共查询到20条相似文献,搜索用时 15 毫秒
1.
Zholt Kormosh Iryna Hunka Yaroslav Bazel Andriy Laganovsky Iryna Mazurenko Nataliya Kormosh 《Central European Journal of Chemistry》2007,5(3):813-823
The potentiometric response characteristics of a diclofenac selective electrode, based on ion association in different plasticizers,
were compared. The sensitivity, working range, detection limit and selectivity of membrane sensors demonstrated significant
dependence on the type of plasticizers. The potentiometric unit presented a linear response toward diclofenac concentrations
between 1 × 10−5 − 5 × 10−2 mol L−1, with slopes of approximately 60 mV dec−1, and exhibited a response time of 3 s. The potentiometric analysis of sodium diclofenac in pharmaceutical formulations was
perfomed by the membrane electrode proposed and compared with the results of potentiometric titration given by the Pharmacopoeia
of Ukraine.
相似文献
2.
Jaromíra Chýlková Renáta Šelešovská-Fadrná Jaroslava Machalíková 《Central European Journal of Chemistry》2007,5(2):479-495
The optimal process of pre-treatment and activation of gold rotating disc electrode (AuRDE) before voltammetric determination
of mercury is proposed. This treatment encompasses polishing of the electrode surface, electrochemical cycling, and activation.
This procedure both increases determination sensitivity as well as improves determination reproducibility. The detection limit
on the working electrode achieved using this approach amounted to 8.26·10−10 mol L−1for direct mercury determination in water solution (applying 200 s running accumulation). The procedure of the quantitative
mercury isolation from complicated sample matrix was developed as well. It provides better selectivity and significant increase
of sensitivity of mercury determination. In case of mercury isolation from one liter of water the detection limit is 6.23·10−11 mol L−1 (analyzing a greater sample volume the determined concentration could be lower).
相似文献
3.
Joanna Lenik Cecylia Wardak Barbara Marczewska 《Central European Journal of Chemistry》2008,6(4):513-519
Naproxen membrane electrodes based on different plasticizers and the quaternary ammonium salts (QASs) dimethyldidecylammonium
bromide, methyltrioctylammonium chloride, or tetraoctylammonium chloride, were prepared. The following basic parameters were
investigated for the optimal electrode: measurement range (10−4 − 10−1 mol L−1), slope of the linear range of the calibration curve (−58.3 mV decade−1), limit of detection (6.0 × 10−5 mol L−1), lifetime (2.5 months), dependence of the electrode potential on pH (5.5 − 9.0), reproducibility of potential (1.2 mV) and
selectivity coefficients in relation to selected organic and inorganic anions. The electrode was utilized for determination
of naproxen in tablets by the calibration curve method and the standard addition method.
相似文献
4.
Ibuprofen membrane electrodes based on different plasticizers: diisobutyl phthalate (DIBP), o-nitrophenyloctyl ether (o-NPOE),
dioctyl sebacate (DOS) and tetraoctylammonium 2-(4-isobutylphenyl)propionate were prepared. All electrodes show: a near Nernstian
slope of characteristic (58.3–60.9 mV decade−1) in the measurement range (10−4–10−1 mol L−1), limit of detection (5.0×10−5 mol L−1), really long lifetime (12 months), dependence of the electrode potential on pH (5.5–9.0), reproducibility of potential (0.6–1.2
mV) and selectivity coefficients in relation to some organic and inorganic anions. The electrodes were applied for the determination
of ibuprofen in tablets by the calibration curve method and the standard addition method.
相似文献
5.
Cecylia Wardak 《Central European Journal of Chemistry》2008,6(4):607-612
A new all plastic sensor for Co2+ ions based on 2-amino-5 (hydroxynaphtyloazo-1′)-1,3,4 thiadiazole (ATIDAN) as ionophore was prepared. The electrode exhibits
a low detection limit of 1.5 × 10−6 mol L−1 and almost theoretical Nernstian slope in the activity range 4.0 × 10−6–1 × 10−1 mol L−1 of cobalt ions. The response time of the sensor is less than 10 s and it can be used over a period of 6 months without any
measurable divergence in potential. The proposed sensor shows a fairly good selectivity for Co(II) over other metal ions.
