首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 78 毫秒
1.
A new method for the determination of (237)Np and Pu isotopes in large soil samples has been developed that provides enhanced uranium removal to facilitate assay by inductively coupled plasma mass spectrometry (ICP-MS). This method allows rapid preconcentration and separation of plutonium and neptunium in large soil samples for the measurement of (237)Np and Pu isotopes by ICP-MS. (238)U can interfere with (239)Pu measurement by ICP-MS as (238)UH(+) mass overlap and (237)Np via (238)U peak tailing. The method provides enhanced removal of uranium by separating Pu and Np initially on TEVA Resin, then transferring Pu to DGA resin for additional purification. The decontamination factor for removal of uranium from plutonium for this method is greater than 1×10(6). Alpha spectrometry can also be applied so that the shorter-lived (238)Pu isotope can be measured successfully. (239) Pu, (242)Pu and (237)Np were measured by ICP-MS, while (236)Pu and (238)Pu were measured by alpha spectrometry.  相似文献   

2.
A new method that allows rapid preconcentration and separation of plutonium and neptunium in water samples was developed for the measurement of 237Np and Pu isotopes by inductively-coupled plasma mass spectrometry (ICP-MS) and alpha spectrometry. 238U can interfere with 239Pu measurement by ICP-MS as 238UH+ mass overlap and 237Np via peak tailing. The method provide enhanced removal of uranium by separating Pu and Np initially on TEVA Resin, then moving Pu to DGA resin for additional removal of uranium. The decontamination factor for uranium from Pu is almost 100,000 and the decontamination factor for U from Np is greater than 10,000. This method uses stacked extraction chromatography cartridges and vacuum box technology to facilitate rapid separations. Preconcentration is performed using a streamlined calcium phosphate precipitation method. Purified solutions are split between ICP-MS and alpha spectrometry so that long and short-lived Pu isotopes can be measured successfully. The method allows for simultaneous extraction of 20 samples (including QC samples) in 4?C6 h, and can also be used for emergency response. 239Pu, 242Pu and 237Np were measured by ICP-MS, while 236Pu, 238Pu, and 239Pu were measured by alpha spectrometry.  相似文献   

3.
A new rapid separation method that allows separation and preconcentration of actinides in urine samples was developed for the measurement of longer lived actinides by inductively coupled plasma mass spectrometry (ICP-MS) and short-lived actinides by alpha spectrometry; a hybrid approach. This method uses stacked extraction chromatography cartridges and vacuum box technology to facilitate rapid separations. Preconcentration, if required, is performed using a streamlined calcium phosphate precipitation. Similar technology has been applied to separate actinides prior to measurement by alpha spectrometry, but this new method has been developed with elution reagents now compatible with ICP-MS as well. Purified solutions are split between ICP-MS and alpha spectrometry so that long- and short-lived actinide isotopes can be measured successfully. The method allows for simultaneous extraction of 24 samples (including QC samples) in less than 3 h. Simultaneous sample preparation can offer significant time savings over sequential sample preparation. For example, sequential sample preparation of 24 samples taking just 15 min each requires 6 h to complete. The simplicity and speed of this new method makes it attractive for radiological emergency response. If preconcentration is applied, the method is applicable to larger sample aliquots for occupational exposures as well. The chemical recoveries are typically greater than 90%, in contrast to other reported methods using flow injection separation techniques for urine samples where plutonium yields were 70-80%. This method allows measurement of both long-lived and short-lived actinide isotopes. 239Pu, 242Pu, 237Np, 243Am, 234U, 235U and 238U were measured by ICP-MS, while 236Pu, 238Pu, 239Pu, 241Am, 243Am and 244Cm were measured by alpha spectrometry. The method can also be adapted so that the separation of uranium isotopes for assay is not required, if uranium assay by direct dilution of the urine sample is preferred instead. Multiple vacuum box locations may be set-up to supply several ICP-MS units with purified sample fractions such that a high sample throughput may be achieved, while still allowing for rapid measurement of short-lived actinides by alpha spectrometry.  相似文献   

