首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
A method for the headspace analysis of dimethyl sulphide in blood and adipose tissue has been established. Blood (0.2 ml) or adipose tissue (0.5 g) with added dimethyl sulphide was sealed in a 10-ml vial using PTFE sheet to prevent escape of dimethyl sulphide from the headspace. Equilibration was performed at 60 degrees C for 4 h, and 20 microliters of gaseous phase sampled from the headspace was subjected to gas chromatography (with flame photometric detection). Calibration curves were prepared for the two samples. Linearity was observed in the range from 5-10 micrograms to 2 mg.  相似文献   

2.
Huang MK  Liu C  Huang SD 《The Analyst》2002,127(9):1203-1206
A fiber-stable, repeatable and highly sensitive headspace solid-phase microextraction (HS-SPME) method was developed for the analysis of methamphetamine (MA) and amphetamine (AM) in urine using gas chromatography-mass spectrometry (GC-MS) in the selected ion monitoring mode. For sample preparation, the test specimen was placed in a 7 ml vial along with the additives (KOH and NaCl) and the internal standards (d8-MA and d8-AM), a glass insert containing heptafluorobutyric anhydride (HFBA) and heptafluorobutyric chloride (HFBCl) as derivatizing reagents was inserted into the vial, the vial was then sealed tightly. A SPME device with a 100 microm polydimethylsiloxane fiber was inserted into the vial and the fiber was exposed to the headspace in the insert, then the vial was heated and stirred at 100 degrees C and 600 rpm for 20 min for evaporation/adsorption/derivatization. The vaporized analytes (AM and MA) in the vial diffused into the glass insert though the holes on the insert, they absorbed onto the fiber, and then interacted with the vapor of the derivatizing reagent. Some of the analytes in the headspace of the glass insert may react with the vapor of the derivatizing reagent first, and then adsorb onto the fiber. The needle was finally removed and inserted into the injection port to desorb the analytes with the fiber exposed to the liner of the GC-MS system for analysis. By combining HFBCl and HFBA as derivatizing reagents and placing them in an insert, the HS-SPME method achieves high sensitivity for the analysis of AM and MA. Correlation coefficients derived from typical calibration curves in the 1.0-1700 ng ml(-1) range are 0.998 for MA and 0.994 for AM. The limits of detection and the limits of quantitation using a sample size of 1 ml are 0.3 and 1.0 ng ml(-1), respectively, for both MA and AM in urine specimens. Because the water hydrolysis of derivatizing reagent is much faster than the acylation reaction of the primary and secondary amines with the derivatizing reagent, the amphetamines cannot be acylated effectively over heated aqueous solution, and therefore this study provides a new acylation design in moisture surroundings. The proposed process also simplifies the procedure for urine sample preparation, and makes the automation of SPME possible.  相似文献   

3.
A multipurpose sampler (Gerstel MPS), designed for liquid large volume, gaseous and headspace samples was used for the GC-MS analysis of organic volatiles in human urine. Headspace sampling with a volume-, temperature- and speed-controlled gas-tight syringe was combined with a temperature-controlled cold injection system (CIS) for cold trapping, enrichment and focusing of analytes. Regular 2-ml GC vials filled with 1 ml acidified urine were used as headspace sampling vials. A 100-vial autosampler tray was equipped with an additional temperature and heating time controlled "preheating station" for five vials. Profiles of organic volatiles in human urine were determined and 34 components identified. Trimethylamine (TMA) and 4-heptanone as two metabolites of medical interest were quantified. Calibration curves and intra assay imprecision for 4-heptanone concentrations in the range of 40 to 800 ng/ml showed a correlation coefficient of r = 0.9980 and a relative standard deviation (RSD) between 3.0 and 3.4%. Calibration curves and intra-assay imprecision for TMA concentrations in the range of medical interest from 0.5 to 20 micrograms/ml showed a correlation coefficient of r = 0.9968 and a RSD between 4.1 and 6.8%. The high practicability of the multipurpose sampler for both gaseous and liquid samples together with the here shown good reproducibility and sensitivity make this single CIS-GC-MS system very attractive for routine clinical use in metabolic profiling of organic volatiles (headspace) and non-volatiles (liquid).  相似文献   

