首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
The graphene nanosheets/manganese oxide nanoparticles modified glassy carbon electrode (GC/GNSs/MnOx) was simply prepared by casting a thin film of GNSs on the GC electrode surface, followed by performing electrodeposition of MnOx at applied constant potential. The GC/GNSs/MnOx modified electrode shows high catalytic activity toward oxidation of L ‐cysteine. Hydrodynamic amperometry determination of L ‐cysteine gave linear responses over a concentration range up to 120 µM with a detection limit of 75 nM and sensitivity of 27 nA µM?1. The GC/GNSs/MnOx electrode appears to be a highly efficient platform for the development of sensitive, stable and reproducible L ‐cysteine electrochemical sensors.  相似文献   

2.
The sol‐gel technique was used to construct tin pentacyanonitrosylferrate (SnPCNF) modified composite carbon ceramic electrode (CCE). This involves two steps: construction of CCE containing metallic Sn powder and then electrochemical creating of SnPCNF on the surface of CCE. The SnPCNF modified CCE (SnPCNFlCCE) was characterized by energy‐dispersive X‐ray (EDX), FTIR and cyclic voltammetry (CV) techniques. The SnPCNF film showed electrocatalytic activity toward the oxidation of L ‐cysteine. A linear calibration plot was obtained over the L ‐cysteine concentration range 1–51 μM using chronoamperometry. L ‐cysteine was determined amperometrically at the surface of this modified electrode. The detection limit (for a signal to noise of 3) and sensitivity were found to be 0.62 μM and 126 μA/mM, respectively.  相似文献   

3.
Brilliant blue FCF‐modified glassy carbon electrodes have been prepared by cycling the Nafion (or poly(diallyldimethylammonium chloride) (PDDAC)) coated electrodes repeatedly 15 cycles in brilliant blue FCF (BB FCF) dye solution. The BB FCF molecules are incorporated into Nafion coating by cycling the film‐covered electrode between +0.3 to 1.2 V (vs. Ag/AgCl) in pH 1.5 BB FCF solution while PDDAC‐coated electrode cycled between 0 to ?1.0 V (vs. Ag/AgCl) in pH 6.5 BB FCF solution to immobilize the dye. Electrostatic interaction between dye molecule and PDDAC was predominant in PDDAC coating whereas immobilization of dye in Nafion film attributed to the combined effect of electrostatic and hydrophobic interactions. The voltammetric features of BB FCF‐modified electrodes resemble that of surface‐confined redox couples. The peak potentials of BB FCF‐incorporated PDDAC‐coated electrode were shifted to more positive potential region with decreasing pH of contacting solution. BB FCF‐modified electrodes showed electrocatalytic activity towards reduction of oxygen and oxidation of L ‐cysteine with significant decease of overvoltage compared to unmodified electrode. The BB FCF‐modified Nafion‐coated electrode was tested for its analytical applications toward determination of L ‐cysteine. The linear range of calibration plot at BB FCF‐modified Nafion‐coated electrode is 10 to 100 μM, which coincides with L ‐cysteine levels in biological fluids. Sensitivity and detection limit of the electrode are 111 nA μM?1 and 0.5 μM, respectively.  相似文献   

4.
The electrochemical behavior of L ‐cysteine studied at the surface of ferrocenedicarboxylic acid modified carbon paste electrode (FDCMCPE) in aqueous media using cyclic voltammetry, differential pulse voltammetry and double potential step chronoamperometry. It has been found that under optimum condition (pH 8.00) in cyclic voltammetry, the oxidation of L ‐cysteine occurs at a potential about 200 mV less positive than that of an unmodified carbon paste electrode. The kinetic parameters such as electron transfer coefficient, α, and catalytic reaction rate constant, kh were also determined using electrochemical approaches. The electrocatalytic oxidation peak current of L ‐cysteine showed a linear dependent on the L ‐cysteine concentration and linear analytical curves were obtained in the ranges of 3.0×10?5 M–2.2×10?3 M and 1.5×10?5 M–3.2×10?3 M of L ‐cysteine concentration with cyclic voltammetry (CV) and differential pulse voltammetry (DPV) methods respectively. The detection limits (3σ) were determined as 2.6×10?5 M and 1.4×10?6 M by CV and DPV methods.  相似文献   

