首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 157 毫秒
1.
We demonstrate ultrahigh-resolution optical coherence tomography (OCT) using continuum generation in an air-silica microstructure fiber as a low-coherence light source. A broadband OCT system was developed and imaging was performed with a bandwidth of 370 nm at a 1.3-mu;m center wavelength. Longitudinal resolutions of 2.5 microm in air and ~2 microm in tissue were achieved. Ultrahigh-resolution imaging in biological tissue in vivo was demonstrated.  相似文献   

2.
There is growing interest in the use of magnetic resonance imaging (MRI) to examine solid materials where the restricted motion of the probed spins leads to broad lines and short T(2) values, rendering many interesting systems invisible to conventional 2DFT pulsed imaging methods. In EPR T(2) seldom exceeds 0.1 mus and continuous-wave methods are adopted for spectroscopy and imaging. In this paper we demonstrate the use of continuous-wave MRI to obtain 2-dimensional images of short T(2) samples. The prototype system can image samples up to 50 mm in diameter by 60 mm long and has been used to image polymers and water penetration in porous media. Typical acquisition times range between 10 and 40 min. Resolution of 1 to 2 mm has been achieved for samples with T(2) values ranging from 38 to 750 mus. There is the possibility of producing image contrast that is determined by the material properties of the sample.  相似文献   

3.
We describe high-speed Fourier domain optical coherence tomography (OCT) using optical demultiplexers (ODs) for spectral dispersion. The OD enables separation of a narrow spectral band of 14 GHz (0.11 nm) from a broadband incident light at 256 different frequencies in 25.0 GHz intervals centered at 192.2 THz (1559.8 nm). OCT imaging of 60,000,000 axial scans per second was achieved through parallel signal acquisition using 256 balanced photoreceivers to simultaneously detect all the output signals from the ODs in a Fourier domain OCT system. OCT imaging at a 16 kHz frame rate, 1100 A-lines per frame, 3 mm depth range, and 23 microm resolution was demonstrated using a resonant scanner for lateral scanning.  相似文献   

4.
Adaptive-optics ultrahigh-resolution optical coherence tomography   总被引:4,自引:0,他引:4  
Merging of ultrahigh-resolution optical coherence tomography (UHR OCT) and adaptive optics (AO), resulting in high axial (3 microm) and improved transverse resolution (5-10 microm) is demonstrated for the first time to our knowledge in in vivo retinal imaging. A compact (300 mm x 300 mm) closed-loop AO system, based on a real-time Hartmann-Shack wave-front sensor operating at 30 Hz and a 37-actuator membrane deformable mirror, is interfaced to an UHR OCT system, based on a commercial OCT instrument, employing a compact Ti:sapphire laser with 130-nm bandwidth. Closed-loop correction of both ocular and system aberrations results in a residual uncorrected wave-front rms of 0.1 microm for a 3.68-mm pupil diameter. When this level of correction is achieved, OCT images are obtained under a static mirror configuration. By use of AO, an improvement of the transverse resolution of two to three times, compared with UHR OCT systems used so far, is obtained. A significant signal-to-noise ratio improvement of up to 9 dB in corrected compared with uncorrected OCT tomograms is also achieved.  相似文献   

5.
光纤型光学相干层析成像系统的研制   总被引:22,自引:7,他引:15  
光学相干层析(OCT)成像技术是一新近发展的高分辨力生物医学成像手段,能非侵入性地对活体内部的结构与生理功能进行可视化观察。采用宽带近红外光源,基于迈克耳孙干涉原理和外差探测方法,建立了单模光纤型光学相干层析成像系统,相干地提取从生物体内部返回的深度分辨的弹性散射光信息,并依此构筑了自然状态下活体组织的二维光学相干层析成像图像和三维光学相干层析成像图像。光纤化设计的光学相干层析成像系统紧凑、灵活,便于与光纤导管、内窥镜和其它成像装置的有机结合,以拓展其观察范围和应用领域。  相似文献   

6.
In Optical Coherence Tomography (OCT), both high axial and lateral resolutions are desired. While axial (z-axis) resolution is achieved by a broadband source, lateral (x-y axes) resolution is achieved by high NA lenses. However, high NA objectives result in decreased depth of focus (DOF). The small DOF makes it difficult to obtain single shot imaging of biological samples having large lateral dimension. In this work we incorporate special interfering phase mask allowing to extend the DOF of an OCT system and to allow imaging of samples without axial scanning.  相似文献   

