首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 49 毫秒
1.
Separation of six vitamers of vitamin B6 was performed by RP-HPLC using micellar mobile phase, UV and electrochemical detection. Effect of temperature, type and amount of organic modifier in mobile phase on efficiency and asymmetry factor showed that, the appropriate conditions were temperature of 35 degrees C and 3.0-5.0% (v/v) 1-butanol in mobile phase. Variations of selectivity factor versus 1-butanol concentration, pH of mobile phase, and SDS concentration was investigated and the following optimized conditions were selected for the separation: 3.0% (v/v) 1-butanol, pH=5.5 and 65 mM SDS in mobile phase. Electrochemical behavior of vitamers in optimized mobile phase was investigated using cyclic voltammetry, and potential of +1.2 V versus Ag/AgCl(Sat.) was chose as working potential. Finally, separation of B6 vitamers using UV detection at 254 nm and electrochemical detection at +1.2 V was compared.  相似文献   

2.
The retention behaviour of thiazolylazo derivatives, 4-(2-thiazolylazo) resorcinol (TAR), 4-(2-thiazolylazo)-orcinol (TAO), 2-(2-thiazolylazo)-4-methylphenol (TAC) and 1-(2-thiazolylazo)-2-naphtol (TAN) was studied by reversed phase liquid chromatography. The optimum conditions for the separation of four thiazolylazo derivatives were examined with respect to column, flow rate, mobile phase composition and pH of mobile phase. These derivatives were separated simultaneously on Symmetry C8 column using composition of acetonitrile/water (60/40, v/v) as mobile phase. The capacity factor (k′) has been decreased at higher pH than pKa of solute which may due to the increasing concentration of the ionized species as increase the pH of mobile phase. The dependence of log k′ on the volume faction of water in the binary mobile phase and k′ on the liquid–liquid extraction distribution ratio (Dc) in acetonitrile–water (60/40, v/v)/n-octane extraction system for thiazolylazo derivatives were obtained good linear relationship. The results showed that the retention behaviour of these derivatives was mainly affected by the hydrophobic interaction between thiazolylazo as solute and mobile phase.  相似文献   

3.
Under reversed-phase high-performance liquid chromatographic conditions [Spherisorb ODS 1 stationary phase, UV detection at 254 nm, and acetonitrile-dichloromethane-acetic acid-methyl-tert-butylether (84.6/4.5/0.9/10, v/v/v/v) as the mobile phase], adding p-tert-butylcalix[8] (10(-5)-3.10(-5))-[12]arenes (10(-5)-4.10(-5) mol/L) to the mobile phase leads to decreased sorption of aromatic solutes on the surface of the sorbent because of the formation of host-guest inclusion complexes between the calixarenes and the aromatic molecules. Stability constants of the complexes (781-9338M(-1)) are determined from the relationship between the solute capacity factors and the calixarene concentration in the mobile phase.  相似文献   

4.
Jiang M  Qin F  Xiong Z  Zhang S  Pan L  Li F 《色谱》2011,29(11):1137-1140
以纤维素三-(3,5-二甲基苯基氨基甲酸酯)为手性固定相(Lux Cellulose-1),建立了在正相色谱条件下直接分离盐酸川丁特罗对映体的高效液相色谱法。考察了乙醇、异丙醇等有机改性剂,三氟乙酸、二乙胺等流动相添加剂和柱温对对映体分离的影响。结果显示,酸性和碱性添加剂对对映体分离的影响最为显著: 添加二乙胺时两对映体无分离趋势;添加三氟乙酸时对映体保留强,且分离趋势明显;而同时添加三氟乙酸和二乙胺则两对映体分离显著改善,分离度可达4.0。优化后的色谱条件: 色谱柱为Lux Cellulose-1手性柱(250 mm×4.6 mm, 5 μm),流动相为正庚烷-乙醇-三氟乙酸-二乙胺(88:12:0.3:0.05, v/v/v/v),流速为1.0 mL/min,紫外检测波长为246 nm,柱温为25 ℃。该方法简便,快速,可用于左旋盐酸川丁特罗原料中右旋异构体杂质的检查。  相似文献   