5.
A glassy carbon (GC) electrode modified with silver pentacyanonitrosylferrate (AgPCNF) film as a redox mediator was fabricated. Cyclic voltammetry was used to study the redox property of AgPCNF modified electrode. The modified electrode showed a well‐defined redox couple due to [AgIFeIII/II(CN)5NO]1‐/2‐system. The effects of scan rates, supporting electrolytes and solution pHs were studied on the electrochemical behavior of the modified electrode. The feasibility of using the AgPCNF modified electrode to measure L ‐cysteine was investigated. It showed an excellent electrocatalytic activity towards the oxidation of L ‐cysteine and the anodic currents were proportional to the L ‐cysteine concentration in the range of 0.1 μM to 20 μM, the linear regression equation is Ipa(μA) = ‐68.58 ‐ 5.78CL ‐cysteine (μM), with a correlation coefficient 0.998 for N = 23. The detection limit was down to 3.5 × 10‐8 M (three times the ratio of signal to noise).  相似文献   

6.
《Electroanalysis》2005,17(22):2043-2051
The electrochemical behavior of L ‐cysteine studied at the surface of ferrocenecarboxylic acid modified carbon paste electrode (FCMCPE) in aqueous media using cyclic voltammetry and double step potential chronoamperometry. It has been found that under optimum condition (pH 7.00) in cyclic voltammetry, the oxidation of L ‐cysteine is occurs at a potential about 580 mV less positive than that an unmodified carbon paste electrode. The kinetic parameters such as electron transfer coefficient, α and catalytic reaction rate constant, Kh were also determined using electrochemical approaches. The electrocatalytic oxidation peak current of L ‐cysteine showed a linear dependent on the L ‐cysteine concentration and linear calibration curves were obtained in the ranges of 10?5 M–10?3 M and 4.1×10?8 M–3.7×10?5 M of L ‐cysteine concentration with cyclic voltammetry (CV) and differential pulse voltammetry (DPV) methods respectively. The detection limits (2δ) were determined as 2.4×10?6 M and 2.5×10?8 M by CV and DPV methods. This method was also examined for determination of L ‐cysteine in some samples, such as Soya protein powder, serum of human blood by using recovery and standard addition methods.  相似文献   

7.
《Electroanalysis》2004,16(11):881-887
s‐Adenosyl‐L ‐methionine (SAMe) is an adenosine analogue with therapeutical activity against affective disorders and liver dysfunctions. It can be oxidized on graphite electrode yielding a strongly adsorbed electroactive oxidation product for which a quinone‐imine structure is proposed. This compound is capable of electrocatalyzing the NADH oxidation at low potentials, lowering the overvoltage by about 300 mV. An amperometric method for NADH determination at +0.1 V (Ag|AgCl|KClsat) is developed using an oxidized‐SAMe‐modified electrode in pH 9. Linear calibration plots were obtained with a detection limit of 2.4 nM. The electrode response time and the relative standard deviation of the slope of the calibration plot for 5 different modified electrodes were 12 s and 5.6% respectively. The catalytic scheme also provides the first method to determine SAMe itself by adsorptive differential pulse voltammetry. The linear range was found to be 42.4–424 nM with a reproducibility of 6.9%. The method was applied to SAMe determination in a pharmaceutical formulation.  相似文献   

8.
Glassy carbon electrode modified with phosphotungstate‐doped‐glutaraldehyde‐cross‐linked poly‐L ‐lysine (PLL‐GA‐PW) film was employed for iodate determination. The PLL‐GA‐PW film electrode shows excellent electrocatalytic activity towards iodate reduction with significant reduction of overpotential. Under optimized experimental conditions, a linear range from 5×10?8 to 2.27×10?2 M with a sensitivity of 61.75 μA mM?1 was obtained. Possible interfering species, in iodate determination, were evaluated and the applicability of proposed sensor for iodate estimation in table salt was also demonstrated. The PLL‐GA‐PW film electrode shows fast response, wider linear range, and good selectivity and stability.  相似文献   