7.
Tang S  Zhou Y  Chan KK  Lai T 《Optics letters》2011,36(24):4800-4802
A multiscale multiphoton microscopy (MPM) and optical coherence tomography (OCT) system has been developed using a sub-10 fs Ti:sapphire laser. The system performs cross-sectional OCT imaging over millimeter field-of-view and en-face high-resolution MPM imaging with submicrometer resolution from the same sample location. With fish cornea, we have demonstrated cross-sectional imaging of cornea tissue layers using OCT, and the zoom-in imaging of cells and collagen fibers in each layer using MPM. The multiscale MPM/OCT system shows the potential of a rapid coarse scan to search for abnormal regions and the subsequent fine zoom-in imaging for diagnosis.  相似文献   

8.
We report a case of multiple hemorrhagic cerebral metastases from papillary thyroid cancer, with reference to T(2)*-weighted gradient echo (GRE) magnetic resonance imaging (MRI). Small metastatic nodules were recognized as round nodules with signal loss on T(2)*-weighted GRE MRI, and were more pronounced compared with other sequences. Lesions were later confirmed as hemorrhagic on T(1)- and T(2)-weighted MRI. T(2)*-weighted GRE MRI was a sensitive tool for early detection of metastases displaying hemorrhagic changes.  相似文献   

9.
Fluorine nuclear magnetic resonance: calibration and system optimization   总被引:1,自引:0,他引:1  
Fluorine-19 magnetic resonance imaging (MRI) offers advantages for imaging organs and tissues. 19F is readily synthesized into a variety of compounds and offers the potential for in-vivo imaging as a complement to hydrogen MRI. The purpose of this work was to determine the minimum detection sensitivity for a fluorinated compound (CF3-CO2H) as a function of pulse sequence, interpulse times (TE, TI, and TR), gradient values and the number of data averages. CF3-CO2H was chosen because it has a single spectral line and exhibits a minimal frequency shift under the experimental conditions used for this experiment. A resistance MR scanner operating at a resonance frequency of 6.255 MHz was used for imaging both fluorine (.156 T) and hydrogen (.147 T). Critical factors determining the minimum detection sensitivity included system signal-to-noise ratio (S/N), acquisition time, relaxation times (T1, T2), and sample volume. Samples were measured over the range of 0.05 M to 20.0 M and showed a linear relationship between signal strength and concentration. The minimum detection sensitivity was 0.1 M. Use of higher static fields and optimized coils as well as improved system signal-to-noise ratios will improve detection sensitivity. We conclude that imaging of fluorine on low-field system is feasible, although it is necessary to optimize many parameters to maximize detection sensitivity.  相似文献   

10.
Proton magnetic resonance (1H magnetic resonance imaging (MRI)) images of human trabecular bone were acquired and discussed for two samples with different porosity. Three-dimensional 3D Spin Echo (3D SE) and Multi-Slice Multi-Echo (MSME) pulse sequences were examined. A very high slice resolution of (38 microm)2 was achieved (MSME). The intensity histograms were found useful for the characterization of the bone porosity. A spatial distribution of the spin-spin relaxation time T2 was monitored with the MSME pulse program. The work demonstrates the great potential of the proton MRI technique in the study of the trabecular bone morphology.  相似文献   

11.
Liu X  Cobb MJ  Chen Y  Kimmey MB  Li X 《Optics letters》2004,29(15):1763-1765
We developed a miniature endoscope that is capable of rapid lateral scanning and is suitable for real-time forward-imaging optical coherence tomography (OCT). The endoscope has an outer diameter of 2.4 mm, consisting of a miniature tubular lead zirconate titanate (PZT) actuator, a single-mode fiber-optic cantilever, and a graded-index lens. Rapid lateral scanning at 2.8 kHz is achieved when the fiber-optic cantilever is resonated with the PZT actuator. This allows OCT imaging to be performed by fast lateral beam scanning followed by slow depth scanning, which is different from the conventional OCT imaging sequence. Real-time OCT imaging with the endoscope operated in the new image acquisition sequence at 6 frames/s is demonstrated.  相似文献   

