The developed method was also applied to the N-glycan profiling of human serum from patients and healthy volunteers. Results were consistent with N-glycan profiling by HPLC-fluorescence detection. This new method provided a sensitive, simple, and robust approach for profiling glycan structures of complex samples.  相似文献   

3.
Free fatty acids (FFAs), major cellular metabolites, play an important role during tumor pathogenesis. Enhanced de novo fatty acid synthesis in tissues is a characteristic feature of cancer. Therefore, measurement of FFA concentration in biological samples is beneficial for cancer research and clinical diagnosis. Herein, a rapid, stable, and sensitive detection methodology was established to simultaneously quantify 22 FFAs using high-performance liquid chromatography/electrospray ionization tandem mass spectrometry (HPLC/ESI–MS/MS). The HPLCMS/MS system was run in negative ion mode for 15 min using multiple reaction monitoring. The lipids were extracted from colon tissues of colon cancer patients and then injected into the HPLCMS/MS system for analysis. Colon samples were analyzed by inter-day repeatability and intra-day repeatability, with less than 5 % deviation for most fatty acids. This approach is successful to determine low picogram concentrations of each FFA molecule using milligrams of tissue, and provides a promising method for FFA microanalysis in clinical samples.  相似文献   

4.
A sensitive and ultra-fast method utilizing the laser diode thermal desorption ion source using atmospheric pressure chemical ionization coupled to tandem mass spectrometry (LDTD-APCI-MS/MS) was developed for the quantitative analysis of BKM120, an investigational anticancer drug in human plasma. Samples originating from protein precipitation (PP) followed by salting-out assisted liquid-liquid extraction (SALLE) were spotted onto the LazWell? plate prior to their thermal desorption and detection by tandem mass spectrometry in positive mode. The validated method described in this paper presents a high absolute extraction recovery (>90 %) for BKM120 and its internal standard (ISTD) [D8]BKM120, with precision and accuracy meeting the acceptance criteria. Standard curves were linear over the range of 5.00 to 2000 ng mL?1 with a coefficient of determination (R 2) >0.995. The method specificity was demonstrated in six different batches of human plasma. Intra- and inter-run precision as well as accuracy within ±20 % at the lower limit of quantification (LLOQ) and ±15 % (other levels) were achieved during a three-run validation for quality control (QC) samples. The post-preparative stability on the LazWell? plate at room temperature was 72 h and a 200-fold dilution of spiked samples was demonstrated. The method was applied successfully to three clinical studies (n?=?847) and cross-checked with the validated LC-ESI-MS/MS reference method. The sample analysis run time was 10 s as compared to 4.5 min for the current validated LC-ESI-MS/MS method. The resultant data were in agreement with the results obtained using the validated reference LC-ESI-MS/MS assay and the same pharmacokinetic (PK) parameters were calculated for both analytical assays. This work demonstrates that LDTD-APCI-MS/MS is a reliable method for the ultra-fast quantitative analysis of BKM120 which can be used to speed-up and support its bioanalysis in the frame of the clinical trials.  相似文献   

5.
Nonsteroidal anti-inflammatory drugs (NSAIDs) are the group of drugs having the therapeutic efficacy of analgesic and antipyretic. To detect health-threatening residues of NSAIDs, a fast and easy multiresidue method based on liquid chromatography tandem mass spectrometry (LC-MS/MS) was described. Ten NSAIDs were extracted from the tissues using 2 mL of acetonitrile and 0.1 mL of 2 mM ammonium formate in distilled water. After clean-up using C18 sorbent, it was evaporated under nitrogen, reconstituted with 1 mL distilled water and analyzed by LC-MS/MS. The method was validated based on guideline for residue testing laboratory. Furthermore, the method has also been applied successfully to detect ten NSAIDs from bovine, porcine, and chicken liver tissues. In a total of 315 liver samples tested, acetylic salicylic acid was detected from 28 porcine and 2 chicken liver tissues at levels of 13?~?576 and 50?~?53 ng/g, respectively. Subsequently, paracetamol was detected in 15 porcine liver tissues with a detection levels of 28?~?381 ng/g. Phenylbutazone and its metabolite, oxyphenylbutazone, were detected at 247 and 15 ng/g range in one of the bovine liver tissue, respectively.  相似文献   