4.
Plutonium isotopes were measured by alpha-spectrometry and ICP-MS in sediment samples from two European lakes: Blelham Tarn in U.K. and Stechlin lake in Germany. The ICP-MS measurements were made after alpha-spectrometry counting of the planchets. The planchets were prepared by traditional electrodeposition method after radiochemical extraction, separation and purification of the Pu fraction. A short radiochemical separation using plutonium selective resin, between the two spectrometry measures, is presented. The results show that these two complementary methods are in good agreement, the plutonium activity concentrations are the same. Alpha-spectrometry allows the 238Pu determination and ICP-MS individual measurement of 239Pu and 240Pu. 238Pu/239+240Pu and 240Pu/239Pu ratios are calculated to determine the plutonium contamination source. With the results of these two techniques, it could be demonstrate that the plutonium is of global fallout origin.  相似文献   

5.
Quantitative and isotopic measurement of actinide elements is required in many circumstances in the nuclear industry. For example, determination of very low levels of these alpha emitters in human urine samples is used to assess the internal committed dose for nuclear workers. Quantifying actinide isotopes in radioactive waste from nuclear processing and nuclear facility decommissioning provides important information for waste management. Accurate determination of the uranium isotopic ratios in reactor fuels provides fuel burnup information. Inductively coupled plasma mass spectrometry (ICP-MS) has been used for the determination of Th, U, and Pu in various samples including urine, nuclear waste, and nuclear fuel in our laboratory. In order to maximize the capability of the technique and ensure quality analyses, ICP-MS was used to analyze samples directly, or after pre-treatment to separate complicated matrices or to concentrate the analyte(s). High-efficiency sample introduction techniques were investigated. Spectral interferences to minor isotopes caused by peak tails and hydride ions of major actinide isotopes were studied in detail using solutions prepared with light and heavy waters. The quality of the isotopic ratio measurement was monitored using standard reference materials.  相似文献   

6.
Fission track /FT/ method and inductively coupled plasma mass spectrometry /ICP-MS/, that is a new analytical technique for the analysis of trace element, were used for the measurement of240Pu/239Pu ratios in environmental samples. The results obtained by both methods are in agreement within the relative deviation of 9–13%. The precision in ICP-MS was found to be better than in it the FT-method. These methods are applicable to measure the Pu isotopes ratio at low concentration levels in environmental samples.  相似文献   

7.
Inductively coupled plasma mass spectrometry (ICP-MS) has been applied to the measurement of plutonium isotopes in soils. In the ICP-MS, a calibration curve method was conveniently utilized even in high viscosity solution using a Babington nebulizer. Plutonium concentrations in soil around the Kashiwazaki-Kariwa nuclear power station were found to be in the range of 0.054 to 1.0 Bq/kg with an average of 0.27 Bq/kg. The ratios of 239Pu/240Pu were also obtained with the ICP-MS to investigate the origin of Pu-isotopes. On the basis of this result, the origin of the Pu-isotopes was attributed to be fallout from the past atmospheric nuclear tests.  相似文献   

8.
The isotopic composition of single uranium and plutonium particles was measured with an inductively coupled plasma mass spectrometer (ICP-MS) and a thermal ionization mass spectrometer (TIMS). Particles deposited on a carbon planchet were first analyzed with an energy dispersive X-ray spectrometer (EDX) attached to a scanning electron microscope (SEM) and then transferred on to a silicon wafer using a manipulator. The particle on the silicon wafer was dissolved with nitric acid and the isotopic ratios of U and Pu were measured with ICP-MS and TIMS. The results obtained by both methods for particles of certified reference materials showed good agreement with the certified values within the expected uncertainty. The measurement uncertainties obtained in this study were similar for both mass spectrometric methods. This study was performed to establish the method of particle analysis with SEM, EDX, the particle manipulation and chemical preparation technique, and the measurement of isotopic ratios of U and Pu in a single particle by mass spectrometry.  相似文献   

