首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
The design and testing of a new and low-cost experimental setup used for vacuum-assisted headspace solid-phase microextraction (Vac-HSSPME) is reported here. The device consists of a specially designed O-ring seal screw cap offering gas-tight seal to commercially available headspace vials. The new polytetrafluoroethylene (PTFE) cap was molded by a local manufacturer and had a hole that could tightly accommodate a septum. All operations were performed through the septum: air evacuation of the sampler, sample introduction and HSSPME sampling. The analytical performance of the new sampler was evaluated using 22 mL headspace vials with 9 mL water samples spiked with polychlorinated biphenyls (PCBs). Several experimental parameters were controlled and the optimized conditions were: 1000 rpm agitation speed; 30 min extraction time; 40 °C sampling temperature; polydimethylsiloxane-divinylbenzene (PDMS-DVB) fiber. The lack of accurate Henry's law constant (KH) values and information regarding how they change with temperature was a major limitation in predicting the phase location of evaporation resistance during Vac-HSSPME. Nevertheless, the combined effects of system conditions indicated the increasing importance of gas phase resistance with increasing degree of PCBs chlorination. Stirring enhancements were not recorded for the higher chlorinated PCBs suggesting that the hyperhydrophobic gas/water interface was the preferred location for these compounds. Analytically, the developed method was found to yield linear calibration curves with limits of detection in the sub ng L−1 level and relative standard deviations ranging between 5.8 and 14%. To compensate for the low recoveries of the higher chlorinated PCB congeners in spiked river water the standard addition methodology was applied. Overall, the compact design of the new and reusable sample container allows efficient HSSPME sampling of organic analytes in water within short extraction times and at low sampling temperatures compared to other published HSSPME methods.  相似文献   

2.
The direct coupling of a headspace sampler with a mass spectrometer is proposed as a screening tool for the rapid detection of soil pollution by hydrocarbons from petroleum and derivatives. The samples are subjected to the headspace generation process, with no prior treatment, and the volatiles generated are introduced directly into the mass spectrometer, thereby obtaining a fingerprint of the sample analysed. Suitable treatment of the signal by chemometric techniques allows unequivocal characterisation of the different types of sample. The use of fast gas chromatography with a mass spectrometer detector coupled to the headspace sampler allows identification of the major hydrocarbons present in the mineral and organic polluted samples, interpretation of the results obtained, and demonstrates the analytical potential of headspace-mass spectrometry coupling.  相似文献   

3.
A new solid-phase microextraction fiber based on alumina/titania sol-gel-coated on copper wire for headspace sampling of chlorinated organic solvents (chloroform, carbon tetrachloride, trichloroethene, and tetrachloroethene) from urine samples is introduced. The influences of fiber coating composition and microextraction conditions (extraction temperature, extraction time, and ionic strength of the sample matrix) on the fiber performance were investigated. Also, the influence of temperature and time on desorption of analytes from fiber was studied. The proposed fiber has high capacity and demonstrates fast sampling of chlorinated organic solvents from urine samples with high sensitivity. The relative standard deviation (RSD, n=5) for all analytes was below 6.5%.  相似文献   

4.
An experimental method for the analysis of volatile organic compounds in polymers is described. The technique involves dynamic headspace sampling, collection, and concentration of the volatiles in a cold trap, followed by capillary column gas chromatography/mass spectometry. Flow switching is carried out by the Deans switching technique. Four technical polymers used as pharmaceutical packaging materials have been analyzed in order to demonstrate the method.  相似文献   

5.
A GC autosampler designed for liquid injection was modified for static headspace sampling. The modification was very simple and involved replacement of the standard 10-μL syringe with a 100-μL gas-tight syringe. Liquid samples (0.2-1.0 mL) were placed in 2-mL vials, normally used for liquid sampling and an aliquot of the head-space above the liquid was withdrawn and injected into the GC. All parts of the sampling system were at ambient temperature. The system was found to be useful for several applications. Among those discussed in this paper are determination of ethanol in the blood or urine of individuals suspected of driving while intoxicated, residual organic solvents in pharmaceuticals, and screening of effluent waters from industrial plants for acrylonitrile.  相似文献   