9.
Silicomolybdate‐doped‐glutaraldehyde‐cross‐linked poly‐L ‐lysine (PLL‐GA‐SiMo) film modified glassy carbon electrode was successfully prepared by means of electrostatically trapping the silicomolybdate anion in PLL‐GA cationic coating. The PLL‐GA‐SiMo film was stable and the charge transport through the film was fast. The modified electrode shows excellent electrocatalytic activity towards bromate reduction with significant reduction of overpotential. In amperometric determination of bromate, the calibration plot was linear over the concentration range of 5×10?5 to 1.2×10?3 M with a sensitivity of 3.6 μA mM?1. Furthermore, PLL‐GA‐SiMo film electrode showed fast response and good stability.  相似文献   

10.
A simple electrochemical method was developed to determine metronidazole based on β‐cyclodextrin‐functionalized gold nanoparticles/poly(L ‐cysteine) modified glassy carbon electrode (β‐CD‐GNPs/poly(L ‐cys)/GCE). The electropolymerized film of poly(L ‐cys) provides a stable matrix for the fabrication of a sensing interface. β‐CD‐GNPs can form inclusion complexes with metronidazole and act as a modifier with catalytic function. The modified electrode exhibited excellent electrocatalytic activity towards metronidazole. The reaction of metronidazole at the modified electrode was an irreversible process controlled by diffusion. Under optimum experimental conditions, the logarithm of catalytic currents shows a good linear relationship with that of the metronidazole concentration in the range of 0.1–600 µmol/L with a low detection limit of 14 nmol/L. In addition, the modified electrode exhibited satisfactory stability, sensitivity and reproducibility, and could be applied to the determination of metronidazole in an injection solution.  相似文献   

11.
《Electroanalysis》2005,17(20):1835-1840
An L ‐cysteine modified gold electrode for the determination of copper in the presence of various amounts of arsenic with anodic stripping voltammetry has been studied. The electrode was fabricated by immersing a gold electrode in an ethanol solution of 5mM L ‐cysteine for 60 min. Various parameters, such as the effect of different supporting electrolytes, the pH of the electrolyte and the deposition potential were investigated. Under optimum conditions, copper was accumulated at ?0.3 V (vs. SEC) for 60 s in 0.1 M phosphate buffer pH 5.0 in the presence of different amounts of arsenic. Essentially the same sensitivities (0.33±0.001 μA/μM) and limits of detection (0.13±0.002 μM) of copper were obtained with various amount of arsenic in the range 2 μM to 20 μM.  相似文献   

12.
This paper reports the fabrication of Au nanoparticles (Au NPs)‐Ni‐Al layerd double hydroxide (LDH) composite film by one step electrochemical deposition on the surface of a glass carbon electrode from the mixture solution containing HAuCl4 and nitrate salts of Ni2+ and Al3+. Improved conductivity was obtained by Au NPs codeposited on LDH film. The synergic effect of LDHs and Au NPs dramatically improves the performance of L ‐cysteine electro‐oxidation, displaying low oxidation peak potential (0.16 V) and high current response. Thus the electrode was used to sense L ‐cysteine, showing good sensitivity and selectivity.  相似文献   

13.
《Electroanalysis》2003,15(21):1693-1698
The voltammetric behaviors of uric acid (UA) and L ‐ascorbic acid (L ‐AA) were studied at well‐aligned carbon nanotube electrode. Compared to glassy carbon, carbon nanotube electrode catalyzes oxidation of UA and L ‐AA, reducing the overpotentials by about 0.028 V and 0.416 V, respectively. Based on its differential catalytic function toward the oxidation of UA and L ‐AA, the carbon nanotube electrode resolved the overlapping voltammetric response of UA and L ‐AA into two well‐defined voltammetric peaks in applying both cyclic voltammetry (CV) and differential pulse voltammetry (DPV), which can be used for a selective determination of UA in the presence of L ‐AA. The peak current obtained from DPV was linearly dependent on the UA concentration in the range of 0.2 μM to 80 μM with a correlation coefficient of 0.997. The detection limit (3δ) for UA was found to be 0.1 μM. Finally, the carbon nanotube electrode was successfully demonstrated as a electrochemical sensor to the determination of UA in human urine samples by simple dilution without further pretreatment.  相似文献   

