首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Rapid and efficient enantioseparation of halogen aryl alcohols and β‐blockers propranolol and pindolol in packed bed CEC (p‐CEC) using as‐prepared submicron porous silica chiral stationary phases (CSPs) has been achieved. Monodispersed 0.66 and 0.81 μm chiral submicron porous silica spheres were prepared using tetramethoxysilane and hexadecyltrimethylammonium bromide, followed by a hydrothermal treatment method with ammonia–ethanol to expand the pore of silica spheres without changing their spherical morphology. A proper specific surface of ca. 230 m2/g and pore sizes average of 6–8 nm were obtained by this method. The submicron porous silica spheres were modified with mono‐6‐phenylcarbamoylated β‐CD via thiol‐en radical addition. They were packed into 9 cm 50 μm id capillary columns with photopolymerized monolithic frits. These submicron CSPs showed greater column efficiency (about 476 000 plates/m for 4‐iodophenyl‐1‐ethanol) and higher resolution than the corresponding 3 μm CSP.  相似文献   

2.
Cellulose tris(3,5-dimethylphenylcarbamate) (CDMPC) is an excellent chiral selector for enantioseparation of a wide variety of chiral compounds. The monolithic chiral columns are becoming popular in liquid chromatography and capillary electrochromatography. In this work, we present the fast separation of chiral β-blockers on a CDMPC-modified zirconia monolithic column by capillary electrochromatography (CEC). The porous zirconia monolithic capillary column was prepared by using the sol-gel technology and then zirconia surface modified with CDMPC. The enantioseparations were performed in reversed-phase (RP) eluents of a phosphate solution (pH 4.4) modified with acetonitrile or alcohol. The enantioseparations of a set of eight chiral β-blockers were achieved in less than one minute. Influences of the applied voltage, column temperature, concentration of acetonitrile and the type of alcohol as the organic modifier in the mobile phase, and sample injection time on enantioseparation were investigated. CEC separations at the applied voltage of 10 kV and 15 °C in the ACN-modified mobile phase provided the best resolutions for the analytes studied. Run-to-run and day-to-day repeatabilities of the column in the RP-CEC separation were less than 1 and 2%, respectively.  相似文献   

3.
A range of porous carbon‐based monolithic (PCM) rods with flow‐through pore sizes of 1, 2, 5 and 10 μm, were produced using a silica particle template method. The rods were characterised using SEM and energy‐dispersive X‐ray spectroscopy, BET surface area and porous structure analysis, dilatometry and thermal gravimetry. SEM evaluation of the carbon monolithic structures revealed an interconnected rigid bimodal porous structure and energy‐dispersive X‐ray spectroscopy analysis verified the quantitative removal of the embedded silica beads. The specific surface areas of the 1, 2, 5 and 10 μm rods were 178, 154, 84 and 125 m2/g after pyrolysis and silica removal, respectively. Shrinkage of the monolithic rods during pyrolysis is proportional to the particle size of the silica used and ranged from 9 to 12%. Mercury porosimetry showed a narrow distribution of pore sizes, with an average of ~700 nm for the 1 μm carbon monolith. The suitability of bare and surface oxidised PCM rods for the use as a stationary phase for reversed and normal phase LC was explored. The additional modification of PCM rods with gold micro‐particles followed by 6‐mercaptohexanoic acid was performed and ion‐exchange properties were evaluated.  相似文献   

4.
采用无搅动原位聚合模式,在聚醚醚酮柱管中直接制备了聚合物整体固定相。通过扫描电镜观察到该整体固定相的孔径分布呈双峰模式,且孔结构均匀。用压汞法测定了该固定相的孔径分布、孔隙率及比表面积等参数,考察了致孔剂组成、聚合温度及交联剂含量等参数对固定相孔结构的影响,并对制备条件进行了优化。测定了流速与柱前压的关系,实验表明此整体固定相具有良好的通透性。通过对山羊血清和低聚核苷酸的分离分析,证明了所制备的整体固定相适合用于生物大分子的分离纯化。  相似文献   

