首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 281 毫秒
1.
A radiochemical neutron activation analysis using a rare earth group separation scheme has been used to measure ultratrace levels of rare earth elements (REE) in IAEA Human Hair (HH-1), IAEA Animal Bone (H-5), NBS Bovine Liver (SRM 1577), and NBS Orchard Leaf (SRM 1571) standards. The REE concentrations in Human Hair and Animal Bone range from 10–8 g/g to 10–11 g/g and their chondritic normalized REE patterns show a negative Eu anomaly and follow as a smooth function of the REE ionic radii. The REE patterns for NBS Bovine Liver and Orchard Leaf are identical except that their concentrations are higher. The similarity among the REE patterns suggest that the REE do not appear to be fractionated during the intake of biological materials by animals or humans.  相似文献   

2.
稀土在工业诸多领域中发挥着关键作用,在增材制造材料和介电材料等高新技术领域均显示出可期的应用前景。稀土元素的分离是衔接稀土资源与高性能稀土功能材料的关键过程,所以高效提纯稀土元素变得尤为重要。本文梳理了化学沉淀法、离子交换与吸附法、萃取色层法、溶剂萃取法、液膜分离法这些经典方法和化学气相传输法、氧化还原法、萃取沉淀法、微生物法、非平衡溶剂萃取法这些新技术方法的优缺点和适用性,侧重分析了这些技术方法在节能减排方面的最新研究情况,并展望了稀土分离提纯领域的重点发展方向,以期为稀土资源的绿色高效开发利用提供依据和借鉴。  相似文献   

3.
Ramanaiah GV 《Talanta》1998,46(4):533-540
A rapid method is described for the determination of yttrium, scandium, and other rare earth elements (REEs) in uranium-rich geological samples (containing more than 0.1% U) and in pitch blende type of samples by inductively coupled plasma atomic emission spectrometry (ICP-AES) after separation of uranium by selective precipitation of the analytes as hydroxides using H(2)O(2)/NaOH in the presence of iron as carrier. Uranium goes into solution as soluble peruranate complex. The precipitated rare earth hydroxides (including Y and Sc) are filtered and dissolved in hydrochloric acid prior to their aspiration into plasma for their individual estimation after selecting interference free REE emission lines. The method has also been applied to some international reference standards like SY-2 and SY-3 (by doping a known amount of uranium) along with one in-house pitch blende sample and the REE values were found to be in agreement with the most usable values, offering an R.S.D. of 1-8.8% for all the REEs', Y and Sc. The method compared well, with the well- established cation exchange separation procedure.  相似文献   

4.
An analytical scheme of radiochemical neutron activation for the sequential determination of ultra-trace rare earth elements (REEs) and highly siderophile elements (HSEs) in geological and cosmochemical samples is presented. Using this procedure, several selected elements of REEs and HSEs were successively determined for geological reference samples and olivine crystals separated from pallasite meteorites. Based on the data for geological reference samples, it was concluded that the procedure presented in this study could yield data usable for cosmochemical discussion of the genesis of pallasite meteorites.  相似文献   

5.
Delayed neutron activation analysis (DNAA) is a rapid and sensitive analytical method for the determination of fissile elements in a variety of samples. The present work describes two different analytical applications of delayed neutron activation for the analysis of biological and environmental samples, respectively. In the first application, DNAA was utilized to determine the natural uranium content in NIST standard reference materials (SRM) 1547 peach leaves and 1573a tomato leaves. Measured uranium mass fractions are comparable to the non-certified values listed on the certificates for these materials. In the second application, delayed neutron activation is coupled with instrumental neutron activation analysis (INAA) for the measurement of rare earth elements (REE) (cerium, lanthanum, neodymium, and ytterbium) in NIST SRM 2586, Trace Elements in Soil Containing Lead from Paint. DNAA was utilized to determine the uranium mass fraction in SRM 2586 for the subsequent application of a correction factor to account for cerium, lanthanum, and neodymium produced as part of the INAA irradiation. Measured and corrected mass fractions for the REEs described here are all within the uncertainty limits provided on the NIST certificate for SRM 2586. These results and the demonstrated sensitivity of the DNAA system establish and validate the use of this method for the determination of REEs and for potential nuclear forensics applications.  相似文献   