12.
We have developed a dual-channel optical coherence tomography-Indocyanine Green dye (OCT-ICG) fluorescence system based on a previously reported ophthalmic OCT confocal imaging system. The confocal channel is tuned to the fluorescence wavelength range of the ICG, and light from the same optical source is used to generate the OCT image and to excite the ICG fluorescence. The system enables the clinician to visualize simultaneously en face OCT slices and corresponding ICG angiograms of the ocular fundus, displayed side by side. C-scan (constant depth) and B-scan (cross section) images are collected by a fast en face scan (T scan). The pixel-to-pixel correspondence between the OCT and angiography images allows the user to capture OCT B scans precisely at selected points on the ICG confocal images.  相似文献   

13.
The increasing availability of rodent models of human cardiovascular disease has led to a need to translate noninvasive imaging techniques such as magnetic resonance imaging (MRI) from the clinic to the animal laboratory. The aim of this study was to develop phantoms simulating the short-axis view of left ventricular motion of rats and mice, thus reducing the need for live animals in the development of MRI. Cylindrical phantoms were moulded from polyvinyl alcohol (PVA) Cryogel and attached via stiff water-filled tubing to a gear pump. Pulsatile distension of the phantoms was effected by suitable programming of the pump. Cine MRI scanning was carried out at 7 T and compared with in vivo rodent cardiac imaging. Suitable pulsatile performance was achieved with phantoms for which the PVA material had been subjected to two freeze-thaw cycles, resulting in T1 and T2 relaxation time constants of 1656±124 ms and 55±10 ms, respectively. For the rat phantom operating at 240 beats per min (bpm), the dynamic range of the outer diameter was from 10.3 to 12.4 mm with the wall thickness varying between 1.9 and 1.2 mm. Corresponding figures for the mouse phantom at 480 bpm were outer diameter range from 5.4 to 6.4 mm and wall thickness from 1.5 to 1.2 mm. Dynamic cardiac phantoms simulating rodent left ventricular motion in the short-axis view were successfully developed and compared with in vivo imaging. The phantoms can be used for future development work with reduced need of live animals.  相似文献   

14.
We describe a lesion with the magnetic resonance imaging (MRI) characteristics of a glioblastoma mutiforme and demonstrate how perfusion MRI and proton MR spectroscopic imaging can be used to differentiate necrotizing cerebritis from what appeared to be a high-grade glioma. A 43-year-old woman presented to her physician complaining of progressive visual disturbance and headache for several weeks. Conventional MRI demonstrated a parietal peripherally enhancing mass with central necrosis and moderate to severe surrounding T2 hyperintensity, suggesting an infiltrating high-grade glioma. However, advanced imaging, including dynamic susceptibility contrast MRI (DSC MRI) and magnetic resonance spectroscopic imaging (MRSI), suggested a nonneoplastic lesion. The DSC MRI data demonstrated no hyperperfusion within the lesion and surrounding T2 signal abnormality, and the MRSI data showed overall decrease in metabolites in this region, except for lactate. Because of the aggressive appearance to the lesion and the patients' worsening symptoms, a biopsy was performed. The pathologic diagnosis was necrotizing cerebritis. After the commencement of steroid therapy, imaging findings and patient symptoms improved. This report will review the utility of advanced imaging for differentiating inflammatory from neoplastic appearing lesions on conventional imaging.  相似文献   

15.
An L  Wang RK 《Optics letters》2007,32(23):3423-3425
We report a new yet simple method to achieve full-range complex Fourier-domain optical coherence tomography (OCT) for in vivo imaging. The method utilizes a scanner that is dedicated for lateral scanning in the system to introduce a constant carrier frequency into the OCT spectral interferograms during the scanning. This is achieved by simply offsetting the sampling beam spot away from the pivot point of the scanning mirror. We demonstrate the method experimentally for in vivo full-range imaging of the anterior segment of a human eye. The method is free from complex conjugate mirror image and self-cross-correlation image artifacts.  相似文献   

16.
The successful translation of stem-cell therapies requires a detailed understanding of the fate of transplanted cells. Magnetic resonance imaging (MRI) has provided a noninvasive means of imaging cell dynamics in vivo by prelabeling cell with T(2) shortening iron oxide particles. However, this approach suffers from a gradual loss of sensitivity since active cell mitosis could decrease the cellular contrast agent (CA) concentration below detection level. In addition, the interpretation of images may be confounded by hypointensities induced by factors other than this CA susceptibility effect (CASE). We therefore examined the feasibility of exploiting the phase information in MRI to increase the sensitivity of cellular imaging and to differentiate the CASE from endogenous image hypointensity. Phase aliasing and the B(0) field inhomogeneity effect were removed by applying a reliable unwrapping algorithm and a high-pass filter, respectively, thus delineating phase variations originating from high spatial frequencies due to the CASE. We found that the filtered phase map detects labeled cells with high sensitivity and can readily differentiate the cell migration track from the white matter, both of which are hypointense in T(2)-weighted magnitude images. Furthermore, an approximate fivefold contrast-to-noise ratio enhancement can be achieved with an MRI phase map over conventional T(2)-weighted magnitude images.  相似文献   