5.
Capillary columns with monolithic stationary phase were prepared from silanized fused-silica capillaries of 75 microns I.D. by in situ copolymerization of divinylbenzene either with styrene or vinylbenzyl chloride in the presence of a suitable porogen. The porous monolithic support in this study was used either directly or upon functionalization of the surface to obtain a stationary phase that was appropriate for the separation of peptides by capillary electrochromatography (CEC). The main advantages of monolithic columns are as follows. They do not need retaining frits, they do not have charged particles that can get dislodged in high electric field, and they have relatively high permeability and stability. Whereas such columns are designed especially for CEC, they find application in micro high-performance liquid chromatography (mu-HPLC) as well. Five different porogens were employed to prepare the monolithic columns that were examined for permeability and porosity. The flexibility of fused-silica capillaries was not adversely affected by the monolithic packing and the longevity of the columns was satisfactory. This may also be due to the polymerization technique, which resulted in a fluid-impervious outer layer of the monolith that precluded contact between the fused-silica surface and the liquid mobile phase. For the most promising columns, the conductivity ratios and the parameters of the simplified van Deemter equation, both in mu-HPLC and CEC, were evaluated. It was found that the efficiency of the monolithic columns in CEC was significantly higher than in mu-HPLC in the same way as observed with capillary columns having conventional particulate packing. This is attributed to the relaxation of band-broadening with electroosmotic flow (EOF) with respect to that with viscous flow. It follows then that the requirement of high packing uniformity to obtain high efficiency may also be relaxed in CEC. Angiotensin-type peptides were separated by CEC with columns packed with a monolithic stationary phase having fixed n-octyl chains and quaternary ammonium groups at the surface. Plate heights of about 8 microns were routinely obtained. The mechanism of the separation is based on the interplay between EOF, chromatographic retention and electrophoretic migration of the positively charged peptides. The results of the complex migration process, with highly nonlinear dependence of the migration times on the organic modifier and the salt concentration, cannot be interpreted within the framework of classical chromatography or electrophoresis.  相似文献   

6.
Preparation of monolithic capillary columns for separations in the CEC mode using UV-initiated polymerization of the plain monolith followed by functionalization of its pore surface by photografting has been studied. The first step enabled the preparation of generic poly(butyl methacrylate-co-ethylene dimethacrylate) monoliths with optimized porous properties, controlled by the percentages of porogens 1-decanol and cyclohexanol in the polymerization mixture, irradiation time, and UV light intensity. Ionizable monomers [2-(methacryloyloxy)ethyl]trimethylammonium chloride or 2-acryloamido-2-methyl-1-propanesulfonic acid were then photografted onto the monolithic matrix, allowing us to control the direction of the EOF in CEC. Different strategies were applied to control the grafting density and, thereby, the magnitude of the EOF. To control the hydrophobic properties, two approaches were tested: (i) cografting of a mixture of the ionizable and hydrophobic monomers and (ii) sequential grafting of the ionizable and hydrophobic monomers. Cografting resulted in similar retention but higher EOF. With sequential grafting, more than 50% increase in retention factors was obtained and a slight decrease in EOF was observed due to shielding of the ionizable moieties.  相似文献   

7.
The separation and determination of tocopherols (Ts) in vegetable oils by CEC using methacrylate ester-based monolithic columns has been developed. The effects of pore size of the monolithic columns were studied, and the composition of mobile phase was optimized. The optimal pore size of the monolith was obtained with 12 wt% 1,4-butanediol in the polymerization mixture. Excellent resolution between tocopherols was achieved within 10 min analysis time with a 99:1 v/v MeOH-aqueous buffer containing 5 mM tris(hydroxymethyl)aminomethane at pH 8.0. The LODs were lower than 2.3 microg/mL, and interday and column-to-column reproducibilities at 25 microg/mL were better than 5.6%. Using a 93:7 v/v MeOH-aqueous buffer, both tocopherols and tocotrienols (T(3)s) of grapeseed and palm oils were resolved. Application to the detection of olive oil adulteration with low-cost edible oils was demonstrated.  相似文献   

8.
Wistuba D  Schurig V 《Electrophoresis》2000,21(18):4136-4158
Enantiomer separation by electrochromatography (CEC) can be performed in three modes: (i) open-tubular capillary electrochromatography (o-CEC), in which the chiral selector is physically adsorbed coated, and thermally immobilized or covalently attached to the internal capillary wall; (ii) packed capillary electrochromatography (p-CEC), in which the capillary is either filled with chiral modified silica particles or with an achiral packing material, and a chiral selector is added to the mobile phase; and (iii) monolithic (rod)-capillary electrochromatography (rod-CEC) in which the chiral stationary phase (CSP) consists of a single piece of porous solid. We present an overview on methods and new trends in the field of electrochromatographic enantiomer separation such as CEC with either nonaqueous mobile phases or stationary phases with incorporated permanent charges, or with packing beds consisting of nonporous silica particles or particles with very small internal diameters.  相似文献   