6.
A new sorbent, maleic acid grafted polytetrafluoroethylene fiber (MA-PTFE), was prepared and evaluated for on-line solid-phase extraction coupled with inductively coupled plasma mass spectrometry (ICP-MS) for fast, selective, and sensitive determination of (ultra)trace rare earth elements (REEs) in environmental samples. The REEs in aqueous samples at pH = 3.0 were selectively extracted onto a microcolumn packed with the MA-PTFE fiber, and the adsorbed REEs were subsequently eluted on-line with 0.9 mol l(-1) HNO3 for ICP-MS determination. The new sorbent extraction system allows effective preconcentration and separation of the REEs from the major matrix constituents of alkali and alkali earth elements, particularly their separation from barium that produces considerable isobaric interferences of 134Ba16O1H+, 135Ba16O+, 136Ba16O1H+, and 137Ba16O+ on 151Eu+ and 153Eu+. With the use of a sample loading flow rate of 7.4 ml min(-1) for 120 s preconcentration, enhancement factors of 69-97 and detection limits (3s) of 1-20 pg l(-1) were achieved at a sample throughput of 22 samples h(-1). The precision (RSD) for 16 replicate determinations of 50 ng l(-1) of REEs was 0.5-1.1%. The developed method was successfully applied to the determination of (ultra)trace REEs in sediment, soil, and seawater samples.  相似文献   

7.
研究了电感耦合等离子体质谱(ICP-MS)测定大气颗粒物中痕量稀土元素(REEs)的分析方法。在微波条件下,采用HNO3 + H2O2(3 + 1)混合介质能快速而有效地分解颗粒物样品。详细讨论了测定稀土元素的质谱干扰。通过分析不同粒径颗粒物中稀土元素的含量,初步探讨了大气颗粒物中稀土元素的分布规律。结果表明:颗粒物试样的粒径越小,稀土元素的含量越高。分析方法的检出限为0.7~2.8pg/mL,用于大气颗粒物国际标样(SRM 1648)中稀土元素分析,结果与推荐值有良好的一致性。  相似文献   

8.
This study developed a methodology to analyze trace rare earth elements (REEs) in geological materials by capillary electrophoresis (CE). Changed from dilute HNO3 into a water medium by heating, REE ions are detectable at approximately 2 ng mL(-1). In the presence of coexisting elements from geological samples, REE separations were carried out. After sample fusion with Na2O2 and interference separation with ammonium pyrrolidinedithiocarbamate chelate, REE analytes were coprecipitated with Mg(OH)2 at pH 8.5, and then prepared into a water medium for CE determination. Using the standard addition method, this protocol was validated by analyses with better than 5% precision. This method was applied to geological materials; the REE results are in consistence with their certified values. With electrokinetic injection, internal standard (IS) selected among lanthanides is a prerequisite of high-quality REE data. An approach was proposed to derive the IS content for further correcting its contribution from unknown samples.  相似文献   

9.
A new chelating resin, silica gel loaded with 1-phenyl-3-methyl-4-benzoylpyrazol-5-one (PMBP), was prepared and used for the preconcentration of trace amounts of rare earth elements (REEs) in water samples prior to their determination by inductively coupled plasma atomic emission spectrometry (ICP-AES). REEs (La, Eu, Yb and Y) were quantitatively retained on the column packed with modified silica gel in the pH range 5 - 8 and separated from the matrix, and then recovered by eluting with 2.0 mol L(-1) HNO3. The adsorption capacity of modified silica gel for La, Eu, Yb and Y was 0.208, 0.249, 0.239 and 0.224 mmol g(-1), respectively. The method has been successfully applied for the determination of La, Eu, Yb and Y in geological and environmental samples with satisfactory results.  相似文献   

10.
A solid phase collection/concentration method using anion exchanger filters and a small syringe packed with chelating resin fibers is adopted as a preconcentration tool for trace elements and a separation tool for matrices in aqueous samples prior to the measurement by inductively coupled plasma-mass spectrometry (ICP-MS). The effects of fiber volume, sample volume, eluent volume, and sample flow rate on metal recoveries were investigated in detail to obtain optimum pretreatment conditions. Several heavy metals (HMs) such as, V, Mn, Co, Ni, Cu, Zn, Ga, Cd, Pb, Th and U, as well as 14 rare earth elements (REEs) in sample solutions at pH 6 were quantitatively collected on the solid phase. These adsorbed elements were completely recovered by eluting with 2 ml of 1.0 M nitric acid. At pH 6, more than 99% of alkali and alkaline earth metals in sample solutions were eliminated. The proposed method was evaluated by analyzing two standard reference materials (SRM): peach leaves (NIST 1547) and pond sediment (NIES No. 2). The solid samples were decomposed by microwave-heating and pressurizing acid digestion technique, and then treated by the proposed syringe-type pretreatment method, followed by the ICP-MS measurement. The analytical results for HMs in the SRMs obtained by the present method agreed well with the certified values.  相似文献   