17.
设计并合成了结构为TPP-Lys(Acp-DOTA-Gd)-COOH(简称Gd-DOTA-TPP)的小分子磁共振探针,通过电转染的方式用探针标记人源脐带间充质干细胞(hMSCs).11.7 T磁共振成像(MRI)扫描结果表明,Gd-DOTA-TPP标记的hMSCs在细胞内Gd含量为9×109 Gd/cell时,T2加权信号强度即可低至背景信号强度,呈现较强暗信号.将Gd-DOTA-TPP标记的hMSCs移植入小鼠脑室,可明显提高移植干细胞在MRI设备上的检测灵敏度,检测限可低至103个细胞.  相似文献   

18.
In this paper, a digital wireless transmission system based on 802.11b standard for magnetic resonance imaging (MRI) application is designed and built for the first time to eliminate the interference aroused by coil array cables. The analysis shows that the wireless receiver has a very high sensitivity to detect MRI signals. The modulation technique of differential quadrature phase shift keyed (DQPSK) can be applied to MRI data transmission with rate of 2 Mbps and bandwidth of 2 MHz. The bench test verifies that this wireless link has a dynamic range over 86 dB supporting up to 3 T MRI system data transmission. The 2D spin echo imaging of phantom is performed and the SNR of the image obtained by the wireless transmission can be comparable with that got by the coaxial cables.  相似文献   

19.
王玲  丁志华 《光子学报》2008,37(2):351-355
提出利用快速扫描光学延迟线(Rapid Scanning Optical Delay Line,RSOD)作为光学相干层析成像(Optical Coherence Tomography,OCT)系统的相位调制器,并采用正弦驱动方式(谐振扫描)来提高扫描频率,进而实现高频相位调制的方法.介绍了基于RSOD相位调制器的干涉信号包络解调方法,分析了大振镜低频率线性驱动、小振镜高频线性驱动和大振镜高速正弦驱动三种实施方案对OCT性能的影响,并针对谐振扫描方案中轴向扫描的非线性提出了图像畸变定量校正的方法.结果表明:RSOD大振镜谐振扫描的模式能够兼顾系统成像速度、成像范围以及系统信噪比的要求,是一种行之有效的相位调制方法.  相似文献   

20.
During the pandemic of novel coronavirus infection (COVID-19), computed tomography (CT) showed its effectiveness in diagnosis of coronavirus infection. However, ionizing radiation during CT studies causes concern for patients who require dynamic observation, as well as for examination of children and young people. For this retrospective study, we included 15 suspected for COVID-19 patients who were hospitalized in April 2020, Russia. There were 4 adults with positive polymerase chain reaction (PCR) test for COVID-19. All patients underwent magnetic resonance imaging (MRI) examinations using MR-LUND PROTOCOL: Single-shot Fast Spin Echo (SSFSE), LAVA 3D and IDEAL 3D, Echo-planar imaging (EPI) diffusion-weighted imaging (DWI) and Fast Spin Echo (FSE) T2 weighted imaging (T2WI). On T2WI changes were identified in 9 (60,0%) patients, on DWI – in 5 (33,3%) patients. In 5 (33,3%) patients lesions of the parenchyma were visualized on T2WI and DWI simultaneously. At the same time, 4 (26.7%) patients had changes in lung tissue only on T2WI. (P(McNemar) = 0,125; OR = 0,00 (95%); kappa = 0,500). In those patients who had CT scan, the changes were comparable to MRI. The results showed that in case of CT is not available, it is advisable to conduct a chest MRI for patients with suspected or confirmed COVID-19. Considering that T2WI is a fluid-sensitive sequence, if imaging for the lung infiltration is required, we can recommend the abbreviated MRI protocol consisting of T2 and T1 WI. These data may be applicable for interpreting other studies, such as thoracic spine MRI, detecting signs of viral pneumonia of asymptomatic patients. MRI can detect features of viral pneumonia.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号