4.
A sensitive method for the simultaneous high-performance liquid chromatographic determination of clarithromycin and its active metabolite in plasma and urine is described. Alkalinized samples were coextracted with an internal standard and analyzed on a C8 column using electrochemical detection. Recoveries were greater than or equal to 85% and consistent. Standard curves for plasma were linear in the range 0-2 micrograms/ml for both compounds (r greater than 0.99), with limits of quantification of approximately 10.03 micrograms/ml (0.5-ml sample). Within-day and day-to-day precision were good, with coefficients of variation mostly within +/- 5%; accuracy for both compounds were routinely within 90-110% of theoretical values. Standard curves for urine were linear in the range 0-100 micrograms/ml with limits of quantification of 0.5 micrograms/ml (0.2-ml sample). Urine assays also had similar within-day and day-to-day precisions and accuracy.  相似文献   

5.
A high-performance liquid chromatographic method is described for the determination of the new fluoroquinolone fleroxacin and its metabolites in plasma and urine. Plasma samples are deproteinized with acetonitrile, and, after evaporation and reconstitution of the supernatant, samples are analysed on a reversed-phase column. The limit of quantification is 10-20 ng/ml for the parent drug and 10 ng/ml for the metabolites, using a 0.2-ml sample. Urine samples are diluted with the mobile phase. An aliquot is then injected directly onto the column. The limits of quantification are 1 micrograms/ml for the parent drug and 0.5 micrograms/ml for the metabolites, using a 0.1-ml sample. The method has been successfully applied to pharmacokinetic studies of human volunteers and patients.  相似文献   

6.
Summary Ethanol has been found extractable from human whole blood and urine samples by headspace solid-phase micro extraction (SPME) with a Carbowax/divinylbenzene-coated fiber. After heating a vial containing the body fluid sample with ethanol, and isobutanol as internal standard (IS) at 70°C in the presence of (NH4)2SO4, a Carbowax/divinylbenzene-coated SPME fiber was exposed in the headspace of the vial to allow adsorption of the compounds. The fiber needle was then injected into a middle-bore capillary gas chromatography (GC) port. The headspace SPME-GC gave intense peaks for both compounds; a small amount of background noises appeared, but did not interfere with the detection of the compounds. Recoveries of ethanol and IS were 0.049 and 0.026% for whole blood, respectively, and 0.054 and 0.085% for urine, respectively. The calibration curves for ethanol showed excellent linearity in the range of 80–5000 mg L–1 for whole blood and 40–5000 mg L–1 for urine; the detection limits for both samples were 20 and 10 mg L–1, respectively. The data on actual determination of ethanol after the drinking of beer are also presented for two subjects.  相似文献   

7.
A gradient elution high-performance liquid chromatographic method is described for the analysis of the beta-lactamase inhibitor tazobactam (YTR-830H) and a semi-synthetic parenteral penicillin, piperacillin, in human plasma, serum, bile and urine. The assay for plasma, serum and bile involves deproteinization with acetonitrile and the removal of lipids with dichloromethane; urine is diluted with buffer. Separation and quantitation are achieved using a mobile phase based on ion-suppression chromatography on a C18 reversed-phase column with ultraviolet detection at 220 nm. The limit of quantitation for both compounds is 1.0 microgram/ml in plasma, serum and bile using a 0.2-ml sample and 50.0 micrograms/ml in urine using a 0.1-ml sample. The method has been validated by preparing and analyzing a series of fortified samples (range 1.0-200 micrograms/ml for each compound in plasma, serum and bile and 50.0-10,000 micrograms/ml for each compound in urine). Excellent linearity, accuracy, precision and recovery were obtained. The method was not interfered with by other endogenous components, nor by other commonly administered antibiotics such as amoxicillin, mezlocillin, cefometazole and cefotaxime. The assay has been successfully applied to the analysis of samples from pharmacokinetic studies in man and animals.  相似文献   

8.
A high-performance liquid chromatographic (HPLC) procedure with photodiode-array detection (DAD) is described for the determination of (S)-(-)-cathinone (S-CA) and its metabolites (R,S)-(-)-norephedrine (R-NE) and (R,R)-(-)-norpseudoephedrine (R-NPE) in urine. Extraction and clean-up of 1-ml urine samples were performed on a cyano-bonded solid-phase column using (+/-)-amphetamine as internal standard. The concentrated extracts were separated on a 3-microns ODS-1 column with acetonitrile-water-phosphoric acid-hexylamine as the mobile phase. Peak detection was done at 192 nm. The detection limits for S-CA and R-NE/R-NPE in urine were 50 and 25 ng/ml, respectively. The differentiation of the enantiomers of cathinone and norephedrine was achieved by derivatization with (S)-(-)-1-phenylethyl isocyanate to the corresponding diastereomers followed by HPLC-DAD on a 5-microns normal-phase column. The R and S enantiomers of norpseudoephedrine were determined by gas chromatography-mass spectrometry after on-column derivatization with (S)-(-)-N-trifluoroacetylprolyl chloride. Following a single oral dose of 0.5 mg/kg of S-CA, the concentrations found in urine ranged from 0.2 to 3.8 micrograms/ml of S-CA, from 7.2 to 46.0 micrograms/ml of R-NE and from 0.5 to 2.5 micrograms/ml of R-NPE.  相似文献   