5.
Chromatographic properties of five steroid drugs: cortisone, hydrocortisone, methylprednisolone, prednisolone and norgestrel have been studied by normal-, reversed-phase and hydrophilic neutral cyano-bonded silica stationary phase with five binary mobile phases (acetonitrile-water, acetonitrile-DMSO, acetonitrile-methanol, acetone-petroleum ether, acetone-water) in which the concentration of organic modifier was varied from 0 to 100% (v/v). This study reports the optimization of steroid hormones separation. Chromatographic retention data and possible retention mechanisms are discussed. Separation abilities of mobile and stationary phases were studied using the principal component analysis method. The best separation of methylprednisolone and prednisolone is with a chromatographic system included silica gel as stationary phase and mixture of acetonitrile and DMSO (10:90 v/v). These two anti-inflammatory drugs can be fast separated from norgestrel when CN is used as stationary phase and acetone and water (40:60 v/v) as mobile phase. The highest values of the parameter Δ(ΔG°) and alfa for cortisone and hydrocortisone was observed in case of using CN as stationary phase and water-acetonitryle (40:60 v/v) as mobile phase.   相似文献   

6.
Plots of the retention factor against mobile phase composition were used to organize a varied group of solutes into three categories according to their retention mechanism on an octadecylsiloxane-bonded silica stationary phase HyPURITY C18 with methanol-water and acetonitrile-water mobile phase compositions containing 10-70% (v/v) organic solvent. The solutes in category 1 could be fit to a general retention model, Eq. (2), and exhibited normal retention behavior for the full composition range. The solutes in category 2 exhibited normal retention behavior at high organic solvent composition with a discontinuity at low organic solvent compositions. The solutes in category 3 exhibited a pronounced step or plateau in the middle region of the retention plots with a retention mechanism similar to category 1 solutes at mobile phase compositions after the discontinuity and a different retention mechanism before the discontinuity. Selecting solutes and appropriate composition ranges from the three categories where a single retention mechanism was operative allowed modeling of the experimental retention factors using the solvation parameter model. These models were then used to predict retention factors for solutes not included in the models. The overwhelming number of residual values [log k (experimental) - log k (model predicted)] were negative and could be explained by contributions from steric repulsion, defined as the inability of the solute to insert itself fully into the stationary phase because of its bulkiness (i.e., volume and/or shape). Steric repulsion is shown to strongly depend on the mobile phase composition and was more significant for mobile phases with a low volume fraction of organic solvent in general and for mobile phases containing methanol rather than acetonitrile. For mobile phases containing less than about 20 % (v/v) organic solvent the mobile phase was unable to completely wet the stationary phase resulting in a significant change in the phase ratio and for acetonitrile (but less so methanol) changes in the solvation environment indicated by a discontinuity in the system maps.  相似文献   

7.
This paper describes two simple, specific, accurate, and precise methods for estimation of olopatadine hydrochloride (OLO) in tablet dosage form. The first method is a stability-indicating isocratic RP-HPLC method. The analysis is performed on an RP-18 column using 0.1% orthophosphoric acid (adjusted to pH 4.5 with triethylamine)-acetonitrile (75 + 25, v/v) mobile phase at a flow rate of 1 mL/min. Paracetamol (PAR) was selected as the internal standard. Retention times of OLO and PAR were 11.30 +/- 0.02 and 4.70 +/- 0.03 min, respectively. For the HPTLC method, precoated silica gel 60 F254 aluminum sheets were used as the stationary phase; the mobile phase was methanol-chloroform-ammonia (8 + 2 + 0.1, v/v/v). The detection of the analyte band was carried out at 301 nm, and its Rf value was 0.46 +/- 0.03. The analytical methods were validated according to International Conference on Harmonization guidelines. Linear regression analysis data for the calibration plots showed a good linear relationship between response and concentration in the range of 0.1-1 microg/mL and 0.1-0.9 microg/band for HPLC and HPTLC, respectively.  相似文献   