9.
Zheng J  Yamada M 《Talanta》2006,69(5):1246-1253
An analytical method for the determination of plutonium concentration and its isotope ratio (240Pu/239Pu) for settling particle samples by inductively coupled plasma mass spectrometry (ICP-MS) is presented. The generally used approach for Pu preconcentration by increasing the amount of samples is not applicable because of the small size of settling particle samples available for the analysis for Pu isotopes. Efforts were made to improve the sensitivity of a sector-field ICP-MS (SF-ICP-MS) and reduce the 238UH+ interference for Pu analysis by combining a high-efficiency sample introduction system (APEX-Q). An extremely low detection limit of 0.07 fg Pu was achieved, which allowed the determination of Pu isotope ratio at femtogram levels. The precision and accuracy of 240Pu/239Pu isotope ratio analysis were carefully examined with a certified Pu isotope standard (NBS-947) and an ocean sediment reference material (IAEA-368). Simple anion-exchange chromatography for the separation and purification of Pu was combined with the APEX-Q/SF-ICP-MS system to determine Pu isotopes in settling particles collected in the East China Sea continental margin. The obtained results supported a previous observation on the lateral transport of Pu containing particles in this continental margin.  相似文献   

10.
Assays of alpha- and beta-emitting radionuclides in swipe samples are often required to monitor the presence of removable surface contamination for radiological protection and control in nuclear facilities. Swipe analysis has also proven to be a very sensitive analytical technique to detect nuclear signatures for safeguard verification purposes. A new sequential method for the determination of actinide isotopes and radiostrontium in swipe samples, which utilizes a streamlined column separation with stacked anion and extraction chromatography resins, has been developed. To validate the separation procedure, spike and blank samples were prepared and analyzed by inductively coupled mass spectrometry (ICP-MS), alpha spectrometry and liquid scintillation (LS) counting. Low detection limits have been achieved for isotopic analysis of Pu (238Pu, 239Pu, 240Pu, 241Pu), U (234U, 235U, 238U), Am (241Am), Cm (242Cm, 243/244Cm) and Sr (90Sr) at ultra-trace concentration levels in swipe samples.  相似文献   

11.
In the framework of a collaboration between laboratories involved in bulk U and Pu analysis of environmental samples (DIF centre of the French Commissariat à l’Energie Atomique, US National Laboratories of New Brunswick, Lawrence Livermore, Pacific Northwest, Oak Ridge, and Los Alamos), two round-robins were organised, each one consisting of the complete analysis (chemical preparation and isotope measurement) of three Quality Control samples. The samples were 10 × 10 cm cotton tissues (“swipe samples”) containing low amounts of U (from ~20 to ~150 ng) and Pu (from ~0.15 to ~10 pg). Despite using different spikes, different methods of sample preparation and different analytical instrumentation, the results for U and Pu contents and isotopic compositions reported by all laboratories are globally in good agreement. All laboratories are able to measure sub-pg amounts of U and Pu isotopes with acceptable accuracy and reproducibility, even if limited discrepancies are observed affecting one or other measurement and/or laboratory. General and laboratory specific recommendations were discussed and adopted to continue to improve the accuracy and precision of the measurements.  相似文献   

12.
Summary A procedure is described to extend the current radiochemical method of seawater analysis for Pu and Am including Np. Short-lived 239Np tracer was prepared by separation from its 243Am parent. Irish Sea Water reference material (IAEA-381) containing known concentrations of 237Np, Pu isotopes and 241Am was used to test the procedure for small water volumes. Inductively-coupled plasma mass spectrometry (ICP-MS) was used in addition to alpha spectrometry for measurement of 237Np in the purified final Np fractions.  相似文献   

13.
This study presents a rapid and quantitative sequential radiochemical separation method for Pu, U, Am and Sr isotopes in environmental samples with extraction chromatographic resins. After radionuclides were leached from the samples with 6 M HNO3, Pu and U isotopes were adsorbed onto the UTEVA column and Am isotopes were adsorbed onto the TRU column connected with the UTEVA column. Also, 90Sr was adsorbed onto the Sr column connected with the TRU column. Pu and U isotopes were purified from other nuclides through the UTEVA column. In addition, Am isotopes were separated from other nuclides with the TRU column. Finally, 90Sr was purified with the Sr resin. After α source preparation for the purified Pu, U and Am isotopes with micro-coprecipitation method, Pu, U and Am isotopes were measured using alpha spectrometry. On the other hand, 90Sr was measured using a low level liquid scintillation counter. The radiochemical procedure for Pu, U, Am and Sr nuclides investigated in this study has been applied to environmental samples after validating the simulated samples.  相似文献   