9.
In this paper, a novel highly cross‐linked porous monolithic stationary phase having a long alkyl chain ligand (C16) was introduced and evaluated in CEC. The monolithic stationary phase was prepared by in situ copolymerization of 1‐hexadecene, trimethylolpropane trimethacrylate, and 2‐acrylamido‐2‐methyl‐1‐propanesulfonic acid (AMPS) in the presence of ternary porogenic solvent (cyclohexanol/1,4‐butanediol/water). In preparing monoliths, the ternary cross‐linker trimethylolpropane trimethacrylate was usually applied to preparing molecularly imprinted polymers or molecularly imprinted solid‐phase extraction, instead of binary cross‐linker ethylene dimethacrylate. 1‐Hexadecene was introduced to provide the non‐polar sites (C16) for chromatographic retention, while AMPS was used to generate the EOF for transporting the mobile phase through the monolithic capillary. Monolithic columns were prepared by optimizing proportion of porogenic solvent and AMPS content in the polymerization solution as well as the cross‐linkers. The monolithic stationary phases could generate a strong and stable EOF in various pH values and exhibit an RP‐chromatographic behavior for neutral compounds. For charged compounds, the separation was mainly based on the association of hydrophobic, electrostatic and electrophoretic interaction.  相似文献   

10.
Eeltink S  Svec F  Fréchet JM 《Electrophoresis》2006,27(21):4249-4256
Open-tubular columns for CEC separations having inner-wall coated with a thin layer of porous monolithic polymer have been studied. A two-step process including (i) UV-initiated polymerization leading to a layer of porous poly(butyl methacrylate-co-ethylene dimethacrylate), and (ii) UV-initiated grafting of ionizable monomers appear to be well suited for the preparation of these columns. The thickness of the porous polymer layer is controlled by the percentage of monomers in the polymerization mixture and/or length of the irradiation time. The layer thickness significantly affects retention, efficiency, and resolution in open-tubular CEC. Under optimized conditions, column efficiencies up to 400,000 plates/m can be achieved. Use of higher temperature and application of pressure enables a significant acceleration of the open-tubular CEC separations.  相似文献   

11.
Hilder EF  Svec F  Fréchet JM 《Electrophoresis》2002,23(22-23):3934-3953
This review summarizes the contributions of a number of groups working in the rapidly growing area of monolithic columns for capillary electrochromatography (CEC), with a focus on those prepared from synthetic polymers. Monoliths have quickly become a well-established stationary phase format in the field of CEC. The simplicity of their in situ preparation method as well as the good control over their porous properties and surface chemistries make the monolithic separation media an attractive alternative to capillary columns packed with particulate materials. A wide variety of approaches as well as materials used for the preparation of the monolithic stationary phases are detailed. Their excellent chromatographic performance is demonstrated by numerous separations of different analytes.  相似文献   

12.
A novel solid phase extraction microchip with a boronic acid functional affinity monolithic disc was developed in this work. Vinyl phenylboronic acid–ethylene glycol dimethacrylate co-polymer monoliths, which have pore sizes up to 20 μm, were investigated for extraction of catecholamines using adsorption and desorption studies in a batch system. Desorption yields of greater than 90% were achieved for catecholamines at pH 3 and below. Monolithic discs were then formed in chambers in borofloat glass microfluidic chips using in situ UV polymerization. Adsorption on the monolithic discs was performed via electrokinetic flow, with catecholamines determined via laser-induced native fluorescence (LINF) detection following electrokinetic elution. Microchips containing the boronic acid functional polymer discs worked well for extraction of catecholamines, providing greater than 100 fold concentration enrichment. This study demonstrated that a solid phase extraction microchip, containing an easily prepared monolith disc, will be useful for boronate affinity extraction of cis-diol containing compounds.  相似文献   