The electrode was successfully applied for determination of Co2+ in real samples and as an indicator electrode in potentiometric titration of Co2+ ions with EDTA.
相似文献
6.
Paraskevas D. Tzanavaras Theano D. Karakosta Pantelis G. Rigas Demetrius G. Themelis Anastasia Zotou 《Central European Journal of Chemistry》2012,10(5):1459-1463
The first HPLC method for the separation of three paraben preservatives (methyl-, ethyl- and propyl parabens) using a core-shell analytical column is reported in this study. The separation was completed in less than 8 min at a low flow rate of 0.4 mL min−1 and an isocratic mobile phase containing 20% acetonitrile as organic modifier. The backpressure was < 200 bar in all cases, enabling the usage of conventional HPLC equipment. The proposed analytical procedure was validated for linearity (0.5–20 μg L−1), limits of detection (15–43 μg L−1) and quantification (50–142 μg L−1), selectivity, within day (1.3–1.5%) and day-to-day (3.4–4.6%) precision and accuracy. The proposed method has been applied to the determination of the selected paraben preservatives in commercially available hygiene wipes. The mean percent recoveries were found to be in the range of 98.0–98.4%. 相似文献
7.
Dispersive liquid-liquid microextraction and liquid chromatographic determination of pentachlorophenol in water 总被引:1,自引:0,他引:1
Khalil Farhadi Mir A. Farajzadeh Amir A. Matin Paria Hashemi 《Central European Journal of Chemistry》2009,7(3):369-374
A simple and sensitive dispersive liquid-liquid microextraction method for extraction and preconcentration of pentachlorophenol
(PCP) in water samples is presented. After adjusting the sample pH to 3, extraction was performed in the presence of 1% W/V
sodium chloride by injecting 1 mL acetone as disperser solvent containing 15 μL tetrachloroethylene as extraction solvent.
The proposed DLLME method was followed by HPLC-DAD for determination of PCP. It has good linearity (0.994) with wide linear
dynamic range (0.1–1000 μg L−1) and low detection limit (0.03 μg L−1), which makes it suitable for determination of PCP in water samples.
相似文献
8.
In the present paper, an off-line preconcentration procedure for the determination of cadmium and lead by flame atomic absorption
spectrometry (FAAS) is proposed. Polyurethane foam (PUF) functionalized with o-aminophenol (o-AP) followed by Pyrazolone (Pyr)
packed in a minicolumn was used as a sorbent material. The metals were retained on the modified PUF, from which it could be
eluted and effectively preconcentrated. The detection limits were 0.072 and 0.016 μg L−1 for Pb and Cd respectively. Enrichment factors were 250 and 319 for lead and cadmium respectively. The procedure has been
applied successfully to metal determination in water samples, fish liver and reference material.
相似文献
9.
Dmitriy A. Golovko Virender K. Sharma Olga. V. Pavlova Elena. A. Belyanovskaya Igor. D. Golovko Victoria. I. Suprunovich Radek Zboril 《Central European Journal of Chemistry》2011,9(5):808-812
A new amperometric titration method was developed for quantitative determination of ferrate(VI) (FeVIO4
2−) in the 7.06×10−5−5.73×10−3 M concentration range. Chromium(III) hydroxide solution was used as the titrant. The diffusion current (Id) had a linear
relationship with the concentration of ferrate(VI) and slopes were dependent on the concentration of NaOH. The amperometric
titration could detect a lower concentration of ferrate(VI) than could potentiometric and colorimetric titrations. The method
was applied successfully to determine concentrations of ferrate(VI), generated electrochemically, in strong alkaline solutions.