14.
《Electroanalysis》2005,17(22):2052-2056
Controlled potential coulometry using carbon felt electrode impregnated with electrolytic solution realizes very rapid complete electrolysis and can be used to measure the faster reaction rate constant than that using conventional electrolytic cell. In this research, concentration step method was adopted to investigate coupling reaction rate of L ‐cysteine radical. The coupling reaction rate of L ‐cysteine radical becomes much larger than further electrode reaction rate of L ‐cysteine radical at high L ‐cysteine concentration, because the coupling reaction rate is proportional to the second order of L ‐cysteine radical concentration although the further electrode reaction rate is proportional to the first order of L ‐cysteine radical concentration. At a low constant potential value, apparent number of electrons (napp) increased from 1 (L ‐cystine is produced) to 2 (L ‐cysteine sulfenic acid, RSOH, may be produced) according to decrease in concentration of L ‐cysteine to be electrolyzed. The second order rate constant of coupling reaction was estimated to be about 1200 dm3 mol?1 s?1 at 20 °C by curve fitting method for napp vs. logarithm of L ‐cysteine concentration. Apparent number of electrons (napp) consumed in the electrode oxidation of L ‐cysteine gradually increased as an applied potential increases, because the consecutive electrode reaction steps with different electrode reaction rates were involved in the electrode oxidation of L ‐cysteine. In the present method, the constant limited electrolytic current was observed at high electrode potential range, which suggests that electrode oxidation rate of L ‐cysteine is kinetically controlled.  相似文献   

15.
This communication describes the determination of an essential amino acid, L ‐methionine (L ‐Met) in the presence of important interferents, ascorbic acid (AA) and uric acid (UA) at physiological pH using a glassy carbon electrode modified with an electropolymerized film of 3‐amino‐5‐mercapto‐1,2,4‐triazole (p‐AMTa). The bare glassy carbon electrode fails to show a voltammetric signal for L ‐Met in the presence of AA and UA at pH 7.2. However, the p‐AMTa electrode separates the voltammetric signals of AA, UA and L ‐Met with pronounced oxidation currents. The amperometric current of L ‐Met was increased linearly from 1.0×10?7 to 1×10?4 M and the detection limit was found to be 4.12×10?10 M (S/N=3).  相似文献   

16.
《Electroanalysis》2006,18(17):1722-1726
The electrochemical properties of L ‐cysteic acid studied at the surface of p‐bromanil (tetrabromo‐p‐benzoquinone) modified carbon paste electrode (BMCPE) in aqueous media by cyclic voltammetry (CV) and double step potential chronoamperometry. It has been found that under optimum condition (pH 7.00) in cyclic voltammetry, the oxidation of L ‐cysteic acid at the surface of BMCPE occurs at a half‐wave potential of p‐bromanil redox system (e.g., 100 mV vs. Ag|AgCl|KClsat), whereas, L ‐cysteic acid was electroinactive in the testing potential ranges at the surface of bare carbon paste electrode. The apparent diffusion coefficient of spiked p‐bromanil in paraffin oil was also determined by using the Cottrell equation. The electrocatalytic oxidation peak current of L ‐cysteic acid exhibits a linear dependency to its concentration in the ranges of 8.00×10?6 M–6.00×10?3 M and 5.2×10?7 M–1.0×10?5 M using CV and differential pulse voltammetry (DPV) methods, respectively. The detection limits (2σ) were determined as 5.00×10?6 M and 4.00×10?7 M by CV and DPV methods. This method was used as a new, selective, rapid, simple, precise and suitable voltammetric method for determination of L ‐cysteic acid in serum of patient's blood with migraine disease.  相似文献   