6.
A multiple headspace extraction-capillary gas chromatographic method for the quantitative, accurate, and rapid determination of volatiles in multicontaminated soil samples has been developed. A thick film fused silica column has been used and a nine-step multiple headspace extraction (MHE) determination performed. Calibration was achieved by introducing 1 μl of a standard solution of mixed volatiles into empty headspace vials, the presence of the matrix being unnecessary in multiple headspace extraction. Accuracy of determination by MHE-CGC and a simple method employing standard additions have been compared.  相似文献   

7.
The aim of the present study was to evaluate the suitability of ion mobility spectrometry (IMS) for the detection of human urine as an indication of human presence during urban search and rescue operations in collapsed buildings. To this end, IMS with a radioactive ionization source and a multicapillary column was used to detect volatile organic compounds (VOCs) emitted from human urine. A study involving a group of 30 healthy volunteers resulted in the selection of seven volatile species, namely acetone, propanal, 3-methyl-2-butanone, 2-methylpropanal, 4-heptanone, 2-heptanone and octanal, which were detected in all samples. Additionally, a preliminary study on the permeation of urine volatiles through the materials surrounding the voids of collapsed buildings was performed. In this study, quartz sand was used as a representative imitating material. Four compounds, namely 3-methyl-2-butanone, octanal, acetone and 2-heptanone, were found to permeate through the sand layers during all experiments. Moreover, their permeation times were the shortest. Although IMS can be considered as a potential technique suitable for the detection, localization and monitoring of VOCs evolved from human urine, further investigation is necessary prior to selecting field chemical methods for the early location of trapped victims.  相似文献   

8.
A novel geometry configuration based on sorbent-coated glass microfibers packed within a glass capillary is used to sample volatile organic compounds, dynamically, in the headspace of an open system or in a partially open system to achieve quantitative extraction of the available volatiles of explosives with negligible breakthrough. Air is sampled through the newly developed sorbent-packed 2 cm long, 2 mm diameter capillary microextraction of volatiles (CMV) and subsequently introduced into a commercially available thermal desorption probe fitted directly into a GC injection port. A sorbent coating surface area of ~5?×?10?2 m2 or 5,000 times greater than that of a single solid-phase microextraction (SPME) fiber allows for fast (30 s), flow-through sampling of relatively large volumes using sampling flow rates of ~1.5 L/min. A direct comparison of the new CMV extraction to a static (equilibrium) SPME extraction of the same headspace sample yields a 30 times improvement in sensitivity for the CMV when sampling nitroglycerine (NG), 2,4-dinitrotoluene (2,4-DNT), and diphenylamine (DPA) in a mixture containing a total mass of 500 ng of each analyte, when spiked into a liter-volume container. Calibration curves were established for all compounds studied, and the recovery was determined to be ~1 % or better after only 1 min of sampling time. Quantitative analysis is also possible using this extraction technique when the sampling temperature, flow rate, and time are kept constant between calibration curves and the sample.  相似文献   

9.
A fully automated cold fiber solid phase microextraction device has been developed by coupling to a GERSTEL multipurpose (MPS 2) autosampler and applied to the analysis of volatiles and semi-volatiles in aqueous and solid matrices. The proposed device was thoroughly evaluated for its extraction performance, robustness, reproducibility and reliability by gas chromatograph/mass spectrometer (GC/MS). With the use of a septumless head injector, the entire automated setup was capable of analyzing over 200 samples without any GC injector leakages. Evaluation of the automated cold fiber device was carried out using a group of compounds characterized by different volatilities and polarities. Extraction efficiency as well as analytical figures of merit was compared to commercial solid phase microextraction fibers. The automated cold fiber device showed significantly improved extraction efficiency compared to the commercial polydimethylsiloxane (PDMS) and cold fiber without cooling for the analysis of aqueous standard samples due to the low temperature of the coating. Comparing results obtained from cold fiber and commercial divinylbenzene/carboxen/polydimethylsiloxane (DVB/CAR/PDMS) fiber temperature profile demonstrated that the temperature gap between the sample matrix and the coating improved the distribution coefficient and therefore the extraction amount. The linear dynamic range of the cold fiber device was 0.5 ng mL−1 to 100 ng mL−1 with a linear regression coefficient ≥0.9963 for all compounds. The limit of detection for all analytes ranged from 1.0 ng mL−1 to 9.4 ng mL−1. The newly automated cold fiber device presents a platform for headspace analysis of volatiles and semi-volatiles for large number of samples with improved throughput and sensitivity.  相似文献   