9.
An automated extraction and determination method for the gas chromatography (GC)-mass spectrometry (MS) analysis of amphetamine-related drugs in human urine is developed using headspace solid-phase microextraction (SPME) and in-matrix derivatization. A urine sample (0.5 mL, potassium carbonate (5 M, 1.0 mL), sodium chloride (0.5 g), and ethylchloroformate (20 microL) are put in a sample vial. Amphetamine-related drugs are converted to ethylformate derivatives (carbamates) in the vial because amphetamine-related drugs in urine are quickly reacted with ethylchloroformate. An SPME fiber is then exposed at 80 degrees C for 15 min in the headspace of the vial. The extracted derivatives to the fiber are desorbed by exposing the fiber in the injection port of a GC-MS. The calibration curves show linearity in the range of 1.0 to 1000 ng/mL for methamphetamine, fenfluramine, and methylenedioxymethamphetamine; 2.0 to 1000 ng/mL for amphetamine and phentermine; 5.0 to 1000 ng/mL for methylenedioxyamphetamine; 10 to 1000 ng/mL for phenethylamine; and 50 to 1000 ng/mL for 4-bromo-2,5-dimethoxyphenethylamine in urine. No interferences are found, and the time for analysis is 30 min for one sample. Furthermore, this proposed method is applied to some clinical and medico-legal cases by taking methamphetamine. Methamphetamine and its metabolite amphetamine are detected in the urine samples collected from the patients involved in the clinical cases. Methamphetamine, amphetamine, and phenethylamine are detected in the urine sample collected from the victim of a medico-legal case.  相似文献   

10.
Membrane-assisted solvent extraction was applied to the determination of polychlorinated biphenyls (PCBs) in aqueous samples. The apparatus of membrane-assisted solvent extraction consisted of a 20 ml headspace vial which was filled with 15 ml of the aqueous sample. The membrane bag was placed into the vial and the extraction took place in an agitator. After extraction, the analytes were transferred into the inlet of a gas chromatograph by large volume injection. A mass-selective detector was used. The whole procedure was fully automated. The work included optimization of the extraction conditions (stirring rate and extraction time) and the influence of matrix effects like salt addition and the presence of organic solvents was studied. Calibration was performed using injection volumes of 100 and 400 microl. Several parameters like linearity and reproducibility of the procedure were determined. At optimized conditions detection limits in the ng/l range were achieved. The effectiveness of the method towards real samples was tested by analyzing river water, white wine and apple juice.  相似文献   

11.
The hyphenated technique namely microwave-assisted headspace solid-phase microextraction (MA-HS-SPME) was developed and studied for the simultaneous extraction/enrichment of polychlorinated biphenyls (PCBs) in aqueous samples prior to the quantification by gas chromatography (GC). The PCBs in aqueous media are extracted onto a solid-phase micro fibre via the headspace with the aid of microwave irradiation. The optimum conditions for obtaining extraction efficiency, such as the extraction time, addition of salts, addition of methanol, ratio of sample to headspace volume, and the desorption parameters were investigated. Experimental results indicated that the proposed MA-HS-SPME method attained the best extraction efficiency under the optimized conditions, i.e., irradiation of extraction solution (20 ml aqueous sample in 40 ml headspace vial with no additions of salt and methanol) under 30 W microwave power for 15 cycles (1 min power on and 3 min power off of each cycle). Desorption at 270 degrees C for 3 min provided the best detection results. The detection limit obtained were between 0.27 and 1.34 ng/l. The correlation coefficient for the linear dynamic range from 1 to 80 ng/l exceeded 0.99 for 18 PCBs.  相似文献   