13.
Fused-silica capillary columns (100 μm I.D.) englobing a porous monolithic stationary phase were prepared by in situ copolymerization of 2-ethylhexyl methacrylate, ethylene glycol dimethacrylate and 2-acrylamido-2-methylpropanesulfonic acid (AMPS) in the presence of a porogenic mixture containing 1-propanol, 1,4 butanediol and water. The influence of the monomers ratio and the porogen solvent composition as well as the content of AMPS in the polymerization mixture on column total porosity and efficiency was investigated to attain minimum HETP values for the reversed-phase capillary electrochromatography separation of bioflavonoids. For the most promising column, the van Deemter plots, in both μ-HPLC and CEC, were also evaluated. In CEC the reduced plate height was found almost constant (1.6–2.0) within the range of linear mobile phase velocity between 0.2–2.0 mm s−1. The chemical and mechanical stabilities of the monolithic column over a wide range of buffer pH (2-10) and time were satisfactory. Furthermore, the effects of mobile phase parameters, such as buffer concentration and organic modifier content, on the electroosmotic flow were studied systematically. CEC separations of standard mixtures of polyphenols, including flavonols, flavanones and flavanones-7-O-glycosides, were accomplished in less than 8 min. The CEC separation of the major flavanone glycoside constituents in the extract from a freshly squeezed grapefruit juice was also reported.  相似文献   

14.
Rigid porous polymer monoliths are a new class of materials that emerged in the early 1990s. These monolithic materials are typically prepared using a simple molding process carried out within the confines of a closed mold. For example, polymerization of a mixture comprising monomers, free-radical initiator, and porogenic solvent affords macroporous materials with large through-pores that enable applications in a rapid flow-through mode. The versatility of the preparation technique is demonstrated by its use with hydrophobic, hydrophilic, ionizable, and zwitterionic monomers. Several system variables can be used to control the porous properties of the monolith over a broad range and to mediate the hydrodynamic properties of the monolithic devices. A variety of methods such as direct copolymerization of functional monomers, chemical modification of reactive groups, and grafting of pore surface with selected polymer chains is available for the control of surface chemistry. Since all the mobile phase must flow through the monolith, the convection considerably accelerates mass transport within the molded material, and the monolithic devices perform well, even at very high flow rates. The applications of polymeric monolithic materials are demonstrated mostly on the separations in the HPLC mode, although CEC, gas chromatography, enzyme immobilization, molecular recognition, advanced detection systems, and microfluidic devices are also mentioned.  相似文献   

15.
以液体石蜡为油相,间苯二酚和甲醛的水溶液为水相,吐温80和司班80为乳化剂,获得油/水(O/W)型乳状液.将该乳状液聚合、碳化去除模板后制得了碳材料,研究了不同催化剂对所得碳材料形貌的影响.结果表明:选择NaOH为催化剂时,制得的碳材料是一种具有孔壁和孔洞的多孔碳泡沫,典型样品的孔径约为1-2μm;当氨水为催化剂时,所得碳材料是由微球或者相互缠绕的蠕虫状粒子组成的块体材料,这些微球或粒子的直径主要集中在1-2μm,与NaOH为催化剂时所得碳泡沫的孔径尺寸相当.研究发现,氨水的加入使得乳液体系发生了相转化,由原来的O/W型乳液逐渐转变为W/O型高内相乳液.从分子间氢键出发,应用内聚能理论探讨了催化剂导致的乳液相变以及不同形貌碳材料的形成过程.  相似文献   

16.
Two polar ligands, namely 3-hydroxypropionitrile and 1H-imidazole-4,5-dicarbonitrile (IDCN) were covalently attached to epoxy-activated silica-based monolithic capillary columns via an epoxide ring-opening reaction to yield CN-OH-Monolith and 2CN-OH-Monolith, respectively. The silica monolith was prepared by a sol-gel process, and the resulting "rod-like" stationary phase was subjected to pore tailoring with an alkaline solution to convert small pore domains to mesopore domains, thus yielding a monolith with bimodal pore structure consisting of flow through pores (i.e., flow channels for mobile-phase flow) and mesopores that provide most of the adsorption capacity of the monolith toward the separated solutes. The two polar monoliths, CN-OH-Monolith and 2CN-OH-Monolith, were evaluated in normal-phase CEC with organic-rich mobile phases less polar than the stationary phase. The 2CN-OH-Monolith bearing more polar functions than the CN-OH-Monolith exhibited more retention and improved selectivity toward model polar solutes.  相似文献   