6.
The dynamic rheological behavior of high density polyethylene (HDPE)/ultrahigh molecular weight polyethylene (UHMWPE) blends, low density polyethylene (LDPE)/UHMWPE blends and linear low density polyethylene (LLDPE)/ UHMWPE blends was measured in parallel plate rheometer at 200°C. The analysis of log-additivity rule, Cole-Cole plots and Han curves of the three series blends indicated that the LDPE/UHMWPE blends were miscible in the melt, while the HDPE/UHMWPE blends and LLDPE/UHMWPE blends showed phase separation. The DSC results of LLDPE/UHMWPE blends and HDPE/UHMWPE blends were consistent with the rheological properties, while for the thermal properties of LDPE/UHMWPE blends, results revealed three endothermic peaks, which indicated a liquid-solid phase separation in LDPE/UHMWPE blends.  相似文献   

7.
β-phase polyvinylidene fluoride (PVDF)–BaTiO3 nanocomposite samples have been prepared by solution mixing method. XRD data represent that the crystallinity of PVDF decreases with increase in loading level of BaTiO3 nanoparticles. DSC curve represents that the melting point of PVDF is lightly affected by loading concentration of BaTiO3. The morphology and microstructure of PVDF and PVDF embedded by BaTiO3 nanofillers were investigated by using inverted contrast microscopy (ICM) and scanning electron microscopy (SEM). FTIR interferrometry is proven that PVDF and BaTiO3 are not chemically interacting; therefore, interaction of BaTiO3 is van der Waals type of interaction. The thermally stimulated discharge current (TSDC) of PVDF and PVDF–BaTiO3 nanocomposites sample was characterized by single peak. The observed TSDC peak is discussed on the basis of dipolar and interfacial polarization.  相似文献   

8.
The ability of MALDI TOF MS (matrix-assisted laser desorption ionisation time-of-flight mass spectrometry) to identify cultivable microflora from two waste disposal sites from non-ferrous metal industry was analysed. Despite the harsh conditions (extreme pH values and heavy metal content in red mud disposal site from aluminium production or high heavy metal content in nickel sludge), relatively high numbers of bacteria were recovered. In both environments, the bacterial community was dominated by Gram-positive bacteria, especially by actinobacteria. High-quality MALDI TOF mass spectra were obtained but most of the bacteria isolates could be not identified using MALDI Biotyper software. The overall identification rate was lower than 20 %; in two of the environments tested identification rates were lower than 10 %. As a dominant bacterial species, Microbacterium spp. in drainage water from an aluminium red mud disposal site near ?iar nad Hronom, Bacillus spp. in red mud samples from the same site, and Arthrobacter spp. from nickel smelter sludge near Sereï were identified by a combination of the Biolog system and 16S rRNA sequence analysis. As the primary focus of the MALDI TOF MS-based methodology is directed towards medically important bacteria, reference database spectra expansion and refinement are needed to improve the ability of MALDI TOF MS to identify environmental bacteria, especially those from extreme environments.  相似文献   

9.
The 4-POBN[α-(4-pyridyl-l-oxide)-N-tert-butyl-nitrone] radical adducts of ethyl and pentyl radicals were determined by a combination of high performance liquid chromatography (HPLC) combined with electron paramagnetic resonance (EPR) with HPLC-electrospray (ESI)-mass spectrometry and HPLC-thermospray (TSP)-MS. The identifIcation of the peak corresponding to the spin-trapped radical was done by performing HPLC-EPR under the same chromatographic conditions as the HPLC-MS. The radical adducts could be determined by both techniques, even though for ESI only 12 μL/min of the total 1 mL/min HPLC flow rate could be directed into the ion source.  相似文献   