11.
Cao X  Yin M  Li B 《Talanta》1999,48(3):517-525
A method was developed for the determination of rare earth impurities in high purity Gd(2)O(3) by inductively coupled plasma mass spectrometry (ICP-MS). The matrix suppression effect of Gd(2)O(3) on signals of rare earth impurities was compensated for by Re internal standardization. The spectra overlap interferences from GdH, GdO, GdOH(n) (n=1-3) on Tb, Tm, Yb and Lu were eliminated by 2-thylhexylhydrogen-2-ethylhexy phosphonate (EHEHP) extraction chromatographic separation. The detection limits for REEs were 0.005-0.017 ng ml(-1) in solution and 0.002-0.05 mug g(-1) in solid. Recoveries of spiked sample for REEs were from 88 to 121% with the precision of 1.0-7.5% RSD. Determination of trace REEs in two Gd(2)O(3) samples were performed. The method can be applied to analysis of 99.99-99.9999% high purity Gd(2)O(3).  相似文献   

12.
The “true detection limit” CL,true was measured by a method proposed by Boumans et al. for 10 prominent lines of La, Ce, Pr, Nd and Sm, the most abundant rare earth elements (REEs) in geological samples. It is demonstrated how spectral interferences can increase of CL,true. The spectra were excited in an argon arc plasma jet with evaporation powders of five complex natural samples. The data show that there is a significant increase of CL,true in real samples containing large concentrations of such elements as Ti, Zr, Cr, Nb, Ta and REEs emitting complex spectra.  相似文献   

13.
A method was developed for the determination of all rare earth elements (REEs) at sub ng g−1 levels in human hair (GBW 09101, SRM, Republic of China) and wheat flour (GBW 08503, SRM, Republic of China) by Inductively coupled plasma mass spectrometry (ICP-MS). The values obtained by dry ashing and microwave oven digestion procedures were compared with those obtained by traditional open vessel acid digestion method. The validity of the analytical procedure was examined by analyzing spiked samples and two vegetables (GBW 07603 and GBW 07605, SRMs, Republic of China). The results are satisfactory. The detection limits for 14 REEs ranged from 0.0039 to 0.0003 ng cm−3 in solution and the quantification limits ranged from 0.16 to 0.01 ng g−1 in solid sample. The precision for most REEs were less than 10% RSD.  相似文献   

14.
A method has been developed for the analysis of rare earth elements (REEs) in kimberlite samples using inductively coupled plasma mass spectrometer (ICP-MS). The samples were dissolved using sodium peroxide fusion and after appropriate dilutions the solutions were analyzed using ICP-MS. The paper presents the concentration of rare-earth elements as determined by ICP-MS in eight kimberlite samples from Central India. The method was validated using certified reference materials STSD-1 and STSD-2 from Canadian Certified Reference Material Project. The method detection limit of various REEs varies from 0.12 to 1.54?mg?kg?1. The total REE concentrations range from 418 to 726?mg?kg?1 and fall within the interval of those reported in the literature for kimberlites. Despite the marked difference in the REE contents, all the analyzed samples show similar REE patterns that resemble those for kimberlites. In order to compare ICP-MS results, the samples were analyzed using instrumental neutron activation analysis which is a reference method for determination of REEs in geological samples.  相似文献   

15.
Summary A method for the determination of elements in liquids using inductively coupled plasma mass spectrometry (ICP-MS) is described. The different possibilities and problems together with instrumental parameters are reviewed. After the dissolution step samples are analyzed directly without any preconcentration. Detection limits for 53 elements have been tested and are found to be less than 0.1 ng/ml. Monoisotopic elements can be detected at levels less than 0.05 ng/ml. Interference problems have been studied and hints are given to predict molecular species using algorithm implemented in software packages. The application to trace element analysis in the geological field is demonstrated with a basalt reference sample to verify figures of merit for this method. Accuracy is checked with a NBS SRM steel sample.
Erfahrungen und Möglichkeiten mit der Anwendung eines induktiv gekoppelten Plasma/Massenspektrometer Systems
  相似文献   

16.
The “true detection limit” CL,true was measured by a method proposed by Boumans et al. for 10 prominent lines of La, Ce, Pr, Nd and Sm, the most abundant rare earth elements (REEs) in geological samples. It is demonstrated how spectral interferences can increase of CL,true. The spectra were excited in an argon arc plasma jet with evaporation powders of five complex natural samples. The data show that there is a significant increase of CL,true in real samples containing large concentrations of such elements as Ti, Zr, Cr, Nb, Ta and REEs emitting complex spectra. Received: 17 June 1997 / Revised: 20 October 1997 / Accepted: 26 October 1997  相似文献   