10.
A headspace sampling method is described for concentrating milk volatiles onto a multi-channel open tubular silicone rubber trap (MCT) for thermal desorption into a GC-FID. Sections of the chromatographic profile, single peaks or combinations of compounds are recaptured with secondary MCTs during a subsequent run. The recaptured aroma is released in a controlled manner by heating the MCT in a portable heating device. An aroma release window of several minutes allows up to six people the opportunity to sniff each aroma fraction more than once. Olfactory results suggest that a synergistic combination of 2-heptanone and 2-nonanone could be responsible for a pungent cheese, sour milk-like aroma. MCTs containing single components or fractions can be desorbed into a GC-MS for compound identification.  相似文献   

11.
A method for the determination of trace amounts of the herbicide oxadiazon was developed using headspace solid-phase microextraction (HS-SPME), gas chromatography-mass spectrometry (GC-MS) and selected ion monitoring. It was applied to determine oxadiazon in ground water, agricultural soil, must, wine and human urine samples. To determine oxadiazon in liquid samples, a response surface methodology generated with a Doehlert design was applied to optimize the HS-SPME conditions using a 100 microm polydimethylsiloxane fibre. For the analysis of soil samples, they were mixed with water and the SPME fibre suspended in the headspace above the slurry. Ground water, human urine and must show linear concentration range of application of 0.5-50 ng ml(-1)' with detection limits < or =0.02 ng ml(-1). HS-SPME-GC-MS analysis yielded good reproducibility (RSD values between 6.5 and 13.5%). The method validation was completed with spiked matrix samples. The developed analytical procedure is solvent free, cost effective and fast.  相似文献   

12.
A new analytical method for the determination of halogenated and aromatic volatile organic compounds in groundwater, mineral water, and drinking water at concentrations ranging between 1-10000 ng/L is developed. A new type of headspace sampler that combines static headspace sampling with a trap is used, yielding very low detection limits and good repeatability without carryover effects. An unexpected transformation of 1,1,2,2-tetrachloroethane into trichloroethene is observed and explained.  相似文献   

13.
Nickel capillary columns coated with moderately polarstationary phases such as Witconol can be used for the separation of the organic volatile fraction from biological fluids. A “transevaporator” sampling technique for the collection of the organic volatiles on glass beads from as little as 5 to 500 μl of biological fluids (e.g. urine, serum, amniotic fluid, breast milk, saliva, etc.) is described. The organic volatiles are thermally desorbed from the glass beads into a short precolumn cooled in liquid nitrogen, which overcomes the problems associated with sample introduction onto narrow-bore capillary columns. The application of the full analytical technique to problems associated with the early detection of disease is illustrated.  相似文献   

14.
The goal of this work was to determine the microbial volatile organic compounds emitted by moulds growing on wool in search of particular volatiles mentioned in the literature as indicators of active mould growth. The keratinolytically active fungi were inoculated on two types of media: (1) samples of wool placed on broths, and (2) on broths containing amino acids that are elements of the structure of keratin. All samples were prepared inside 20 mL vials (closed system). In the first case (1) the broths did not contain any sources of organic carbon, nitrogen, or sulfur, i.e. wool was the only nutrient for the moulds. A third type of sample was historical wool prepared in a Petri dish without a broth and inoculated with a keratinolytically active mould (open system). The microbial volatiles emitted by moulds were sampled with the headspace solid‐phase microextraction method. Volatiles extracted on solid‐phase microextraction fibers were analyzed in a gas chromatography with mass spectrometry system. Qualitative and quantitative analyses of chromatograms were carried out in search of indicators of metabolic activity. The results showed that there are three groups of volatiles that can be used for the detection of active forms of moulds on woollen objects.  相似文献   

15.
固相微萃取-气相色谱/质谱分析栀子花的头香成分   总被引:30,自引:0,他引:30  
刘百战  高芸 《色谱》2000,18(5):452-455
 分别用固相微萃取和动态顶空法分离栀子鲜花的头香成分,用GC/MS技术分析鉴定,并用GC/MS总离子流色谱峰的峰面积进行归一化定量。在固相微萃取方法中,共鉴定了54种化学成分,占总峰面积的99.98%。主要成分(质量分数)依次为金合欢烯(64.86%)、罗勒烯(29.33%)、芳樟醇(2.74%)、惕各酸顺式叶醇酯(1.34%)和苯甲酸甲酯(0.25%)等。经与动态顶空法的分析结果比较发现,固相微萃取法不仅操作简便,而且具有较高的采样灵敏度,获得的化学成分的信息量多于动态顶空法。  相似文献   