10.
Papou&#;ek  Roman  Pataj  Zolt&#;n  Nov&#;kov&#;  Petra  Lemr  Karel  Bart&#;k  Petr 《Chromatographia》2014,77(17):1145-1151

Acrylamide and acrolein are two short-chained hazardous compounds with neurotoxic, carcinogenic, and mutagenic effects. The aim of this paper is to describe a fast and simple procedure for simultaneous determination of both acrylamide and acrolein under standard conditions, suggest a suitable calibration protocol for custom analysis, and demonstrate its applicability to the analysis of gaseous products from, e.g., cigarettes, cigars, or electronic cigarettes. A gas chromatography–mass spectrometry (GC–MS) method was developed to quantify acrylamide and acrolein in smoke vapor from electronic cigarettes, tobacco cigarettes, and cigars. Nonionic and highly polar molecules with a low boiling point and molecular mass need a suitable derivatization method to achieve appropriate retention and selectivity on commonly used relatively nonpolar stationary phases and to enhance the molecular mass for easy MS detection. The derivatization of acrylamide and acrolein was carried out by a bromination method with elemental bromine. The dibromo derivatives were extracted into an organic solvent and following a dehydrobromination procedure the samples were injected into the GC–MS system. Important experimental parameters were varied, after which the bromination time was defined as 30 min, and the injector temperature and the starting temperature of gradient were set at 280 and 50 °C respectively. Acrolein was found in all tested samples, while acrylamide was detected only in smoke from normal tobacco. Possible mechanisms for the formation of these unsaturated compounds in the samples are discussed. After its validation the newly developed method was successfully and reliably applied to the analysis of both compounds. This short method provides an easy way to determine acrylamide and acrolein in gaseous samples.

  相似文献   

11.
12.
A number of molecular diagnostic methods have been developed for the detection and identification of mutations in tumor samples, which are important for the choice of treatment in the context of personalized medicine. For the treatment of metastatic melanoma, Vemurafenib is recommended for patients with BRAF V600 activating mutations. However, the different assays developed to date for the detection of these mutations lack sensitivity or specificity or do not allow a sequencing-based identification or validation of the mutation. Recently, enhanced improved and complete enrichment co-amplification at lower denaturation temperature-polymerase chain reaction (E-ice-COLD-PCR) has been developed as a sensitive method for the detection and identification of mutations in KRAS codons 12/13. Here, we present the first E-ice-COLD-PCR assay for the detection and identification of BRAF codon 600 mutations, which has a large dynamic range, as 25 pg to 25 ng can be used as DNA input without any reduction in mutation enrichment efficiency, and which can detect down to 0.01 % of mutated alleles in a wild-type background. The assay has been validated on fresh frozen, formalin-fixed paraffin-embedded (FFPE), and plasma samples of melanoma patients and has allowed the detection and identification of BRAF mutations present in samples appearing as wild type using standard pyrosequencing, endpoint genotyping, or Sanger sequencing. Thus, the BRAF V600 E-ice-COLD-PCR assay is currently one of the most powerful molecular diagnostic tools for the ultrasensitive detection and identification of BRAF codon 600 mutations.  相似文献   

13.
p-Aminothiophenol (pATP) functionalized multi-walled carbon nanotubes (MWCNTs) have been demonstrated as an efficient pH sensor for living cells. The proposed sensor employs gold/silver core-shell nanoparticles (Au@Ag NPs) functionalized MWCNTs hybrid structure as the surface-enhanced Raman scattering (SERS) substrate and pATP molecules as the SERS reporters, which possess a pH-dependent SERS performance. By using MWCNTs as the substrate to be in a state of aggregation, the pH sensing range could be extended to pH 3.0~14.0, which is much wider than that using unaggregated Au@Ag NPs without MWCNTs. Furthermore, the pH-sensitive performance was well retained in living cells with a low cytotoxicity. The developed SERS-active MWCNTs-based nanocomposite is expected to be an efficient intracellular pH sensor for bio-applications.  相似文献   