17.
An ion-exchange ICP-AES method for the determination of 14 rare earth elements (REEs) and Y in geological materials is described. The separation of REEs from Ba using a Dowex 50W-X8 cation resin is especially considered since Ba is an excellent internal standard for REE determination by this technique. Although total recovery with either HCl or HNO3 may be achieved, it is advantageous to use both acids sequentially. Volume and concentration of the acids are optimized attaining a quantitative separation of REEs from Ba by the introduction of the sample solution in a 1.75 mol/l HCl medium, followed by elution with 2 mol/l HNO3 to remove matrix elements and with 7 mol/l HNO3 to elute the analytes. The total elution volume is significantly reduced without decreasing the efficiency. The behaviour of the matrix constituents under the selected conditions is also studied, evaluating their elution percentages in each step. The final solution obtained contains only the REEs and Y, with the bulk of Sc and minor amounts of Cr, Fe, Hf and Ta. Experimental data for 5 geological reference standards (NIM-G, GSP-1, AGV-1, NIM-L and NIM-S) are reported. Good agreement between the present results and previously accepted values by various analytical techniques is observed.  相似文献   

18.
《Analytical letters》2012,45(11):2105-2115
Abstract

Systematic investigations were carried out into the sorption of rare earth elements (REEs) on carbon nonofibers (CNFs) by inductively coupled plasma mass spectrometry (ICP‐MS). The experimental parameters for preconcentration of REEs, such as pH, sample flow rate and volume, eluent concentration, and interfering ions on preconcentration of REEs have been examined in detail. The studied metal ions can be adsorbed quantitatively on CNFs in a pH range from 2.0 to 5.0, and then eluted completely with 0.5 mol l?1 HNO3. Based on the above facts, a novel method using a microcolumn packed with carbon nanofibers as an adsorption material was developed for the separation and preconcentration of REEs prior to their determination by ICP‐MS. The proposed method has been successfully applied to the determination of light (La), medium (Eu and Gd) and heavy (Yb) rare earth elements in real sample with the recovery more than 90%. In order to validate this method, two certified reference materials of tea leaves (GBW 07605) and mussel (GBW 08571) were analyzed, and the determined values are in good agreement with the certified values.  相似文献   

19.
A method of glow discharge atomic emission spectroscopy (GD-AES) is described for the determination of rare earth elements (REEs) after separation and preconcentration by micro-column packed with immobilized 1-phenyl-3-methyl-4-benzoyl-5-pyrazone (PMBP) on microcrystalline naphthalene. The graphite electrode with solution residue on its surface was used as a cathode. Various factors (the form of cathode, working condition) influencing the determination of the analytes were studied in detail. Under the experimental conditions selected, the detection limits for the determination of La, Nd, Eu, Dy and Y are 0.24, 0.32, 0.01, 0.07 and 0.06 μg/mL, respectively, with relative standard deviations (RSDs) in the range of 5–10%. The method was applied to determine La, Nd, Eu, Dy and Y in geological samples, and the analytical results are in good agreement with the reference values.  相似文献   

20.
A simple and effective procedure is developed to avoid the spectral interference from light rare earth elements (REEs) and barium polyatomic ions on some rare earth elements in inductively coupled plasma mass spectrometry (ICP-MS) by combining algebraic correction with AG50W-×8 cation exchangeable chromatography. Algebraic correction is made to reduce the spectroscopic overlap interference of 141Pr16O and 143Nd16O on 157Gd and 159Tb. The spectroscopic overlap interference of BaO+ and BaOH+ on some middle REEs are overcome by separation of REEs from barium with AG50W-×8 cation exchangeable chromatography. Prior to the determination, REEs are separated from complicated matrix samples using AG50W-×8 cation exchangeable resin. Ba is eluted with 2 mol/l HNO3 solution. REEs are retained and could then be eluted with 5 mol/l HNO3 solution. Recoveries for REEs are from 96 to 110%. More than 99.5% of Ba in the sample is removed, ensuring that the spectral interference from barium polyatomic ions on some middle REEs such as Nd, Sm, Eu and Gd are eliminated. The potential of the proposed method is evaluated by analysis of Certified Reference Materials (CRMs). Results show that experimental data are in good agreement with the certified values. The new technique has been successfully employed for the determination of REEs in practical soil and plant samples.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号