17.
Sol-gel technique was used for construction of a carbon composite electrode. The prepared carbon ceramic electrode was modified with electroless deposition of chlorogenic acid for less than 1 min. The adsorbed thin films of chlorogenic acid on carbon composite electrode show one pair of peaks with a surface confined characteristic, which strongly depends on the solution pH, as anticipated for quinone /hydroquinone functionalities. The modified electrode shows highly catalytic activity toward hydrazine electrooxidation at wide pH range (5–11). Also the rotating modified electrode shows excellent analytical performance for amperometric determination of hydrazine. The detection limit, sensitivity, response time and linear dynamic range are 20 nM, 220 nA / μM, 1 second and 0.1 μM-1 mM, respectively. The catalytic rate constant for hydrazine oxidation at the surface of modified electrode was evaluated by cyclic voltammetry and was found to be around 1.5×103 M−1s−1in phosphate buffer solution (pH 8). The precision of chronoamperometric measurements was 1–3% for 5 replicate determinations in the concentration range of the linear calibration. The reproducibility of modified CCE was evaluated with 8 successive polishing and modifications and then the anodic peak current was measured (RSD 2%). The advantages of this sensor are excellent catalytic activity, high sensitivity, good reproducibility and simplicity of preparation at short time periods.  相似文献   

18.
《Electroanalysis》2005,17(7):619-624
The electrocatalytic oxidation of L ‐cysteine by (ferrocenylmethyl)trimethylammonium at a glassy carbon electrode in 0.1 M Na2SO4 aqueous solution has been studied. The rate constant for the catalytic reaction was evaluated as (4.28±0.05)×103 M?1 s?1 by chronoamperometry. Experimental conditions, which maximize the current efficiency of the electrocatalytic oxidation, such as pH value and the concentration of the catalyst, were also investigated. The experimental results of electrocatalytic kinetics of L ‐cysteine oxidation on GCE in the presence of (ferrocenylmethyl)trimethylammonium obviously support the reaction mechanism proposed and the rate determining step assumed in scheme described in this work.  相似文献   

19.
The present work describes oxidation of ascorbic acid (AA) at octacyanomolybdate‐doped‐glutaraldehyde‐cross‐linked poly‐L ‐lysine (PLL‐GA‐Mo(CN) film modified glassy carbon electrode in 0.1 M H2SO4. The modified electrode has been successfully prepared by means of electrostatically trapping Mo(CN) mediator in the cationic film of glutaraldehyde‐cross‐linked poly‐L ‐lysine. The dependence of peak current of modified electrode in pure supporting indicates that the charge transfer in the film was a mixed process at low scan rates (5 to 200 mV s?1), and kinetically restrained at higher scan rates (200 to 1000 mV s?1). Cyclic voltammetry and rotating disk electrode (RDE) techniques are used to investigate the electrocatalytic oxidation of ascorbic acid and compared with its oxidation at bare and undoped PLL‐GA film coated electrodes. The rate constant of catalytic reaction k obtained from RDE analysis was found to be 9.5×105 cm3 mol?1 s?1. The analytical determination of ascorbic acid has been carried out using RDE technique over the physiological interest of ascorbic acid concentrations with a sensitivity of 75 μA mM?1. Amperometric estimation of AA in stirred solution shows a sensitivity of 15 μA mM?1 over the linear concentration range between 50 and 1200 μM. Interestingly, PLL‐GA‐Mo(CN) modified electrode facilitated the oxidation of ascorbic acid but not responded to other electroactive biomolecules such as dopamine, uric acid, NADH, glucose. This unique feature of PLL‐GA‐Mo(CN) modified electrode allowed for the development of a highly selective method for the determination of ascorbic acid in the presence of interferents.  相似文献   

20.
This work describes the electrochemical properties of glassy carbon electrodes (GCE) modified with chromium(III) hexacyanoferrate(II) (Crhf) nanoparticles attached multiwalled carbon nanotube (MWNTs). The morphological characterization of Crhf/MWNTs nanocomposites was examined by scanning electron microscopy (SEM), UV‐vis spectroscopy, and Fourier transform infrared spectrometry (FT‐IR). The electrocatalytic activity of these nanocomposites was investigated and showed a good electrocatalytic effect for oxidation of L ‐cysteine (L ‐Cys) in 0.1 M phosphate buffer solution (pH 3.0). Under optimum conditions linear calibration graphs were obtained over the L ‐Cys concentration range 5.0×10?7 to 6.0×10?5 M with a correlation coefficient of 0.9998 and a detection limit (signal‐to‐noise ratio was 3) of 1.0×10?8 M. The proposed method is simple and it also showed excellent sensitivity and stability. The excellent electrocatalytic ability of the modified electrode towards L ‐Cys manifests that the Crhf/MWNTs can provide a new platform for biosensors and other biology.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号