8.
Three groups of structurally diverse chiral compounds were used to study the interaction mechanism responsible for stereoselective recognition with teicoplanin as chiral selector in capillary liquid chromatography. Teicoplanin-based chiral stationary phase (CSP) was used. The effect of the variation of mobile phase composition on retention and enantioselective separation was studied. The mobile phase composition suitable for enantioresolution of the various chiral compounds differed according to the interaction forces needed for chiral recognition. Mobile phases with high buffer portion (70-90 vol.%) were preferred for separation of enantiomers of profen non-steroidal anti-inflammatory drugs and chlorophenoxypropionic acid herbicides that require hydrophobic interactions, inclusion and pi-pi interactions for stereoselective recognition with teicoplanin. Higher concentration triethylamine in the buffer (0.5-1.0%) increased resolution of these acids. On the other hand, H-bonding and electrostatic interactions are important in stereoselective interaction mechanism of beta-adrenergic antagonists with teicoplanin. These interaction types predominate in the reversed phase separation mode with high organic modifier content (95% methanol) and in polar organic mobile phases. For this reason beta-adrenergic antagonists were best enantioresolved in the polar organic mode. The mobile phase composed of methanol/acetic acid/triethylamine, 100/0.01/0.01 (v/v/v), provided enantioresolution values of all the studied beta-adrenergic antagonists in the range 1.1-1.9. Addition of teicoplanin to the mobile phase, which was suitable for enantioseparation of certain compounds on the CSP, was also investigated. This system was used to dispose of nonstereoselective interactions of analytes with silica gel support that often participate in the interaction with CSPs. Very low concentration of teicoplanin in the mobile phase (0.1 mM) resulted in enantioselective separation of 2,2- and 2,4-chlorophenoxypropionic acids.  相似文献   

9.
Resolution of the enantiomers of (+/-)-econazole, (+/-)-miconazole, and (+/-)-sulconazole has been achieved on different normal-phase chiral amylose columns, Chi-ralpak AD, AS, and AR. The mobile phase used was hexane-2-propanol-diethylamine, 400:99:1 (v/v). The flow rates of the mobile phase used were 0.50 and 1.00 mL min(-1). The alpha values for the resolved enantiomers of econazole, miconazole, and sulconazole on the chiral phases were in the range 1.63 to 1.04; the Rs values varied from 5.68 to 0.32.  相似文献   

10.
The chromatographic behaviors of some basic solutes were evaluated on stationary phases based on poly(methyloctylsiloxane) immobilized onto silica (PMOS-SiO(2)). The test solutes present both hydrophobic and hydrophilic properties. Evaluations of the pH effect used 80:20 v/v methanol/buffered mobile phase over the pH range of 5-11.5 with inorganic buffers such as borate, carbonate and phosphate and with organic buffers such as citrate, tricine and triethylamine. Evaluations in acidic mobile phases used 50:50 v/v and 30:70 v/v methanol/buffer (pH 2.5; 20 mmol/L) mobile phases. The buffer concentration effect used 65:35 v/v methanol/phosphate (pH 7; 20 and 100 mmol/L) mobile phases. The results are compared with those obtained with two chemically bonded stationary phases. The immobilized phases show greater contributions from an ion-exchange mechanism than do the commercial phases. The results indicate that the silanol activity of PMOS-SiO(2) stationary phases can be adequately evaluated by using appropriate basic probes and mobile phases having different pH, using different buffers.  相似文献   

11.
A high-performance liquid chromatographic method involving post-column photochemical reaction and fluorimetric detection has been developed for the determination of kynurenine in serum. Kynurenine was separated on a column of Capcell Pak C18 (resistant to pH 10). The mobile phase consisted of 0.05 M Na2B4O7-0.1 M KH2PO4 buffer (pH 8.5)-ethanol (97:3, v/v) containing 60 mM hydrogen peroxide. The post-column reagent, containing 60% (v/v) ethanol, was mixed with the mobile phase, which was irradiated with ultraviolet light to induce fluorescence. The recovery of kynurenine was 95.9 +/- 5.0% (n = 6). The method allows the determination of as little as 2 pmol of kynurenine.  相似文献   

12.
Gu Q  Shi X  Yin P  Gao P  Lu X  Xu G 《Analytica chimica acta》2008,609(2):192-200
Two simple, rapid and specific analytical methods for 13 catecholamines and their metabolites have been developed based on liquid chromatography tandem mass spectrometry in a multiple reaction monitoring mode. Tyrosine, dopamine, dihydroxyphenylalanine, epinephrine, norepinephrine, 3-methoxytyramine, normetanephrine, metanephrine and isoproterenol (internal standard) were separated on a Kromasil™ Cyano analytical column by a mobile phase consisting of 60% (v/v) acetonitrile and 40% (v/v) water adjusted with formic acid to pH 3.0, and detected by positive ionization electrospray tandem mass spectrometry. While vanillymandelic acid, 3,4-dihydroxymandelic acid, homovanillic acid, 3,4-dihydroxyphenylacetic acid, 4-hydroxy-3-methoxyphenylglycol and 5-hydroxy-2-indolecarboxylic acid (internal standard) were separated on a reversed-phase Shim-Pak VP-ODS column with the mobile phase of 60% (v/v) acetonitrile, and 40% (v/v) water adjusted with formic acid to pH 4.5 and detected in the negative ionization electrospray tandem mass spectrometry. The influence of various parameters such as column type and mobile phase composition on separation and sensitivity were investigated. The limits of detection were in the range of 0.5-20 ng mL−1. The mean recoveries determined from three different concentrations of each analyte were above 85.4%. The precision of the method calculated as relative standard deviation was lower than 5.3%. Deduced from the results of real sample analysis, adrenal gland synthesizes and stores the catecholamine hormones norepinephrine and epinephrine.  相似文献   