12.
A simple procedure for the determination of methyl tert-butyl ether (MTBE), ethyl tert-butyl ether (ETBE), ethyl butyl ether (EBE), tert-amyl methyl ether (TAME), benzene, toluene, ethylbenzene, and xylenes (BTEX) in water using headspace (HS) solid-phase microextraction (HS-SPME) was developed. The analysis was carried out by gas chromatography (GC) equipped with flame ionization detector (FID) and 100% dimethylpolysiloxane fused capillary column. A 2 Plackett-Burman design for screening and a central composite design (CCD) for optimizing the significant variables were applied. Fiber type, extraction temperature, sodium chloride concentration, and headspace volume were the significant variables. A 65 microm poly(dimethylsiloxane)-divinylbenzene (PDMS-DVB) SPME fiber, 10 degrees C, 300 g/l, and 20 ml of headspace (in 40 ml vial) were respectively chosen for the best extraction response. An extraction time of 10 min was enough to extract the ethers and BTEX. The relative standard deviation (R.S.D.) for the procedure varied from 2.6 (benzene) to 8.5% (ethylbenzene). The method detection limits (MDLs) found were from 0.02 (toluene, ethylbenzene, and xylenes) to 1.1 microg/l (MTBE). The optimized method was applied to the analysis of the rivers, marinas and fishing harbors surface waters from Gipuzkoa (North Spain). Three sampling were done in 1 year from June 2002 to June 2003. Toluene was the most detected analyte (in 90% of the samples analyzed), with an average concentration of 0.56 microg/l. MTBE was the only dialkyl ether detected (in 15% of the samples) showing two high levels over 400 microg/l that were related to accidental fuel spill.  相似文献   

13.
This paper reported a full evaporation headspace gas chromatographic (GC) technique for determination of methanol content in black liquors (pulping spent liquor). In this method, a very small volume (10-20 microL) of liquor sample is introduced into a headspace sample vial (20 mL) and heated up to a temperature of 105 degrees C. A near-complete mass transfer of methanol from the liquid phase to vapor phase (headspace), i.e., a full evaporation, can be achieved within 3 min. The methanol in the headspace of the vial is then measured by GC. The present method is simple, rapid and accurate.  相似文献   

14.
A high-performance liquid chromatographic method for the determination of the histamine H1-receptor antagonist cetirizine in human urine was developed. Cetirizine and the internal standard are extracted from acidified (pH 5) urine (0.5 ml) into chloroform and the organic layer is evaporated to dryness. The residue is chromatographed on a Spherisorb 5ODS-2 column using Pic A (5 mM aqueous tetrabutylammonium phosphate)-methanol-tetrahydrofuran (33:65:2, v/v) as the mobile phase with ultraviolet detection (230 nm). The calibration graph is linear from 0.1 to 10 micrograms/ml and using 0.5 ml of urine the detection limit is 20 ng/ml. The within-run relative standard deviation is less than 6% and the accuracy is within 10% of the theoretical value at concentrations between 0.1 and 10 micrograms/ml in urine. There is a good correlation (r = 0.99606) with a previously described capillary gas chromatographic assay.  相似文献   

15.
A simple device was developed for in-vial liquid-liquid extraction using a polymer membrane (nonporous polypropylene) to separate an aqueous sample from an organic extractant. The membrane consisted of tubing with an internal diameter of 6 mm and a wall thickness of 0.05 mm, which was heat-sealed at the lower end and filled with 500 microl hexane. This membrane bag was incorporated into a conventional 20 ml headspace vial suitable for a multi-purpose sampler (MPS 2, Gerstel, Mülheim, Germany) directly interfaced to a gas chromatograph with a mass-selective detector. The sampler enabled the extraction vial to be mixed at a defined temperature with subsequent large-volume injection of the organic extract taken from the membrane bag. The method was evaluated using several triazines, 2,4-dichloroaniline, alpha-hexachlorocyclohexane and phenanthrene as model compounds. Extraction parameters such as temperature, agitation speed, and extraction time were optimised. Recoveries of 60-90% were achieved after 30 min extraction. By increasing the injection volume to 100 microl, detection limits of 1-10 ng/l were determined.  相似文献   

16.
Summary A very simple method for the analysis of methamphetamine and amphetamine in human whole blood and urine by headspace gas chromatography (GC) has been presented. It neither needs solid-phase microextraction nor cryogenic trapping devices, but only a conventional capillary GC instrument with flame ionization detection (FID). The two special points to be mentioned in this method are the in-matrix derivatization of amphetamines for vaporization and the capability of injection of as large as 5 mL of the headspace vapor into a GC instrument in the splitless mode for sensitive detection. After heating a whole blood or urine sample containing amphetamines, -methylbenzylamine (internal standard, IS) and heptafluoro-n-butyryl chloride under alkaline conditions in a 7.0-mL vial at 90 °C for 20 min, 5 mL of the headspace vapor was drawn with a glass syringe and injected into the gas chromatograph. During injection the column was at 40 °C to trap the analytes, and then the oven temperature was programmed up to 320 °C. Sharp peaks were obtained for each analyte and IS, and only a relatively small number of background impurity peaks for the whole blood and urine samples. The detection limits for each amphetamine were estimated to be 0.1 g mL–1 for whole blood and 0.03 g mL–1 for urine. Precision and linearity were also tested to confirm the reliability. Methamphetamine and amphetamine could be determined from whole blood and urine obtained at autopsy in three methamphetamine poisoning cases. The identity of each peak appearing in the gas chromatograms was confirmed by GC/mass spectrometry.  相似文献   