14.
 Methodologies based on secondary ion mass spectrometry (SIMS) for isotopic measurements in nuclear forensic applications relevant to the age determination of Pu particles and isotopic composition of oxygen for geolocation assignment are described. For the age determination of Pu particles, a relative sensitivity factor (RSF) to correct for the different ionisation efficiencies of U and Pu, was obtained by analysing standard Pu materials with known ages. An RSF of 2.41±0.05 was obtained for PuO2 from measurements on samples with different Pu/U ratios. In a sample of known origin, using this RSF value, the age calculated from the 238Pu/234U and 240Pu/236U ratios agreed well with the reported age of 2.3 years. For geolocation assignment, a new approach based on the measurement of differences in the natural abundance of 18O and 16O isotopes and their ratio was developed. The instrumental mass discrimination of the 18O/16O ratio was determined using three O-isotope samples of different chemical composition. The measured precision (the standard error of 100 cycles/analysis) obtained for the oxygen isotopic measurement on the samples was typically ±1.1‰.  相似文献   

15.
Uranium (U) and plutonium (Pu) isotopes in coral soils, contaminated by nuclear weapons testing in the northern Marshall Islands, were isolated by ion-exchange chromatography and analyzed by mass spectrometry. The soil samples were spiked with 233U and 242Pu tracers, dissolved in minerals acids, and U and Pu isotopes isolated and purified on commercially available ion-exchange columns. The ion-exchange technique employed a TEVA® column coupled to a UTEVA® column. U and Pu isotope fractions were then further isolated using separate elution schemes, and the purified fractions containing U and Pu isotopes analyzed sequentially using multi-collector inductively coupled plasma mass spectrometer (MCICP-MS). High precision measurements of 234U/235U, 238U/235U, 236U/235U, and 240Pu/239Pu in soil samples were attained using the described methodology and instrumentation, and provide a basis for conducting more detailed assessments of the behavior and transfer of uranium and plutonium in the environment.  相似文献   

16.
Inductively coupled plasma-mass spectrometry (ICP-MS) was used to concurrently determine multiple long-lived (t1/2>104 y) actinide isotopes in soil leachates. Ultrasonic nebulization was found to maximize instrument sensitivity. Instrument detection limits for actinides in solution ranged from 50 mBq L–1 (239Pu) to 2Bq L–1 (235U). Hydride adducts of232Th and238U interfered with the determinations of233U and239Pu; thus, extraction chromatography was used to concentrate the analytes and separate uranium from the other actinides in advance of mass spectrometric determination. Alpha spectrometric determinations of230Th,239Pu, and the234U/238U activity ratio in soil leachates compared well with ICP-MS determinations; however, there were some small systematic differences (ca. 10%) between ICP-MS and -spectrometric determinations of234U and238U activities. These differences were attributed to the use of different isotope dilution spikes for ICP-MS and -spectrometry.  相似文献   

17.
Elemental and isotopic determination of americium and curium in spent nuclear fuels is necessary to validate neutronic calculation codes and for nuclear waste disposal purposes. Prior to mass spectrometric analysis, it is mandatory to perform separations in order to eliminate isobaric interferences between U, Pu, Am and Cm. In the spent fuels samples analyzed, a separation of U and Pu has been first realized with an anion-exchange resin. Then a rapid Am/Cm separation has been developed by high-performance liquid chromatography (HPLC) with an on-line detection using the Am and Cm α-emission. The influence of the different parameters on the chromatographic separation are described and discussed. Inductively coupled plasma mass spectrometry (ICP-MS) and thermal-ionization mass spectrometry (TIMS) have been used to measure the isotopic composition of U, Am and Cm and to determine the 241Am/238U and 244Cm/238U ratios with the double spike isotope dilution method. The measurement procedures and the accuracy and precision of the results obtained with a quadrupole ICP-MS on different spent fuels samples are discussed and compared with those obtained by TIMS, used as a reference technique. Received: 30 November 1998 / Revised: 8 January 1999 / Accepted: 12 January 1999  相似文献   