13.
The separation of tetracycline and amino glycopeptide antibiotics was achieved on silica gel thin layers. Tetracycline antibiotics were resolved on a Co+2 (1.0%) impregnated silica gel layer using ethanol:acetic acid:water (10:6:6, v/v/v) as the mobile phase. Amino glycopeptide antibiotics were separated on an untreated silica gel layer using the mobile phase n-butanol:formic acid:water (6:5:7, v/v/v). The spots of these antibiotics were located by exposing the chromatoplate to iodine vapours.  相似文献   

14.
Two sensitive and reproducible methods were developed and validated for the determination of ziprasidone (ZIP) in the presence of its degradation products in pure form and in pharmaceutical formulations. The fi rst method was based on reversed-phase high-performance liquid chromatography (HPLC), on a Lichrosorb RP C(18) column using water:acetonitrile:phosphoric acid (76:24:0.5 v/v/v) as the mobile phase at a fl ow rate of 1.5 mL min(-1) at ambient temperature. Quantification was achieved with UV detection at 229 nm over a concentration range of 10-500 micro g mL(-1) with mean percentage recovery of 99.71 +/- 0.55. The method retained its accuracy in presence of up to 90% of ZIP degradation products. The second method was based on TLC separation of ZIP from its degradation products followed by densitometric measurement of the intact drug spot at 247 nm. The separation was carried out on aluminium sheet of silica gel 60 F(254) using choloroform:methanol:glacial acetic acid (75:5:4.5 v/v/v) as the mobile phase, over a concentration range of 1-10 micro g per spot and mean percentage recovery of 99.26 +/- 0.39. Both methods were applied successfully to laboratory prepared mixtures and pharmaceutical capsules.  相似文献   

15.
The influence of different solvents on the extraction medium and the RP-HPLC mobile phase composition were investigated by statistical mixture designs to optimize solvent proportions to prepare the fingerprint of a medicinal herbal extract. For modeling, the number of peaks was used as a measure of fingerprint information. The optimum compositions of solvent to extract chemical substances from green tea and for mobile phase chromatographic analysis were ethyl acetate/ ethanol/dichloromethane (20:5:75 v/v/v) and MeOH/ACN/water (7.5:57.5:35 v/v/v), respectively. This system results in 26 peaks in the chromatographic fingerprint. These results show that an incorrect choice of modifiers for mobile phase composition and solvent extraction hampers the detection of a maximum number of peaks and produces a poor chromatographic fingerprint.  相似文献   

16.
A super-modified simplex (SMS) method has been used to optimize the mobile phase used for separation of seven water-soluble vitamins in multivitamin tablets by gradient micellar liquid chromatography (MLC) with ultraviolet (UV) detection at 254, 295, and 361 nm. Effect of column temperature and addition of organic modifier to the mobile phase on separation efficiency were investigated: the appropriate conditions used were a temperature of 35 degrees C and 1-butanol modifier. The sodium dodecyl sulfate (SDS) concentration, pH, and 1-butanol% in the mobile phase were chosen for simultaneous optimization using the SMS method. The optimum mobile phase was found to be 16 mmol L(-1) (mM) SDS, 0.02 M phosphate buffer, pH 3.6, and a gradient of 3.5-10% (v/v) butanol. The total analysis time for vitamins was 75 min. The analytical parameters including linearity ( r>0.9970), limit of detection (0.12-50 micro g mL(-1)), precision of method (relative standard deviation (RSD) <8.90%), and accuracy obtained by the recovery assay (88-103%) support the usefulness of the proposed method for the determination of the water-soluble vitamins.  相似文献   