17.
Simple and reproducible high-performance liquid chromatographic (HPLC) and gas chromatographic-mass spectrometric (GC-MS) methods have been developed for the simultaneous analysis of several acidic drugs in horse plasma and urine. Although the capillary GC-MS column provided better separation of the drugs than the reversed-phase C8 (3 microns, 75 mm) HPLC column, the total analysis time with HPLC was shorter than the total analysis time with GC-MS. The HPLC system equipped with a diode-array detector provided simultaneous screening (limit of detection 100-500 ng/ml) and confirmation (limit 1.0 micrograms/ml) of the drugs. The HPLC system equipped with fixed-wavelength ultraviolet and fluorescence detectors provided a relatively sensitive screening [limit of detection 50-150 ng/ml for ultraviolet and 10 ng/ml for fluorescence (naproxen only) detectors] of the drugs. However, the positive samples had to be confirmed by using either the diode-array detector or the GC-MS system. The GC-MS system provided simultaneous screening and confirmation of the drugs at very low concentrations (20-50 ng/ml).  相似文献   

18.
Summary A simple and sensitive method is presented for determination of styrene, toluene, ethylbenzene, isopropylbenzene andn-propylbenzene in human body fluids by capillary gas chromatography (GC) with cryogenic oven trapping. After heating a blood or urine sample containing each compound andp-diethylbenzene (internal standard, IS) in a 7.0-mL vial at 60°C for 20 min, 5 mL of headspace vapor was drawn into a glass syringe and injected into a GC. All vapor was introduced into an Rtx-Volatile middle bore capillary column in splitless mode at oven temperature of 20°C to trap entire analytes, and the oven temperature then programmed to 280°C for GC measurements by flame ionization detection. The present conditions gave sharp peaks of each compound and IS, and low background noises for whole blood or urine samples.  相似文献   

19.
A simple method for the analysis of nereistoxin and its metabolites in human serum using headspace solid-phase microextraction (SPME) and gas chromatography-mass spectrometry (GC-MS) is developed. A vial containing a serum sample, 5M sodium hydroxide, and benzylacetone (internal standard) is heated to 70 degrees C, and an SPME fiber is exposed for 30 min in the headspace of the vial. The compounds extracted by the fiber are desorbed by exposing the fiber in the injection port of the GC-MS. The calibration curves show linearity in the range of 0.05-5.0 micrograms/mL for nereistoxin and N-methyl-N-(2-methylthio-1-methylthiomethyl)ethylamine, 0.01-5.0 micrograms/mL for S,S'-dimethyl dihydronereistoxin, and 0.5-10 micrograms/mL for 2-methylthio-1-methylthiomethylethylamine in serum. No interferences are found, and the analysis time is 50 min for one sample. In addition, this proposed method is applied to a patient who attempted suicide by ingesting Padan 4R, a herbicide. Padan 4R contains 4% cartap hydrochloride, which is an analogue of nereistoxin. Nereistoxin and its metabolites are detected in the serum samples collected from the patient during hospitalization. The concentration ranges of nereistoxin in the serum are 0.09-2.69 micrograms/mL.  相似文献   

20.
A method is proposed for determining formaldehyde by headspace gas chromatography using an o-(2,3,4,5,6-pentafluorobenzyl)hydroxylamine (PFBHA) derivatizing agent. Formaldehyde in urine was derivatized to o-(pentafluorobenzyl)oxime and extracted by heating an urine sample with PFBHA in a sealed vial. Gas-chromatographic analysis of the headspace was performed in the temperature-programmed mode using an HP-5 capillary column with a flame ionization detector. The limit of detection is 3.5 μg/L. The accuracy of the procedure, equivalent to an extended relative uncertainty, does not exceed 21%. The examination of the procedure using urine samples of the population of the Irkutsk region has shown that the regional reference levels of formaldehyde concentration are in the range 44–83 μg/L.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号