14.
In this study, Pt nanoparticles (NPs) were supported on reduced graphene oxide with the aid of disodium ethylenediamine-tetraacetate, where the Pt iona were initially attached to EDTA-functionalized graphene oxide (EDTA-GO) sheets and then the metal ion and the graphene oxide were reduced simultaneously by ethylene glycol. Electrochemical properties of the catalysts were studied by measuring cyclic voltammetries, and functional groups of the synthesized materials were investigated by Fourier transform infrared spectrometry. Average sizes and lattice parameters were measured by scanning electron microscopy, transmission electron microscopy images, and X-ray diffraction. The results showed that Pt NPs were successfully deposited on the EDTA-GO with the crystallite size of about 2.3 nm. The prepared catalysts demonstrated an enhanced tolerance towards CO poisoning, when EDTA-GO was used as supports. This suggests that EDTA plays a crucial role in the dispersion and electrocatalytic activity of the metal nanoparticles.  相似文献   

15.
MicroRNAs (miRNAs), a class of small endogenous nonprotein-coding RNAs, regulate a wide range of biological processes, and their abnormal expressions are related to the growth and development of plants. Thus, a simple, rapid, and highly sensitive assay for miRNA detection is of great significance. In this work, a label-free and ultrasensitive assay for miRNA detection using protein cage nanoparticles has been developed. Apoferritin-encapsulated Cu nanoparticles (Cu-apoferritin) could be immobilized on the electrode through special reaction between amino and carboxyl. Hybridization event between the probe DNA and the target miRNA-159a is confirmed by electrochemical oxidation signal after Cu released into the detection buffer by adjusting the pH. This assay is highly selective and sensitive with a low detection limit of 3.5 fM. Moreover, the developed method can even discriminate single-base mismatched strand between the complementary targets. The effect of abscisic acid on the expression level of miRNA-159a in Arabidopsis thaliana seeds was also investigated.  相似文献   

16.
A new nanoparticle formulation has been developed by using dimethyl-β-cyclodextrin (DM-β-CD) with raloxifene HCl or tamoxifene citrate. Both drugs are insoluble in water and represent as low bioavailibilities when given orally. Tamoxifen has an FDA approval for breast cancer prevention and the treatment. Raloxifene is approved for osteoprosis treatment. Both drugs were selected as a model drug antitumoural activity and MMP-2 inhibition studies were evaluated on breast cancer cell lines MCF-7 and MDA-MB 231. MMP-2 is known to be responsible for tumour invasion and initation the of angiogenesis. DM-β-CD and sodium taurocholate (NaTC) have been used as absorption enhancers to increase penetration effect of raloxifene/tamoxifen on the tumour cells and aimed to provide high antitumoral activity and MMP-2 inhibition results by developed nanoparticle formulations. The effects of two absorption enhancers were compared. The highest antitumoral activity was observed for DM-β-CD—raloxifene HCl nanoparticle formulation and also MMP-2 enzyme inhibit effectively.  相似文献   

17.
Tryptic digests were analyzed by means of online microbore liquid chromatography combined with mass spectrometry (LC/MS) for some common proteins. Following conventional enzymatic digestion with trypsin, the freeze-dried residues were dissolved in high-performance liquid chromatography (HPLC) eluent and subjected to gradient reversed-phase microbore HPLC separation with mass spectrometric detection. The latter was done in the full-scan single or tandem (MS/MS) mass spectrometry mode. The formation of gas-phase ions from dissolved analytes was accomplished at atmospheric pressure by pneumatically assisted electrospray (ion spray) ionization. This produced field-assisted ion evaporation of dissolved ions, which could then be mass-analyzed for molecular mass or structure. In the full-scan LC/MS mode, the masses for the peptide fragments in the tryptic digests can be determined as either their singly or multiply charged ions. When the molecular weights of the peptides lie outside the mass range of the mass spectrometer, the multiply charged feature of these experimental conditions still provides reliable molecular weight determinations. In addition, collision-activated dissociation (CAD) on selected peptide precursor ions provides online LC/MS/MS sequence information for the tryptic fragments. Results are shown for the tryptic digests of horse heart cytochrome c, bovine β-lactoglobulin A, and bovine β-lactoglobulin B.  相似文献   