16.
A static headspace gas chromatographic method for the simultaneous separation of trace light hydrocarbons and volatile organosulphur compounds in gases of nineteen Clostridium cultures at reduced pressure is described. The separation was achieved on n-octane-Porasil C after sampling of the gaseous compounds in a PTFE loop without any pretreatment. Most peaks were identified by gas chromatography-mass spectrometry. The presence of methane and ethylene sulphide among Clostridium volatiles is confirmed and 3-methyl-1-butene, 2-methyl-2-butene, dimethyl trisulphide and S-methyl thioacetate are reported for the first time in the Clostridium group.  相似文献   

17.
A method for the headspace analysis of dimethyl sulphide in blood and adipose tissue has been established. Blood (0.2 ml) or adipose tissue (0.5 g) with added dimethyl sulphide was sealed in a 10-ml vial using PTFE sheet to prevent escape of dimethyl sulphide from the headspace. Equilibration was performed at 60 degrees C for 4 h, and 20 microliters of gaseous phase sampled from the headspace was subjected to gas chromatography (with flame photometric detection). Calibration curves were prepared for the two samples. Linearity was observed in the range from 5-10 micrograms to 2 mg.  相似文献   

18.
Single-drop microextraction (SDME), an emerging miniaturised extraction technique, was for the first time combined with multiple headspace extraction (MHE) to enable the quantitative determination of volatiles in solid matrixes by SDME technique. The concept of multiple headspace single-drop microextraction (MHS-SDME) was then applied for quantitative determination of styrene in polystyrene (PS) samples. Good linearity for the multiple headspace extraction was obtained when the migration of styrene was facilitated by grinding the samples and incubating them for 1 h at 150 degrees C prior the first extraction. Two microlitres of butyl acetate was used as the single-drop microextraction solvent and the extraction time was 5 min per cycle. The relative standard deviation (RSD) for single-drop microextraction of styrene standard at n=6 was 7.6%. Linearity was shown for styrene concentrations between 0.005 and 0.75 microg/ml (R2=0.999). This corresponds to total amount of styrene between 0.1 and 15 microg. The limit of quantitation for styrene standard at S/N 10 was 0.005 microg/ml. The developed method was validated against and showed good agreement with an earlier reported dissolution-precipitation method.  相似文献   

19.
Two methods for sampling and concentration of volatile organic compounds are reported. In the first method, traps coated with a very thick film (ca. 100 μm) of cross-linked silicone stationary phase are employed. Such thick films can be prepared with a modified dynamic coating procedure, which is briefly described. The low phase ratio traps can be utilized for enrichment of volatiles from gaseous as well as aqueous matrices. The second technique is based on chromatographic evaporation of a solvent in a capillary tube, where the process is sustained by a repeated sample injection and a cyclic flow reversal. In this way, large solvent volumes can be handled by a small volume system. Under optimal conditions, when using a solvent barrier, quantitative recovery is possible even for compounds of comparatively high volatility. Another important application of the technique is extraction of trace components from gases such as headspace samples, polluted air, etc.  相似文献   

20.
The Willems badge, a diffusive sampler for nitrogen dioxide, has previously been validated for ambient air measurements. This paper describes the laboratory and field validation of the Willems badge for personal sampling under working environment conditions. The mean sampling rate in the laboratory tests was 46 ml min(-1), with an RSD of 12%. No statistically significant effects on sampling rate of the sampling time, concentration of NO2 or relative humidity were found. A slightly decreased sampling rate was observed at low wind velocity. This was also confirmed during static sampling, which makes the sampler less appropriate for static sampling indoors. No back diffusion was observed. Storage of the samplers for two weeks before or after exposure did not affect the sampling rate. Our analysis is based on a modified colorimetric method, performed by FIA (flow injection analysis). This technique was compared to ion chromatography analysis. The use of ion chromatography lowered the detection limit from 11 to 2 microg m(-3) for an 8 h sample, and furthermore enabled the detection of other anions. In conclusion, the diffusive sampler was found to perform well for personal measurements in industrial environments.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号