相似文献
10.
Aleksandra Prichodko Kristina Jonusaite Vida Vickackaite 《Central European Journal of Chemistry》2009,7(3):285-290
A hollow fibre liquid phase microextraction for gas chromatographic determination of some p-hydroxybenzoic acid esters has
been developed. Chlorobenzene containing tetradecane as internal standard was used for the extraction. Optimized extraction
was carried out at room temperature for 40 min in the presence of 0.4 g mL−1 NaCl in the sample solution. Calibration was linear up to 30 mg L−1. Correlation coefficients were 0.996–0.998. Enrichment factors were 21, 95 and 154, and detection limits were 0.20, 0.03
and 0.01 μg mL−1 for methylparaben, ethylparaben and propylparaben, respectively. Reproducibility was acceptable with relative standard deviations
up to 11.7%. The technique was tested for water and urine analysis.
相似文献
11.
Ksenija R. Kumrić Tatjana M. Trtić-Petrović Ljubiša M. Ignjatović Jožef J. Čomor 《Central European Journal of Chemistry》2008,6(1):65-69
Lutetium has been determined by differential pulse anodic stripping voltammetry in an acidic solution containing Zn-EDTA.
Lutetium (III) ions liberated zinc (II), which was preconcentrated on a hanging mercury drop electrode and stripped anodically,
resulting in peak current linearly dependent on lutetium (III) concentration. Less than 0.4 ng mL−1 lutetium could be detected after a 2 min deposition.
相似文献
12.
M. H. Sorouraddin M. Iranifam A. Imani-Nabiyyi 《Central European Journal of Chemistry》2009,7(1):143-147
A simple and selective method for penicillin V potassium (PVK) determination by chemiluminescence (CL) was developed. Oxidation
of PVK by alkaline hydrogen peroxide produces CL, which is greatly enhanced by N, N-dimethyl formamide (DMF) and N-cetyl-N,N,N-trimethylammonium
bromide (CTMAB). Optimum conditions were established using luminometry. There is a linear relationship between the chemiluminescent
peak height and the amount of PVK within the range 0.5–129.5 mg L−1, with a detection limit of 0.2 mg L−1. The coefficient of variation was 1.2% for 40 mg L−1 PVK solution (n = 7). The method is very simple, has high sensitivity and good selectivity, and is usable for process control.
It was successfully utilized for the determination of PVK in pharmaceuticals and spiked human urine.
相似文献
13.
14.
Anuţa Câmpean Mihaela Tertiş Robert Săndulescu 《Central European Journal of Chemistry》2011,9(4):688-700
Electrochemical behaviour of some alkaloids, namely: caffeine, aminophylline, theophylline, codeine phosphate and papaverine
hydrochloride, that are in solution in various combinations or in the presence of other compounds contained in pharmaceuticals
or in real samples (urine) was investigated using cyclic voltammetry (CV), square-wave voltammetry (SWV) and differential
pulse voltammetry (DPV) on electrochemically activated glassy carbon electrode.
相似文献
15.
Sylwia Smarzewska Sławomira Skrzypek Barbara Bachowska Piotr Bałczewski Witold Ciesielski 《Central European Journal of Chemistry》2011,9(5):840-845
Electrochemical oxidation of methylthiomethyleneisoquinolinium chloride (MTMIQ), the first alkylthiomethyl substituted ammonium
salt, which is fully miscible with water has been investigated by voltammetric (SWV) method using glassy carbon electrode.
On the electrode, MTMIQ undergoes oxidation at the potential near Ep = 0.07V (vs. Ag/AgCl/3 M KCl). The influence of the pH
of buffers, amplitude, frequency, step potential on the received signal was studied. The best results were obtained with a
citrate buffer at a pH of 5. The oxidation peak current used for MTMIQ voltammetric determination was in the range of 2–8×10−5 mol L−1, LOD = 3.7×10−6, LOQ = 1.2×10−5. The product of the oxidation was accumulated at the working electrode and was investigated by spectroscopic method. Mechanistic
pathways of the oxidation have been proposed.