17.
A reliable and specific method for the determination of citalopram enantiomers was developed and validated. Chromatographic resolution of citalopram enantiomers was made on a Shim-pack (5 microm particle size) cyanopropyl column with beta-cyclodextrin (beta-CD) as an effective chiral mobile phase additive. The composition of the mobile phase was (90 + 10, v/v) aqueous 0.1% triethylammonium acetate buffer, pH 4.0 (adjusted with acetic acid), and acetonitrile, containing 12 mM beta-CD. The flow rate was 0.8 mL/min with ultraviolet detection at 240 nm. The effects of the mobile phase composition, concentration of beta-CD, and pH of the triethylammonium acetate buffer on peak shape and resolution of the enantiomers were investigated. The calibration graphs were linear (r = 0.9999, n = 8) in the range of 1-40 microg/mL for S(+) citalopram and R-(-) citalopram. The limit of detection values were 5.51 x 10(-3) and 4.35 x 10(-3) pg/mL, while the limit of quantification values were found to be 1.84 x 10(-2) and 1.45 x 10(-2) microg/mL for S-(+) citalopram and R-(-) citalopram, respectively.  相似文献   

18.
A cellulose tris‐(3,5‐dimethylphenylcarbamate)‐based chiral stationary phase was studied as a tool for the enantioselective separation of 21 selected analytes with different pharmaceutical and physicochemical properties. The enantioseparations were performed using supercritical fluid chromatography. The effect of the mobile phase composition was studied. Four different additives (diethylamine, triethylamine, isopropylamine, and trifluoroacetic acid) and isopropylamine combined with trifluoroacetic acid were tested and their influence on enantioseparation was compared. The influence of two different mobile phase co‐solvents (methanol and propan‐2‐ol) combined with all the additives was also evaluated. The best mobile phase compositions for the separation of the majority of enantiomers were CO2/methanol/isopropylamine 80:20:0.1 v/v/v or CO2/propan‐2‐ol/isopropylamine/trifluoroacetic acid 80:20:0.05:0.05 v/v/v/v. The best results were obtained from the group of basic β‐blockers. A high‐performance liquid chromatography separation system composed of the same stationary phase and mobile phase of similar properties prepared as a mixture of hexane/propan‐2‐ol/additive 80:20:0.1 v/v/v was considered for comparison. Supercritical fluid chromatography was found to yield better results, i.e. better enantioresolution for shorter analysis times than high‐performance liquid chromatography. However, examples of enantiomers better resolved under the optimized conditions in high‐performance liquid chromatography were also found.  相似文献   

19.
Summary The solvation parameter model is used to characterize the retention properties of a cyanopropylsiloxanebonded, silica-based sorbent with methanol, acetonitrile, tetrahydrofuran, and isopropanol in water as mobile phases. The system constants over the composition range 1 to 50 % (v/v) organic solvent indicate that retention occurs because of the relative ease of cavity formation in the solvated stationary phase compared to the same process in the predominantly aqueous mobile phase as well as from more favorable stationary phase interactions with solutes containing π- and n-electrons. The capacity of the solute for dipole-type interactions is not important whereas all hydrogen-bond-type interactions result in reduced retention. Graphing the system constants as a function of mobile phase composition provides a simple mechanism for interpreting the change in capacity of the chromatographic system for retention in terms of changes in the relative weighting of fundamental intermolecular interactions. A comparison is also made with the retention properties of an octadecylsiloxane-bonded, silica-based sorbent with 30 % (v/v) methanol in water as the mobile phase and the extraction characteristics of a porous polymer sorbent with 1 % (v/v) methanol, acetonitrile, tetrahydrofuran, and isopropanol in water as the sample processing solvent. Changes in sorbent selectivity due to selective uptake of the processing solvent are much smaller for the cyanopropylsiloxane-bonded sorbent than the results found for a porous polymer sorbent.  相似文献   

20.
For the determination of khellin in urine and serum, fluorometry using HPLC-postcolumn photoirradiation has been developed. Khellin and visnagin of similar structure were separated on a column of Capcell Pak C8. The mobile phase consisted of 40%(v/v) ethanol containing 75 mmol l(-1) H2O2. The postcolumn reagent, 70 mmol l(-1) KH2PO4-NaOH buffer (pH 12.7) containing 50%(v/v) ethanol, were mixed with the mobile phase, which was irradiated with ultraviolet light to induce fluorescence. The fluorescence was monitored with excitation at 378 nm and emission at 480 nm. The calibration graph for khellin was linear over the range of 65 - 2620 ng ml(-1) using an injection volume of 20 microl. The pretreatment of the urine or serum samples consisted of diluting steps or deproteinizing steps using perchloric acid, respectively.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号