17.
Li Y  Xiang R  Horváth C  Wilkins JA 《Electrophoresis》2004,25(4-5):545-553
A new kind of monolithic capillary column was prepared for capillary electrochromatography (CEC) with a positively charged polymer layer on the inner wall of a fused-silica capillary and a neutral monolithic packing as the bulk stationary phase. The fused-silica capillary was first silanized with 3-glycidoxypropyltrimethoxysilane (GPTMS). Polyethyleneimine (PEI) was then covalently bonded to the GPTMS coating to form an annular positively charged polymer layer for the generation of electroosmotic flow (EOF). A neutral bulk monolithic stationary phase was then prepared by in situ copolymerization of vinylbenzyl chloride (VBC) and ethylene glycol dimethacrylate in the presence of 1-propanol and formamide as porogens. Benzyl chloride functionalities on the monolith were subsequently hydrolyzed to benzyl alcohol groups. Effects of pH on the EOF mobility of the column were measured to monitor the completion of reactions. Using a column with this design, we expected general problems in CEC such as irreversible adsorption and electrostatic interaction between stationary phase and analytes to be reduced. A peptide mixture was successfully separated in counter-directional mode CEC. Comparison of peptide separations in isocratic monolithic CEC, gradient HPLC and capillary zone electrophoresis (CZE) indicated that the separation in CEC is governed by a dual mechanism that involves a complex interplay between selective chromatographic retention and differential electrophoretic migration.  相似文献   

18.
Chen Z  Hobo T 《Electrophoresis》2001,22(15):3339-3346
A silica-based chiral monolithic column prepared by sol-gel process and chemical modification of chiral selector was used for enantioseparation of dansyl amino acids and hydroxy acids by capillary electrochromatography (CEC) and mu-high-performance liquid chromatography (mu-HPLC). L-Prolinamide was modified as a chiral selector. The chiral stationary phase (CSP), the chiral complex of Cu(II) with L-prolinamide, provides an anodic electroosmotic flow (EOF) in CEC. The EOF was found to be dependent on applied electric field strength, the pH, and the composition of mobile phases. Scanning electron micrograph showed that monolithic columns have the morphology of continuous skeleton and large through-pore. D-Enantiomers migrated before L-enantiomers except for dansyl-(Dns)-DL-Ser. The separation efficiencies of up to 17600 (D) and 13,200 plates m(-1) (L) were achieved for the separation of DL-indole-3-lactic acid.  相似文献   

19.
胃蛋白酶亲和有机聚合物毛细管整体柱的制备及性能考察   总被引:1,自引:0,他引:1  
池翠杰  王伟  季一兵 《色谱》2014,32(8):791-797
以热引发原位聚合方法制备了聚(甲基丙烯酸缩水甘油酯(glycidyl methacrylate,GMA)-乙二醇二甲基丙烯酸酯(ethyleneglycol dimethacrylate,EDMA))毛细管整体柱,对整体柱的性能进行了表征。结果表明,柱内部结构均匀、渗透性好;整体柱能够实现苯等中性小分子化合物的分离,具有反相色谱特征,重现性和稳定性良好。利用整体柱环氧基团的活性,采用间接法,以戊二醛为连接臂制备胃蛋白酶亲和手性整体柱。在毛细管电色谱模式下进行了柱分离性能研究,并对缓冲液pH值和运行电压等分离条件进行了考察。结果表明,亲和整体柱对4种碱性手性药物(奈福泮、氨氯地平、西酞普兰、扑尔敏)有拆分效果,奈福泮、氨氯地平、西酞普兰能达到基线分离。本文为蛋白质亲和毛细管电色谱整体柱的制备和应用提供了新的思路和方法。  相似文献   

20.
Jin W  Fu H  Huang X  Xiao H  Zou H 《Electrophoresis》2003,24(18):3172-3180
Preparation of a poly(styrene-co-divinylbenzene-co-methacrylic acid) monolithic stationary phase for the use in capillary electrochromatography (CEC) has been improved by optimizing the polymerization conditions. It is observed that the reaction time strongly affects column efficiency, while the proportion of isooctane in porogen influences peak symmetry of some solutes seriously. The lifetime of the monolithic columns prepared mainly depends on the pH of buffers used. Reproducibility of electroosmotic flow (EOF) from batch to batch columns are lower than 2.8% relative standard deviation. Unlike other types of capillary electrochromatographic monoliths, a pH-dependent EOF was observed on this type of column. Separation of various types of compounds including aromatic hydrocarbons, hormones, anilines, basic pharmaceuticals, and peptides was achieved. The facile preparation and wide application of this monolithic column may make styrene-based polymer a potential stationary phase in CEC.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号