相似文献
16.
Charles A. Mebi Joshua J. Trujillo Anwar A. Bhuiyan 《Central European Journal of Chemistry》2012,10(4):1218-1222
A new organometallic complex coupling photoactive coumarin to a diironhexacarbonyl unit has been successfully prepared and its composition and electronic structure confirmed by elemental and spectroscopic analyses. Emission spectral analysis of the complex reveals photoinduced intramolecular electron transfer from coumarin to the iron-carbonyl moiety. The compound is electrochemically reduced at −1.24 V vs. Fc/Fc+. This reduction is irreversible, attesting to the instability of the complex. Electrochemical evolution of hydrogen in the presence of the complex has been studied and results are discussed. 相似文献
17.
Nitin A. Mirgane Sandip B. Kotwal Anil V. Karnik 《Central European Journal of Chemistry》2010,8(2):356-360
Ionic liquids (IL) are gaining importance as green solvents. Imidazolium ionic liquid [bmim]+[Cl]−, an environmentally benign solvent, was found to promote the Diels-Alder reaction between anthrone and maleimides at room
temperature with excellent yields. The ionic liquid played a dual role as solvent and catalyst.
相似文献
18.
Jinzhang Gao Yingying Zhang Jie Ren Ming Li Wu Yang 《Central European Journal of Chemistry》2010,8(3):602-606
A sensitive and convenient method for the determination of trace europium ions using an oscillating chemical reaction involving
Ce(IV) - KBrO3 - acetone - oxalic acid - H2SO4 was proposed. The results indicated that the changes in oscillating period (T) was linearly proportional to the negative
logarithmic concentration of Eu3+ (-log C) in the range of 1.41 × 10−8 ˜ 1.41 × 10−4 mol L−1 (r = 0.9982) with a detection limit of 1.04 × 10−9 mol L−1. The recoveries were limited to the range of 99.5% to 100.8%. Under the same conditions, other rare earth ions did not interfere
with the determination of Eu3+. In addition, a perturbation mechanism was also discussed briefly.
相似文献
19.
Violeta D. Mitic Snezana D. Nikolic Vesna P. Stankov-Jovanovic 《Central European Journal of Chemistry》2010,8(3):559-565
A kinetic spectrophotometric method for hydrazine determination in the range of 9.36×10−7 to 4.37×10−5 mol dm−3, based on the inhibitory effect of hydrazine on the oxidation of Victoria Blue 4- R by KBrO3, was developed and validated. Kinetic parameters are reported for both the indicating and the inhibiting reaction. The detection
limit was established as 9.98×10−8 mol dm−3. The selectivity of the proposed method was tested considering the influence of different ions that may be present in real
samples. The method was successfully applied for hydrazine determination in various samples (very pure water from the water-steam
system of a power plant and Isoniazid tablets, a pharmaceutical product).
相似文献
20.
Jinzhang Gao Dongyu Lv Wu Yang Xiaoxia Wei Jie Qu Hua Chen Hongxia Dai Jie Ren 《Central European Journal of Chemistry》2007,5(2):581-589
A convenient and sensitive method for determination of sulfanilamide (SNA) was described based on the Mn(II)-catalyzed oscillating
chemical reaction. Under optimum conditions, a linear relationship existed between the changes of oscillating period or amplitude
and the negative of logarithm of SNA concentration in the range of 4.27 × 10−8 mol ·L−1 ∼ 7.41 × 10−6 mol ·L−1 (RSD, 0.85%) and 9.33 × 10−8 mol ·L−1 ∼ 3.02 × 10−6 mol ·L−1 (RSD, 1.08%), respectively. The lower limit of detection was found to be 2.69 × 10−8 mol ·L−1 and 6.03 × 10−8 mol ·L−1, respectively.
相似文献