18.
Lipophilic marine toxins are produced by harmful microalgae and can accumulate in edible filter feeders such as shellfish, leading to an introduction of toxins into the human food chain, causing different poisoning effects. During the last years, analytical methods, based on liquid chromatography coupled to tandem mass spectrometry (LC-MS/MS), have been consolidated by interlaboratory validations. However, the main drawback of LC-MS/MS methods remains the limited number of compounds that can be analyzed in a single run. Due to the targeted nature of these methods, only known toxins, previously considered during method optimization, will be detected. Therefore in this study, a method based on ultra-high-performance liquid chromatography coupled to high-resolution Orbitrap mass spectrometry (UHPLC-HR-Orbitrap MS) was developed. Its quantitative performance was evaluated for confirmatory analysis of regulated lipophilic marine toxins in shellfish flesh according to Commission Decision 2002/657/EC. Okadaic acid (OA), dinophysistoxin-1 (DTX-1), pectenotoxin-2 (PTX-2), azaspiracid-1 (AZA-1), yessotoxin (YTX), and 13-desmethyl spirolide C (SPX-1) were quantified using matrix-matched calibration curves (MMS). For all compounds, the reproducibility ranged from 2.9 to 4.9 %, repeatability from 2.9 to 4.9 %, and recoveries from 82.9 to 113 % at the three different spiked levels. In addition, confirmatory identification of the compounds was effectively performed by the presence of a second diagnostic ion (13C). In conclusion, UHPLC-HR-Orbitrap MS permitted more accurate and faster detection of the target toxins than previously described LC-MS/MS methods. Furthermore, HRMS allows to retrospectively screen for many analogues and metabolites using its full-scan capabilities but also untargeted screening through the use of metabolomics software. Figure
?  相似文献   

19.
In the development of nanoparticle-based vaccine adjuvants, the interaction between nanoparticles (NPs) and the cells is a key factor. To control them, we focused on the relationship between the hydrophobicity of the side chains and the cell membrane. In this study, amphiphilic poly(γ-glutamic acid) (γ-PGA), using various types of hydrophobic side chains, was synthesized and used to prepare NPs for evaluating the membrane disruptive activity. When leucine ethyl ester (Leu), methionine ethyl ester (Met), or tryptophan ethyl ester (Trp) was grafted, each polymer formed monodispersed NPs at physiological conditions. Significantly, NPs composed of Leu and Trp showed a membrane disruptive activity at the endosomal environment (pH 5–6.5), while NPs composed of Met did not show. This might be due to the weak hydrophobicity of Met compared to that of Leu and Trp, which demonstrated that the interaction between NPs and cells could be controlled by designing the polymer compositions.  相似文献   

20.
To investigate the effect of surface functionality on the morphology of polymer/silica composite, poly(styrene-alt-maleic anhydride) (SMA) spheres prepared via precipitation polymerization method was employed. In water/ethanol solution, diethanolamine (DEA) was used to catalyze the hydrolysis reaction of tetraethoxysilane (TEOS), and rambutan-like poly(styrene-alt-maleic anhydride)/silica (SMA/SiO2) microspheres were synthesized through in situ sol–gel process. The obtained structure and morphology were characterized by FTIR, NMR, TEM, SEM, and TGA. The results showed that the hydrolyzed SMA chains on the surface was crucial to the nucleation and growth of silica, and the morphologies of SMA/SiO2 composite microspheres can be controlled by the amount of DEA and the ratio of SMA/TEOS. In addition, the SMA/SiO2 microspheres were used to prepare hierarchical structure of SMA/SiO2/Ag particles, which were utilized for the construction of surface-enhanced Raman scattering substrate (SERS).  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号