18.
Elemental and isotopic determination of americium and curium in spent nuclear fuels is necessary to validate neutronic calculation codes and for nuclear waste disposal purposes. Prior to mass spectrometric analysis, it is mandatory to perform separations in order to eliminate isobaric interferences between U, Pu, Am and Cm. In the spent fuels samples analyzed, a separation of U and Pu has been first realized with an anion-exchange resin. Then a rapid Am/Cm separation has been developed by high-performance liquid chromatography (HPLC) with an on-line detection using the Am and Cm α-emission. The influence of the different parameters on the chromatographic separation are described and discussed. Inductively coupled plasma mass spectrometry (ICP-MS) and thermal-ionization mass spectrometry (TIMS) have been used to measure the isotopic composition of U, Am and Cm and to determine the 241Am/238U and 244Cm/238U ratios with the double spike isotope dilution method. The measurement procedures and the accuracy and precision of the results obtained with a quadrupole ICP-MS on different spent fuels samples are discussed and compared with those obtained by TIMS, used as a reference technique. Received: 30 November 1998 / Revised: 8 January 1999 / Accepted: 12 January 1999  相似文献   

19.
A simple, rapid and reliable method was developed for the simultaneous determination of uranium and plutonium isotopes by alpha-spectrometry using a single source. A new uranium tracer230U was applied as well as the236Pu tracer to determine overall yields of uranium and plutonium isotopes throughout the entire procedure employed. The analytical procedure consists of sample leaching with 8N HNO3 solution, purification by solvent extraction, simultaneous electrodeposition of U and Pu, and subsequent alpha-spectrometry with a silicon detector. In the solvent extraction using TOA/xylene from 8N HNO3 solution, the preferential extractability of Pu rather than U permits to purify simultaneously the trace amounts of Pu and the macro amounts of U, as in the case of ordinary soil samples, resulting in favourable peak heights for both isotopes. From a single alpha-spectrum, the determinations of238U,234U (and their ratio of234U/238U),239+240Pu, and238Pu contents were conveniently carried out after correcting the overall yields obtained from230U and236Pu activities in the same spectrum. This analytical method was satisfactorily applied to the determination of U and Pu isotope contents in some soils.  相似文献   

20.
It is well known that ammunition containing depleted uranium (DU) was used by NATO during the Balkan conflict. To evaluate the origin of DU (the enrichment of natural uranium or the reprocessing of spent nuclear fuel) it is necessary to directly detect the presence of activation products ((236)U, (239)Pu, (240)Pu, (241)Am, and (237)Np) in the ammunition. In this work the analysis of actinides by alpha-spectrometry was compared with that by inductively coupled plasma mass spectrometry (ICP-MS) after selective separation of ultratraces of transuranium elements from the uranium matrix. (242)Pu and (243)Am were added to calculate the chemical yield. Plutonium was separated from uranium by extraction chromatography, using tri- n-octylamine (TNOA), with a decontamination factor higher than 10(6); after elution plutonium was determined by ICP-MS ((239)Pu and (240)Pu) and alpha-spectrometry ((239+240)Pu) after electroplating. The concentration of Pu in two DU penetrator samples was 7 x 10(-12) g g(-1) and 2 x 10(-11) g g(-1). The (240)Pu/(239)Pu isotope ratio in one penetrator sample (0.12+/-0.04) was significantly lower than the (240)Pu/(239)Pu ratios found in two soil samples from Kosovo (0.35+/-0.10 and 0.27+/-0.07). (241)Am was separated by extraction chromatography, using di(2-ethylhexyl)phosphoric acid (HDEHP), with a decontamination factor as high as 10(7). The concentration of (241)Am in the penetrator samples was 2.7 x 10(-14) g g(-1) and <9.4 x 10(-15) g g(-1). In addition (237)Np was detected at ultratrace levels. In general, ICP-MS and alpha-spectrometry results were in good agreement.The presence of anthropogenic radionuclides ((236)U, (239)Pu,(240)Pu, (241)Am, and (237)Np) in the penetrators indicates that at least part of the uranium originated from the reprocessing of nuclear fuel. Because the concentrations of radionuclides are very low, their radiotoxicological effect is negligible.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号